Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹24.8 L+₹7,169 (0.29%)Rejected-Finance | L2 | Rejected-Finance Being not the lowest | |
| 3 | L3₹24.8 L+₹7,448 (0.30%)Rejected-Finance | L3 | Rejected-Finance Being not the lowest | |
| 4 | L4₹25.8 L+₹1.1 L (4.62%)Rejected-Finance | L4 | Rejected-Finance Being not the lowest | |
| 5 | L5₹26.3 L+₹1.6 L (6.30%)Rejected-Finance | L5 | Rejected-Finance Being not the lowest |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
29 Sept 2021, 6:00 pmClosed
GE Minniebay
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIRS TO CULVERT, FENCING, RETAINING WALL, GATE AND OTHER MISC B/R ITEMS UNDER AGE B/R I AT GE MINNIEBAY, PORT BLAIR
2021_MES_471900_2
8980/E8
Open Tender
Civil Works
Item Rate
300 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹54,000
Yes
2 Nov 2021
2 Sept 2021
7 Oct 2021
2 Sept 2021
29 Sept 2021
16 Sept 2021
Amount
Demolition of cement concrete (reinforcement) of any description and in any position not otherwise specifically provided for
Demolition of precast concrete block walling built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed..
M&L for Providing, Precast RCC type B1 1:2:4 using 20mm graded stone aggregate in covers slabs over drains including necessary formwork etc , set in cement mortar 1:4 all as specified and directed. Note: Reinforcement shall be measured & paid separately
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:4) all as specified
M&L for rendering 15 mm thick in CM (1:4) on external surfaces of walls of block masonry finished even & smooth without using extra cement complete all as specified and as directed
Dismantling posts or struts (steel or RCC) embedded in concrete, any section, including taking out embedded portion and making good the disturbed surface complete all as specified and as directed.
Excavation in post holes (or similar holes) each n. exc 0.5 Cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc exc 25 cm watering and removing surplus soil to a distance n exc 50 m and making good surface as in soft/loose soil all as specified and directed
M&L for cement concrete Type C2 1:3:6 using 40 mm graded stone aggregate as in foundation filling and mass concrete all as specified and directed
S&F in position angle iron for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
S&F GI chain link fencing of 3.50mm dia with PVC coated 50mm x 50mm to any type of standards, rails, straining bolts etc including binding with wire including taking of existing GI fencing complete all as specified and as directed.
M&L for 10 mm dia MS round bars cut to length bent to shape required etc. (to be used for stiffness to chain link) fixed indepdently to the angle iron post as directed by Engr-In-Charge. (Conforming to Fe 410-W or (Gde E-250) quality A or Fe 290 (Gde E-165) complete all as specified and as directed.
S&F MS screw bolts (machine made 12 mm dia. Shank) with hexagonal or square heads at one end and screwed at another end, each screwed end to be fitted with washer and one hexagonal or square nut, exc. 5cm n. exc 10 cm in length complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of Red oxide, zinc primer including preparation of new steel/iron surface of any description over 10 cm in width or girth complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of Red oxide, zinc primer including preparation of new steel/iron surface of any description n exc 10 cm in width or girth complete all as specified and as directed.
S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe 290 (Gde E-165) complete all as specified and as directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and throw away in low laying area etc complete all as specified and directed.
M & L 75mm thick PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in floors etc complete with finishing cement concrete surface even and smooth without using extra cement
M&L for forming 12mm thick, 100mm depth Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A' complete all as specified and as directed.
M&L for forming contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound, grade 'A' complete all as specified and as directed.
M & L for 75mm thick PCC 1:3:6, type C1 using 40 mm graded stone aggregate as in sub base etc complete.
M & L for 40mm thick PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in sub base etc complete.
M & L for Vetrified Chequered cement concrete tiles 30cm x 30cm x 8/10 mm thick, set, jointed and pointed in near cement slurry in floors With grey cement and pigments and including screed bed 15mm thick CM 1:4 complete all as specified and as directed.
M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade, With grey cement and pigments complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M & L for providing cement concrete 1:3:6, type B1 using 40 mm graded stone aggregate as in surface channel and drains etc complete.
M & L for extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and as directed..
S&F ìn stainless steel tubing of any diameter or square or rectangular in shape, thickness not less than 1.6mm of grade AISI-316 type aesthetic anticorossive in nature as in framed work/post/fencing work/railling/designer work, purposily made doom and base welded with tubing where required including cutting, bending, welding, grinding, buffing and bright polishing the welded joints and adjacent areas and fixing in any type of location complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for 18/20mm thick Granite (of any type) tiles machine cut in skirting/dado laid over 10mm thick 1:4 cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing of type complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
Demolition and breaking up drain pipes of size any dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar including bends, tees, elbow etc laid in trenches complete all as specified and as directed
Dismantling of cast iron or reinforced concrete / PVC (SWR) pipes of size 150mm dia fixed with clamps and including tees, bends, elbow complee all as specified and as directed
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F 75mm dia PVC (SWR) bends any radius complete all as specified and as directed.
S&F 75mm dia PVC (SWR) bends any radius, provided with access door complete all as specified and as directed.
S&F 75mm dia PVC (SWR), junction single, (Single T) equal or unequal, provided with access door complete all as specified and as directed.
S&F 110mm dia PVC (SWR) bends any radius complete all as specified and as directed.
S&F 110mm dia PVC (SWR) bends any radius, provided with access door complete all as specified and as directed.
S&F 75mm dia PVC (SWR), junction single, (Single T) equal or unequal, provided with access door complete all as specified and as directed.
S&F 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
S&F 150mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
M&L for concrete bed (1:3:6) Type C1 to drain pipes including packing under and haunching against the sides of pipes after are laid and tested in 150mm dia pipe complete all as specified and as directed..
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for taking out carefully the cover slab of each manhole of any size depth and removing the scum/sludge to distance exc 250 m and n exc 500 m and cleaning with fresh water placing the cover slab in positon all as diercted
M&L for cleaning of slugdes/silt from floor trap including roding CI pipe from nahini trap/ floor tarp to gully trap etc in position including removing of rubbish/sludge to a distance exceeding 250 m not exceeding 500 m all as specified and directed
M&L for Claeaning of blockage of EWC, IWC including roding CI pipe after opening the oval exceess door of CI bend CI brach piece (T) etc upto first manhole and placing the exiting oval excess door in original position incluidng removing the rubbish/sludge to a distance exc 250 m n exc 500m all as specified
M&L for Cleaning carefully (with fresh water) the blockage of 150mm dia Pipe any type in between man holes and passing rubber ball through line to ensure all blockage perfectly clear all as directed by Engineer-in-Charege.
M&L for Cleaning carefully (with fresh water) the blockage of 75mm dia CI/PVC Pipe on wall & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M all as directed by Engineer-in-Charege.
M&L for cleaning carefully (with fresh water) the blockage of 100/110mm dia CI/PVC Pipe on wall & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M all as directed by Engineer-in-Charge.
M&L for De-watering & cleaning of septic tanks, manhole, sludge chamber etc. by pumping out sludge water manually or mechincally including cleaning of shrubs/ bushes vegetation 2.50m around the septic tank & the like and makng good to usable condition of the same complete all as specified and directed by Eng-in-Charge complete all as specified
M & L for preparation of new plastered or previously untreated wall surfaces including scraping, rubbing and washing etc and applying two coats of acrylic emulsion based premium quality exterior antifungal paint (chequired pattern) over a coat of primer in chequrred pattern all as directed by the Engineer-in-charge and as per manufacturers instructions
AR CONSTRUCTIONS
M/S TANISHA ENTERPRISES
RADHA GOVIND CONSTRUCTION
V CHINNA DURAI
Allied Trading Company
M/s J. M. Enterprises
AMR TRADERS
T.M.RAMANATHAN AND SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .