Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹29.7 L+₹8.2 L (38.3%)Admitted-Finance 8 3 253 3A PARAMESWARI ENCLAVE PARAMESWAIRI NAGAR SULLURUPETA SRI POTTI SRIRAMULU TIRUPATI DIST ANDHRA PRADESH 524121 | SPSR NELLORE | ANDHRA PRADESH | 524121 | L2 | Admitted-Finance | |
| 3 | L3₹34.6 L+₹13.1 L (61.0%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | Rejected-Technical | - | Rejected-Technical Dis Qualified |
| Sl No | Description | Qty | Unit | ashirwad engineers L3 | C R ELECTRICALS L2 | YOUNG ENGINEERS ELECTRICAL SOLUTTIONS L1 |
|---|---|---|---|---|---|---|
| 1.10 | Supply and laying of 31/2 x 240 Sqmm, XLPE insulated, armoured LTUG Cable with ISI mark. Excavation of earth upto the depth of 1Mtr and putting 0.15 metre layer of sand and covering the cable completely with box type bricks and sand and refilling the earth to make good in good condition including end terminations | 1,200 | Mtr | 1,950 ₹23,40,000 | 1,070 ₹12,84,000 Lowest | 1,100 ₹13,20,000 |
| 2.10 | Outdoor type SS Pillar Box: -
Supply, erection, testing and commissioning of Outdoor type pillar box:
The panel shall be outdoor type, dust, vermin weatherproof, IP65, enclosure fabricated from SS316 grade sheet of 2mm thick, suitable angled and flat mounted on GI C type channel (ISMC) along with providing suitable foundation concrete minimum 1Mtr from the Ground level.
The pillar box incorporating the following specifications along with suitable bus bar arrangement:
Incomer: 400A, (3Pole+N disconnect switch)- 1No
Outgoing: 250A (3Pole+N disconnect switch)-4 Nos
Auto Transfer Switch:250A for connecting alternative power supply between two different feeders.
Outgoing:125A (3Pole+N disconnect switch)- 4 Nos, Busbar: Aluminum Flat type busbar with insulation, [R, Y, B],
Each [incoming and outgoing feeders] have the multifunction meter for taking meter reading.
Each [incoming and outgoing feeders] have the required CT arrangements.
Tri Tri-vector meter with RS485 port along with internal wirings with different slot reading program at the incoming main switch.
Astronomical time switch-1No and MNX 70 Contactor -1No, including the internal wiring arrangement for controlling streetlights. | 1 | set | 2,80,000 ₹2,80,000 Lowest | 13,20,000 ₹13,20,000 | 3,99,999 ₹3,99,999 |
| 3.10 | Supply and laying of 31/2 x 120 Sqmm, XLPE insulated, armoured LTUG Cable with ISI mark. Excavation of earth upto the depth of 1Mtr and putting 0.15 metre layer of sand and covering the cable completely with box type bricks and sand and refilling the earth to make good in good condition including end terminations. | 600 | Mtr | 1,350 ₹8,10,000 | 568 ₹3,40,800 Lowest | 690 ₹4,14,000 |
| 4.10 | Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry | 2 | set | 16,500 ₹33,000 | 15,000 ₹30,000 | 8,500 ₹17,000 Lowest |
Tender Value
₹21.9 L
EMD Value
₹43,900
Closing Date
6 Aug 2025, 3:00 pmClosed
CME
CME VOCPA
Providing Power Supply arrangement for the Green Hydrogen Plant and museum at VOCPA premises
2025_VOCPT_241064_1
MEE/ELEC0ESTW/19/2025/Mech SE1/7431
Open Tender
Electrical Works
Works
90 days
VOCPA
As per the tender conditions
14 documents required · 14 mandatory
₹0
₹43,900
Yes
12 Sept 2025
11 Jul 2025
7 Aug 2025
11 Jul 2025
6 Aug 2025
11 Jul 2025
Amount
Supply and laying of 31/2 x 240 Sqmm, XLPE insulated, armoured LTUG Cable with ISI mark. Excavation of earth upto the depth of 1Mtr and putting 0.15 metre layer of sand and covering the cable completely with box type bricks and sand and refilling the earth to make good in good condition including end terminations
Outdoor type SS Pillar Box: - Supply, erection, testing and commissioning of Outdoor type pillar box: The panel shall be outdoor type, dust, vermin weatherproof, IP65, enclosure fabricated from SS316 grade sheet of 2mm thick, suitable angled and flat mounted on GI C type channel (ISMC) along with providing suitable foundation concrete minimum 1Mtr from the Ground level. The pillar box incorporating the following specifications along with suitable bus bar arrangement: Incomer: 400A, (3Pole+N disconnect switch)- 1No Outgoing: 250A (3Pole+N disconnect switch)-4 Nos Auto Transfer Switch:250A for connecting alternative power supply between two different feeders. Outgoing:125A (3Pole+N disconnect switch)- 4 Nos, Busbar: Aluminum Flat type busbar with insulation, [R, Y, B], Each [incoming and outgoing feeders] have the multifunction meter for taking meter reading. Each [incoming and outgoing feeders] have the required CT arrangements. Tri Tri-vector meter with RS485 port along with internal wirings with different slot reading program at the incoming main switch. Astronomical time switch-1No and MNX 70 Contactor -1No, including the internal wiring arrangement for controlling streetlights.
Supply and laying of 31/2 x 120 Sqmm, XLPE insulated, armoured LTUG Cable with ISI mark. Excavation of earth upto the depth of 1Mtr and putting 0.15 metre layer of sand and covering the cable completely with box type bricks and sand and refilling the earth to make good in good condition including end terminations.
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
C R ELECTRICALS (BID ID -882863)
ashirwad engineers (BID ID -879991)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .