Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical All Terms and Conditions Full Fill by Contractor |
| 2 | Accepted-Technical | Accepted-Technical All Terms and Conditions Full Fill by Contractor |
| 3 | Accepted-Technical 414 SECTOR 3 SHASTRI NAGAR ROAD SHASTRI NAGAR MEERUT UTTAR PRADESH 250004 | MEERUT | UTTAR PRADESH | 250004 | Accepted-Technical All Terms and Conditions Full Fill by Contractor |
Tender Value
₹34.4 L
EMD Value
₹3.4 L
Closing Date
12 May 2026, 3:00 pmClosed
Executive officer
Nagar palika parishad, Muzaffarnagar
Supply and assembly of Facada Light At Shiv Chowk
2026_DOLBU_1139970_1
183/sa.pra./2026-27 Dt 21-04-2026
Open Tender
Street Lighting
Percentage
90 days
work
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,124
Nagar palika parishad, Muzaffarnagar
₹3.4 L
20 May 2026
22 Apr 2026
12 May 2026
22 Apr 2026
12 May 2026
22 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of RGBW surface mounted Narrow / Medium beam linear wall Grazer luminaire (1000 mm) suitable for outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per design requirement. Power consumption should be 24W+ 10% at steady state full intensity, Luminaire luminous flux range of 800- 1000 Lm. Power factor of complete luminaire 0.90, at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. Luminaire should be compatible to DMX512 control protocol. The luminaire should have powder coating extruded aluminium housing. Ingress Protection IP 66 and above. Impact resistance level IK 07. Operating Temperature: -10°C to +50°C, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separate , Should have its Inhouse NABL Accredited Testing Lab with in its own Manufacturing Unit, all technical Parameters should comply IS 10332 Standards | - | Nos | - | - |
| 2 | Supply of Dynamic addressable RGB Neon Flex, product should be IP66 protected.Wattage:-12-15 W per meter, input Voltage : DC24V, Light Angle :'120-180',Electrical Grade : Class lll, Protection Grade IP66. Non integral DMX Decoder included. | - | Mtr | - | - |
| 3 | Supply of RGBW surface mounted Narrow / Medium beam linear wall Grazer luminaire (300 mm) suitable for outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per design requirement. Power consumption should be 12W+ 10% at steady state full intensity, Luminaire luminous flux range of 400- 600 Lm. Power factor of complete luminaire 0.90, at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. Luminaire should be compatible to DMX512 control protocol. The luminaire should have powder coating extruded aluminium housing. Ingress Protection IP 66 and above. Impact resistance level IK 07. Operating Temperature: -10°C to +50°C, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separate , Should have its Inhouse NABL Accredited Testing Lab with in its own Manufacturing Unit, all technical Parameters should comply IS 10332 Standards | - | Nos | - | - |
| 4 | Supply of RGBW surface mounted Narrow beam Architectural Flood luminaire suitable for outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per design requirement. Power consumption should be 60W+ 10% at steady state full intensity, Luminaire luminous flux range of 1800- 2000 Lm. Power factor of complete luminaire 0.90, at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. Luminaire should be compatible to DMX512 control protocol. The luminaire should have powder coating extruded aluminium housing. Ingress Protection IP 66 and above. Impact resistance level IK 07. Operating Temperature: -10°C to +50°C, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separate , Should have its Inhouse NABL Accredited Testing Lab with in its own Manufacturing Unit, all technical Parameters should comply IS 10332 Standards | - | Nos | - | - |
| 5 | Supply of Monochrome warm white surface mounted various beam of Architectural Flood luminaire suitable for outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per design requirement. Power consumption should be 45W+ 10% at steady state full intensity, Luminaire luminous flux range of 4000- 4500 Lm. Power factor of complete luminaire 0.90, at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. The luminaire should have powder coating extruded aluminium housing. Ingress Protection IP 66 and above. Impact resistance level IK 07. Operating Temperature: -10°C to +50°C, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separate , Should have its Inhouse NABL Accredited Testing Lab with in its own Manufacturing Unit, all technical Parameters should comply IS 10332 Standards | - | Nos | - | - |
| 6 | Supply of DMX controller NICOLAUDIE make, Model no. SLESA-U-11, Input : 5-5.5V DC Output : DMX512 (1024 channels), with Clock & Calender Triggering, 4N output Ports, USB and Ethernet connectivity port for programming / control, and Power Supply included micro SD card. | - | No | - | - |
| 7 | Supply of DMX Splitter / Booster - Individual optical isolation per port. Housing types: Box. Min. 4 DMX Outputs per universe DMX line termination | - | No | - | - |
| 8 | Supply of DMX cable of (single pair) having one 22/24AWG pair stranded (7x30) tinned copper conductors, twisted pairs, overall Beldfoil shield (100% coverage) plus tinned copper braid, PVC jacket Cable. Beldon, Folcon, Hengle make or equivalent | - | Nos | - | - |
| 9 | Supply of water proof (IP 67 rating) Screw type Connector set for connecting DMX cables. | - | Nos | - | - |
| 10 | Supply of 25 mm dia. PVC conduit for DMX cable. | - | Mtr | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
BOQ_2128553.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .