Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC 67 MANNUGANJ HAKIKAT RAI NAGAR DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹28.0 L+₹3.5 L (14.2%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹28.6 L+₹4.1 L (16.6%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹29.0 L+₹4.5 L (18.4%)Rejected-AOC SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 5 | L5₹29.1 L+₹4.6 L (19.0%)Rejected-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹38.1 L
EMD Value
₹76,300
Closing Date
24 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
ADDITION/ALTERATION OF BLDG NO. P- 6 (OFFICER MESS) AT CQA(I)RAIPUR ROAD UNDER GE (I) RND DEHRADUN
2023_MES_634753_1
GE(I)RND/9317/E8/23-24
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Class D Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹76,300
Yes
13 Feb 2024
28 Dec 2023
26 Jan 2024
28 Dec 2023
24 Jan 2024
10 Jan 2024
28 Dec 2023 - 10 Jan 2024
Amount
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar 1:4 with brick/concrete surfaces, finished even and smooth without using extra cement.of internal wall complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as supply only under respective item of sch A/BOQ.
M & L rendering 5 mm thick on brick or concrete surface in cement mortar 1:3 on ceilling surface finished fair and even smooth finished complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and recast concrete articles complete all as specified and directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) with old size bricks complete all as specified and directed.
M&L Plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate as in foundation filling & Mass concrete , sub base.complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description in any position not otherwise specifically provided for and removing demolished materials to a distance exceeding 250 Mtr complete all as specified and directed.
M&L RCC (1:2:4)Type B1 using 20mm graded stone aggregate for Beams, cantilevers, bressummers, lintels over 1.5m span etc. with and including use and waste form work for fair finished surfaces complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
M & L for applying two coats of Distemper oil emulsion, white or tinted on new ceiling surface over a coat of 3 mm thick wall care putty including preparation of surface complete all as specified and directed.
M & L for applying two coats of Distemper oil emulsion, white or tinted on old ceiling surface after complete removal of existing treatment over a coat of pirmer over coat of 3 mm thick wall care putty including preparation of surface complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over 3 mm in two coat of water proof wall care putty including preparation of newaly plastred external surfaces of wall complete all as specified and directed.
Material & Labour for complete removel of existing treatment of old plastred external surfaces of wall and prepration of scraped surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over 3 mm in two coat of water proof wall care putty including complete all as specified and directed.
M&L for preparing of new plastered surface on wall and applying two coats of Oil bond distemper over a coat of alkali resitance primer over 3 mm thick wall care putty in two layer on plastered surface complete all as specified and directed.
M&L for complete removel of existing treatment of old plastred surfaces of wall and prepration of of scraped surfaces on wall and applying two coats of Oil bond distemper over a coat of alkali resitance primer over 3 mm thick wall care putty in two layer on plastered surface complete all as specified and directed.
M&L for hard core, broken stone boulders to gauge n exc 63 for sub base complete all as specified and directed.
M&L Plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate as in foundation filling & Mass concrete , sub base.complete all as specified and directed.
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) Double charge polished, area of each tiles exc. 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed or bedding layer in cm (1:6) complete all as specified and directed complete all as specified and directed.
M & L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.60mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.60mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Fibre glass reinforced translucent corrugated sheeting, 2 mm thick with two corrugation side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
M&L for Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Dismantling floor, hearth or wall tiling/stone including cement mortar bedding (but not backing) or of any description , removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Virified Ceramic tiles 10 mm thick dark shade double charged/ultracharged (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry @3.3 kg/per sqm and pointed inwhite or colour cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
Ditto item No. 26 above but on vertical surface such as dado, skirting etc set and jointed in neat cement slurry @3.3 kg/per sqm and pointed in white or colour cement to match including 10 mm thick screed bed or bedding layer in cm (1:4) complete all as specified and directed complete all as specified and directed
M&L non skid coloured ceremic tiles 7 to 8 mm thick (square/rectangular) area of each tilles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. Set & jointed in neat cement slurry @3.3 kg/per sqm and pointed in colored cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in cm (1:6) complete all as specified and directed
Ditto item No. 28 above but on vertical surface such as dado, skirting etc set and jointed in neat cement slurry @3.3 kg/per sqm and pointed in white or colour cement to match including 10 mm thick screed bed or bedding layer in cm (1:4) complete all as specified and directed complete all as specified and directed
M&L Glazed ceremic tiles in vertical surface 350x250x7 mm /450x350x7 mm thick set & jointed in neat cement slurry @3.3 kg/per sqm and pointed in colored cement to match coloured tiles laid over and including 10 mm thick Plastering in cm (1:4) complete all as specified and directed.
Dismantling of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid, bedded & pointed in any mortar complete all as specified and directed.
M & L for 18 to 20mm thick Granite stone slab (of any type/Colour ) Slabs machine cut in skirting/dado and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing over 15mm thick cement mortar 1:4 , on fair faces of brick work or concrete surfaces as backing for Granite stone slab complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 18-20mm thick over 20 mm th cement screed in CM 1:3 base laid and jointed with grey cement slurry @3.3 kg/per sqm mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&l for tinted toughened and tampered galss panes including unframed assembiles (such as frameless door) comprising of 12 mm thick glass pressed by controlled themal of chemical treatments to increase its strength compared with normal glass conforming to IS 2553 prt-I to be fitted as per manufactures instructions complete all as specified and as directed. Note : (1) No cutting and grinding of glass shall be allowd at site of work and the contractor shall procure actual size required at site in construction with Engineer-in-Charge prior to placing order for the same. (2) Rate is inclusive of all fittings such as suitable heavy duty hyralic floor spring, locking arrangement with cover plates, stainless steel 600 mm fancy type handle 02 nos on each shutter and ixtures as stainless steel cleats required at site. (3) The work shall be got executed by the specialist agency as approved by GE. (4) Existing door opening shall be finished identical to existing one like finishes including holes cut and any other damage to jambs & lintel of wall for taking out hold fast etc.
M&L for 10 mm thick toughend glass partition of any size as site required including polishing round edges frosted type fixed with SS frame/clips/ wall by embedding inside etc complete all as specified and directed.
Taking down Chowkats or frame with shutter ( without taking off shutters from the frame) exc. 1.5 sqm but exc 4.0 sqm each complete all as specified and directed.
S&F Ist class HW plain, solid, straight chowkates and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows or partition including aluminium beading, hinges of required size,jointing cleats, screws, dash,fastners,plug for fixing with wall, columns etc complete all as specified and directed.
S&F powder coated of any colour aluminium door shutters, aluminium section like lock rail, bottom rail 115mmX38mmX0..55mm thick and top rail and vertical rail 100mmX38mmX0.55mm thick mm including necessary jointing cleats/glazing clipx, rubber neorene paking, handles 02 Nos in each door, locking arrangment, aluminium snap beading screw etc, complete all as specified and directed. (panels likes prelaminated particle board / sheet glass shall be measured and paid seprately)
M&L for 4.80 mm thick sheet glass ordinary quality in panes exc 0.50 sqm each fixed with & including rubber gasket in aluminium frame work complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm Nominal dia and average width of aperature 1.4 mm and fixed with stainless steel wire staples in repair complete all as specified and directed.
S&F 40 mm thick Flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed.
Dismantling wall and ceiling boards (fibre pulp, insulation, etc) or insulation board/slabs/blankets any thickness including grid work/aluminium frame work, cover fillets complete all as specified and directed.
M&L for PVC SHEET WALL PANELLING of thickness 5mm solid consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm thick prelam PVC sheet. The panel & strips shall be of 600 kg / cbm density manufactured by an ISO-9000 certified company. The strips should two PVC strips. The PVC strip shall be fixed to the wall using 65mm long M.S screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a U Channel at top, bottom and side edges and strips of 5mm thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement complete all as specified and directed ( Note- Including all nesscesary fittings and scafolding for heighted site) complete all as specified and directed.
M & L Gl frame work for seamless ceiling comprising of Gl perimeter channnel .55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to tre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre incl Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M & L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter grey colour with particle board core 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, in opening complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt 250mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F Floor door stopper double leg of 140 mm overall length aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F 100 mm long mild steel butt hinges, medium weight cold rolled including welding if required complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F 125 mm size aluminium handles,cast type anodized D type complete all as specified and directed.
Taking down Cast iron/PVC pipe of any dia and size fixed on wall or floor including all fittings complete all as specified and directed.
S&F 110 mm dia PVC (SWR) Rain water, pipes fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends/shoes, 110 mm bore dia fitted with access door complete all as specified and directed.
S&F PVC (SWR) Tee reducer 150/100/75 mm complete all as specified and directed.
S&F PVC (SWR), junction single, (Single T) equal or unequal 110mm dia fitted with access door complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for re fixing complete all as specifed and directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for re fixing complete all as specifed and directed.
Taking up or down 25 or 32 mm bore steel tubing and connections, including cleaning for re fixing complete all as specifed and directed.
Cutting chases, pinning in, making good to facings where required and pointing in CM(1:3) to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in brick wall complete all as specified and directed.
S&F, laying and testing for 15 mm bore GI tubing medium grade galvanised steel tubing including all fittings such as union, reducer, sockets, reducing bends elbows tee, checknuts, caps, plugs etc fixed to wall and ceilling or laid in floors complete all as specifed and directed.
S&F, laying and testing 20 mm bore GI tubing medium grade galvanised steel including all fittings such as union, reducer, sockets, reducing bends elbows tee, checknuts, caps, plugs etc fixed to wall and ceilling or laid in floors complete all as specified and directed.
S&F, laying and testing 25 mm bore GI tubing medium grade galvanised steel tubing including all fittings such as union, reducer, sockets, reducing bends elbows tee, checknuts, caps, plugs etc fixed to wall and ceilling or laid in floors complete all as specifed and directed.
M&L for S & F WC ET - Cat Part No-4256, Make: Prayag or equivalent in Parryware/Hindware/Jaquar as approved by GE. with integrated cistern, seat cover and twin flush system White colour , complete incl seat cover , fixing bolts etc. complete all as specified and directed.
S&F in repair vitreous china sqatting pan (orissa pattern) size 580mmx440mm, white with integral foot rest, any pattern including provision of cement concrete bedding (excluding fulshing cistern and flush pipe) with S or P trap, Fixed in repairs, complete all as specified and directed.
S&F in repairs low level Flushing cistern 10 ltr capacity, PVC valveless syphonic action type, white with inlet, ball valve, float valve and handle , flush pipe, incl brackets and flushing pipe fixed in repairs complete all as specified and directed.
S&F in repair 20 mm bore gun metal gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 25 mm bore gun metal gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm size PVC connections internally threaded with PVC washer,PTMT nuts of length 450mm complete all as specified and directed.
S&F Grating 100 mm dia of CP with or without hole complete all as specified and directed.
S&F in repair 15 mm dia bib tap cast copper alloy (fency type), chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair wash hand basin,White, Pedestal type including brackets, PVC connection waste pipe waste coupling etc complete all as specified and directed. Make: Prayag Cat Part No-4603, or equivalent in Parryware/Hindware/Jaquar. as approved by GE.
S&F in repair Urinal pot, White, fixed with and including all necessary CP brass screws, waste coupling etc complete all as specified and directed. Cat Part No-4998, Make: Prayag or equivalent in Parryware/Hindware/Jaquar.
S&F 15 mm dia concealed angle stop cock fancy type chromium plated with long shank and cup complete all as specified and directed. Make : Jaquar or equivalent in Parryware/Hindware as approved by GE.
S&F in repair 2 Way Bib tap, cast copper alloy fancy type suitable for 15 mm dia pipes complete all as specified and directed. Make : Jaquar or equivalent in Parryware/Hindware as approved by GE.
S & F in repairs fancy type chromium plated health faucet with 1.2 Mtr long PVC tube cover CP flexible with wall hook, suitable for 15 mm bore pipe or for union and fixed complete all as specified and directed. Make :Prayag cat No: BEA 101 or equivalent in Parryware/Hindware as approved by GE.
M&L for S & F S S Jet sprey (Butterfly) Make: Cat Part No-BEA-17, Prayag or equivalent in Parryware/Hindware/Jaquar as approved by GE. with Braided tube 105 m long, complete all as specified and directed.
S&F in repair, M&L for S & F Towel Ring, Cat Part No-BA-21, Make: Prayag or equivalent in Jaquar/ Parryware/Hindware as approved by GE, complete all as specifed and directed.
S & F Corner Glass Shelf fixed with CP brass screws complete all as specified and directed. Make: Prayag Cat Part No-BEA-52, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
S & F in repair liquid Soap Dispenser Holder fixed with CP brass screws complete all as specified and directed. Make : Prayag Cat Part No-BA-83, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
S & F in repair Soap Dish fixed with CP brass screws complete all as specified and directed. Make : Prayag Cat Part No- BA-85, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
S & F in repair CP brass Urinal Spreader fixed with CP brass screws complete all as specified and directed. Make : Prayag Cat Part No- BEA-25, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
S & F CP brass Toilet paper holder fixed with CP brass screws complete all as specified and directed. Make : Prayag Cat Part No- BA-08, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
S & F CP brass Towel Rack fixed with CP brass screws complete all as specified and directed. Make : Prayag Cat Part No- BA-12, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
M&L for S & F Bib cocks, chriomium plated brass, long nose with flange,15 mm fancy type complete all as specified and directed. Make : Prayag Cat Part No- PIS 09 H, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
S & F for central hole basin mixer,15 mm fancy type complete all as specified and directed. Make : Prayag Cat Part No-6350N, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
S & F in repair Wall Mixer 3 in 1 (with provision of over head shower and hand shower both) Cat Part No-7880-N, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
M&L for S&F Chromium plated brass Angle cock with flange complete screwd down for 15 mm GI bore pipe complete all as specifed and directed. Make : Prayag Cat Part No-PIS 10 H, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
S&F chromium plated brass 2 Way Angle cock with flange complete screwd down for 15 mm GI bore pipe complete all as specifed and directed. Make: Prayag Cat Part No-8510 or equivalent in Parryware/Hindware/Jaquar as approved by GE.
S&F chromium plated brass Bottle trap, 12'' complete all as specifed and directed. Make : Prayag Cat Part No- BEA-27, or equivalent in Parryware/Hindware/Jaquar as approved by GE.
S&F Connection Tube, 600 mm long with brass nut and spenner complete screwd down for 15 mm GI bore pipe complete all as specifed and directed. Make : Prayag Cat Part No- BCT 045, or equivalent in Parryware/Hindware/ Jaquar as approved by GE.
S & F bathroom Cabinet and With mirror complete all as specified and directed. Make : Prayag Cat Part No-555, or equivalent in Parryware/Hindware/ Jaquar as approved by GE.
S&F 300 mm Brass sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts complete all as specified and directed.
S&F 200 mm long brass barrel tower bolts, with barrel of extruted section complete all as specified and directed.
S&F 150 mm extruded brass handles fabricated type polished complete all as specified and directed.
S&F 125 mm long hasp & staple safety type aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed
S&F in repair 125 mm size Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specifed and directed.
S&F in repair aluminium die cast body door closer hydrau lically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete all as specified and directed.
S&F in repairs Stop valves 15 mm bore, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in 18 to 19 m thick solid factory made PVC board board for cup board/cabinate shutters with one or both side laminated printed PVC celluka board ,anti termite and anti moisture proof etc sheet fixed with & including suitable PVC frame and Magnetic door catcher as per specification & drawing complete all as specified and directed.
S&F 25 m dia brass knobs for cupboard fixed with nut and screw and washer of mild steel, bright finished complete all as specified and directed.
S&F continous (piono) hinges mild steel, bright finish or electrogalvanised with width of flap (when open) 20 mm complete all as specified and directed.
S&F 125 mm long hasp & staple safety type aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed
M&L for taking out old drapery rod and S&F vertical window blinds made up with vertical louvers, manually operated, with dust guard features, operated by wand control system, of shade and design as approved by the Engr-in-Charge incuuding necessary fittings complete all as specified and directed.
S&F in repair Harrison rails 20 mm dia ,anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc complete all as specifed and directed .
Disconnecting & taking down existing water tank of capacity exc 500 liter and not exc. 1000 liter and removing from site complte and S&F rotational moulded polyethylene water storage tanks 1000 lts capacity (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed.
Roughening surfaces of old concrete floor/terrace by picking incl. taking down existing detoriated / decayed tar felt or any treatment including loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials debris to a distance not exc. 1000 m. complete all as specified and directed.
M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with liquid water proofing compound @ 0.2 ltr per beg of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as supply only under respective item of sch A/BOQ.
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for Non approachable roofs-
Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster complete all as specified and directed.
One layer of APP based polymeric membrance minimum weighing 3 Kg/ Sqm & minimum 3 mm thickness reinforced with polyster non woven fabric (wt not less than 150 gms/ sqm) land on primed surface by forced application ccomplete all as specified and directed with lap of 100 mm and the over lap shall be sealed by flame
Applying two coats of aluminum paint on top of membrane @ 0.10Kg/Sqm. NOTE:- The work of water proofing treatment shall be got executed throughh expert team of manufacturers or authorised applicator of manufacturer complete all as specified and directed.
M&L cement concrete in roof kerbs, mud stops or coving (rounded or chamfered on edges as directed) type B1 (1:2:4) using 20 mm graded aggregate complete all as specified and directed.
M&L French polishing on surfaces of any description, over 10 cm width or girth including cleaning & preparing the surface including a coat of wood filler on old works with one or more coats complete all as specified and directed.
M&L for Preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron. complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment Of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same All as specifed and directed.
Taking down of carefully unserviceable Aluminium/copper point wiring(light, fan, socket or power) complete with fitting such as switches, ceiling rose, lamp holder, sockets, fan regulators, SK/FTL light fiitngs etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with Gl saddles, Gl screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch.
All as per Srl item No 124 above for point wiring for one light point controlled by two Nos two way switch complete all as specified and directed.
All as per Srl item No 124 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed
All as per item No 124 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Make of cable and conduit: Havells/Plaza/Klinga
All as per item No 2 above for one power point 3 pin 15 Amp socket outlet PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly,complete all as specified and directed for one 3 pin 15 amps socket outlet point controlled by one switch.
Note for item 124 to128 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick/walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams!Ceiiings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs . (n) Rate for modular metal flush boxes ,inner and outer plate with frames are deemed to be included in the quoted rate by contractor for above items. (iii) Fittings like Modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule (iv) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade (v) Make of PVC conduit & fittings : Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE.
S & F Modular switch piano single pole one way 6 amp complete all as specified and directed. Make -Legrand/Anchor Penta/Havells as approved.
S & F Modular switch piano single pole one way 16 amp complete all as specified and directed. Make -Legrand/Anchor Penta/Havells as approved.
S & F Modular switch 6 amp single pole 2 way complete all as specified and directed. Make -Legrand/Anchor Penta/Havells as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete all as specified and directed. Make Legrand / Anchor Penta / Havells as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete all as specified and directed. Make Legrand / Anchor Penta / Havells as approved.
S&F ceiling rose 3 plates made of polycarbonate, isolated body complete all as specified and directed. Make Legrand / Anchor Penta / Havells as approved.
S&F modular fan regulator step type, suitable for ceiling fans, prewired 230 Volts AC 50 Hz 120 Watt 2 module complete all as specified and directed Make Legrand / Anchor Penta / Havells as approved.
S&F Angle holder, insulated polycabonate body with back plate suitable for batten each fittings suitable for One number LED lamp 9/10 Watt. Make Legrand / Anchor Penta / Havells as approved.
S&F in replacement of Single pole and neutral enclosure with a two pin and earth plug Each and socket complete with one single pole and neutral MCB 20 amp,240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet. Make of SPN DB with MCB 20Amp - L&T/Legrand/Schneider as approved.
Supply & fix LED tube light along with fixture, Ix18 W including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as directed. Make: Havells/Crompton/Bajaj/Wipro
Supply & fix LED luminaire round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed Make: Havells/Crompton/Bajaj/Wipro
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.Make: Havells/Crompton/Bajaj/Wipro
S&F LED Bulb 9 Watt B-22 Base type suitable for mounting in wall mounting Decorative fittings and batten holders as mentioned in Item No and above. Make : Havells cat Pt No. LHLDEUEEML8R009 or equivalent in Crompton/ Bajaj/Wipro
Supply, fixing, connecting and testing LED street light fitting 35 watt , single piece (pressure die cast aluminium housing) with Pot optics reflector & polycarbonate cover (IP-66) complete with and including all accessories to be fixed on pole, including with connecting the fitting to bus bar (Terminal box) at the bottom of pole with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor cable complete all as specified and directed. (Make : Bajaj/ Crompton / Havells)
Disconnecting and taking down ceiling fan from any location and removing fan & blade depositing to MES store.
Supply and fixing LED post top lantern with symmetrical light distribution, with LED light source 20W, 5700K complete all as specified and directed
Supply and fix exhaust fan heavy duty, steel body AC single Phase. 230V of size 450m sweep with, blades, and frame and louvers complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
Supply and fix ceiling fans complete with blades, down rods and accessories AC single Phase. 230V , 1200 mm sweep, five star rating with squirrel case induction motor complete all as specified and directed.
Disconnecting and removing ceiling fan of 1200/1400 mm sweep any height from Job electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and writing MES No with black paint and testing complete all as specified and directed.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. Notes for item No. : (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars ete for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1 :4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : KEI /Havells/ Polycab as approved by GE. (iv) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National !KaIinga es approved by GE. )
M&L in replacement UNSV of sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed.
Notes for Item No 151 & 152 here in above : (i) Four run of single core PVC cable with two run of earth conductor and one run of conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1 :4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) KEI /Havells/ Polycab as aproved by GE . iv nake of PVC conduit & fittin s : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. )
S&F in replacement of UNSV vertical type load line distribution board TPN 4 way with Each 200 Amp rated copper bus bar made of sheet steel enclosure (housing), double door recessed type factory made duly painted 4 way suitable for mounting one incommer, 4 pole, 415 volts isolator/RCCB/MCB and outgoing TP/SP 5/20 Nos respectiviely outgoing MCB's complete as directed. MCB's/ isolator complete including colour coated bus bar, Neutral link, Earth bar and Din Rail complete with all fixing materials/accessories such as mounting bracket, fixing clamps, etc complete all as specified and directed. (i) MCCB/MCB's [Isolators etc. shall be measured and paid for separately under appropriate item of Sch 'A. ' Make: Legrand Cat Pt No. 4025 07 or equivalent in Havells/L&T/Schneider/ IndoAsian as approved
S&F in replacement of UNSV MCB distribution board SPN, 240 volts, 8 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB's /lsolators etc. shall be measured and paid for separately under appropriate item of Sch 'A'. Make: Legrand Cat Pt No. 4025 07 or equivalent in Havells/L&T/Schneider/ IndoAsian as approved
Supplying and fixing MCCB four pole of 160 Amps, 415 volts, 50 Hz, AC made from adjustable thermel setting & fixed magnetic setting , 36 KA breaking capacity complete at existing Main LT Panel for Officer Mess near transformer, complete all as specified and directed.
33 Supplying and fixing MCCB four pole of 63 Amps, 415 volts, 50 Hz, AC made from adjustable thermal setting & fixed magnetic setting , 16 KA breaking capacity complete, existing Main LT Panel for Security light 'C' Block near transformer complete all as specified and directed.
Supply and fixing MCB TPN, 415V,1O KA 'C' curve miniature circuit breaker three poles and neutral current carrying capacity 40 to 100 Amp in the DB complete with connection testing and commissioning complete all as specified and directed.
S&F MCB Single pole & neutral 20/25/32 Amps, 230 volts, 50 HZ, 'C' curve complete all as specified and directed.
S&F MCB Single pole 6/10/16/20/25/32 Amps, 230 volts, 50 HZ, 'C curve complete all MCB, single pole 6 complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 3 of 1991 (Part-I) including taking out old existing earthing complete all as specified & directed.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised strip 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 3 of 1991 (Part-I) including taking out old existing earthing complete all as specified & directed.
Supply and install hi wall split units 2 TR indoor/outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement, PM 2.5 air filter, anti viral dust filter complete with all accessories including voltage stabiliser of 5 KVA complete all as specified and directed.
M/S P K ARORA
JS CONSTRUCTION COMPANY
OM TRADERS
M/S WASEEM KHAN CONTRACTOR
ANEJA AND COMPANY
M/S PUNDIR BUILDERS
Gaur Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .