Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Nov 2021, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR C/O 56 APO
SPECIAL REPAIR TO PERIMETER SECURITY LIGHT FROM ADS POST TO CHENAB GATE AND PROVN OF 01 X SPLIT AC OF 2.0 TON CAPACITY FOR SAND MODEL ROOM AT BLDG NO P-17 UNDER AOR OF AGE E/M UNDER GE (SOUTH) AKHNOOR
2021_MES_480612_1
GES/AKH-44/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS E AND ABOVE AND CATEGORY b(i)
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹40,000
22 Jan 2022
8 Oct 2021
5 Nov 2021
8 Oct 2021
3 Nov 2021
13 Oct 2021
Amount
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for foundations/ laying of cables/pipes, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and not exceeding 3.0 mtr in depth and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Supply, erecting and fixing in replacement of old pole in true vertical position, steel tubular swaged pole (410 SP – 31), 09 meter long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint including taking down old damaged poles complete all as specified and directed.
Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc , complete all as specified and as directed by Engineer-In-Charge.
M&L for PCC type C-2 (1:3:6) with 40 mm gradded stone aggregate for coping of poles including necessary formwork complete all as specified and directed.
Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
S&F in replacement of SMC FRP junction Box, sliding door fixed to base by means of ssliding, pole monunting arrangeemnt, maint free, fire retardent, pilferage proof for entry the cable from side and bottom of size 340x160x90mm with aluminium bus bar for street lighting of 3 phasse/ 4 core complete all as specified and directed. Make: sintex GS-JB-3416 or equivelent in Havells/L&T.
S&F in replacement of 1100V Grade LT Aerial Bunched Cable of size 3x16 + 1x16 + 1x16 sq.mm (Phase Wire + Neutral Wire + Insulated Messenger Wire) having three Power Core & One insulated Messenger Core of stranded compacted circular Aluminium Black coloured XLPE insulated & Core identification by ridges, one, two and three & four respectively. Neutral Wire should be of stranded compacted Circular Aluminium Alloy Conductor conforming to IS 8130/1984, IS-398(Part-IV)/1979 and IS-14255/1995 with upto date amendments, if any, composition of phase wire, neutral wire and messeanger wire all shall conform to manufacturer instructions subject to compliance with Electricty manual /Indian Electricity Act -2003, and there by changes in the size of messeanger and neutral wire, nothing shall be admissible on this ground, including necessary connecting accessories like Anchor Clamps (3 Bolt and 2 Bolt Type), Eye hook with Suspension Clamp Assembly, PCC Pole Clamp, Insulation Piercing Connectors with cover or P.G.Connectors with insulation cover,Water Proof pre-insulated Hexagonal Compression Connectors & Lugs etc , complete all as specified and as directed by Engr-in-Charge. Make: Havells/ Poycab/ Finolex/ Gloster Cables Ltd/KEI.
S&F in replacement of LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in surge protection device, including LED lamps of 60 Watt and connecting up with twin core twisted flexible copper conductor cable with suitable size,, including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified. Make: Havells cat part No- Endura Pearl Plus SL60WLED757SASYTOPC/ Philips ordering code No- 910925865969 (Product Code- 871869632029700)/ Wipro cat part No- LR02-671-XXX-57-G2.
Supply and install and commissioning of hi wall split AIR CONDITIONER units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum BEE 5 star rating of capacity as shown of size 2.0 TR incl necessary fitting and fixture and testing after completion all as per manufacurer's instructions, complete all as specified and as directed by Engineer-In-Charge. Make: Voltas/ Carrier/ Blue Star/ Daiken/ Hitachi.
Voltage stabilizer for automatic operations, copper wounded, single phase, naturally air cooled, indoor type with copper wound, , working voltage range (input), 170 Volts to 270 Volts, with output voltage stabilizer at 230V current capacity upto 12 Amps, 5.0 KVA capacity, with accuracy of ±2.50%, suitable for air conditioner of 2.0TR capacity including making necessary connection, complete all as specified and as directed by Engineer-In-Charge. Make: AE/ ElectricField/ Andrew Yule / Godrej.
Sheet metal enclosures for Single Pole and Neutral distribution boxes with single door glazed for and including incorporating MCBs SPN-30 Amp-01 No, IP-43, 2-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
Dismantling of rusted and existing cross arms, angle iron , clamps, nut washers etc complete all as specified and as directed by Engineer-In-Charge.
Amount of Schedule of credit of for Rs 1,43,320.00 shall be deducted from quoted amount.
Usha Engineering Co.
M/s Rajesh Kumar Contractor
Jiwan Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .