Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹35.8 L+₹1.4 L (3.98%)Rejected-Finance PLOT NO 39 SHRI SHIVE NAGAR 05 MOTI BANDHA MACHEDA HARMADA JAIPUR 302013 RAJ | JAIPUR | JAIPUR | RAJASTHAN | 302013 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹40.0 L+₹5.5 L (15.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹37.8 L+₹3.3 L (9.70%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹39.8 L+₹5.3 L (15.3%)Rejected-Finance PLOT NO L 7 KRISHNA KRIPA VILLAGE SIROLI JAGATPURA JAIPUR 303905 RAJASTHAN | JAIPUR | JAIPUR | RAJASTHAN | 303905 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
30 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
CERTAIN REPAIR/MAINT OF BUILDING AND PERIODICAL SERVICES (INTERNAL/EXTERNAL SURFACES) OF BUILDINGS AT UDHAM VIHAR MD ACCNS UNDER GE (S) JAIPUR AT JAIPUR MIL STN
2025_MES_702969_1
GE(S)/J-66P/2024-25 8978/E8
Open Tender
Civil Works
Item Rate
270 days
GE(S) Jaipur
Class D and category a(i)
8 documents required · 8 mandatory
₹500
GE(S) Jaipur
₹96,000
Yes
25 Jun 2025
28 Mar 2025
7 May 2025
28 Mar 2025
30 Apr 2025
16 Apr 2025
Amount
M&L for complete removal of existing treatment and preparation of old surface of wall of any description and surface to be repaired by filling putty in holes / depression if required and applying two coats of cement based paint over a coat of primer complete all as specified and directed. Note :- Cement base paint shall be carried out as specified in clause 15.15 of SSR Part-I including all necessary arrangement such as scaffolding/working plateform for execution of work upto four storey building etc.
M&L for preparing of old decorated surfaces of wall (Plastered or unplastered) including cornices plaster and other wall features by washing, rubbing down and stopping of distmpered, surface to be repaired by filling putty in holes & depression if required to obtain even and uniform surface etc and applying One coat of oil bound distemper on wall white or tinted including scaffolding arrangement, trestles, ladders etc for execution of work upto four storey .
M&L for complete removal of existing surface of ceiling (Plastered or unplastered) by washing, rubbing down and stopping of distmpered and surface to be repaired by filling putty in holes & depression if required to obtain even and uniform surface etc and applying Two coat of oil bound distemper on ceiling white or tinted including scaffolding arrangement, trestles, ladders etc for execution of work upto four storey .
M&L for preparation of old plastered surfaces of ceilings and apply one coat of white wash on old decorated surfaces complete all as specified and directed.
M&L for Stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore of pipe complete all as pecified and directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and surface to be repaired even & smooth by filling putty in holes & depression if required to obtain even and uniform surface etc and applying two coats of oil bound distemper on wall of approved tint complete including all necessary arrangement such as scafflolding / working platform for execution of work upto four storey complete all as specified.
M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted surfaces of steel of any description, over 10cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
Dismantling of AC/PVC water tank and S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in position complete all as specified and directed
S&F in repair ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 15 mm bore dia of pipe complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 25 or 32 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 25 mm bore of pipe complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement with and including integral water proofing compound at rate of 03% by weight of cement or as per manufacturer specification complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement with and including integral water proofing compound at rate of 03% by weight of cement or as per manufacturer specification complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:3 as in ceiling surface and finished even and smooth with out using extra cement with and including integral water proofing compound at rate of 03% by weight of cement or as per manufacturer specification complete all as specified and directed.
S&F in repair grating doom 100 mm dia of PTMT (minimum weight 25 grams) complete all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed
S&F waste fittings, brass, chromium plated 32mm dia for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm / 450X 350X 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in CM 1:4 complete all as specified and directed.
M&L for joint free non skid coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed 15 mm thick in CM 1:4 complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks, etc including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 75 mm bore of pipe etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore without access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore without access door complete all as specified and directed.
S&F PVC (SWR) junction single,(Single T) equal or unequal of 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single,(Single T) equal or unequal of 110 mm bore of pipe complete all as specified and directed.
M&L PVC (SWR) vent cowl 110 mm complete all as specified and directed.
M&L PVC (SWR) floor trap of diameter of outlet 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed
M&L in repair for vitreous china wash basin, white,flat back, size 550 x 400 mm with brackets, including PVC connection of 450 mm long, PVC (HDPE) 32 mm bore waste pipe, brass couplings 32 mm CP etc. complete all as specified and directed.
S& F in repair Angle stop valve for 15 mm bore dia of pipe of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 90gms) complete all as specified and directed.
S&F in repair for 15mm bore dia of pipe pillar taps cast copper alloy, with capstan head chromium plated fancy type screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fancy type chromium plated of 15 mm bore dia of pipe complete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 300 mm complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125 mm size with or without swivel joint complete all as specified and directed.
S&F in repair stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions for 20 mm bore dia of pipe complete all as specified and directed.
S&F Water closet vitreous china squatting pan, orissa pattern 580x440 mm white with integral foot rests excluding flushing cistern and including provision of lime concrete bedding ,'P' or 'S' trap 100 mm bore , flushing pipe ,anti-syphonage pipe and connection etc and making good to floor complete all as specified and directed.
Dismantling of existing sunken treatment including plaster and M&L for water proofing treatment on existing sunken portion with the following specification :- (a) 40 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring. (b) 15 mm thick (average) plaster on sunken floor in CM (1:4) with and including water proofing compound as per manufacturer instruction complete all as specified & directed. (c) Apply bituminous primer @ 0.5 Kg / Sqm conforming to IS 3384 -1965 on prepared surface till the surface is properly impregnated. Continue...
Continue... (d) Apply hot bitumen 85/25 grade @ 1.2 Kgs/Sqm confirming to IS 702-1988. (e) Laying polymeric water proofing memberane weight not less than 3.0 Kgs /Sqm as per manufacturer instructions confirming to relevant IS. Make:- STP Ltd / Pidilite / Tikitar / IWL India Limited. (f) Apply layer of blown grade bitumen 85/25 @ 1.2 Kgs/Sqm confirming to relevant IS. (g) One spout of 40 mm GI Pipe Shall be provided in Sunken floor and sunken portion shall be filled with lean concrete Type E-2 (1:5:10) using brick Coarse aggregate.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone,concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
S&F in repair Soap dish, vitreous China white, approximate size 160x 160x90 mm fixed to plugs with chromium plated brass screws complete all as specified and directed.
S & F cast iron soil, waste and vent 75 mm bore of pipes (sand cast) in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed.
S & F cast iron soil, waste and vent 100 mm bore of pipes (sand cast) in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore with access door complete all as specified and directed.
S&F in repair CI Bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors for 75 mm bore of pipe complete all as specified and directed.
S&F in repair CI Bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors for100 mm bore of pipe complete all as specified and directed.
S&F in repair cast iron cowls for 100 mm bore of pipe complete all as specified and directed.
S&F in repair CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors for 75 mm bore of pipe complete all as specified and directed.
S&F in repair CI branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors for 100 mm bore of pipe complete all as specified and directed.
S&F mild steel flat iron as in bands straps, supports or stays for rainwater, ventilating pipes including bolt if required, hooks (stay) heavy for large gates,hook and pintle hinges,large hasps and staples, hold fasts, wall ties, hooks for hanging fans ,cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed.
JAGDAMBA CONSTRUCTION COMPANY (BID ID -3286733)
V S Constructions (BID ID -3289732)
M/S MAYANK ASSOCIATE (BID ID -3285062)
K P BUILDERS (BID ID -3290069)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .