| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹46.5 L+₹2.5 L (5.77%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹47.3 L+₹3.3 L (7.53%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹48.2 L+₹4.2 L (9.60%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹48.5 L+₹4.6 L (10.4%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹44.6 L
EMD Value
₹89,160
Closing Date
28 Nov 2023, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR/MAINT OF INTERNAL ELECTRIFICATION INCL WIRING, LIGHTNING FIXTURES, CEILING/EXHAUST FANS, WALL MOUNTED/PEDESTAL FANS INCL ATTENDING DAY TO DAY COMPLAINTS FOR NEWLY TAKEN OVER BLDNGS FROM CCE RND AT DRDL/ASL AREA UNDER GE (I) RND KBAGH, HYD
2023_MES_627515_1
GE I KBAGH TOKEN 94 OF 2023 2024
Open Tender
Civil Works
Item Rate
240 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹89,160
Yes
29 Jan 2024
8 Nov 2023
30 Nov 2023
8 Nov 2023
28 Nov 2023
22 Nov 2023
8 Nov 2023 - 15 Nov 2023
Amount
Repair / maintenance of internal/Building light fittings of any type like tube lights / wall bracket light fittings / ceiling lights / mirror lights/ high& Medium bay lights in its position, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like, tube rod, side holders, holders, lamps etc all as directed by Engr-in-charge. Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like, capacitor, lamp holder, connector, connection wire,LED tube, Bulbs etc, replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor's supervisor representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following day before 0900hrs to the JE E/M.
(iv) The contractor has to rectify the defects and make the light fittings functional within 24 hours from the time the list of defective lights is handed over to him / his rep by the concerned JE E/M. In case the light fitting is not made functional for whatsoever reason within the specified time limit, an amount of Rs 50/- per such defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall engage separate team of technicians / repairer at newly under taken buildings from CCE R&D. (v) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every light fitting and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below. (vii) The contractor should submit the copy of qualification, Experience as Electrician and police verification certificates while sigining the site orders. (viii) The contractor is fully responsible for providing the safety standards to be maintained by the electricians while attending the electrical defects.
S&F LED tube 20Watt, 6500K CCT,proffesional luminaries with luminous efficiency not less than 120Lm/watt, Single side connection with < 10% THD. Make: Havells/Polycab/Philips/Wipro
S&F in replacment indoor industrial type surface/wall mounted LED integral batten 20W, 6500K CCT, aluminium extruded body and polycarbonate diffuser, <10%THD, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete removing unserviceable fittings all as specified and directed. . Make : Havells/Polycab/Philips/Wipro
S&F in replacment LED PLL lamp Hercules 18Watt, proffesional luminaries single side connection with < 10% THD. Make: Havells/ Jaquar/Crompton/Polycab/wipro
S&F in replacment indoor industrial type recess mounted LED Surface mounted for POP ceiling round downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency.15W, 6500K CCT, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable as required at site with suitable size complete removing unserviceable fittings all as specified and directed Make: Havells/ Jaquar/Crompton/Polycab/wipro
S&F in replacment indoor industrial type recess mounted LED Surface mounted for Recessed Mounting ceiling round downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency.15W, 6500K CCT, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable as required at site with suitable size complete removing unserviceable fittings all as specified and directed Make : Make:Havells/ Jaquar/Crompton/Polycab/wipro
Supply & Fix in replacement recess mounted LED luminaire 36W 2'x2' , 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for Grid ceiling or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size including making good to the disturbed portion of ceiling complete removing unserviceable fittings all specified and directed. Make:Havells/ Jaquar/Crompton/Polycab/wipro
Supply & Fix in replacement recess mounted LED luminaire 36W 2'x2', 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for POP ceiling or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size including making good to the disturbed portion of ceiling complete removing unserviceable fittings all specified and directed. Make: Havells/Jaquar/Crompton/Polycab/wipro
Supply & Fix recess mounted LED luminaire 36W 4'x1' of size 1195x295x70 mm, 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for Armstrong/ US Gypsum or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size including making good to the disturbed portion of ceiling complete removing unserviceable fittings all specified and directed. Make:Havells/ Jaquar/Crompton/Polycab/wipro
S&F in replacement recess mounted LED high bay light with IP-66 protection pressure die cast body with high power SMD LEDs as light source of luminous efficacy 150lm/watt 120W, 240V, 5000K CCT, aluminium heat sink alongwith inbuilt elctronic driver, wide beam angle , including hanging the fitting with required hook arrangement required at site. Make:Havells/ Jaquar/Crompton/Polycab/wipro
S&F in replacement LED security light fiitting of luminous capacity 2500lumens,IP-66 protection, 5700K CCT, inbuilt electronic driver with <10%THD made up of die cast alluminium housing with high power LED as lighting source and lens embeded toughned glass cover, separate driver compartment complete fixing with GI bracket made out of 40mm bore GI pipe light grade 1.5Mtr long bend to shape and fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed by Engr-in-charge. Make:Havells/ Jaquar/Crompton/Polycab/wipro
Material and Labour for sub main wiring with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof, floors etc including one run of 2.5 Sqmm PVC copper conductor as earth continuity wire including taking down unserviceable sub main wiring including conduit all as specified and directed. Note : 2 Runs of 2.5 sqmm cable 1 run of 2.5 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment.
All as per srl item No. 12 here-in-before but with 2 runs 4 sqmm including 1 run of 4 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia ISI marked PVC conduit.. Note : 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment.
All as per srl item No. 12 here-in-before but with 2 runs 6 sqmm including 1 run of 6 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia PVC conduit. Note : 2 Runs of 6 sqmm cable 1 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit for the purpose of payment.
All as per srl item No. 12 here-in-before, but sub main wiring with 4 runs of 4sqmm with 2 run of 4 sqmm copper conductor FRLS as earth continuity wire in not less than 25mm dia PVC conduit. Note : 4 Runs of 4 sqmm cable 2 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment.
Material and Labour for sub main wiring with 4 runs of 6 Sqmm single core ISI marked PVC insulated unsheathed cable 1100 Volts grade multistranded copper conductor cable drawn through in and including surface/concealed rigid PVC conduit medium grade of size not less than 25mm dia and conduit accessories such as bends, tees, junction boxes type on walls, roof, floors etc.. including providing 2 runs of 6 Sqmm PVC insulated unsheathed multistranded FRLS copper conductor cable as earth continuity conductor and connecting to earth dolly wire including taking down unserviceable sub main wiring and conduit all as specified and directed. Note :- 4 Runs of 6 sqmm cable 2 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit. Make for Item No 12 to 16 : For Copper wire : Finolex/Nicco/Havells/Gloster/KEI For PVC conduit : Sudhakar/Polyplast/Supreme/GM Make of Gang Boxes: GM/Havells/Legrand
S&F point wiring for one 5amp socket outlet same board/5amp socket outlet independant board point, controlled by one, one way switch with 1.5 sqmm size, PVC insulated and 1100 volts grade, single core (multistrand) copper conductor (FRLS) cable drawn into & including existing conduit and terminal boxes and matching the same with existing surface for mounting fittings like switches, sockets & fan regulators etc with 3mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 sqmm multistranded FRLS copper conductor cable earth wire and connected to earth dolly complete all as specified and directed, are as follows :-
One light /one fan/one bell point controlled by one switch.
One socket outlet 5 pin 5 amps controlled by one switch on same board.
One socket outlet 5 pins 5 amps controlled by one switch on independent board.
All as per item No. 17 here-in-before but wiring with 4.00 Sqmm for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 4 Sqmm PVC insulated multi stranded copper earth continuity conductor and connected to common earth dolly. Make For Copper wire : Finolex/Havells/Gloster/KEI. For PVC conduit :Sudhakar/Polyplast/ GM/Modi. NOTE : The Contractor is responsible for arranging all tools required at site.
Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:-
One light/ fan point controlled by one, one way switch
One light point controlled by one, two way switch
One 5 Amps socket point on independent board.
One 5 Amps socket point on same board with other switches
All as per item No. 18 here-in-before but wiring with 2.5 Sqmm FRLS for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 4 Sqmm PVC insulated multistranded FRLS copper earth continuity conductor and connected to common earth dolly.
All as per item No. 18 here-in-before but wiring with 4.00 Sqmm FRLS for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 4 Sqmm PVC insulated multistranded FRLS copper earth continuity conductor and connected to common earth dolly.
PVC / polycarbonate Angle/Batten type lamp holders retrofit type. Make: Anchor/GM/Cona
S&F in replacement for white cover plate with frame 8 module.
S&F in replacement for white cover plate with frame 6 module.
S&F in replacement for white cover plate with frame 4 module.
S&F in replacement for white cover plate with frame 3 module.
S&F in replacement for Modular socket 6A 2/3 Pin 2 module.
S&F in replacement for Modular socket 16A 2/3 Pin 2 Module.
S&F in replacement for modular switch 1 way 6A 1 module.
S&F in replacement for modular switch 1 way 16A 1 module.
S&F in replacement of modular fan regulator 120W,240V, 2module, suitable for ceiling fan of 1200/1400mm sweep.
S&F in replacement of modular fan regulator 120W,240V, 1 module, suitable for ceiling fan of 1200/1400mm sweep.
S&F in replacement for modular switch 2 way 6A 1 module. Make of item No 20 to 30: L&T/Schneider/Crabtree
S & F in replacement of switch piano flush type 5 Amps SP one way all as specified. Make:-Anchor/Cona/GM
S & F in replacement of switch piano flush type 15 Amps SP one way all as specified. Make:-Anchor/Cona/GM
S&F in replacement of fan regulator 120W,240V, switch type suitable for ceiling fan of 1200/1400mm sweep.
S&F in replacement of fan regulator 120W,240V, socket type suitable for ceiling fan of 1200/1400mm sweep.
S & F in replacement of socket combination 5 Amps flush mounted 3/5 pin multi purpose all as specified. Make:-Anchor/Cona/GM
S & F in replacement of socket combination 5/15 Amps flush mounted 3/5 pin multi purpose all as specified. Make:-Anchor/Cona/GM
Supply and fix in replacement MCB DB 08 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed . Make: Legrand/ Schneider/L&T/C&S
Supply and fix in replacement MCB DB 04 way SPN (single door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed . Make: Legrand/ Schneider/L&T/C&S/Havells
Supply and fix in replacement MCB DB 12 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells
Supply and fix in replacement VTPN DB 04 way (double door) sheet metal enclosure factory made suitable for MCCB 415 volts incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells
Supply and fix in replacement MCB TPN DB 04 way (double door) sheet metal enclosure factory made suitable for MCB TPN incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells
Supply and fix in replacement VTPN DB 08 way (double door) sheet metal enclosure factory made suitable for MCCB 415 volts incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells
Supply and fix in replacement VTPN DB 12 way (double door) sheet metal enclosure factory made suitable for MCCB 415 volts incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make : Legrand/L&T/Schneider/Havells
Supply and fix in replacement of MCB single pole 6-32 Amps working on 240 volts, 50 HZ AC, 10 KA 'C' curve all as specified and directed. Make: Legrand/C&S/L&T
S&F in replacement of MCB SPN 32-40 Amps working on 240 volts, 50 HZ AC, 10 KA 'C' curve all as specified and directed. Make: Legrand/C&S/L&T/Havells
S&F in replacement of MCB TP 40 Amps working on 415 volts, 50 HZ AC, 10 KA ,'C' curve all as specified and directed. Make: Legrand/C&S/L&T/Havells
S&F in replacement of MCB TPN 63 Amps working on 415 volts, 50 HZ AC, 10 KA ,'C' curve all as specified and directed. Make: Legrand/C&S/L&T/Havells
Supply & Fix in replacement PVC insulated round cable 3 core stranded copper conductor 2.5 sqmm as in connection cord. Make : Polycab / Havells/Paragon/ Plaza
Supply and fix in replacement metal clad plug top 3 pin, 20 amps, ISI marked heavy duty for AC connection cord. Make:Legrand/Havells/Scheinder
Supplying and fixing 1100 volts grade cable PVC insulated copper strandard conductor cable of size 1.5 sqmm flat or circular complete all as specified and directed. Make : Havells/Finolex/Plaza
All as per item No. 50 above but of size 2.5 sqmm
All as per item No. 50 above but of size 4.0 sqmm
All as per item No. 50 above but of size 6.0 sqmm
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed by Engr-in-Charge.
M&L for testing of old earthing using calibrated earth tester and submitting result to Engr-in-Charge. Earthing which showing much more result as specified as directed and disconneted should replaced with new earthing items are considered as below :- Note :- (i) Watering of earthing with 2 bucket 30 ltrs water mixed with salt (Total 5 Kg) shall be carried out one day before the testing and the cost of the same shall deemed to be included in quoted rate.
S&F/lay GI earth wire 4 mm dia on walls/floor as earth continuity conductor connected to DBs/ panels etc.
Supply and Fix GI tubing 15mm dia light grade for protection of GI earth wire complete all as specified and directed.
S&F in replacement MCCB with rating of 100Amps,415Volts 4pole with 16 kA breaking capacity,thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be 100% of ultimate breaking capcity(Icu) with inbuilt Display for Current Metering with accuracy of class 1. MCCB should be with suitable spreaders and phase barriers for each terminals with all accessories all as specified and directed. Make : Legrand/L&T/Schneider/Havells/Havells
All As per item No :58 above but 160Amps, 4 pole, 36 KA. Make : Legrand/L&T/Schneider/Havells/Havells
S&F in replacmenet MCCB with rating of 63Amps,415Volts 4pole with 16 kA breaking capacity,thermal magnetic adjustable of overload & fixed short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be 100% of ultimate breaking capcity(Icu) . MCCB should be with suitable spreaders and phase barriers for each terminals with all accessories all as specified and directed. Make : Legrand/L&T/Schneider/Havells/Havells
All As per item No :60 above but 125Amps, 4 pole, 16 KA. Make : Legrand/L&T/Schneider/Havells/Havells
Taking down ceiling fan/exhaust fan/ wall mounted fan / Air circulator fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as directed. Note : Cost of spares such as capacitors, bearings, Shaft etc will be measured and paid for separately under respective Item of sch A as supply only.
Supply only capacitor of 2.5 mfd for ceiling fan/exhaust fan. Make: Epcos/Havells/Tibcon
Supply only capacitor of 4 mfd for air circulator/exhaust fan. Make: Epcos/Havells/ Tibcon
Supply only aluminium fan blade for exhuast fan of any sweep/make as per the sample given by the Engineer-in-charge.
Supply only bearing No.6201/6202/6203/6204 or any other No matching to the existing size and suitable for ceiling fan/exhaust fan/wall mounted fan. Make: SKF/TATA/ARB
Supply only carbon steel shaft as suitable for ceiling fan/Exhuast fan/ Pedestal Fan/ Air Circulator fans matching to the existing size.
Disconnecting electric connection and taking down carefully fan of any type and size/sweep as described below, removing the burnt winding of fan motor and cleaning the startor completely removing the burnt sludges from the slots and rewinding with super enameled copper winding wire of suitable gauge or of matching size to the existing wires with same turns ratio including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and refixing to original position all as directed by Engineer-in-charge.
Celling fan of size 1200/1400mm sweep.
Air circulator fans size 600 mm sweep wall mounting Oscillating type
Wall mounted/Pedstal fans size 350/450 mm sweep Oscillating.
Exhaust fan of 350/450 mm sweep.
Preparation of old surface of exhaust fan of any sweep by removing old paint using paint remover or by burning off using blow lamp and cleaning with cloth and Spray painting complete exhaust fan with superior quality synthetic enamel paint (Smoke grey) after applying a single coat of primer complete all as directed.
All as per sl item No. 69 above but wall mounted/ Air circulator/Pedestal of size 450/600 mm sweep with superior quality enamel paint (Half white) complete all as directed.
All as per sl item No. 69 above but Ceiling fan of size 1200/1400 mm sweep with superior quality enamel paint ( Half White) complete all as directed.
Material and labour for fixing metal pulg and socket DB for AC connecton (AC box) complete with all accessories etc all as directed. Make: Havells/Legrand/Polycab/Wipro
Supply and Fix in replacement recess mounted LED Flood light with IP-66 protection pressure die cast body with high power SMD LEDs as light source of luminous efficacy 150lm/watt 120W, 240V, 5000K CCT, aluminium heat sink alongwith inbuilt elctronic driver, wide beam angle , including hanging the fitting with required hook arrangement required at site. Make: Havells/ Jaquar/Crompton/Polycab/wipro
Supply and Fix in replacement recess mounted LED Flood light with IP-66 protection pressure die cast body with high power SMD LEDs as light source of luminous efficacy 150lm/watt 80W, 240V, 5000K CCT, aluminium heat sink alongwith inbuilt electronic driver, wide beam angle, including hanging the fitting with required hook arrangement required at site. Make: Havells/ Jaquar/Crompton/Polycab/wipro
S.S.ENGINEERING CORPORATION
UNITY ENGINEERING TRADERS
Richcon Engineers
SUN LIGHT HOUSE
Bismi Engineering
BHAGYARAM ENTERPRISES
Venkat Sai Enterprises
Anjana corporation
ELEVATORS MAINTENANCE ENGINEER WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .