Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹22.8 L+₹28,167.27 (1.25%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 3 | L3₹23.5 L+₹94,748.89 (4.21%)Rejected-AOC | L3 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| Sl No | Description | Qty | Unit | Green Ray Technologies L3 | PSK Enterprises L2 | m/s SRI VALLI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Material and labour for Checking,Cleaning,servicing and overhauling of existing APFC Panels of any rating complete with PFC Controller, MCCB, MCB's, Contactors, relays and Busbar / cable connections of any rating / size with CRC spray including tightening of connections of power cables / control cable, bus bar, PFC Controller,capacitors and allied item connections including replacement of burnt Copper / Aluminium lugs all as per site requirements complete all as specified and directed.
Note for Item 1 :-
(i) The Major spares like MCCB/MCB/capacitor etc shall be measured and paid separately under relevant schedule of item.
(ii) Quoted rate deemed to include labour cost for servicing/ maintenance.
(iii) The quoted rate includes S&F necessary minor spare part/accessories like control wire, fuse, lugs as required for replacement of unserviceable items.
(iv) The quoted rate includes consumables like CRC spray and hardware like screws, bolts and nuts etc. | 9 | Each Job | 8,000 ₹72,000 | 7,100 ₹63,900 | 6,300 ₹56,700 Lowest |
| 2.00 | Taking down existing defective APFC control relay from the panel and replace with new 6 stage APFC relay with CT input and including S&F CT of appropriate rating including necessary wiring and wiring materials complete all as specified and as directed. | 2 | Each | 8,000 ₹16,000 | 8,000 ₹16,000 | 7,200 ₹14,400 Lowest |
| 3.00 | All as per item No-2 here-in-before but for 8 stage APFC relay with CT input and including S&F CT of appropriate rating complete all as specified and directed. | 2 | Each | 9,200 ₹18,400 | 8,000 ₹16,000 Lowest | 8,100 ₹16,200 |
| 4.00 | All as per item No-2 here-in-before but for 12 stage APFC relay with CT input and including S & F CT of appropriate rating Complete all as specified and directed. | 1 | Each | 9,850 ₹9,850 | 9,800 ₹9,800 Lowest | 9,900 ₹9,900 |
| 5.00 | Taking down existing defective panel board indication lamp (R/Y/B/G colour) from the panel and replacing with new LED indicator lamp complete all as specified and as directed . | 12 | Each | 200 ₹2,400 | 260 ₹3,120 | 180 ₹2,160 Lowest |
| 6.00 | Taking down existing defective VAF meter from the panel board and replace with new 3 phase VAF meter,class1, with LED display,for showing voltage, Amps, frequency including necessary wiring and wiring materials complete all as specified and as directed. | 3 | Each | 2,100 ₹6,300 Lowest | 3,140 ₹9,420 | 2,700 ₹8,100 |
| 7.00 | Taking down existing defective/unserviceable capacitor from the panel and replace with new heavy duty, aluminium casing,capacitor 2KVAR including necessary wiring and wiring materials complete all as specified and as directed. | 3 | Each | 3,500 ₹10,500 Lowest | 4,400 ₹13,200 | 4,500 ₹13,500 |
| 8.00 | All as per item No-7 here-in-before but for capacitor 5KVAR complete all as specified and as directed. | 3 | Each | 5,500 ₹16,500 Lowest | 7,100 ₹21,300 | 7,200 ₹21,600 |
| 9.00 | All as per item No-7 here-in-before but for capacitor 10KVAR complete all as specified and as directed. | 3 | Each | 8,500 ₹25,500 Lowest | 8,900 ₹26,700 | 9,900 ₹29,700 |
| 10.00 | All as per item No-7 here-in-before but for capacitor 20KVAR complete all as specified and as directed. | 3 | Each | 10,850 ₹32,550 Lowest | 12,500 ₹37,500 | 12,600 ₹37,800 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
31 Aug 2026, 6:00 pmClosed
Garrison Engineer (M) NAS Arakkonam
Garrison Engineer (M) NAS Arakkonam 631006
REPAIRS OVERHAULING SERVICING WORKS TO SERVO VOLTAGE STABILIZERS INCLUDING REPLACEMENT OF UNSERVICEABLE COMPONENTS ACCESSORIES OF LT PANEL FEEDER PILLAR BOXES AND CONNECTED ITEMS AT VARIOUS SUBSTATIONS AND LT ACB S SWITCH GEARS IN E M INSTALLATION
2026_MES_782443_1
8612E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (M) NAS Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer (M) NAS Arakkonam
₹50,000
Yes
25 Sept 2026
3 Aug 2026
2 Sept 2026
3 Aug 2026
31 Aug 2026
17 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for Checking,Cleaning,servicing and overhauling of existing APFC Panels of any rating complete with PFC Controller, MCCB, MCB's, Contactors, relays and Busbar / cable connections of any rating / size with CRC spray including tightening of connections of power cables / control cable, bus bar, PFC Controller,capacitors and allied item connections including replacement of burnt Copper / Aluminium lugs all as per site requirements complete all as specified and directed.
Note for Item 1 :-
(i) The Major spares like MCCB/MCB/capacitor etc shall be measured and paid separately under relevant schedule of item.
(ii) Quoted rate deemed to include labour cost for servicing/ maintenance.
(iii) The quoted rate includes S&F necessary minor spare part/accessories like control wire, fuse, lugs as required for replacement of unserviceable items.
(iv) The quoted rate includes consumables like CRC spray and hardware like screws, bolts and nuts etc. | 9 | Each Job | - | - |
| 2 | Taking down existing defective APFC control relay from the panel and replace with new 6 stage APFC relay with CT input and including S&F CT of appropriate rating including necessary wiring and wiring materials complete all as specified and as directed. | 2 | Each | - | - |
| 3 | All as per item No-2 here-in-before but for 8 stage APFC relay with CT input and including S&F CT of appropriate rating complete all as specified and directed. | 2 | Each | - | - |
| 4 | All as per item No-2 here-in-before but for 12 stage APFC relay with CT input and including S & F CT of appropriate rating Complete all as specified and directed. | 1 | Each | - | - |
| 5 | Taking down existing defective panel board indication lamp (R/Y/B/G colour) from the panel and replacing with new LED indicator lamp complete all as specified and as directed . | 12 | Each | - | - |
| 6 | Taking down existing defective VAF meter from the panel board and replace with new 3 phase VAF meter,class1, with LED display,for showing voltage, Amps, frequency including necessary wiring and wiring materials complete all as specified and as directed. | 3 | Each | - | - |
| 7 | Taking down existing defective/unserviceable capacitor from the panel and replace with new heavy duty, aluminium casing,capacitor 2KVAR including necessary wiring and wiring materials complete all as specified and as directed. | 3 | Each | - | - |
| 8 | All as per item No-7 here-in-before but for capacitor 5KVAR complete all as specified and as directed. | 3 | Each | - | - |
| 9 | All as per item No-7 here-in-before but for capacitor 10KVAR complete all as specified and as directed. | 3 | Each | - | - |
| 10 | All as per item No-7 here-in-before but for capacitor 20KVAR complete all as specified and as directed. | 3 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
NIT8612.pdf
Additional Documents • 0.71 MB
BOQ_876602.xls
BOQ • 0.34 MB
TenderDocument8612.pdf
Tender Documents • 1.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .