Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC 146 B SICOP BIRPUR INDUSTRIAL AREA BARI BRAHMANA JAMMU 181133 J K | BARI BRAHMANA | JAMMU | JAMMU AND KASHMIR | 181133 | ₹38.8 L Quoted ₹39 L | L1 | Accepted-AOC L1 |
| 2 | L2₹43.5 L+₹4.5 L (11.5%)Rejected-Finance HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹43.5 L+₹4.5 L (11.5%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹43.5 L+₹4.5 L (11.6%)Rejected-Finance WARD NO 11 HOUSE NO 305 JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹43.5 L+₹4.5 L (11.6%) | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹44.4 L+₹5.4 L (13.9%)Rejected-Finance | ₹44.4 L+₹5.4 L (13.9%) | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹44.8 L+₹5.8 L (14.8%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹44.8 L+₹5.8 L (14.8%) | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | VARDHMAN INTERNATIONAL L6 | vijay builders L5 | V K Sales and Construction Co L8 | PARDEEP SHARMA L3 | M/s Sahib Construction and engineers L7 | PROACH ASSOCIATES BUILDERS & ENGINEERS L4 | jaima electricals L1 | M/S N.K. POWER SYSTEMS AND PROJECTS L2 | M/S DHARAM & SONS ENTERPRISES L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fixing in replacement of MCCB, 4 pole, 415 volt of capacity 630 amp,Ics=50%Icu short circuit, breaking capacity not less than 50 KA , thermal setting 80 to 100 % confirming to IEC-947, IS-13947 , including thimbles, nuts, bolts ,washers etc disconnecting and making incoming , out going connections complete all as specified and directed by Engineer-in-Charge. | 10 | Each | 18,000 ₹1,80,000 | 25,000 ₹2,50,000 | 26,600 ₹2,66,000 | 30,000 ₹3,00,000 | 17,000 ₹1,70,000 Lowest | 17,800 ₹1,78,000 | 22,400 ₹2,24,000 | 31,000 ₹3,10,000 | 28,000 ₹2,80,000 |
| 2.00 | Supply and fixing in replacement of MCCB, 3 phase, 4 pole, 415 volts of capacity 400 Amps, breaking capacity not less than 35/36 KA, thermal setting 80-100%, Ics=100% Icu conforming to IEC-947, IS-13947 including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and directed by Engineer-in-Charge. | 15 | Each | 16,000 ₹2,40,000 | 16,500 ₹2,47,500 | 17,000 ₹2,55,000 | 30,000 ₹4,50,000 | 12,500 ₹1,87,500 Lowest | 14,500 ₹2,17,500 | 14,800 ₹2,22,000 | 18,000 ₹2,70,000 | 17,000 ₹2,55,000 |
| 3.00 | Description all as per Ser item No 2.00 here-in-before, but capacity of MCCB 250 Amps 25 KA | 15 | Each | 12,500 ₹1,87,500 | 9,000 ₹1,35,000 | 9,012 ₹1,35,180 | 12,000 ₹1,80,000 | 11,000 ₹1,65,000 | 11,200 ₹1,68,000 | 7,800 ₹1,17,000 Lowest | 13,000 ₹1,95,000 | 12,500 ₹1,87,500 |
| 4.00 | Description all as per Ser item No 2.00 here-in-before, but capacity of MCCB 200 Amps 25 KA | 10 | Each | 11,500 ₹1,15,000 | 8,000 ₹80,000 | 8,123 ₹81,230 | 11,000 ₹1,10,000 | 10,000 ₹1,00,000 | 8,800 ₹88,000 | 7,000 ₹70,000 Lowest | 10,600 ₹1,06,000 | 9,000 ₹90,000 |
| 5.00 | Description all as per Ser item No 2.00 here-in-before, but capacity of MCCB 160 Amps 25 KA | 10 | Each | 10,500 ₹1,05,000 | 5,500 ₹55,000 Lowest | 7,279 ₹72,790 | 9,000 ₹90,000 | 9,000 ₹90,000 | 6,300 ₹63,000 | 6,600 ₹66,000 | 9,000 ₹90,000 | 8,000 ₹80,000 |
| 6.00 | Description all as per Ser item No 2.00 here-in-before, but capacity of MCCB 100 Amps 25 KA | 10 | Each | 7,000 ₹70,000 | 3,700 ₹37,000 | 5,598 ₹55,980 | 4,800 ₹48,000 | 6,000 ₹60,000 | 3,400 ₹34,000 Lowest | 4,600 ₹46,000 | 5,800 ₹58,000 | 6,500 ₹65,000 |
| 7.00 | Description all as per Ser item No 2.00 here-in-before, but capacity of MCCB 63 Amps 25 KA | 10 | Each | 5,000 ₹50,000 | 3,700 ₹37,000 | 5,598 ₹55,980 | 3,600 ₹36,000 | 4,000 ₹40,000 | 2,700 ₹27,000 Lowest | 4,600 ₹46,000 | 4,000 ₹40,000 | 4,000 ₹40,000 |
| 8.00 | Supply and fix MCB TPN 415 volts 63 amps with 10KA breaking capacity complete all as specified and directed by Engineer-in-Charge. | 200 | Each | 1,400 ₹2,80,000 | 1,550 ₹3,10,000 | 1,480 ₹2,96,000 | 1,300 ₹2,60,000 | 600 ₹1,20,000 Lowest | 900 ₹1,80,000 | 600 ₹1,20,000 Lowest | 1,300 ₹2,60,000 | 1,200 ₹2,40,000 |
| 9.00 | Supply and fixing in replacement of Air Circuit Breaker 415V Microprocessor based SR18G release of capacity 2000A 4P 50K MDO rated current at 50°C conformance to IS/IEC 60947-2 & IEC 60947-2. ACB should have High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity and Having Electromechanical operation not less than 20000. ACB Should have overload phase protection, overload Neutral, short circuit, instantaneous,earth fault & individual fault LED indication complete all as specified and directed by Engineer-in-Charge. | 3 | Each | 1,40,000 ₹4,20,000 Lowest | 1,60,000 ₹4,80,000 | 2,11,000 ₹6,33,000 | 2,09,000 ₹6,27,000 | 2,10,000 ₹6,30,000 | 1,78,000 ₹5,34,000 | 2,07,000 ₹6,21,000 | 2,14,000 ₹6,42,000 | 2,20,000 ₹6,60,000 |
| 10.00 | Supply and fixing in replacement of Air Circuit Breaker 415V Microprocessor based SR18G release of capacity 1600A 4P 50K MDO rated current at 50°C conformance to IS/IEC 60947-2 & IEC 60947-2. ACB should have High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity and Having Electromechanical operation not less than 20000. ACB Should have overload phase protection, overload Neutral, short circuit, instantaneous, earth fault & individual fault LED indication complete all as specified and directed by Engineer-in-Charge. | 4 | Each | 1,35,000 ₹5,40,000 Lowest | 1,60,000 ₹6,40,000 | 1,79,000 ₹7,16,000 | 1,72,000 ₹6,88,000 | 1,80,000 ₹7,20,000 | 1,55,000 ₹6,20,000 | 1,72,000 ₹6,88,000 | 1,80,000 ₹7,20,000 | 1,75,000 ₹7,00,000 |
Tender Value
₹49.8 L
EMD Value
₹99,680
Closing Date
15 May 2026, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur PO-Garhi Pin-182121
Certain repair/replacement of LT switch gear system at CHNC under GE (Utilities) Udhampur
2026_MES_761901_1
GE/U-30/2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹99,680
30 May 2026
24 Apr 2026
18 May 2026
24 Apr 2026
15 May 2026
8 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Supply and fixing in replacement of MCCB, 4 pole, 415 volt of capacity 630 amp,Ics=50%Icu short circuit, breaking capacity not less than 50 KA , thermal setting 80 to 100 % confirming to IEC-947, IS-13947 , including thimbles, nuts, bolts ,washers etc disconnecting and making incoming , out going connections complete all as specified and directed by Engineer-in-Charge. | - | Each | - | - |
| - | Supply and fixing in replacement of MCCB, 3 phase, 4 pole, 415 volts of capacity 400 Amps, breaking capacity not less than 35/36 KA, thermal setting 80-100%, Ics=100% Icu conforming to IEC-947, IS-13947 including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and directed by Engineer-in-Charge. | - | Each | - | - |
| - | Description all as per Ser item No 2.00 here-in-before, but capacity of MCCB 250 Amps 25 KA | - | Each | - | - |
| - | Description all as per Ser item No 2.00 here-in-before, but capacity of MCCB 200 Amps 25 KA | - | Each | - | - |
| - | Description all as per Ser item No 2.00 here-in-before, but capacity of MCCB 160 Amps 25 KA | - | Each | - | - |
| - | Description all as per Ser item No 2.00 here-in-before, but capacity of MCCB 100 Amps 25 KA | - | Each | - | - |
| - | Description all as per Ser item No 2.00 here-in-before, but capacity of MCCB 63 Amps 25 KA | - | Each | - | - |
| - | Supply and fix MCB TPN 415 volts 63 amps with 10KA breaking capacity complete all as specified and directed by Engineer-in-Charge. | - | Each | - | - |
| - | Supply and fixing in replacement of Air Circuit Breaker 415V Microprocessor based SR18G release of capacity 2000A 4P 50K MDO rated current at 50°C conformance to IS/IEC 60947-2 & IEC 60947-2. ACB should have High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity and Having Electromechanical operation not less than 20000. ACB Should have overload phase protection, overload Neutral, short circuit, instantaneous,earth fault & individual fault LED indication complete all as specified and directed by Engineer-in-Charge. | - | Each | - | - |
| - | Supply and fixing in replacement of Air Circuit Breaker 415V Microprocessor based SR18G release of capacity 1600A 4P 50K MDO rated current at 50°C conformance to IS/IEC 60947-2 & IEC 60947-2. ACB should have High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity and Having Electromechanical operation not less than 20000. ACB Should have overload phase protection, overload Neutral, short circuit, instantaneous, earth fault & individual fault LED indication complete all as specified and directed by Engineer-in-Charge. | - | Each | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TENDER30.pdf
Tender Documents • 1.29 MB
BOQ_853437.xls
BOQ • 7.43 MB
Amendmenttodate.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .