| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC 110 245 NEHRU NAGAR KANPUR UTTAR PRADESH 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.1 L+₹37,074.91 (0.89%)Rejected-Finance JAJJAR KOTLI JAMMU J K 151222 | JAMMU | JAMMU | J K | 151222 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹42.7 L+₹91,070.51 (2.18%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Jun 2025, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur, PO-Garhi, PIN-182121
Repair/ replacement pipe line control valves, pumping system and switch gear installed at Garhi Cantt and nearby areas under GE (U) Udhampur
2025_MES_705746_1
GE/U-14/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹90,000
9 Jul 2025
28 Apr 2025
4 Jun 2025
28 Apr 2025
2 Jun 2025
18 May 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth,foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. and taking out/laying of pipe lines of soft/loose soil. Complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers, each layer not exceeding 25cm thick after pipes have been laid and tested complete, all as specified and directed by Engineer-in-Charge
Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete, all as specified and directed by Engineer-in-Charge
Taking up or down old unseviceable GI pipe of size 150 mm dia including all fittings all as specified and directed by Engineer-in-Charge.
All as per ser item 04 here-in-before but of 100 mm dia
All as per ser item 04 here-in-before but of 80 mm dia
All as per ser item 04 here-in-before but of 50 mm dia
All as per ser item 04 here-in-before but of 40 mm dia
All as per ser item 04 here-in-before but of 25 mm dia
All as per ser item 04 here-in-before but of 20 mm dia
All as per ser item 04 here-in-before but of 15 mm dia
Supply & fixing GI pipes of size 150 mm dia, medium grade, galvanized conforming to IS: 1239, ISI Marked with all fitting such as bends, tees, nipples, union and sockets, clamps etc laid in trenches, under floor/walls etc complete all as specified and directed by Engr-in-Charge. Make:- TATA, Jindal, BST, Prakash Surya
All as per ser item 12 here-in-before but of 100 mm dia
All as per ser item 12 here-in-before but of 80 mm dia
All as per ser item 12 here-in-before but of 50 mm dia
All as per ser item 12 here-in-before but of 40 mm dia
All as per ser item 12 here-in-before but of 25 mm dia
All as per ser item 12 here-in-before but of 20 mm dia
All as per ser item 12 here-in-before but of 15 mm dia
Refixing GI pipe obtained from Item No. 04 above and connections in new or old position (walls, trenches, ceiling and floors etc) of size 150 mm dia complete including main branch connections all as specified and directed by Engr-in-Charge.
All as per ser item 20 here-in-before but of 100 mm dia obtained from item No. 05.
All as per ser item 20 here-in-before but of 80 mm dia obtained from item No. 06.
All as per ser item 20 here-in-before but of 50 mm dia obtained from item No. 07.
All as per ser item 20 here-in-before but of 40 mm dia obtained from item No. 08.
All as per ser item 20 here-in-before but of 25 mm dia obtained from item No. 09.
All as per ser item 20 here-in-before but of 20 mm dia obtained from item No. 10
Supply and fixing MS ERW Class 'B' distribution header of bore 400 mm having wall thickness 6 mm with permissible tolerance ± 10% conforming to IS-3589, ISI marked 9.0 meter long with welded flanges, MS flanges 20mm thick on both ends closed with end plates including provision of 04 nos inlets (3 x 200 mm & 1 x 250 mm) from Filter bed side and 04 nos outlets at distribution side (3X200mm) & (1x150mm) made up og MS/GI Pipe with flanged end including painting of complete header with one coat of red oxide primer and two coats of synthetic enamel paint of black colour complete all as specified and directed by Engr-in-Charge.
Mounting of header at a height of 1.2 metre above the ground level on PCC pillar of dimension 0.5x0.5x1.8 meter (0.6 meter depth & 1.2 meter height above ground) are as under the followings all as specified and directed by Engr-in-Charge.
(a) Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of GI/CI pipes and getting out in hard / dense soil complete all as specified and directed by Engr-in-Charge.
(b) Returning filling in and including spreading, levelling,watering and well ramming in layers not exceeding 25 cm all as specified and directed by Engr-in-Charge.
(c) Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting piont all as specified and directed by Engr-in-Charge.
(d) M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) cement concrete in as in foundation filling of pillar all as specified and directed by Engr-in-Charge.
(e) M&L for RCC foundation, M-25 type (using 20 mm graded aggregates) including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge.
(f) M&L for RCC Column, M-25 type (using 20 mm graded aggregates) complete all as specified and directed by Engr-in-Charge.
(g) Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
(h) Grouting of nut bolts in the PCC pillar to support the header on both side with clamps complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing MS ERW pipe class 'B' of bore 200 mm having wall thickness 6 mm with permissible tolerance ± 10% conforming to IS-3589, ISI marked alongwith flange joints including nut bolts, washers, flanges, etc laid in trenches/ along road/ on surface/ slopes/pillars/ culverts/ causeways etc, complete all as specified directed by Engr-in-Charge. Note: Circular welding charges for flange shall be deemed included in the quoted rates.
Supply and fix in replacement cast iron sluice valve suitable of size 250 mm (PN 1.6) as per IS : 14846 with iron wheel head both end flanged, non rising type and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,complete all as specified and directed by Engr-in-Charge.
All as per ser item 30 here-in-before but of size 200 mm dia
All as per ser item 30 here-in-before but of size 150 mm dia
All as per ser item 30 here-in-before but of size 100 mm dia
All as per ser item 30 here-in-before but of size 80 mm dia
Supply and fix in replacement of cast iron non return valve suitable for 150 mm bore pipe heavy duty both end flanged of pressure rating PN 1.6 as per IS:5312 and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,Complete all as specified and directed by Engr-in-Charge.
All as per ser item 35 here-in-before but of size 100 mm dia.
All as per ser item 35 here-in-before but of size 80 mm dia.
Supply and fixing in repacement of Cast iron Foot valve Flanged with strainer as per IS 4038 of 150 mm dia including all type of fitting & taking down the old existing, complete all as specified and as directed by Engr-in-Charge.
All as per srl item no. 38 here-in-before but of size 100mm
Supply and fix in replacement of cast iron air release valve with two air outlets of size 100 mm dia as per IS 14845 including all jointing materials like high pressure rubber gasket nuts, bolts, washers with arrangement for fixing, including taking down complete,complete all as specified and directed by Engr-in-Charge.
All as per ser item 40 here-in-before but of size 80 mm dia.
Decoupling, disconnecting sluice valve of size 300 mm dia, taking down from pipe line, opening all parts for refacing, regrinding and refixing at its original location including replacement of unsv parts, cleaning, repacking stuffing box of sluice valve and spindle including fixing and testing complete all as spacified and directed by Engr-in-Charge. Note :- (i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of spare parts shall be measured and paid separately under respective items:-
(a) Replacement of Hand wheel
(b) Replacement of SS Stem & GM Nut
(c) Replacement of Cap
(d) Replacement of Flange Rubber Gasket
(e) Replacement of Nut & Bolt + 2 Washers
Decoupling, disconnecting sluice valve of size 250 mm dia, taking down from pipe line, opening all parts for refacing, regrinding and refixing at its original location including replacement of unsv parts, cleaning, repacking stuffing box of sluice valve and spindle including fixing and testing complete all as directed by Engr-in-Charge. Note :- (i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of spare parts shall be measured and paid separately under respective items:-
(a) Replacement of Hand wheel
(b) Replacement of SS Stem & GM Nut
(c) Replacement of Cap
(d) Replacement of Flange Rubber Gasket
(e) Replacement of Nut & Bolt + 2 Washers
Decoupling, disconnecting sluice valve of size 200 mm dia, taking down from pipe line, opening all parts for refacing, regrinding and refixing at its original location including replacement of unsv parts, cleaning, repacking stuffing box of sluice valve and spindle including fixing and testing omplete all as directed by Engr-in-Charge. Note :- (i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of spare parts shall be measured and paid separately under respective items:-
(a) Replacement of Hand wheel
(b) Replacement of SS Stem & GM Nut
(c) Replacement of Cap
(d) Replacement of Flange Rubber Gasket
(e) Replacement of Nut & Bolt + 2 Washers
Decoupling, disconnecting sluice valve of size 150 mm dia, taking down from pipe line, opening all parts for refacing, regrinding and refixing at its original location including replacement of unsv parts, cleaning, repacking stuffing box of sluice valve and spindle including fixing and testing omplete all as directed by Engr-in-Charge. Note :- (i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of spare parts shall be measured and paid separately under respective items:-
(a) Replacement of Hand wheel
(b) Replacement of SS Stem & GM Nut
(c) Replacement of Cap
(d) Replacement of Flange Rubber Gasket
(e) Replacement of Nut & Bolt + 2 Washers
Decoupling, disconnecting sluice valve of size 100 mm dia, taking down from pipe line, opening all parts for refacing, regrinding and refixing at its original location including replacement of unsv parts, cleaning, repacking stuffing box of sluice valve and spindle including fixing and testing omplete all as directed by Engr-in-Charge. Note :- (i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of spare parts shall be measured and paid separately under respective items:-
(a) Replacement of Hand wheel
(b) Replacement of SS Stem & GM Nut
(c) Replacement of Cap
(d) Replacement of Flange Rubber Gasket
(e) Replacement of Nut & Bolt + 2 Washers
Decoupling, disconnecting sluice valve of size 80 mm dia, taking down from pipe line, opening all parts for refacing, regrinding and refixing at its original location including replacement of unsv parts, cleaning, repacking stuffing box of sluice valve and spindle including fixing and testing omplete all as directed by Engr-in-Charge. Note :- (i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of spare parts shall be measured and paid separately under respective items:-
(a) Replacement of Hand wheel
(b) Replacement of SS Stem & GM Nut
(c) Replacement of Cap
(d) Replacement of Flange Rubber Gasket
(e) Replacement of Nut & Bolt + 2 Washers
M&L for repair to leaking run lead joints in CI/DI spigot and socket end pipe line of 200 mm to 250 mm bore by providing new lead ,using good quality spun yarn, including necessary excavation, returning filling in trenches in any type of soil,bailing out water, and at any depth complete all as specified and directed by Engr-in-Charge. Note:- (i) Contractor fully responsible for necessory excavation for jointing work required T&P equipment, mechanical excavation work and man power at site requirement with making good disturbed surfaces of road/wall/floor etc and matching with existing surface included quoted rate. (ii) Required extra fittings/pipe will be measured and paid separately. (iii) Lead wool shall be measured and paid separately under respective items of Sch A.
All as per ser item 48 here-in-before but of dia 100 mm to 150 mm bore pipe
M&L for repair to leaking GI pipe line of size 80 mm bore by providing necessary fitting such as socket, Tee, Elbow,etc including necessary excavation, returning filling in trenches in any type of soil,bailing out water, and any depth complete all as specified and directed by Engr-in-Charge. Note:- (i) Contractor fully responsible for necessory excavation for jointing work required T&P equipment, mechanical excavation work and man power at site requirement with making good disturbed surfaces of road/wall/floor etc and matching with existing surface included quoted rate. (ii) Required extra pipe will be measured and paid separately.
All as per ser item 50 here-in-before but of size 40 mm to 50 mm bore pipe.
All as per ser item 50 here-in-before but of size 15 mm to 25 mm bore pipe.
Material and labour for repair to leaking flanged/circular welding joints of 100 to 200 mm bore MS/GI pipe line by providing rubber or fiber board gasket, new flanges if required at site, nut bolts, washers and welding works where required etc, including necessary excavation, returning filling in trenches in any type of soil, bailing out water, and any depth complete all as specified and directed by Engr-in-Charge. Note:- (i) Contractor fully responsible for necessory excavation for jointing work required T&P equipment, mechanical excavation work and man power at site requirement with making good disturbed surfaces of road/wall/floor etc and matching with existing surface included quoted rate. (ii) Required extra pipe will be measured and paid separately.
All as per ser item 53 here-in-before but of dia 250 to 300 mm bore pipe
M&L for cutting of existing road for crossing of MS/DI/CI/GI pipes for laying of any size pipes including necessary exacavation and earth work including repairing the same as per existing complete all as specified and directed by Engr-in-Charge.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) cement concrete in as in foundation filling of pole & stay complete all as specified and directed by Engr-in-Charge.
M&L for Premix ready mix road repair patching compound for instant road repair manufactured with a blend of bitumen, aggregates and high grade polymer to ensure immediate bonding with existing surface available in bag of 25 Kg complete all as specified and directed by Engr-in-Charge.
S&F of Gun-metal, globe or gate valves, 50 mm dia , heavy duty, with iron wheel head, screwed both ends conforming to IS: 778 (ISI marked), complete all as specified & directed by Engr-in-Charge.
All as per ser item No 58 above but upto 40 mm bore.
All as per ser item No 58 above but upto 25 mm bore.
All as per ser item No 58 above but upto 20 mm bore.
All as per ser item No 58 above but upto 15 mm bore.
Supply and fixing GI fittings medium grade ISI marked including complete all as required at site and as directed by Engr-in-Charge.
(a) Elbow 20mm
(b) Elbow 25mm
(c) Elbow 40mm
(d) Elbow 50mm
(e) Elbow 80mm
(f) Socket 20mm
(g) Socket 25mm
(h) Socket 40mm
(i) Socket 50mm
(j) Socket 80mm
(k) Union 20mm
(l) Union 25mm
(m) Union 40mm
(n)Union 50mm
(o) Union 80mm
(p) Elbow reducer 25 x 20mm
(q) Elbow reducer 20 x 15mm
(r) Elbow reducer 40 x 25mm
(s) Socket reducer 25x20mm
(t) Nipple 15mm
(u) Nipple 20mm
(v) Nipple 25mm
(w) Nipple 40mm
(x) Nipple 50mm
(y) Nipple 80mm
(z) Tee 20mm
(aa) Tee 25mm
(ab) Tee 25x20mm
(ac) Dead plug 20mm
(ad) Dead plug 25mm
(ae) Dead plug 40mm
(af) Dead plug 50mm
(ag) Dead plug 80mm
(ah) Pig lead
(aj) Jute Spurn Yarn
Decoupling, disconnecting suction line and discharge line taking down from foundation, dismounting from base channels strip opening all parts, derusting, cleaning, overhualing comprising of repairs/replacement of unserviceable parts of pump sets and taking to workshop (if reqd) for repairs. Reassembling of pump set mounting and fixing on base channel, recoupling of suction & discharge line realignment commissioning and testing in respect of centrifugal/multistage pump of capacity 60/75 HP all as specified and directed by Engineer-in-charge. Note :(i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of parts shall be measured and paid separately under respective item of sch A.
All as per ser item No 64 but capacity 30/40/50 HP.
All as per ser item No 64 but capacity 15/20/25 HP.
S&F New parts for single/double/multistage pumps of capacity 60/75 HP as per manufacturer's composition of existing make of pump as below all as specified and directed by Engr-in-Charge.
(a) Impeller, MOC: CI
(b) Shaft, MOC: CS
(c) Shaft sleeves, MOC: BR
(d) Casing bearing, MOC: CI
(e)Bearing housing/Bearing cover, MOC: CI
(f) Gland cup with nut and bolts, MOC: CI
(g) Jaw/Spider/Star/Tyre Coupler, MOC: CI
(h) Inter stage ring/Shaft sleeve nut, MOC: BR
(j) O Ring, MOC: Neopren rubber
S&F New parts for single/double/multistage pumps of capacity 30/40/50 HP as per manufacturer's composition of existing make of pump as below all as specified and directed by Engr-in-Charge.
(a) Impeller, MOC: CI
(b) Shaft, MOC: CS
(c) Shaft sleeves, MOC: BR
(d) Casing bearing, MOC: CI
(e)Bearing housing/Bearing cover, MOC: CI
(f) Gland cup with nut and bolts, MOC: CI
(g) Jaw/Spider/Star/Tyre Coupler, MOC: CI
(h) Inter stage ring/Shaft sleeve nut, MOC: BR
(j) O Ring, MOC: Neopren rubber
S&F New parts for single/double/multistage pumps of capacity 15/20/25 HP as per manufacturer's composition of existing make of pump as below all as specified and directed by Engr-in-Charge.
(a) Impeller, MOC: CI
(b) Shaft, MOC: CS
(c) Shaft sleeves, MOC: BR
(d) Casing bearing, MOC: CI
(e)Bearing housing/Bearing cover, MOC: CI
(f) Gland cup with nut and bolts, MOC: CI
(g) Jaw/Spider/Star/Tyre Coupler, MOC: CI
(h) Inter stage ring/Shaft sleeve nut, MOC: BR
(j) O Ring, MOC: Neopren rubber
Lath/Mchining works of any type at workshop required for balancing of impller/for fixing of new parts to existing shfts required for proper setting and smooth functioning to achieve desired discharge of the pump for 60 to 75 HP pump complete all as specified and as directed by Engr-in-charge.
All as per srl item No. 70 but capacity of 30 to 50 HP motor
All as per srl item No. 70 but capacity of 15 to 25 HP motor
Disconnecting electric connection of 60/75 HP motor, removing the UNSV motor from existing place by unscrewing the foundation bolts and nuts decoupling from the pump, setting aside and transporting to workshop for repairs including dismantling the motor,cutting/taking out burnt winding of stator, rotor, cleaning the slots including repairing of slots by filling copper through any process in slots (if reqd), transporting back after repair/winding & re-assembling the same. Cost of loading, unloading & transportation shall be deemed included in the quoted rates. complete all as directed by Engineer-in-Charge. Note: (a) Winding of motor stator & rotor shall be measured & paid separately. (b) The rates quoted shall be deemed to include the cost of including/unloading, transportation, grease, nuts , bolts and washers of any size and shape as required at site and refixing of serviceable motor duly functional and testing complete at its existing location/position complete all as specified and directed.
All as per srl item no. 73 but capacity 30/40/50 HP motor
All as per srl item no. 73 but capacity of 10/15/20/25 HP motor
Removing the burnt out winding from the rotor and stator, cleaning the slots, providing high quality of class'B' paper insulation inside the slots, rewinding the motor of capacity 75/60/50/40/30/25/20/15/12/10/5/3/2/1.5 HP with super enamel copper wire of same size and guage as per existing rapping up with high quality cotton tape and varnising with super quality oil including drying upto desired temperature and desired time. Note:- Cost of labour for winding deemed to be included in the rate quoted. Make : Atlas/Devi Dayal or equivalent
Supply and fixing in repair of 0.5 to 2 HP pumpset (including motor) by taking out from foundation, dismounting from base channels, strip opening all parts derusting, cleaning, overhualing etc for complete repair/replacement of spare parts such as impeller, shaft winding, bearings coupling , body etc and after repair reassembling of pumpset mounting and fixing on base channel , recoupling of suction & discharge line realignment , commissioning and testing complete all as specified and directed by Engr-in-Charge.
M&L for replacement complete unsv/damaged parts including outer both lower & upper casing, impeller, shaft, gland cup, bearing housing, casing bearing etc of existing make of 50 HP split case centrifugal pump of discharge capacity 19 lps & head 68 mtr. Pump Model- DSM80/36,Stages 2. MOC - CI260(012)/BR LTB2(110)/40C8(053), prime mover rating 30 kW complete all as specified and directed by engr-in-charge. Make: Kirloskar, Mather & Platt, Crompton, KSB, etc
M&L for replacement Twin lobe Air Blower set of capacity 510 cum/hr, Pressure: 0.35 Kg/sqcm, Blower speed: 1650 RPM, Motor speed: 1440 RPM (15HP) including common base frame for motor and machine, Discharge silencer (M.S Fabricated), Suction Silencer (M.S Fabricated), Non return valve (Wafer Type), Safety valve (Spring Loaded) (Brass), Suction Filter (Grobe Type), V-belt guard (M.S), OIL (ENCLO 320), V-belt drive consisting of drive and driven, PULLY, Motor 15 HP (Make: Kirloskar, Crompton Greaves) 3Phase RPM 1440 complete all as specified and directed by engr-in-charge. Make: Shree Ambika Engineering, Beta, Uvika blowers or equivalent as approved by accepting officer.
M&L for replacement of Slow speed agitator (Alum mixer) Liquid Handled: Alum, Shaft length 850mm below mounting plate, Shaft Dia. 25 mm, Impeller Dia. 250mm PBT Type - Three Blade , Impeller - 2 Nos., Output RPM 150 RPM, Gear box details: Worm Type, Output RPM 150, Ratio 10:1, 1HP /0.75 kw, 4pole, motor , SF- 2, Model- ELMN50/63-. Service tank of capacity 500 ltrs. Motor Data : Drive Rating HP / KW 1Hp / 0.75 Kw, Drive Details 4pole, 1440 RPM, STD. TEFC, Flange mounted, Vertical, IP55, 50hz, 415volts, 3 Phase, IE2, Non Flame proof. Make Crompton Greaves, Kirloskar, KSB. MOC of Shaft SS316, MOC of Impeller SS316,Mounting Bearing Housing M.S. Painted, including 500 Ltrs. Tank complete all as specified and directed by Engr-in-charge. Make: Dynamic Equipments Pvt. Ltd, Verito Engineering Pvt Ltd, RECKON Techno Dosing Pumps And Systems, Rudraksha Engineering or equivalent as approved by accepting officer.
S&F of Pump bearing No. 6307 C3.
S&F of Pump bearing No. 6308 2RS1/C3.
S&F of Pump bearing No. 3307 ATN9.
S&F of Motor bearing No. 6306 2Z/C3.
S&F of Motor bearing No. 7310 BEP.
S&F in replacement of OFF load change over switch 800 Amps, 415 volts 4 pole (Side handle operated) with stainless steel enclosure inculding taking down the old existing change over switch complete all as directed by Engineer -in-Charge.
All as per srl item no. 86 here-in-before but of capacity 320 Amps.
All as per srl item no. 86 here-in-before but of capacity 200 Amps.
S&F in replacement of ON load change over switch 400 Amps, 415 volts 4 pole with stainless steel enclosure inculding taking down the old existing change over switch complete all as directed by Engineer -in-Charge.
All as per srl item no. 89 here-in-before but of capacity 320 Amps.
All as per srl item no. 89 here-in-before but of capacity 200 Amps and side handle operated.
All as per srl item no. 89 here-in-before but of capacity 125 Amps.
S&F in relpacement of load line MCCB 800 Amps 4 pole 415 volts with adjustable thermal and fixed magnetic setting of breaking capacity 35/36KA, Ics=100% Icu including taking down the old existing MCCB complete all as directed by Engr in charge.
All as per srl item no. 93 here-in-before but of capacity 630 Amps.
All as per srl item no. 93 here-in-before but of capacity 320 Amps.
All as per srl item no. 93 here-in-before but of capacity 250 Amps.
All as per srl item no. 93 here-in-before but of capacity 200 Amps.
All as per srl item no. 93 here-in-before but of capacity 160 Amps.
All as per srl item no. 93 here-in-before but of capacity 100 Amps.
S&F in replacement of power contactor 3 pole with AC coil AC-3 duty rating at 415 Volts 50 Hz suitable for 55kW/75 HP Motor.
All as per srl item no. 100 here-in-before but suitable for 37kW/50 HP.
All as per srl item no. 100 here-in-before but suitable for 18.5kW/25 HP.
M&L in replacement of PVC insulated heavy duty industrial cables single core copper conductor(flexible) PVC insulated cable 1100 volt nominal area of conductor 95 sqmm inculding taking down existing old unserviceable cable of complete all as directed by Engr -in-charge.
All as per srl item no. 104 here-in-before but of size 70 sqmm.
All as per srl item no. 104 here-in-before but of size 50 sqmm.
All as per srl item no. 104 here-in-before but of size 35 sqmm.
All as per srl item no. 104 here-in-before but of size 25 sqmm.
All as per srl item no. 104 here-in-before but of size 16 sqmm.
M&L for copper thimble suitable for 95 Sqmm single core copper cable including taking down the existing unserviceable one complete, all as specified & directed by Engr-in-Charge.
All as per srl item no. 109 here-in-before but of size 70 sqmm.
All as per srl item no. 109 here-in-before but of size 50 sqmm.
All as per srl item no. 109 here-in-before but of size 35 sqmm.
All as per srl item no. 109 here-in-before but of size 25 sqmm.
All as per srl item no. 109 here-in-before but of size 16 sqmm.
M&L for aluminium thimble of 300 sqmm size for cables all as specified and directed by Engr-in-Charge
All as per srl item no. 115 here-in-before but of size 150 sqmm.
All as per srl item no. 115 here-in-before but of size 50 sqmm.
S&F in replacement digital type Ampere meter (96mm x96 mm) complete with suitable CTs 0-300 Amps as per existing,complete all as specified and directed by Engineer - in - Charge.
S&F in replacement of digital type volt meter (96mm x96 mm) 0-500 volts as per existing, complete all as specified and directed by Engineer - in - Charge.
S&F in replacement of indicating lamps RYB as per existing, complete all as specified and directed by Engineer - in - Charge.
S&F in replacement of Push button as per existing, complete all as specified and directed by Engineer - in - Charge.
S&F in replacement of Twin Touch with Black centre strip type Push button as per existing, complete all as specified and directed by Engineer - in - Charge.
(a) Phase Changeover switches
Supply and laying DWC (Double wall corruguated) pipe 40/32 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing complete all as specified and directed by Engr-in-charge
All as per srl item no. 124 here-in-before but of size 77/63 mm.
Supply & laying of Corrugated flexible pipe of 40 mm dia, min 2mm thick used for wiring purpose all as specified and directed, complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of Terminal box including connection plate suitable for 75/60/50 HP motor as per existing specification including taking down the old existing terminal box complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of terminal box including connection plate suitable for 40/30/25/20 HP motor as per existing specification including taking down the old existing terminal box complete all as specified and directed by Engr-in-charge.
M & L for painting of pump and motor, frame including surface preparation of capacity 20/25/30/40/50/75 HP by scrapping with emery paper and painting with one coat of red oxide primer and two coats of synthetic enamel paint of existing colour of approved make to the satisfaction of Engr in Charge complete all as specified and directed by Engr-in-charge.
M & L for painting of Header of dia up to 300mm with inlet, outlet, sluice valve, NRV etc including surface preparation by scrapping with emery paper and painting with one coat of red oxide primer and two coats of synthetic enamel paint of existing colour of approved make to the satisfaction of Engr in Charge complete all as specified and directed by Engr-in-charge. Note: Marking with white colour on each outlet is included.
M&L for flex banner supported with iron frame of size 1.0 mtr x 0.6 mtr, about the machinery installed in different instalations such as Cap, discharge, MES No, Year of installation and head of the machinery on the blue background with white colour. complete all as specified and directed by Engr-in-charge.
M&L for flex banner supported with iron frame of size 1.0 mtr x 0.6 mtr, about the Filter bed at Jib filter plant such as Type, Cap, etc on the blue background with white colour. complete all as specified and directed by Engr-in-charge.
S&F in replacement of Gland Packing Rope type 3 of size 8 mm made of asbestos grip with silicon complete all as specified and directed by Engr-in-Charge. Make : Turner/ Champion/Jyoti
All as per srl item no. 133 here-in-before but of size 10 mm.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engr-in-charge.
S&F in replacement of MS stud bolts of existing size suitable for pumps and motors of various capacity installed at installations complete all as specified and directed by Engr-in-charge.
S&F in replacement of grouting nuts and bolts of existing size suitable for pumps and motors, foundation of various capacity installed at installation & sluice/Non return/Foot/Air release valve flange complete all as specified and directed by Engr-in-charge.
Supply fabrication and fixing MS joints like Flanged, bends, Tee, Tapers, collars, elbow, tail piece (any type) caps, plugs for 80 mm to 300 mm bore pipe including taking down old existing, complete all as specified and directed by Engr-in-charge. Note: M&L charges for required welding shall be deemed included in the quoted rates.
Supply only lithium base grease AP3 in 20 Kg pack suitable for application to ball bearing with operating temperature 30 to 120 degree celsius drop point 174 degree celsius, colour light fawn complete all as specified and directed by Enr-in-Charge
Supply only cotton waste coloured Grade "A' for cleaning rags in 25 Kgs bag complete all as specified and directed by Engr-in-Charge
Repair/replacement of parts of Air compressor pressure rating upto 0.35Kg/cm2 of capacity 15 HP including repair/replacemrnt of Pully V Belt, Ball Bearing, Roller bearing, Piston ring, Oil seal, Oil level glass, Suction air filter, Air compressor shaft welding , turning , grinding, Outer distance bush, Pressure ring, CI Belt Shaft Pulley and Re-greasing all grease points complete all as specified and directed by Engr-in-Charge. Note: (i) Charges for dismentaling, disconnecting, transportation to warehouse (Tro/Fro) included in quoted rate. (ii) Charges for supply & fix in replacement of a/m defective parts should be included in quoted rate.
Supply & pouring Compressor Oil (premium grade turbine oil with an ISO viscosity grade 32 or 46) in air blower as directed by Engr-in-charge.
S&F V-belt for Air compressor/blower size B 1542 Lp/ B59 as per IS: 2494 (Part-1) complete all as specified and directed by Engr-in-charge.
M&L for painting complete outer surrounding of Over head tank in Tiranga Colour including writing of "SAVE WATER, SAVE LIFE " in blue colour on center white colour as directed by Engr-in-charge.
Opening, maintenance and general servicing of Servo voltage stablizers of different makes (Rating from 100 KVA to 500 KVA) including removal of sludge from disserstate coils, buck boost transformers, tightening of all nut bolts, cleaning of stablizers coils, checking and servicing of servo mechanism, gear synchronising system, automatic voltage regulator circuits and other allied electrical components complete all as specified and directed by Engr-in-charge. Note : Rate quoted by contractor is inclusive of following items:- (a) Servo motor with RC network having torque upto 3 kg/cm - 01 Nos (b) Servo motor with RC network having torque upto 10 kg/cm - 01 Nos (c) Electronic cntrol card for automatic voltage regulation - 01 Nos (d)Transformer oil -35 ltrs (e) Voltmeter 0-500 volt capacity - 01 Nos (f) Ammeter CT Operated - 01 Nos (g) Circuit plate 30 KVA- 400 KVA - 01 Nos (h) Pulse transformer of cap 30 KVA -400 KVA - 01 Nos (i) Rewinding for copper coil -25 Kg (j) Shifting of stablizer from AOR of AGE Water supply to workshop (Tro/ Fro) (f) Items like carbon bush, push buttons auto/manual/micro press switch, indicator lamps, etc
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Supply and fixing the nipple brass nozzle of inlet size 15mm to 25mm for water fountain and outlet as per sample including removal of existing unsv one all as specified and directed by Engr-in-Charge.
Supply and fixing black flexible rubber Tyre coupling as per sample TC 14,TC 15, TC 16, TC 17, etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing flexible rubber star coupling as per sample complete all as specified and directed by Engineer-in-Charge.
Excavator for any type of work as per site requirement like surface excavation, leveling of uneven surface, cleaning of vegetation, removing of solids to clean surface, etc complete all as specified and directed by Engineer-in-Charge.
Supply,laying, jointing & testing of PVC PP-R pipe having outer dia 40mm of pressure rating PN 16 /SDR 7.4 in three layer with all fittings laid in trenches complete all as specified and directed by Engineer-in-Charge.
S&F PVC PP-R Ball valves (brass insert) of size 40mm complete all as specified and directed by Engr-in-charge.
S&F in replacement of pop-up sprinklers having radius throw 20 meters and flow minimum 1.2 LPS at an operative pressure 4-6 kg/sqcm. The sprinkler shall be impact driven rotary with provision for adjusting at any degree of rotating having 01 inlet 20 mm pop up stoke, self flushing with pop-up sheild made of virgin grade engineering, plastic body, sprinkler shall be non corrodible, heavy duty complete all as specified and directed by Engineer-in-Charge.
Material and labour for any type of welding at site in any shape including surface preparation and all necessary T&P required for welding at site with electric supply through generator set and welding at site including testing of joints after completion of the welding,complete all as specified and directed by Engr-in-charge.
Supply, install, testing and commissioning of wire mesh cable tray hot dip galvanised type of size of 105 mm height X 300 mm width, 3 meter length (straight/L shape) as per EN 12329 and IEC 61537 with wire diameter of 3.5 to 5.9 mm and having SST of 550 Hrs tested, having E30/E90 certification, with following specification all as per directed by engr in charge. i) C416/RCSN/R35 (wall/celling/ground mounting supports) every after 1 meter distance. ii) Kitaster coupler (Jointing tray) 5 sets per joint. iii) Down rod of 1 meter length each. iv) Nuts 3 nos for each rod. v) COUPFIL(Cutter) 01 No. vi) L supports for wall with all accessories such as nut, bolt, washers etc. Note:- a) Shifting of all existing cables any type any size, Removing connections of these cables and refixing at its original position through cable trays in a proper manner all as directed by engr in charge is included in the quoted rates. b) All major and minor spares are required in laying of cables and fixing of cable trays which are not mention above are included in the quoted rates. c) All meterial such as cement, concerete, tiles etc to make wall/roof /ground in its original shape after fixing of cable trays are included in the quoted rates.
Supply only in replacement leaf skimmer having upto 1.5mtr long adjustable handle all as per directed by engr in charge.
Supply only in replacement wire brush steel handle stainless steel wire all as per directed by engr in charge.
M&L for Tank level gauge range 0-3 mtr with marking at each 0.1 mtr all as per directed by engr in charge.
Supply only nylon trimmer line of size 3mm to 3.5mm complete all as per directed by engr-in-charge.
Supply & fix in replacement Loss of Head (LoH) for Rapid sand filter cap 40,000 Glns/hours, monitoring the Level in High Pressure and low pressure side of the gravity filter / Traveling water screen. The Loss of Head arrangement shall have following feature complete all as specified and directed by Engineer-in-Charge.- (a) Measuring Differential level in Filter Beds. (b) Housing : Cast Aluminium, Powder Coated. 198*170* 99 mm (c) Mounting : Wall Mounting (d) Power Supply : 230 V AC, 50 Hz (e) Power Consumption : 4 VA (approximately) (f) Adjustment Range : Span : Min 10% of Electrode Length, Max 80% of Electrode Length & Zero : Max 80% of Electrode Length (g) Alarm : A relay C/O rated 6 Amps 230 V, non-inductive load adjustable throughout range (h) Current output : 4-20mA DC non isolated, max. load resistance 600 Ohms, corresponding to differential level (j) Accuracy : ±4% of Electrode Length (h) Supplied with Rate of Flow (RoF) in a common CA Housing with IP-55 Protection Note: Material and labour charges & cables for installation/connection of setup & taking down old setup shall be deemed included in the quoted rates.
Supply & fix in replacement Digital Water Flow Meter for Rapid sand filter cap 40000 GPH, Line Size: 8 INCH, Nabl Traceable. Display: Graphical Display 64*128, Accuracy: Up to 0.5% accuracy (Standard 1% Accuracy), Resolution: 5 digits Flowrate, Totalizer: 10 digits Totalizer, Application: Water filteration Plant, Flowrate: 5Digit and Auto Adjust With Line Size, Velocity: 5Digit Velocity 0.000 M/s to 10.000 M/s, Flow Detection: Alarm, Power Supply: 90 - 260 VAC 50/60Hz,24VDC,12VDC, Retransmission: 4-20mA (Opto & Galvanic Isolated) complete all as specified and directed by Engr-in-Charge. Note: Material and labour charges & cables for installation/connection of setup & taking down old setup shall be deemed included in the quoted rates.
M&L for replacement of flow controller arrangement suitable for capacity 1 x 40,000 Glns/hours output discharge including necessary fixing arrangement as required at site for smooth functioning of the filtration system complete all as specified and directed by Engr-in-Charge. Note: Material and labour charges for installation/connection of setup & taking down old setup shall be deemed included in the quoted rates.
BARU ENTERPRISES (BID ID -3304960)
M/s Sahib Construction and engineers (BID ID -3311568)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .