Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAdmitted-Finance BHAGWATI NAGAR JAMMU | L1 | Admitted-Finance | |
| 2 | L2₹1.9 L+₹19,956.40 (11.7%)Admitted-Finance GOLE GUJRAL JAMMU JAMMU | L2 | Admitted-Finance | |
| 3 | L3₹1.9 L+₹24,700 (14.5%)Admitted-Finance 235 YARD 6 NARWAL JAMMU JAMMU KASHMIR 180001 | JAMMU | JAMMU AND KASHMIR | 180001 | L3 | Admitted-Finance | |
| 4 | L4₹2.0 L+₹28,712 (16.9%)Admitted-Finance 111 MINI SHOPPING COMPLEX NEAR HOTEL ASIA NEHRU MARKET JAMMU JAMMU KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Vaibhav Engineers and Technocrates L3 | M/S GOPAL ELECTRICAL L2 | AADISHWAR ELECTRICAL AND MECHANICAL WORKS L4 | PERFECT ELECTRICAL WORKS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Impregnation / repair / rewinding of 50 HP Motor alongwith allied works at Sambal Gangera stage-0 | |||||||
| 1.10 | Repair to 50 hp motor at Sambal Gangera stage-0 by way of decoupling of motor from pump and then carrying to nearest road by way of head load for sending to workshop . Extraction of rotors and side covers from stator of motors submerged under silt and then washing of rotor and stator thoroughly followed by drying of rotor and stator . Repair to rotor shaft by welding ,turning ,and finishing for exact bearing size making keyways . The dried motor will undergo complete rewinding of horizontal squirrel cage motor with B/F Class insulating material and Super enamelled copper wire including varnishing ,heat treatment for any current leakages. Assembling complete motor and shifting to site ,coupling with pump, making proper alignment ,making connections, Testing on no load at workshop andthen full load at site . Complete job includes Cost of material ,Shifting/transportation, unloading /loading and labour charges | 1 | job | 41,500 ₹48,970 | 40,250 ₹47,495 | 42,300 ₹49,914 | 42,500 ₹42,500 Lowest |
| 1.20Repair to 70 ampere LT control panel alongwith allied works at Sambal Gangera stage-0 | |||||||
| 1.30 | Repair to 70 ampere lt control panel by way of replacement of wornout parts of 70 ampere rating LT control panel cum fault analyzer cum auto starter installed at pumping station sambal gangera stage - 0 . The job involves dismantling of all the incoming and outgoing power cables from the panel and shifting to workshop. The job involves extraction of damaged components thereafter Providing/fitting of Electronic Motor protection relay (digital) with inbuilt protection of voltage and current related faults, 2no. spare contactor kits of 70 ampere rating and 1 no. spare contactor kit of 50 ampere rating. conforming to same rating and specifications as per old sample. Providing and fitting of Digital voltmeter- 1 no. and amperemeter-1no. each along with replacement of internal control wiring. Shifting the panel back to site, fitment and testing of the equipment, without load and thereafter on full load. Job includes the cost of material / labour charges, hire charges of tools and tackles etc. Rebate, if any, should be quoted separately. | 1 | job | 32,500 ₹38,350 | 31,780 ₹37,500.4 | 33,800 ₹39,884 | 34,000 ₹34,000 Lowest |
| 1.40Repair to 63 KVA voltage stabilizer alongwith allied works at Sambal Gangera stage-0 | |||||||
| 1.50 | Repair of 63 kva voltage stabilizer at Pumping Station Sambal Gangera stage-0 by way of disconnecting all electrical connection and making temporary arrangement for running the system . Dragging the stabilizer outside the pump room by deploying manual labour and carrying of 63 kva voltage stabilizer upto the nearest roadside by way of head load using manual labour and then shifting to the workshop for further repair . Unfastening of nuts bolts and opening the top cover then extracting the coils with the chain block . Job also includes cleaning of silt from the coils extracted of the stabilizer , cleaning of tank , Replacement of 02 nos. Coils with new coils of superior quality copper complete with insulation and varnish . Replacement of Ampere meter – 01 no. , Voltmeters – 02 no and other impaired parts like selector switches – 03 no. ,rotor switches – 03 no. , electrical wiring etc. Job futher include filling of 63 kva voltage stabilizer with fresh 150 litres fresh T- Oil . Lowering of internal assembly inside the chamber and closing the top cover by fastening the nuts and bolts . Shifting the voltage stabilizer from workshop to Pumping Station and then testing of voltage stabilizer at both no load and full load . Complete job includes cost of material, labour, carriage ,hire charges of tools tackles etc. Rebate, if any, should be quoted separately. | 1 | job | 41,500 ₹48,970 | 40,250 ₹47,495 | 42,300 ₹49,914 | 42,500 ₹42,500 Lowest |
| 1.60Providing / fitting of electro-mechanical components alongwith allied works at Sambal Gangera stage-0 | |||||||
| 1.70 | Providing /Fitting of Electro-mechanical Components at Sambal Gangera Stage-0 . Job includes providing , fitting and laying of 80 mm dia suction pipes washed away during flood for 2 no. pumpsets along with footvalves by way of fabrication , welding , flanging of pipes, providing/fitting of nuts & bolts . Job further includes providing/fitting of 160 Ampere mccb – 2no. at pumping station Sambal Gangera STAGE-0 by way of shutting the power supply and then installing the new mccbs and further testing on no load and full load conditions. Complete job includes Cost of material ,Shifting/transportation, unloading /loading and labour charges | 1 | job | 49,500 ₹58,410 | 48,700 ₹57,466 | 50,000 ₹59,000 | 51,000 ₹51,000 Lowest |
Tender Value
₹2 L
EMD Value
₹4,000
Closing Date
8 Jul 2026, 3:00 pmClosed
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
UDHAMPUR
Impregnation / repair / rewinding of 50 HP Motor alongwith allied works at Sambal Gangera stage-0, repair to 70 ampere LT control panel alongwith allied works at Sambal Gangera stage-0, repair to 63 KVA voltage stabilizer alongwith allied works at Sa
2026_PHE_314213_1
ENIT NO. 31 OF 2026-27
Open Tender
Repair and Maintenance Works
Item Rate
30 days
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
Impregnation / repair / rewinding of 50 HP Motor alongwith allied works at Sambal Gangera stage-0, repair to 70 ampere LT control panel alongwith allied works at Sambal Gangera stage-0, repair to 63 KVA voltage stabilizer alongwith allied works at Sa
2 documents required · 2 mandatory
₹500
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
₹4,000
25 Aug 2026
1 Jul 2026
9 Jul 2026
1 Jul 2026
8 Jul 2026
1 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Impregnation / repair / rewinding of 50 HP Motor alongwith allied works at Sambal Gangera stage-0 | - | - | - | - |
| 0.0 | Repair to 50 hp motor at Sambal Gangera stage-0 by way of decoupling of motor from pump and then carrying to nearest road by way of head load for sending to workshop . Extraction of rotors and side covers from stator of motors submerged under silt and then washing of rotor and stator thoroughly followed by drying of rotor and stator . Repair to rotor shaft by welding ,turning ,and finishing for exact bearing size making keyways . The dried motor will undergo complete rewinding of horizontal squirrel cage motor with B/F Class insulating material and Super enamelled copper wire including varnishing ,heat treatment for any current leakages. Assembling complete motor and shifting to site ,coupling with pump, making proper alignment ,making connections, Testing on no load at workshop andthen full load at site . Complete job includes Cost of material ,Shifting/transportation, unloading /loading and labour charges | 1 | job | - | - |
| 0.9 | Repair to 70 ampere LT control panel alongwith allied works at Sambal Gangera stage-0 | - | - | - | - |
| 0.0 | Repair to 70 ampere lt control panel by way of replacement of wornout parts of 70 ampere rating LT control panel cum fault analyzer cum auto starter installed at pumping station sambal gangera stage - 0 . The job involves dismantling of all the incoming and outgoing power cables from the panel and shifting to workshop. The job involves extraction of damaged components thereafter Providing/fitting of Electronic Motor protection relay (digital) with inbuilt protection of voltage and current related faults, 2no. spare contactor kits of 70 ampere rating and 1 no. spare contactor kit of 50 ampere rating. conforming to same rating and specifications as per old sample. Providing and fitting of Digital voltmeter- 1 no. and amperemeter-1no. each along with replacement of internal control wiring. Shifting the panel back to site, fitment and testing of the equipment, without load and thereafter on full load. Job includes the cost of material / labour charges, hire charges of tools and tackles etc. Rebate, if any, should be quoted separately. | 1 | job | - | - |
| 0.9 | Repair to 63 KVA voltage stabilizer alongwith allied works at Sambal Gangera stage-0 | - | - | - | - |
| 0.0 | Repair of 63 kva voltage stabilizer at Pumping Station Sambal Gangera stage-0 by way of disconnecting all electrical connection and making temporary arrangement for running the system . Dragging the stabilizer outside the pump room by deploying manual labour and carrying of 63 kva voltage stabilizer upto the nearest roadside by way of head load using manual labour and then shifting to the workshop for further repair . Unfastening of nuts bolts and opening the top cover then extracting the coils with the chain block . Job also includes cleaning of silt from the coils extracted of the stabilizer , cleaning of tank , Replacement of 02 nos. Coils with new coils of superior quality copper complete with insulation and varnish . Replacement of Ampere meter – 01 no. , Voltmeters – 02 no and other impaired parts like selector switches – 03 no. ,rotor switches – 03 no. , electrical wiring etc. Job futher include filling of 63 kva voltage stabilizer with fresh 150 litres fresh T- Oil . Lowering of internal assembly inside the chamber and closing the top cover by fastening the nuts and bolts . Shifting the voltage stabilizer from workshop to Pumping Station and then testing of voltage stabilizer at both no load and full load . Complete job includes cost of material, labour, carriage ,hire charges of tools tackles etc. Rebate, if any, should be quoted separately. | 1 | job | - | - |
| 0.0 | Providing / fitting of electro-mechanical components alongwith allied works at Sambal Gangera stage-0 | - | - | - | - |
| 0.0 | Providing /Fitting of Electro-mechanical Components at Sambal Gangera Stage-0 . Job includes providing , fitting and laying of 80 mm dia suction pipes washed away during flood for 2 no. pumpsets along with footvalves by way of fabrication , welding , flanging of pipes, providing/fitting of nuts & bolts . Job further includes providing/fitting of 160 Ampere mccb – 2no. at pumping station Sambal Gangera STAGE-0 by way of shutting the power supply and then installing the new mccbs and further testing on no load and full load conditions. Complete job includes Cost of material ,Shifting/transportation, unloading /loading and labour charges | 1 | job | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.00 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_1017356.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .