Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC | L1 | Accepted-AOC AOC SINCE L1 | |
| 2 | L2₹22.7 L+₹5.9 L (35.5%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L2 | Rejected-Finance REJECTED SINCE NOT L1 | |
| 3 | L3₹30.4 L+₹13.6 L (81.4%)Rejected-Finance | L3 | Rejected-Finance REJECTED SINCE NOT L1 | |
| 4 | L4₹31.2 L+₹14.4 L (86.2%)Rejected-Finance | L4 | Rejected-Finance REJECTED SINCE NOT L1 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
9 Nov 2021, 6:00 pmClosed
CWE AMRITSAR
HQ CWE AMRITSAR OLD AMRITSAR CANTT
SPL REPAIR / RENOVATION OF INTERNAL WIRING INCLUDING FITTING AND FIXTURES OF KENDRA VIDYALAYA NO-01 AT OLD AMRITSAR CANTT
2021_MES_480295_1
CWE/ASR-35/2021-22
Open Tender
Civil Works
Item Rate
180 days
AMRITSAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AMRITSAR
₹72,000
Yes
3 Jan 2022
7 Oct 2021
16 Nov 2021
7 Oct 2021
9 Nov 2021
28 Oct 2021
Amount
Point wiring complete with 1.5 Sq mm (nominal area)FR PVC insulated un-sheathed and stranded copper conductor cable ISI marked (Make : L&T / Finolex / Havells / RR Kabel) and including PVC concealed conduit ISI marked (Make : Plaza / Anchor / Kalinga) of size 20 mm dia and 1.5 mm wall thickness and conduit fittings including FR PVC insulated unsheathed 1.5 Sqmm copper earth wire (Make : L&T / Finolex / Havells / RR Kabel) to common earth and connecting to earth dolly and Metal Flush box, cover plate with frame of suitable size for fixing modular switches/sockets/fan regulator etc complete all as specified for the following (Note : Cost of Metal boxes and modular accessories like cover plates will be included in quoated rate.)
Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push.
One socket outet point 5 amps on the same board.
One socket outet point 5 amps on the independent board.
All as per item nNo 1.00 but 2 way switch wiring
All as Ser item 1 here in before but with 2.5 sq mm wire and earth wire of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet. Note : Point wiring for power point will not be mixed with light/fan point circuit or not in the same conduit pipe.
All as Ser item 1 here in before but with 4 sq mm wire and earth wire of 4 sq mm for 3 Pin 15 Amp modular type socket outlet. Note : Point wiring for power point will not be mixed with light/fan point circuit or not in the same conduit pipe.
Supply and Fixing Modular switch 6 Amp 1 way 1 module size complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing Modular switch 16 Amp 1 way with indicator 1 module size complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing Modular socket shuttered 6 Amp 2/3 pin combined 2 module size complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing Modular socket 16Amp multipurpose type 2 module size complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing Modular Fan regulator step type 120 watts 2 Module size complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing Modular blank plate 1 Module size complete all as specified and as directed by Engr-in-Charge.
S&F bell push, Module type, single pole 5 amps complete all as specified and directed.
Supply and fixing of single phase call bell ‘DING DONG’, AC 230 volts single pole fixed over and including pressed steel sunk box of size 175 X 100 mm duly covered with 3 mm thick bakelite sheet complete all as specified and directed. Make : Anchor/Legrand/Plaza or equivalent
S & F lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed.
Supply and Fixing Ceiling rose, surface bakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size ,complete ,all as specified.
S&F Modular two way swtich including connection complete all as specified and directed.
S&F Modular swtich and socket (starter) 25 Amp cap for AC complete all as specified and directed.
S & F in repair MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. Make polycab havells or equivlant make
S & F in repair MCB double pole, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed. Make polycab havells or equivlant make
S&F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. . (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
S&F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
S&F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 16 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
S&F of Blanking plate of plastic (suitable for distribution board) complete all as specified and directed by Engineer-in-Charge.
S & F in repair wall /ceiling mounting LED 18 Watt high quality tube light fitting complete with all acessories 1x18 Watt LED , suitable for domestic application, 240 Volts, 50 Hz, including one tube rod and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete Make Havell's/Wipro/CG
S & F in repair wall /ceiling mounting LED 18 Watt high quality tube light fitting complete with all acessories 2x18 Watt LED , suitable for domestic application, 240 Volts, 50 Hz, including fitted two rod and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete Make Havell's/Wipro/CG
S&F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
S & F MCB C curve , 4 pole 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type 415 volts complete all as specified and directed. Make polycab havells or equivlant make
M&L for earthing complete with galvanised steel earth plate electrode 600mmx600mmx6.3 mm thick burried in ground vertically to a depth not less than 2.25 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15 cm thick layers of common salt and charcoal dust starting FRLSom ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth lead of size 4 mm by means of galvnised nuts, bolts and washers. GI wire of 4 mm dia laid in 15 mm dia light grade GI pipe as protection FRLSom top of the plate up to test point (cost of protection pipe up to 7.5 meters FRLSom earth electrode will be included in the rates quoted by the contractor) with following:- (a) test point of GI.
(a) Watering pipe GI light grade 20mm dia FRLSom top of the earth electrode up to MS funnel with brass wire mesh embeded in floor of PCC earth pit. (GI watering pipe should properly tightned on GI plate & Funnel and embeded in PCC floor of earth pit)
(b) PCC earth pit 30cmx30cmx30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 1 Nos MS handles suitable for carrying of pit cover.
(c) Angle Iron FRLSame Made of 40x40x4 mm size angle iron for holding earth pit cover.
Note :- The cost of excavation, earth work, watering pipe, metal test point, MS funnel with brass wire mesh and RCC pit with pit cover have already been included in the rates. No extra cost shall be paid to the contractor against these items.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, sockets, lamp holders, brackets, bulk head fittings, tube light fittings etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and white / colour wash etc. complete all as specified and directed.
M & L for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with stranded copper conductor 6 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 6 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.NOTE: 2 single core 6 sqmm and one 4 sqmm cable and PVC conduit shall be measured as one unit.
S&F MCCB Incomer distribution board double door vertical type made out of CRCA MS sheet surface with insulated material like polyester or with epoxy powder coating surface mounting TPN 4 way, 415 volts with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB and IP 43 - IK 09 protection with and incl 100 amp 36 kA 4 pole MCCB with thermal - magnetic setting and Icu = Ics = 100% (Make of MCCB : Legrand Lexic DPX /Schinder Elect Compact CVS/L&T DU 100) complete all as specified. Make : Legrand Lexic/ Hager / Schneider Merlin Gerin Multi-9 . (Note : The cost of removing old wooden/steel box etc and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
S&F over load voltage release 230 volts to 280 volts AC including connection complete all as specfieid and directed by Engr-in -Charge Make Hager
Supply and fix in replacement of security light fitting LED 45 Watt aluminum pressure dia cast housing with touched glass cover IP-66 protection Including suitable size and accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal including taking down old CFL security light fitting all as specified and as directed of Make Wipro/Philips/Havells
S& F GI bracket light grade GI Pipe 1.2 mtr Length for fixing of street light fitting 36/40 Watt including connection all as specified and directed.
M & L for sub main wiring with 1100 volt grade four single core PVC insulated and unsheathed cable with stranded copper conductor 10 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 6 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.NOTE: 4 run of 10 sqmm and 3 run 6 sqmm and one run PVC conduit shall be measured as one unit.
S&F Exhaust fan 300 mm sweep heavy duty metal body including cutting of wall /window/lowers and fixing arrangement complete all as specified and directed. Make Havells/Bajaja/CG
S&F wall mounting fan 450 mm sweep including connection and fixing arrangement complete all as specified and directed Make Havells/Bajaja/CG
S&F ceiling fan 1200 mm sweep complete with including fitting and fixture as per site requirement and complete acessories 230 volts single phase 50 Hz AC supply and connecting up with and including two core PVC insulated PVC Shethed copper conductor all as specified and directed Make Havells/CG/Bajaj
Taking down ceiling fan of 1200/1400 mm sweep including dismantling blades and material and labour for gressing oiling and spray painting of ceiling fan of any make/model/size complete including fan body, blade, canopies, down rod etc with one coat of synthetic enamel spray paint of white colour after cleaning all dust/oil and greasy spots including filling cavities using filler material and refixing the same to its original position making electric connecting complete all as specified and directed . Note The compressor and spray machine shall be arranged/bourhgt by the contractor and no extra cost shall be paid to the contractor.
Supply and fix MCB TPN 63 Amp 4 pole 415 volts including connection all as specified and as directed
UNITED ENGINEERING CORPORATION
GEE EMM ASSOCIATES
ESS KAY BUILDER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .