Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-Finance | ₹5.8 L | L1 | Accepted-Finance First Lowest |
| 2 | L2₹6.0 L+₹15,452.96 (2.64%)Accepted-Finance | ₹6.0 L+₹15,452.96 (2.64%) | L2 | Accepted-Finance Being L2 |
| 3 | L3₹6.1 L+₹26,559.78 (4.55%)Accepted-Finance | ₹6.1 L+₹26,559.78 (4.55%) | L3 | Accepted-Finance Being L3 |
| 4 | L4₹6.5 L+₹66,640.89 (11.4%)Accepted-Finance | ₹6.5 L+₹66,640.89 (11.4%) | L4 | Accepted-Finance Being L4 |
| 5 | L5₹7.0 L+₹1.2 L (19.8%)Accepted-Finance | ₹7.0 L+₹1.2 L (19.8%) | L5 | Accepted-Finance Being L5 |
Tender Value
₹9.7 L
EMD Value
₹19,316
Closing Date
29 May 2026, 10:00 amClosed
Executive Engineer
EE,EandM, Division, APWD, Prothrapur
Repair and Renovation of 10 Nos. Type -II Quarters under Fire Service at PS Teylorabad Quarter Complex under EandM Sub Division No-I, APWD, Prothrapur SW Providing IEI
2026_APWD_23105_1
NIT No 20/EE/EandM/26-27
Open Tender
Electrical Works
Percentage
45 days
South Andaman
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹19,316
29 May 2026
23 May 2026
29 May 2026
23 May 2026
29 May 2026
26 May 2026
23 May 2026 - 26 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
a) Group A ( 10 x 19 = 190) | 190 | Point | 1,006 | ₹1,91,140 |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. ( 10 x 4 = 40) | 40 | Point | 1,414 | ₹56,560 |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (10 x 35 = 350) | 350 | Mtr | 290 | ₹1,01,500 |
| 4.1 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (10 x 40 = 400) | 400 | Mtr | 212 | ₹84,800 |
| 4.2 | b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (10 x 5 = 50) | 50 | Mtr | 361 | ₹18,050 |
| 5 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
(10 x 4 = 40) | 40 | Each | 413 | ₹16,520 |
| 6 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. (10 x 3 = 30) | 30 | Each | 589 | ₹17,670 |
| 7 | Supplying, Installation, Testing and Commissioning of 28W BLDC Ceiling Fan 1200mm Sweep ISI Marked without regulator will all accessories Make Havells: Model No. Efficiencia DX BLDC or its equivalent(ISI Marked and BEE 5 Star Rated) power consumption with switch control, 5 years warranty etc., as required. (10 x 3 = 30) | 30 | Each | 5,359 | ₹1,60,770 |
| 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
(10 x 3 = 30) | 30 | Each | 496 | ₹14,880 |
| 9 | Supplying of Exhaust Fan (Non Metallic Type) 250mm Sweep with accessories etc as equivalent to Havells Ventil Air DX or its equivalent etc., as required. (10 x 2 = 20) | 20 | Each | 2,612 | ₹52,240 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.28 MB
TenderDocument20.pdf
Tender Documents • 1.55 MB
Instructions-to-bidders.pdf
Other Documents • 0.33 MB
BOQ_24493.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .