Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC SHIVSHAI PUNARVASAN PRAKALP BLDG NO 10 ROOM NO 115 MAHARASHTRA NAGAR MANKHURD E MUMBAI 400088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | ₹49.4 L Quoted ₹50.4 L | L1 | Accepted-AOC AOC |
| 2 | L2₹51.3 LRejected-Finance ROOM NO B 111 PART III GANESH MURTINAGAR CAPT PRAKASH PETHE MARG CUFFEPRADE CALABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹51.3 L | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹52.4 LRejected-Finance 38 BAGUIATI ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | ₹52.4 L | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹52.5 LRejected-Finance P 45 JOGENDRA GARDEN KOLKATA 700078 | KOLKATA | WEST BENGAL | 700078 | ₹52.5 L | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹53.9 LRejected-Finance 7 11 1 BROJONATH LAHIRI BISHNUPUR SOUTH 24 PGS WEST BENGAL 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | ₹53.9 L | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/S L.R.ENTERPRISES L8 | AZIM ENTERPRISES L1 | M/S SRINIVASA CONSTRUCTION L2 | DGR CONSTRUCTION L6 | Piu Projects L7 | HYDROTEC L4 | SK CONSTRUCTION SYNDICATE & ENGG CO L5 | MODERN AGENCY L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. | 435 | Sqm | 35 ₹15,225 | 30 ₹13,050 | 30 ₹13,050 | 35 ₹15,225 | 35 ₹15,225 | 32 ₹13,920 | 34 ₹14,790 | 35 ₹15,225 |
| 2.00 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface in CM (1:4) & water proofing compound mixed with second layer @200 ml/Bags finished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separetly.) | 150 | Sqm | 292 ₹43,800 | 265 ₹39,750 | 280 ₹42,000 | 285 ₹42,750 | 290 ₹43,500 | 283 ₹42,450 | 288 ₹43,200 | 270 ₹40,500 |
| 3.00 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished rendering surfaces even and smooth (without using extra cement) complete all as specified and directed. | 120 | Sqm | 267 ₹32,040 | 240 ₹28,800 | 250 ₹30,000 | 255 ₹30,600 | 260 ₹31,200 | 253 ₹30,360 | 266 ₹31,920 | 240 ₹28,800 |
| 4.00 | M&L rendering 10 mm thick in CM 1:3 on concrete as in ceiling/landing etc on concrete surface finish even and smooth without using extra cement with and including taking down cement or lime plaster of any description complete all as specified and directed by Engr-in-Charge. | 25 | SQM | 260 ₹6,500 | 225 ₹5,625 | 240 ₹6,000 | 245 ₹6,125 | 250 ₹6,250 | 244 ₹6,100 | 255 ₹6,375 | 230 ₹5,750 |
| 5.00 | Supplying Integral water proofing compound. | 1.51 | Ltr | 282 ₹424.69 | 290 ₹436.74 | 280 ₹421.68 | 285 ₹429.21 | 280 ₹421.68 | 282 ₹424.69 | 279 ₹420.17 | 290 ₹436.74 |
| 6.00 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. | 9.5 | Cum | 9,002 ₹85,519 | 780 ₹7,410 | 750 ₹7,125 | 755 ₹7,172.50 | 800 ₹7,600 | 755 ₹7,172.50 | 799 ₹7,590.50 | 800 ₹7,600 |
| 7.00 | M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. | 6 | Cum | 9,002 ₹54,012 | 8,500 ₹51,000 | 8,600 ₹51,600 | 8,605 ₹51,630 | 8,800 ₹52,800 | 8,650 ₹51,900 | 8,799 ₹52,794 | 8,500 ₹51,000 |
| 8.00 | M&L brick work with Fly ash bricks' old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed. | 30 | Sqm | 955 ₹28,650 | 900 ₹27,000 | 930 ₹27,900 | 933 ₹27,990 | 950 ₹28,500 | 933 ₹27,990 | 949 ₹28,470 | 920 ₹27,600 |
| 9.00 | M&L for 15mm thick cement plaster in cement mortar 1:4 on bricks or concrete surface and finished even and smooth without using extra cement including necessary scaffolding workall as specified and directed by Engr -in-Charge. | 40 | Sqm | 282 ₹11,280 | 245 ₹9,800 | 260 ₹10,400 | 263 ₹10,520 | 280 ₹11,200 | 263 ₹10,520 | 278 ₹11,120 | 250 ₹10,000 |
| 10.00 | M & L two coat of oil bound distemper on newly plastered surface of wall, by brush and roller including over of one coat white chalk on wall complete all as directed by Engr-in-charge. | 160 | Sqm | 75 ₹12,000 | 70 ₹11,200 | 70 ₹11,200 | 73 ₹11,680 | 75 ₹12,000 | 74 ₹11,840 | 73 ₹11,680 | 72 ₹11,520 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
3 Oct 2025, 6:00 pmClosed
Garrison Engineer (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPECIAL REPAIRS / REPLACEMENT OF ROOF SHEET OF GARRAGES, PROVN OF CABLE TRAYS AND AREA LIGHTINGS AND ADDN/ ALTN OF ORs TOILET AT INSIDE VIJAY DURG UNDER GE (FW) KOLKATA
2025_MES_730593_1
8482/E8
Open Tender
Civil Works - Canal
180 days
Garrison Engineer (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (FW) Kolkata
₹92,000
28 Mar 2026
12 Sept 2025
4 Oct 2025
12 Sept 2025
3 Oct 2025
25 Sept 2025
Amount
Taking down cement plaster on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface in CM (1:4) & water proofing compound mixed with second layer @200 ml/Bags finished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separetly.)
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished rendering surfaces even and smooth (without using extra cement) complete all as specified and directed.
M&L rendering 10 mm thick in CM 1:3 on concrete as in ceiling/landing etc on concrete surface finish even and smooth without using extra cement with and including taking down cement or lime plaster of any description complete all as specified and directed by Engr-in-Charge.
Supplying Integral water proofing compound.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L brick work with Fly ash bricks' old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed.
M&L for 15mm thick cement plaster in cement mortar 1:4 on bricks or concrete surface and finished even and smooth without using extra cement including necessary scaffolding workall as specified and directed by Engr -in-Charge.
M & L two coat of oil bound distemper on newly plastered surface of wall, by brush and roller including over of one coat white chalk on wall complete all as directed by Engr-in-charge.
M/L for complete removal of existing treatment, washing, rubbing down and stopping of painted/treated surfaces and applying two coat of oil bound distemper by brush and roller including over one coat of chalk whitening on wall complete all as directed by Engr-in-charge.
M&L for applying two coats of oil bound distemper to old decorated surfaces of ceiling including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed.
M&L for applying two coats of oil bound distemper to new surfaces of ceiling including preparation of surface complete all as specified and directed.
M & L Preparation of new plastered surfaces of walls and soffits of Chajja, roof slab etc and applying two coat of weather proof exterir emulsion paint of approved make using airless sprey technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for building hight complete all as spcified and directed.
M & L Preparation of old treated/ painted surfaces of walls and soffits of Chajja, roof slab etc, by cleaning brooming, rubbing and scrapping as required using broom, emery paper, putty blade/ scraper as applicable to make the surface free from loose paint, algae formation dust etc including necessary safety & protective measures such as safety belt, headgear etc including filling cracks upto 5mm with and including suitable elastomeric crackfill paste and applying two coat of weather proof exterir emulsion paint of approved make using airless sprey technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for building hight complete all as spcified and directed.
M & L applying one coats of synthetic enamel paint on old painted surface wooden surfaces of any description over 10 cm width or girth complete all as specified and directed.
M & L preparation applying one coats of synthetic enamel paint on old steel serface of any description over 10 cm width or girth complete all as specified and directed.
M & L applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed.
M & L applying two coats of synthetic enamel paint on steel surfaces of any description/new over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete all as specified and directed.
Demolition of cement Concrete(reinforcement cut as required to facilitate demolation) Roof, floors (other than ground floors), beams, staircase, landing, chajjas and similar suspended work complete all as specified and directed.
M & L RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall,beam and columns in floor, roof landing,, balconies,conopies, deck slab and shelves etc complete all as specified and directed.
M&L for RCC (nominal mix ) type B1 1:2:4 (20 mm graded aggregate) in Roof Beams, cantilevers, bressummer, lintels over 1.5 span complete all as specified and directed.
Use and waste of formwork to sides and soffits of suspended slabs, floor slab, landing and similar work n. exc. 200 mm thick rough finished on flat surfaces of concrete complete all as specified and directed.
S & F mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
S & F mild steel deformed bar 6 to 8 mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L non skid ceramic colour tiles of area of each tile exc 0.18 Sqm but n exc exc 0.38 Sqm and 6 to 7 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement complete including 15 mm thick screed bed cement mortar 1:6 complete all as specified and directed. all as specified and directed .
M&L non skid ceramic colour tiles of area of each tile exc .18 Sqm but n exc exc .38 Sqm and 6 to 7 mm thick, as in skirting /dado, set and jointed in neat cement slurry and pointed in coloured cement complete including 10 mm thick screed bed cement mortar 1:4 complete all as specified and directed. all as specified and directed .
M & L glazed ceramic colour tiles size 450 mm x 300 mm x 6 to 7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement including 10 mm thick plastering in cement mortar 1:4 complete all as specified and directed. to match complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.
M & L for 20 mm thick screed bed or bedding layer of mortar as in backing coat of stone on fair face of brick wall or concrete surface in cement mortar 1:4 complete all as specified and directed.
M&L Granite (of any type) slab 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete and like over and including 20mm thick cement mortar bedding (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified. (upto 04 storey High of building)
Dismantling of plain or corrugated sheeting , any guage, thickness and including Naintital or similar pattern roof coverings complete all as specified and directed.
S & F pre-painted galvatume aluminium zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
S & F pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges , valley gutter, Sun shed etc fixed with self tapping screws as specified.
Dismantling Structural steel wok incl grills ,gates, stair case etc but excluding framed truss in any postion complete all as specified and directed.
Supply and fixing for structural steel work Fe 410-W (Gde-E-250) rolled mild steel in joist, channel, angle or Tee section fixed independently etc up to height 4 to 6 mtr from each floor level (cut to ordinary length ie. Within 20mm of the length indicate) Gde Fe-410-W-(Gde-E-250) Quality-B including using former iron props and steel plates to existing RCC over head members like beams, slabs etc so as to ensure safety of existing structure and floor during repairing works complete all as directed by Engr-in-Charge. Note: The section to be provided under this item will be used as beam to support floor/roof.
S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and directed.
Taking down chowkhats or frames not exc 1.5 sqm each (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutter from the frame) complete all as specified and directed.
S&F 2nd class hard wood plain solid straight chowkats and frames,wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified and as directed.
S &F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 30 mm thickness 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkat all as specified.
S&F, Powder coated aluminium sliding window with shutter styles 40mm x20 mm sheet thickness 1.5mm Two shutter of glass and one shutter of wire mesh consisiting of Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, frame (chowkat) of window shall 100mm x 44mm x 1.5mm thick section with or without rebate 5 mm thick tinted glass fixed with aluminium beads locking arrangement with each shutter all as directed by the Engineer-in-Charge. Note: 1) Size of window shall be as per site requirement. 2) Glass and wire cloth shall be measured seperately.
S & F powder coating of any colour (Thickness or powder coating not less than 50 micron). Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S & F 4 mm thick plain sheet glass ordinary quality and glazing with oil putty or wooden beads in square area not exc. 0.5 Sqm in each pane complete all as specified and directed.
S & F 4 mm thick Frosted plain glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified and directed.
Supply & fixing 100 mm stainless steel butt hinges (medium weight) cold rolled complete all as specified and directed.
S & F aluminium handles 150 mm long cast type, anodised complete all as specified and directed.
S & F aluminium anodised barrel tower bolts 150 mm long of extruded section and fixed complete all as specified and directed.
S & F 300 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete all as specified and directed.
Supply and fixing stainless steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.4 mm complete all as specified and directed.
Supply and fixing in repair stainless steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.4 mm complete all as specified and directed.
S &F framed work such as grills, grating etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barried iron doors ladders framed balusters, walk ways, railing framedwork of water tanks and similar work conforming to Fe.290 Gde E-165 complete all as specified and directed.
Chipping of unsound weak concrete materials including cover platster from RCC structural member i.e.slabs, beams,colums ,lintel,chajja ,fin, facia, etc 25mm avarage thickness including tapering all edges making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materilas by air blasting or sand blasting including foreign materilas ,loose concrete /aggregate etc and disposal of all debris outside of MOD land and complete all as specified and as directed by Engr-in-charge.
Material and labour of applying chloride free rust removing chemical on resting structural member and removing all rust from steel surface member by emery paper and cleaning the area throughly by water and allow it to dry and totally rust free of steel surface member and application two component epoxy zinc-rich primer over treat steel surface of minimum specific 1.75, adhesive bond strength with steel is 1.50N/mm2 all as complete as per manufacturer's instruction as specified and as directed. ( Make: Rust removing chemical) Reebaklens RR for rust remover Nitozinc primer for primer of FOSROC or equivalents solutions SIKA/BASF/STP as approved by GE.
Material and labour for introducing new reinforcement bars upto 12mm dia for structural connection in RCC beams, columns lintel and slabs including power drilling holes of appropriate diametres in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power driling fixing the reinforcemnt in postion using epoxy cleaning of loose dust by blowing air sealing with epoxy cartidges etc all as specified and directed.
Material and labour for mixing and application of two compentent structural grade polymer modified reinstatement mortar where local spalling has taken place or shuttering is not possible. The mortar can be applied in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimum compressive strength 12N/mm2 in 1 day and 45M/mm2 in 28 days Minimum flextural strength should be 8N/mm2 in 28 days .A modified styrene styrene butadience emulsion for use as a bonding aid and gauging liquied for cementious system to be mixed with cement slurry before the application of micro concrete to be used @6 litre/bag of cement. The bonding agent should have minimum compressive strength 24N/mm2. The minimum tensile strength 3.5 N/mm2 minimum flexural strength 6.5 N/mm2 up to 25 mm average thickness up to any storied of bldg complete all as specified ans as directed. ( Make: Fosrce/Pidilite/ STP/BASF/SIKA/Supreme Bituchem India P. Ltd)
Demolition of cement concrete (un-reinforced) not exc and out compete existing roof treatment from roof surface & roughening of old concrete floor surfaces including cleaning the roof surfaces by brushing sweeping etc and removing rubbish material complete all as specified and directed.
M & L for rendering 10mm thick on fair faces of concrete surfaces in cement mortar 1: 4 under APP membrane finish rendering surfaces even and smooth with out using extra cement mixed with WPC @2% by weight of cement or as per manufacturer instruction. Complete all as specified and directed (Note:- WPC shall be mesured and paid separately)
M&L for providing 25mm thick PCC (1:2:4) type 'B-0' (using 12.5mm graded crushed stone aggregate) after applying cement slurry @ 3 Kg/sqm, on top of roof, mixed with water proofing compound @ 200 ml per bag of cement, surface finished even and smooth without using extra cement including complete all as a specified and as directed.
M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as a specified and as directed.
M & L for brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as a specified and as directed.
M & L for for water proofing treatment on existing cleaned RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:- (a) Preparing and clening of fully dry surfaces as per IS3067-1966 (b) Applying bitumen primer conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm (c) Applying a layer of APP based polymeric membrance 3.0mm thick (minimum) weight 3.0Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane.
Demolition of cement concrete (un-reinforced) not exc 15cm thick in ground floor and paving (below or above ground level) complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays, surface finished even and fair without using extra cement complete all as specified and directed.
M & L for heavy duty coloured ceramic floor tiles of size 300 x 300x 10 mm thick, suitable for high traffic external tiles, anti skid, scratch resistance and neutral to UV rays and acid alkali resistance as in floor including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. (MAKE : JOHNSON, Model : ENDURA or equivalent model in other makes listed in the tender)
M & L 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth using without extra cement complete all as specified and directed.
Supply and Fixing PVC solid wall lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturer’s specification and instruction and as directed .
Supply and Fixing 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
M&L 5 mm thick cement plaster on ceiling surfaces without using extra cement finishing fair and even in CM 1:3 including necessary scaffolding complete all as directed.
M&L for preparation of new plastered surfaces of wall/ceiling and applying two coat of acrylic distemper over a coat of alkali registant primer with 2mm thick wall care putty. complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building).
M&L for applying one coat of oil emulsion distemper to old decorated surfaces of wall/ ceiling including preparation surfaces (by brooming down steel wire brushing scrapping down smoke soot, moulds, moss, effoloresent, salts trading oil and greasy spots etc) complete all as specified and as directed by Engineer-in-Charge.
M & L for colour Glazed ceramic tiles in vertical surface 600 X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm backing coat in CM 1:4 etc complete all as specified and as directed
M&L for Prepolished Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 20mm thick cement mortar bedding (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granitecomplete all as specified and as directed
S&F powder coated anodised aluminium doors frame for doors, windows, ventilators and partition with one or more rebates ncluding necessary jointing cleats, glazing clips rubber packing cleat for fixing etccomplete all as specified and as directed
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer- in-charge.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat of size 45 x 85-90 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp- ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). → Note: For WPC solid door minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
S&F 200 mm long Aluminium anodised, barrel tower bolts of extruded section all as specified and as directed
S&F 125 mm long Aluminium handles, cast type, anodisedcomplete all as specified and as directed by Engineer-in-charge.
S&F 100 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and as directed. (upto 04 storey High of building)
M&L 25mm thick PCC 1:2:4 Type B-1 ( using 20 mm graded crushed stone aggregate) as in sub base of floor complete all as specified and as directed by Engineer-in-charge.. (upto 04 storey High of building)
Dismantling cast iron or re-inforced concrete drain pipes of 100mm bore, jointed in cement mortar complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
S&F sand cast pipes with out ears in any length fixed to wall with brackets of 100mm bore including bitummous paints both side complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
S&F CI bend,diminishing piece with door of 100mm borewith duct, foot and heel rest complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
S&F CI branch pieces single equal or unequal with door of 100mm bore complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
S/F CI cowl of 100mm bore complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
Taking down soil pipe/ rainwater pipes (any size or pattern ) including all fitings heads shoes bends swan -necks etc including cleaning or refixing or removal to store (measured over all fixed along the centre line over fitting and ( accessories)
S&F 110mm bore PVC(SWR) pipe single socket in any length rubber ring joints complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
S&F 110mm bore PVC(SWR) pipe bend single socket complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
M&L Preparing Old Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed.
S&F pre - painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as directed
M&L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
S & F MS angle,flats,etc independently fixed without connecting plates etc but ordinary length conforming to FE-410-W(Gde-E-250)quality A as in fencing posts including drilling holes for nuts and bolts and similar work complete all as specified and as directed.
S&F for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of grade Fe-410- W(Gde- E-250) quality- B complete all as specified and directed
Material and labour for providing Plain Cement Concrete (1:3:6) type C2 using 40mm graded aggregate as in foundation, filling and mass concrete all as specified and directed.
Forming fair finished drain or channel any inner girth in cement concrete, using extra cement, including forms, mould, mitred/stopped ends etc complete all as specified and as directed.
Add or deduct for 25mm girth or part there of over or under 30cm girth in cement concrete, using extra cement, including forms, mould, mitred/stopped ends etc complete all as specified and as directed.
M&L RCC 1:1½:3, type A1(NOMINAL MIX) (using 20mm grade stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
Formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. Rough finished surfaces of concrete flat all as specified and as directed by the Engineer-in-Charge.
Taking up or down steel tubing with connections for cleaning for refixing or removing or storeyard complete of bore 15mm. complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing with connections for cleaning for refixing or removing or storeyard complete of bore 20mm. complete all as specified and directed by Engineer-in-Charge.
S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore 15mm, complete all as specified and directed by Engineer-in-Charge.
S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs,unions etc.) of nominal bore 20mm, complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC low level flushing cistern valve less,syphonic action type of 10 ltrs capacity white with inlet, ball valve, float and handle incl. cast iron brackets, PVC flush pipe 32mm dia ,PVC connection (15x 450 mm) long, fancy type chromium plated angle valve of 15mm bore dia complete all as specified and directed by Engineer-in-Charge.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous china under counter / counter sunk wash hand basin white ,size 525x410x 210 mm , including PVC connection (15x450)mm long with PTMT nuts and PVC washer and including cutting for pinning in ends, and provision of PVC waste pipe 32mm of adequate length , CP waste coupling 32 mm dia of half or full threaded, chromium plated fancy type angle valve 15 mm dia bore, and taking down unserviceable wash hand basin complete all as specified and directed by Engr-in-charge.
S&F in repair vitreous china urinals,full stall type, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement with grating and union for discharge pipe, including PVC waste pipe 32mm of suitable length, CP waste coupling 32mm dia suitable for urinals, PVC connection 15x 450mm long ,CP urinal spreader,15 mm Angle valve fancy type chromium plated complete all as specified and directed by Engr-in-charge.
S&F in repair Vitreous china squatting pan 'Orissa' pattern ' size 580x440mm white, with integral foot rest 'P' or 'S' trap,front or back inlet including connection to trap and to flushing pipe,anti syphonage pipe, etc. Complete making good to floor as existing complete all as specified and directed by Engr-in-Charge.
S&Fin repair 15mm long body Bib tap cast copper fancy type chromium plated alloy with capstan handle screwed down screwed for iron pipe or for brass ferrule and fixed in repairs. complete all as specified and directed by Engineer-in-Charge.
S&F in repairs long body Pillar tap fancy type chromium plated with capstan head, screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipes 15 mm bore dia. Complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stop valve cast copper alloy chromium plated 15mm dia, screwed down, high pressure with capstan handle, screwed both ends for iron pipes or for unions and fixed with long shank and cup (concealed type) complete all as specified and directed by Engineer-in-Charge.
S&F in repair Angle valve cast copper chromium plated alloy15mm dia, screwed down, high pressure capstan handle, screwed both ends for iron pipes or for unions and fixed with long shank and cup complete all as specified and directed by Engineer-in-Charge.
Supply and fix, as in repairs, CP shower rose with arm 15mm size and 195mm long with bend of 45 degree with flange of any colour all as specified and directed.
Supply and fix Shower arm 15 mm size, 195mm long with bend of 45 degree with flange of PTMT any colour complete all as specified and directed
Supply and fix Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed
S & F in repair cast floor trap 100 mm dia with grating incl jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) with run lead complete all as specified and directed
M & L Salt-gauged stoneware gully traps, square or round mouthed, type 'P', size 150x150 mm complete all as specified and directed
S&F in repair of 2000 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical verticle with closed top) hoisted and fixed in position including suitable float valve fixed with GI pipe complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:6) on fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building)
M/L complete removal of old decorated surface by complete removal of existing treatment, washing, rubbing, stopping including old putty surface etc and applying two coat of oil emulsion distemper over a coat of alkali resistant primer and coat of wall / ceiling putty ( 2mm thick) to match with the new surface on wall and ceiling, complete all as specified and as directed by Engineer-in-charge (incl necessary scaffolding, upto 04 storey High of building).
(E/M PORTION) Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables, poles, stay and getting out of excavated material complete all as specified and directed by Engineer-in-Charge
Excavation in Trenches exc. for each additional 1.5m or part thereof in depth beyond the first 1.5 m for laying of steel tubular pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed by Engineer-in-Charge
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed.
M&L for sand cushioning as per para 19.75 of SSR Part-I(2009) in trenches for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and directed by engineer-in-charge. NOTE: Punned thickness only shall be measured for payment.
M&L for Brick protection with subclass ‘B’ bricks old size, laid dry, flat over cable perpendicular across the cable in trenches complete all as specified.
Laying Only Serviceable Bricks after cleaning by wire brush obtained from taking out unserviceable LT cable in connected items.
Taking out of interlocking paver block, any shape or size and Re-laying the same after removing all vegetation, algae, grass etc, laid to proper slope & gradient over sand cushioning complete all as specified and directed. (NOTE: Sand, if required for correction of cushioning level will be measured and paid separately. Replacement of broken paver block shall be paid separately as "Supply only")
Material and labour for machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS 15658-2006 of 60 mm thickness, M-35 grade complete all as specified and directed.
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 35 Sqmm, 3.5 core
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No 1 above) incl necessary aluminium thimbles, jointing and testing complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 35 Sqmm, 3.5 core
Supply, Laying, jointing and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary thimbles complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 Sqmm, 4 core
16 Sqmm, 4 core
25 Sqmm, 4 core
35 Sqmm, 3.5 core
M&L for replacement of Pole Mounted Junction Box 254 x 180 x 111mm, having insulated and made out of thermoplastic Polycarbonate with glass fibre reinforced, rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529, IK 07, weather proof for outdoor installation (with knockouts for cable entry) having Gasket Material shall be Polyurethane and the Gasket shall be internally embedded, Tested at 650°C, with Plastic Mounting Bracket, Din Rail, Mild Steel Flat Iron Clamp, Nuts, Bolts and Washers, with MCB SP 6 Amps, 'B' Curve, 10 KA, complete all as specified and as directed. MAKE: CAPE Electric Model No. TKPS 2518 - 11M or HENSAL cat Pt No. KF 2525B or equivalent make specified in tender.
S&F in replacement of PVC insulated multistranded copper conductor wire, 1.5 Sqmm 3 Core, round flexible for connection of light fittings, complete all as specified and as directed.
Material and labour for 15 mm thick rendering in cement mortar (1:4) on other than fair face of brick or concrete surface finished even and fair all as specified and directed.
S&F LED post top luminaire, 20-30 Watt, with die cast aluminium spigot, spun aluminium powder ,Heritage type coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver incl taking down existing luminaire complete all as specified an directed. (Make : SURYA, CAT NO: SLE PT 30W-HARY / CGL-LPTH-20-WW/ JAGUAR CAT NO-LGTP02X030XW or equivalent model in other makes specified in particular specifications) NOTE: Wire for connection of luminaire shall be measured and paid separately.
S&F LED flex strip light 5 watt , 45m to 50m length, IP 65, 5watt/metre, any colour including suitable driver and connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed. (MAKE : SURYA Cat No SPARKLE ROPE LIGHT/ PHILIPS CAT NO-MARATHON ULTRA YELLOW ROPE LIGHT/WIPRO CAT NO- GARNET 50 MTR LED STRIP LIGHT or equivalent model in other makes specified in tender)
S&F LED Rope light Tri colours in same length of (Orange+ White+ Green) of 6m length each. IP 65,), including suitable driver and connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed. (MAKE : SURYA Cat No SPARKLE ROPE LIGHT/ PHILIPS CAT NO- TRICO AC LED STRIP LHEHCIPIN6F135/ WIPRO CAT NO- GARNET 18 MTR TRICOLOUR LED STRIP LIGHT or equivalent model in other makes specified in tender)
S&F LED Up down wall light in die cast aluminium housing with high quality toughened glass cover IP 65,), including suitable connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed. (MAKE : SURYA Cat No SLE WL15W UP-DOWN / HAVELLS CAT NO-C LYCUS LED SPIKE LIGHT LYCUSSP S9W LED 730PSYMLIOWLS15WLED830PSYMTOTG/ JAGUAR CAT NO- 460LL9X2H.NHG or equivalent model in other makes specified in tender)
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1500mm x 1500mm x 500mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar 600 Amps of adequuate size for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron of size 50 x 50 x 6mm with legs not more than 600mm including fabrication with PCC 1:3:6 complete including earthing terminals complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories:- Make : Star Electric & Engg Co/ CPRI approved.
Taking down of serviceable LT Cable of different size from Building wall and fixing in cable tray complete all as specified and as directed.
Supply and fixing of Hot Dipped Galvanised(Z+) Wiremesh cable tray outdoor type with wire dia from 3.9 mm to 5.9 mm of size 3000mm x 105mm x 300mm, including supports. It shall be manufactured with a longitudinal 'T' welded safety edge. Trays shall be constructed with 50 mm / 100 mm mesh configuration. Accessories for coupling and making 'T's and bends CE25/CE30 screw based system combination must be used and mounting accessories are required of same finish of same manufacturer as per the site requirement (celing/wall mounted). Trays should comply standard EN ISO14 61: at least 550 hrs. of SST. The deflection of cable tray must be within 1/200-th of the distance between two supports and tested in accordance with the standard IEC 61537. Wire cable trays must be designed with an optimum span of 1.5 mtr., taking into account the maximum load carring capacity as authorised by the manufacturer. Assembly with fire ressitant properties must have an E30/E90 certificate. The loading capacities of the brackets and the hanger torques must be tested in accordance with the standard IEC 61537. No hot work for trays is allowed at site. MAKE: LEGRAND (CABLOFIL)/ COPE/ LEVITON/ PANDUIT
M&L for ERDN Coupler for jointing two cable trays with fixing arrangements KI TASTER complete all as specified and directed. Note : KI Taster will be measured and paid separetely.
M&L of KI Taster for jointing of two cable tray with the fixing arrangements complete all as specified and directed.
M&L of mounting support RCSN 3000 for cable tray compete all as specified and directed.
M&L of cable tray cover of 2 meter length joints with fixing clip complete all as specified and directed. Note : Clip will be measured and paid separetely.
M&L of Clip for joint of cable tray cover complete all as specified and directed.
Supply and fixing Cable tray of size 100 x 100 mm with all accessories complete all as specified and directed.
M&L for preparation of old painted surfaces of steel tubular poles above PCC coping including cross arms, brackets, pole box and applying one coat of aluminium paint including cleaning of wild vegetation growth/ trimming of tree branches in the vicinity, writing of poles number with sentensile measure white Paint in Black base on steel tubular pole and two black and two yellow strip upto 1.20 metre height with synthetic enamel paint complete all as specified and directed.
Demolition of broken/damaged PCC coping of steel tubular/PCC pole and removal of debris from site complete all as specified and directed.
Material and labour for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundations of poles, as mass concrete, complete all as specified and directed.
Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc complete all as specified and directed.
Materials and Labour for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (a) One light point or one fan point or bell point controlled by one switch or bell push
All as per item No 167 above but for one 5amp switch socket combination on independent board,complete all as specified and directed (surface type point wiring with terminal box)
All as per item No 167 above but for one 5amp switch socket combination on same board,complete all as specified and directed (surface type point wiring with terminal box)
All as per item No. 167 above but using 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 1.5 sqmm green FRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
One 3/5 pin socket outlet, 5 Amp independent
One 3/5 pin socket outlet, 5 Amp on the same board with other switches
All as per item No 171 above but using 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 171 above but using 4 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke ( FRLS ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm green copper conductor as continuous earth wire with lugs complete all as specified and directed.
S & F Modular Switch 1 way 6 A, 1 module complete all as specified and directed.
S & F Modular Switch 1 way 16 A, 1 module complete all as specified and directed.
S & F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed.
S & F Modular Bell push 6A, 1 module complete all as specified and directed.
S & F Modular Blank plate, 1 module complete all as specified and directed.
S & F Modular type White cover plate with frame 1 module complete all as specified and directed.
S & F Modular type White cover plate with frame 2 module complete all as specified and directed.
S & F Modular type White cover plate with frame 3 module complete all as specified and directed.
S & F Modular type White cover plate with frame 4 module complete all as specified and directed.
S & F Modular type White cover plate with frame 6 module complete all as specified and directed.
S & F Modular type White cover plate with frame 8 module complete all as specified and directed.
S & F Modular type White cover plate with frame 12 module complete all as specified and directed.
S & F Modular type Metal Flush box 1/2 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 8 module complete all as specified and directed.
S & F Modular type Metal Flush box 12 module complete all as specified and directed.
S & F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 5 Amp complete all as specified and directed.
S & F Switch socket combination 2 in 1, 5 Amp flush type complete all as specified and directed.
S & F Bell push, flush type, 5 amp complete all as specified and directed.
S & F Switch socket combination 5A/ 16A, 5 in 1flush type complete all as specified and directed.
S & F Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed.
S & F Bell , AC, 230 Volts, single pole complete all as specified and directed.
S & F Musical Call Bell complete all as specified and directed.
S & F stepped type electronic fan regulator flush type complete all as specified and directed.
S & F Ceiling rose, 3 terminal PVC insulated body complete all as specified and directed.
Taking down Repair/ Re fixing LED lights fitting any type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifide and directed.
Supply and fixing LED lights fitting 1x 20W, 220V,W/NW light AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifide and directed.
Supply and Fix in repairs recess mounted LED luminaire suitable for 600 x 600 snap grid ceiling with constant current driver with in built protection against lightning, over voltage & short circuit complete with all accessories with and including 36 Watt LED 6000K (having minmum efficacy of 110 lumen/watt) and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor cable of size 1.5 sqmm (nominal area) complete all as specified and directed.
Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation.
M & L for sub main wiring with 4 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed.
All as per Srl. Item No.211 above but with 2 run of 6.0 Sqmm cable and 6.0 Sqmm as earth continuity conductor.
All as per Srl. Item No. 211 above but with 2 run of 4.0 Sqmm cable and 4.0 Sqmm as earth continuity conductor.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunsheds, shelves, lintel etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting n exc 10 cm girth on brick wall all as directed
Taking down of Old MCB DB any type any size including MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site.
S & F TP&N Vertical Loadline Dbs are fitted with Bus Bars, Neutral Links, Blanking Plates 4 way double door DB LL 4W DD VERT W/O MCCB complete all as specified and directed.
S & F MCCBs 415V, 16KA, 4 Pole 100Amps. complete all as specified and directed.
S & F MCB 'C' curve single pole neutral , 32 Amps with breaking capacity 10kA complete all as specified and directed.
S & F Double door sheet metal enclosure for DBs(Normal range) for mounting of MCB for 240 Volts 8 Way with 100 Amps rated copper bus bar,single pole and Neutral complete all as specified and directed.
S&F GI in repair tubing medium grade of size 15 mm dia incl painting and making hole for extention of fan hook in high roof ceiling complete all as specified.
S & F in repair clamp with buckle for hanging ceiling fan including nut and bolts complete set all as specified and directed.
Supply only MCB, 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
S & F in repair AC short circuit protection motor starter 25 Amps capacity AC 230 Volt complete all as specified and directed.
S & F in repair lamp pendant / batten holder, complete all as specified and directed .
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
Supply, Laying and testing for replacement of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall with saddles/Flat iron clamps as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area (a) 50 Sqmm, 3.5 Core
Hanging and fixing Ceiling fan of size1200/1400 mm sweep all connecting the electric supply with ceilitig rose or connector to fan including of connection flexible wire length complete all as specified and directed by Engineer-In-Charge. (Ceiling fan will be issued under Sch 'B' free for fixing.)
Supply, install, commissioning and testing of feeder Pillar Box mounting on PCC base cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1300mm x 1300mm x 600mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Aluminium bus bar 800 Amps of size 50mm x 6mm (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron frame with base 40 x 40 x 5 mm with legs not more than 300mm long including grouting with PCC (1:2:4) complete including earthing all as directed by the Engr-in-Charge including supply and fixing of the following accessories:-
INCOMING (a)Supply and fixing of 4P 630A 36kA Thermal Magnetic MCCB along with spreader with neutral protection built-in,having Ui (Rated insulation voltage)=800V, Uimp(Rated impulse withstand voltage) =8kV peak, Rated Operational Voltage = 690V, Ics=Icu=100%, There should be no current deration up to 50-degree C. - 01 Nos Make: Legrand Cat No. – 667665/Schnider/Siemens OUTGOING (a) MCCB design with thermal-magnetic releases of capacity 320 Amps, 4 Pole, 36 KA - 01 Nos (Outgoing). Make : Legrand/Schnider/Siemens (b) MCCB dsign with thermal-magnetic releases of capacity 200 Amps, 4 Pole, 25 KA - 01 Nos (Outgoing). Make Legrand/Schnider/Siemens (c) MCCB dsign with thermal-magnetic releases of capacity 100 Amps, 4 Pole 25 KA - 02 Nos (Outgoing). Make : Legrand/ Schnider/ Siemens
Supply and fix ceiling fans, complete with three blade,down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor. flexible wire with multi stranded copper conductor of size 0.50 sqmm , 3 core, 1100 Volts grade, from ceiling rose / connector to fan complete all as specified and directed.
S & F Wall mounted fan 450 mm sweep, 2100 RPM , AC single Phase 230 / 240 volts, metal body with louver shutters and connecting up with and including twin core twisted flexible copper conductor cable of suitable dia ,nut bolt and accessories,BEE 5 Star Rated and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm , 3 core, 1100 Volts grade, from ceiling rose / connector to fan complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4.0mm GI wire (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 5 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering all as specified and directed and tested on completion.
S&F switch piano flush button type 5 Amp single pole one way complete all as specified and directed.
S&F Switch and socket combination 6 pin 15 Amp AC 230 Volts piano flush button type (multipurpose) complete all as specified and directed
S&F Ceiling rose three terminals polycarbonate , isolated body complete all as specified and directed.
S & F in repair Recess mounting LED 12 Watt Slim round down lighter made of Green Perform sleek is a high ferformance low-height LEDmodern professional workspace. Robust PDC housing ensures long system complete all as specified and directed. Make Philips Cat - DN295B LED10S-6500 PSU WH or equivalent make specified in tender.
S & F in repair LED tube light fitting 10 watt, mirror type /mounted on wall / ceiling connected with insulated unsheathed flexible copper wire of suitable size (length not exceeding 0.5 m) from ceiling rose complete all as specified and directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix exhaust fan heavy duty AC single Phase 230 V / 240V 50 Hz of size 300 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
M/S SRINIVASA CONSTRUCTION (BID ID -3437966)
MODERN AGENCY (BID ID -3439089)
HYDROTEC (BID ID -3438734)
SK CONSTRUCTION SYNDICATE & ENGG CO (BID ID -3437983)
DGR CONSTRUCTION (BID ID -3437860)
Piu Projects (BID ID -3440605)
M/S L.R.ENTERPRISES (BID ID -3436937)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
pdfjoiner8482.pdf
Tender Documents • 1.84 MB
BOQ_817920.xls
BOQ • 0.70 MB
Download all tender documents and submit your bid