Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹51.0 LAdmitted-Finance 2ND FLOOR 208 D BLOCK AJNARA COMPLEX VIVEK VIHAR DELHI 110095 | SHAHDARA | DELHI | 110095 | L1 | Admitted-Finance | ||
| 2 | L2₹52.0 L+₹98,944.32 (1.94%)Admitted-Finance 1853 2ND FLOOR BHAGIRATH PALACE SURYA BAZAR CHANDI CHOWK NORTH DELHI DELHI 110006 | NORTH | DELHI | 110006 | L2 | Admitted-Finance | ||
| 3 | L3₹54.7 L+₹3.8 L (7.36%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹56.0 L+₹5.0 L (9.77%)Admitted-Finance G 1 1154A MANSAROVER PARK SHAHDARA DELHI DELHI 110032 | SHAHDARA | DELHI | 110032 | L4 | Admitted-Finance | ||
| 5 | L5₹57.5 L+₹6.5 L (12.7%)Admitted-Finance HIMALAYA HOUSE D 248 SECTOR 10 NOIDA DIST G B NAGAR U P 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L5 | Admitted-Finance |
Tender Value
₹74.6 L
EMD Value
₹1.5 L
Closing Date
20 Jul 2026, 11:00 amClosed
Executive Engineer (E)
EE(E), PWD EMD (M-251) Ramesh Park Delhi
Upgradation of Apsara Boarder underpass/tunnel illumination under PWD Sub Division-3/M2533, Delhi.
2026_PWD_295281_1
48/EE(E)/PWD NES ED/2026-27
Open Tender
Electrical Works
Percentage
60 days
M-2533
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.5 L
Yes
21 Jul 2026
13 Jul 2026
20 Jul 2026
13 Jul 2026
20 Jul 2026
13 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC of LED Linear Light luminaire on the wall with the help of SS temper proof fasteners shall provide a minimum lumen output of 21000 lumens with a minimum luminous efficacy of 140 lm/W and a maximum permitted wattage of 150W, available in a correlated color temperature (CCT) of 5700K/4000. It shall be constructed from a Extruded/ Aluminium powder coated pressure die cast housing with separate IP Box for driver and optics to ensure thermal isolation, finished with corrosion-resistant nano powder coating, and equipped with a UV-stabilized polycarbonate cover for optimal light distribution. The luminaire must include an integral encapsulated high-efficiency electronic driver c, operating within a voltage range of 90-305V AC, with a power factor >0.95, THD <10%, IP66 protection, inbuilt 6kv surge protection, and integrated SPD (20KV/10KA It must also feature miswiring, over-voltage, short circuit, reverse polarity, thermal protection & input over-voltage cut-off at 320V, and auto-recovery functionality. The luminaire must have ingress protection of IP66, impact resistance of IK≥08, a minimum LED life of 50,000 burning hours with lumen maintenance as per L80, and a CRI of ≥70. It shall be suitable for installation on Underpass/Tunnel, The luminaire and driver shall comply with IEC 60598, IS 10322-5, IS 161-03/05/06/07, IEC 61000-4-5 standards, with test reports for IES, LM 79, LM 80. It shall be CE and RoHS compliant. (light to light spacing is 10mtr or as per direction of Engineer-in-Charge (For Entry & Exit Point up to 50 meter length)) | |||||
| 2SITC of LED Linear Light luminaire on the wall with the help of SS Temper proof fasteners shall provide a minimum lumen output of 21000 lumens with a minimum luminous efficacy of 140 lm/W and a maximum permitted wattage of 150W, available in a correlated color temperature (CCT) of 5700K/4000. It shall be constructed from a Extruded/ Aluminium powder coated pressure die cast housing with separate IP Box for driver and optics to ensure thermal isolation, finished with corrosion-resistant nano powder coating, and equipped with a UV-stabilized polycarbonate cover for optimal light distribution. The luminaire must include an integral encapsulated high-efficiency electronic driver c, operating within a voltage range of 90-305V AC, with a power factor >0.95, THD <10%, IP66 protection, inbuilt 6kv surge protection, and integrated SPD (20KV/10KA It must also feature miswiring, over-voltage, short circuit, reverse polarity, thermal protection & input over-voltage cut-off at 320V, and auto-recovery functionality. The luminaire must have ingress protection of IP66, impact resistance of IK≥08, a minimum LED life of 50,000 burning hours with lumen maintenance as per L80, and a CRI of ≥70. It shall be suitable for installation on Underpass/Tunnel, The luminaire and driver shall comply with IEC 60598, IS 10322-5, IS 161-03/05/06/07, IEC 61000-4-5 standards, with test reports for IES, LM 79, LM 80. It shall be CE and RoHS compliant. (light to light spacing is 15mtr or as per direction of Engineer-in-Charge (For Mid Level)) | |||||
| 3SITC of LED Linear Light luminaire on the wall with the help of SS temper proof fasteners shall provide a minimum lumen output of 5000 lumens with a minimum luminous efficacy of 145 lm/W and a minimum permitted wattage of 35W with LIFEPO4- 9.6V/6Ah, Recharge Time 24Hrs, Emergency Battery Backup Min. 30minut @18W, available in a correlated color temperature (CCT) of 5700K/4000. It shall be constructed from a Extruded/ Aluminium powder coated pressure die cast housing with separate IP Box for driver, Battery and optics to ensure thermal isolation, finished with corrosion-resistant nano powder coating, and equipped with a UV-stabilized polycarbonate cover for optimal light distribution. The luminaire must include an integral encapsulated high-efficiency electronic driver c, operating within a voltage range of 90-305V AC, with a power factor >0.95, THD <10%, IP66 protection, inbuilt 6kv surge protection, and integrated SPD (20KV/10KA It must also feature miswiring, over-voltage, short circuit, reverse polarity, thermal protection & input over-voltage cut-off at 320V, and auto-recovery functionality. The luminaire must have ingress protection of IP66, impact resistance of IK≥08, a minimum LED life of 50,000 burning hours with lumen maintenance as per L80, and a CRI of ≥70. It shall be suitable for installation on Underpass/Tunnel, The luminaire and driver shall comply with IEC 60598, IS 10322-5, IS 161-03/05/06/07, IEC 61000-4-5 standards, with test reports for IES, LM 79, LM 80. It shall be CE and RoHS compliant. (light to light spacing is 20 mtr or as per direction of Engineer-in-Charge (Emergency Battery Backup )) | |||||
| 4Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Open Area as per direction of Engineer-in-Charge) | |||||
| 4.1 | 200 Watt | - | Each | - | - |
| 5Supplying and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) | |||||
| 5.1 | 4 X 16 Sq. mm armounrd Aluminum conductor power cable | - | Mtr | - | - |
| 5.2 | 4 X 25 Sq. mm armounrd Aluminum conductor power cable | - | Mtr | - | - |
| 5.3 | 3.5 X 50 Sq. mm armounrd Aluminum conductor power cable | - | Mtr | - | - |
| 6Supplying and Fixing pole box with hot press mounted SMC pole box of inside dimension 250mm x 250mm x 160mm deep having hinged cover with MS clamp of size 25mm x 5mm flat iron (NS) Nut and bolt washers etc. including suitable locking arrangement and 1no.SPMCB with all accessories mounting system and 3 phase aluminum backlight connector 16amp capacity for terminating of 3 phase cable including gasket connection complete etc. as required | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.60 MB
BOQ_392894.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .