| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC PHYANG | L1 | Accepted-AOC Found lowest one bidder | |
| 2 | L2₹5.3 L+₹33,760 (6.75%)Rejected-AOC | L2 | Rejected-AOC Quoted high rate as compared to L1 |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
1 Oct 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Rural Engineering Wing Leh
Construction of Library at Govt.Middle School at Tashi Thongsmon Choglamsar
2021_RDD_4577_1
NIT 82 UTLeh REW of 2021-22
Open Tender
Civil Works - Others
Item Rate
60 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
Executive Engineer
₹14,000
Yes
10 Nov 2021
22 Sept 2021
5 Oct 2021
22 Sept 2021
1 Oct 2021
22 Sept 2021
120 days
Amount
Wiring for light point fan /exhauaust fan/ call bell point /6amp socket with 1.5sqm PVC.FR insulated copper conductor single core in surface /recessed medium class PVC conduct suitable size m.s box and earthing the point with 0.75 sqm FR PVC insulated copper conductor single core cable required .
wiring for 16 Amp socket outlet with 2.5mm FR PVC insulated copper conductor cable in existing recesses PVC conduct including sheet as required
supplying and drawing circuit wire for light and 6/16 amp socket outlet with 4.0sqm FR PVC insulated copper conductor single core cable in recessed /surface PVC conduct pipe as required
supply and fixing of 25mm PVC conduit capping along with accessories in surface recessed including cutting the wall and manly good the same in case of recessed conduct as required .
supply and fixing 10amp 240 volt single pole grid plate mounted switch indicator with molded copper plate including recessed conduct as required
Supply and fixing of combined 3 pin 240 volt 10amp socket outlet with safety shutter and 10amp 240 volt single pole mounted in recessed including M.S box complete as required.
Supply and fixing of combined 3 pin 240 volt 20amp socket outlet with safety shutter and 20amp 240 volt single pole mounted in recessed including M.S box complete as requird
Supply and fixing of following single pole and neutral sheet steel MCB distribution board 240 volt on surface recess complete with tinned busbar neutral link earth bar, tin bar, detachable glaud plates, double door interconnected including pointing etc as required 16 way double door SPN.
Supply and fixing of the following light fixtures including all accessories like electronic ballasts coms etc, complete as required concealed/Tube lightning 20 watt 3000k, round LED Luminaries as per Philips
Supply of 1100 volt grade aluminium conductor KPLE insulated PVC sheath arranged complete as per specification as required 25 sqmm, 3.5 core
Clamping and fixing of one numbers PVC insulated and PVC sheathered of size including connecting etc as required exceeding 25sqmm but not exceeding 120sqmm.
Wiring for changeover 63 amp and installtion with complete accessories and holes on the wall as required.
Wiring for telephone outlets with 2 pair 0.5sqmm PVC insulated copper telephone wire in the existing surface recessed conduit ad required.
Supply and fixing of single telephone cord socket outlet with back lite sheet in recessed box complete as required
Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing and commissioning etc, as required.A) Single pole 6/10/20 Amp
Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing and commissioning etc, as required.B) Double pole 40 Amp
Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing and commissioning etc, as required.C) Double pole 63 Amp
Supply and fixing of TV cable R-G6 wire with cord and switch (TV/Switch) in recessed box , complete as required.
Junction box 3 inches 250 grams G.I with holes for connection, submersed in concrete with connections as required.
Fan box with rod 500 grams G.I with holes for connection, submersed in concrete with connections as required.
Providing and fixing ceiling fan of approved brand philips, crompton,havels etc. complete jobs
3 modular plate
6 modular plate
12 modular plate
Exhaust fan 150 mm
ceiling fan regulator
supply and installation of electric connector heater heavy waltage (2000w or 2606w) app size 1200 x450x90mm with over heat protection thermostatically controlled detachable wall mounting (digital LED display digital room temperature sensor etc with ISI marked under the direction of engineer in charge
THINLES ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .