Tender Value
₹9.7 Cr
EMD Value
₹19.4 L
Closing Date
21 Dec 2022, 9:00 amClosed
PARMOD KUMAR
EE PHE Division No. 2 Bhiwani
Designing, providing, fixing, commissioning and testing of online analyzer for turbidity and chlorine, auto switchover, Chlorine dry scrubber and auto shut off valve and all other works contingent thereto at various water works with comprehensive mai
2022_HRY_248413_1
20221FE04433 2F0C 444E AF2D 57D6C29FDBB0554PUH
Open Tender
Civil Works
530 days
MUNDHAL KALAN TIGRANA MANDHANA JATAI TALU
2 documents required · 2 mandatory
₹25,000
Yes
₹19.4 L
Yes
3 Jan 2023
2 Dec 2022
21 Dec 2022
2 Dec 2022
21 Dec 2022
2 Dec 2022
Amount
NS Item
Comprehensive maintenance of complete system under this dnit in all respect including replacement of any part and consumables including reagents of original make, general insurance of system, SIM data cost, network and cloud storage etc for 1st year
Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, general insurance of the system, SIM data cost, network and cloud storage etc for 2nd year
Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, general insurance of the system, SIM data cost, network and cloud storage etc for 3rd year
Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, general insurance of the system, SIM data cost, network and cloud storage etc for 4th year
Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, general insurance of the system, SIM data cost, network and cloud storage etc for 5th year
Designing, providing, fixing, testing and commissioning of AUTOMATIC SHUT OFF VALVE Automatic shut off valve shall be provided as safety device for use with chlorine (Cl2) gas cylinders. System includes: - Automatic shut off valve for safety in case of chlorine (Cl2) gas leakage. Operating Procedures: - The system will consist of electronically controlled precision actuators for automatic operation of chlorine (Cl2) gas cylinder valve in case of an emergency. The system shall be compatible with existing chlorine gas leak detectors installed at site and shall automatically operate the chlorine (Cl2) cylinder valve through the output signal from the leak detector in case of chlorine (Cl2) gas leakage. Technical Specification: - I. Performance Requirements: - 1. Installation on existing chlorine (Cl2) gas cylinders 2. Attached to valve body 3. “Clamp on system” allowing the actuator attachment and detachment from the valve body in seconds 4. Adjustable torque to fit any specific regulations and requirements 5. Valve closure in less than 30 seconds 6. Actuator minimum step angle: Upto 1° II. Operational Requirements: 1. Housed in an IP65-rated enclosure. 2. Compatible with chlorine (Cl2) gas leak detectors having any analog or digital output with provision for auto-calibration with the leak detector. 3. Has an actuator memory and control unit so that the system has real-time update of cylinder valve status. 4. Utilizes an electronic actuator with an independent driver for precision in valve operation. 5. Provides a variable closing torque of 10-20 ft-lb which can be manually adjusted. 6. Utilizes a chlorine resistant coating of Teflon/Xylan on the housing of the actuator to ensure protection of internal components of the actuator. 7. Utilizes a status light to indicate operating status. 8. Includes provision for manual operation of chlorine cylinder valve. 9. Includes an electronic switch for manual operation of the cylinder valve. 10.Includes capability to actively monitor all internal components and present diagnostics on the overall health of the system and time to next required maintenance. 11. Provides step-by-step, on-screen instructions for all routine maintenance activities. III. Environmental Requirements 1. Power Supply: 220 VAC 2. Degree of Protection: IP65 3. Closing Torque: 10-20 foot per pound 4. Operating temperature: 41 to 104 °F (5 to 50 °C) 5. Operating humidity: 0 to 95% non-condensing relative humidity Installation: - 1. Contractor/Agency will install the Emergency chlorine gas dry scrubber in strict accordance with the manufacturer’s instructions and recommendation. 2 . Contractor/Agency after installation will provide basic training for operation to the staff free of cost. 3. Contractor/Agency will use original spares for maintenance.
Designing, providing, fixing, testing and commissioning of ONLINE WATER QUALITY ANALYZER for testing of available chlorine and turbidity in water One No. continuous online monitoring of available chlorine and turbidity analyzer shall be provided for monitoring the water supply at delivery. System includes: - Online available chlorine and turbidity analyzer for continuous and online monitoring of drinking water. Operating Procedures: - 1. The method of measuring available chlorine will be colorimetric. Instrument chemistry will employ N, N-diethyl-p phenylenediamine (DPD) method. 2. The low range online turbidity-meter consisting of white light source and 360° x 90° detection system consisting of multiple light sensors with predictive diagnostics designed to monitor turbidity in a sample stream. Technical Specifications: - I. Performance Requirements for available chlorine: - 1. Measurement range: 0 to 10 mg/L (ppm) available chlorine 2. Accuracy: ± 5% of reading or ± 0.1 mg/L (ppm), whichever is greater from 0 to 5 mg/L (ppm) as Cl2 3. Resolution: 0.1 mg/L (ppm) 4. Repeatability: 5% of reading or 0.1 mg/L (ppm), whichever is greater 5. Configurable Cycle Time: 2.5 minutes to 10 minutes II. Performance Requirements for turbidity 1. Detection Limit: 0.1 NTU 2. Accuracy: ± 5% of reading ± 0.1 NTU from 0 to 5 NTU based on formazin primary standard at 25°C 3. Resolution: 0.1 NTU 4. Repeatability: 5% of reading or 0.1 NTU, whichever is greater based on formazin primary standard at 25°C 5. Configurable Cycle Time: 30 seconds to 10 minutes III. Operational Requirements: 1. Housed in an IP65-rated enclosure. 2. Capable of measuring available chlorine by indicator and buffer solutions. 3. Has an auto clean mechanism for cleaning of colorimetric measurement cell. 4. Has an proprietary mixer/inner activated mixer/mechanical mixer for mixing of reagents in the colorimetric measurement cell. 5. Measurements to be taken regularly and results are displayed on a controller display and web-enabled display in the range of 0 to 5 mg/L(ppm). 6. Utilizes electronically controlled motor drivers for precise input of water sample and reagents for colorimetric measurement cell. 7. Connects to a standard controller, which controls and provides power to the analyzer. 8. Performs a blank reference measurement check between analysis points to compensate for sample color, turbidity, and changes in light intensity due to voltage fluctuations or light source aging. 9. Operates with an LED light source. 10. Capable of operating unattended for 30 days between chemical reagent changes and measurement cell cleaning. 11. Utilizes a status light to indicate operating status. 12. Utilizes level indicator sensors in reagents to inform when reagent levels are low and in need of replacement. 13. Includes capability to actively monitor all internal components and present diagnostics on the overall health of the analyzer and time to next required maintenance. 14. Provides step-by step, on-screen instructions for all routine maintenance activities, including reagent changes, tubing changes, and cell cleanings. 15. Connects to a cloud-based standard controller and is capable of providing remote monitoring of measurement and instrument data on a web-enabled device. Auto-transmission of these data to an IT platform through Cellular (GSM, GPRS,4G/LTE,5G, NB-IoT), LoRa or other RF technology. IV. Environmental Requirements 1. Sample flow rate: 20 to 100 mL/minute through the analyzer 2. Operating voltage: 220 VAC 3. Sample temperature: 5 °C to 50 °C 4. Operating temperature: 0 °C to 50 °C 5. Operating humidity: 0 to 95% non-condensing relative humidity Installation: - 1. Contractor/Agency will install the analyzer in strict accordance with the manufacturer’s instructions and recommendation. 2. Contractor/Agency after installation will provide basic training for operation to the staff free of cost. 3. Contractor/Agency will use original spares for maintenance.
Designing, providing, fixing, testing and commissioning of ONLINE WATER QUALITY ANALYZER for testing of available chlorine and turbidity in water One No. continuous online monitoring of available chlorine and turbidity analyzer shall be provided for monitoring the water supply at delivery. System includes: - Online available chlorine and turbidity analyzer for continuous and online monitoring of drinking water. Operating Procedures: - 1. The method of measuring available chlorine will be colorimetric. Instrument chemistry will employ N, N-diethyl-p phenylenediamine (DPD) method. 2. The low range online turbidity-meter consisting of white light source and 360° x 90° detection system consisting of multiple light sensors with predictive diagnostics designed to monitor turbidity in a sample stream. Technical Specifications: - I. Performance Requirements for available chlorine: - 1. Measurement range: 0 to 10 mg/L (ppm) available chlorine 2. Accuracy: ± 5% of reading or ± 0.1 mg/L (ppm), whichever is greater from 0 to 5 mg/L (ppm) as Cl2 3. Resolution: 0.1 mg/L (ppm) 4. Repeatability: 5% of reading or 0.1 mg/L (ppm), whichever is greater 5. Configurable Cycle Time: 2.5 minutes to 10 minutes II. Performance Requirements for turbidity 1. Detection Limit: 0.1 NTU 2. Accuracy: ± 5% of reading ± 0.1 NTU from 0 to 5 NTU based on formazin primary standard at 25°C 3. Resolution: 0.1 NTU 4. Repeatability: 5% of reading or 0.1 NTU, whichever is greater based on formazin primary standard at 25°C 5. Configurable Cycle Time: 30 seconds to 10 minutes III. Operational Requirements: 1. Housed in an IP65-rated enclosure. 2. Capable of measuring available chlorine by indicator and buffer solutions. 3. Has an auto clean mechanism for cleaning of colorimetric measurement cell. 4. Has an proprietary mixer/inner activated mixer/mechanical mixer for mixing of reagents in the colorimetric measurement cell. 5. Measurements to be taken regularly and results are displayed on a controller display and web-enabled display in the range of 0 to 5 mg/L(ppm). 6. Utilizes electronically controlled motor drivers for precise input of water sample and reagents for colorimetric measurement cell. 7. Connects to a standard controller, which controls and provides power to the analyzer. 8. Performs a blank reference measurement check between analysis points to compensate for sample color, turbidity, and changes in light intensity due to voltage fluctuations or light source aging. 9. Operates with an LED light source. 10. Capable of operating unattended for 30 days between chemical reagent changes and measurement cell cleaning. 11. Utilizes a status light to indicate operating status. 12. Utilizes level indicator sensors in reagents to inform when reagent levels are low and in need of replacement. 13. Includes capability to actively monitor all internal components and present diagnostics on the overall health of the analyzer and time to next required maintenance. 14. Provides step-by step, on-screen instructions for all routine maintenance activities, including reagent changes, tubing changes, and cell cleanings. 15. Connects to a cloud-based standard controller and is capable of providing remote monitoring of measurement and instrument data on a web-enabled device. Auto-transmission of these data to an IT platform through Cellular (GSM, GPRS,4G/LTE,5G, NB-IoT), LoRa or other RF technology. IV. Environmental Requirements 1. Sample flow rate: 20 to 100 mL/minute through the analyzer 2. Operating voltage: 220 VAC 3. Sample temperature: 5 °C to 50 °C 4. Operating temperature: 0 °C to 50 °C 5. Operating humidity: 0 to 95% non-condensing relative humidity Installation: - 1. Contractor/Agency will install the analyzer in strict accordance with the manufacturer’s instructions and recommendation. 2. Contractor/Agency after installation will provide basic training for operation to the staff free of cost. 3. Contractor/Agency will use original spares for maintenance.
Designing, providing, fixing, testing and commissioning of VACUUM-OPERATED AUTOMATIC SWITCHOVER SYSTEM compatible with the existing gas chlorination system. One No. auto-switchover system including standby chlorinator for the existing one no. gas chlorinator shall be supplied for round the clock disinfection of filtered water. System includes: - Auto-switchover system with standby gas chlorinator having capacity upto 2000 gm/hr for continuous disinfection through chlorine (Cl2) in water consisting of: - (a) Auto-switchover module (b) Full vacuum chlorination system in all respect consisting of (i) Regulator (ii) Measuring Tube (iii) Ejector (iv) PF Tubing (v) Spanner Operating Procedures: - Vacuum operated automatic switchover system should be compatible with the existing gas chlorination system designed to automatically switch chlorine feed from an empty cylinder/faulty system to a full cylinder/standby system to ensure round-the-clock disinfection even when the system is unattended. Technical Specifications: - I. Auto-switchover module: - 1. Vacuum based auto-switchover module having two independent chlorination systems. 2. Auto switching of chlorination system on the signal output of vacuum sensors installed. II. Gas Chlorinator having capacity of 2000 gm/hr.: - 1. Vacuum Regulator: - (i) Constructed using fiberglass reinforced ABS(acrylonitrile-butadlene-styrene) -carbon black for high UV resistance. Fiberglass reinforced ABS – carbon black has excellent strength, mechanical crack resistance and dimensional stability. (ii) Main Regulator Diaphragm constructed using ECTFE (ethylene chlorotrifluoroethylene). (iii) Body bolts constructed using Titanium. Titanium has excellent resistance to chlorine gas and is completely unaffected by it. (iv) Loss Of Chlorine Supply indicator 2. Measuring Tube : - (i) Manual control of chlorine gas dosage through control of gas upto 20th part of maximum dose. (ii) Visible markings on the measuring tube for visual checking and setting of chlorine gas dosage being injected into water. (iii) Constructed using fiberglass reinforced ABS -carbon black for high UV resistance. Fiberglass reinforced ABS – carbon black has excellent strength, mechanical crack resistance and dimensional stability. (iv) Variable area precision Borosilicate glass tube with Pyrex glass indicating float with English and Metric graduations. 3. Ejector : - (i) Maximum Back Pressure Resistance of the ejector - 200 PSI (pound per square inch)/ 13.78 Kg/cm2. (ii) Dual check valve for High/Low Back Pressure. (iii) Constructed using fiberglass reinforced ABS - carbon black for high UV resistance. Fiberglass reinforced ABS – carbon black has excellent strength, mechanical crack resistance and dimensional stability. Environmental and Operational Requirements: 1. Operating voltage 220 VAC 2. Maximum Inlet Pressure of water: 200 PSI (pound per square inch)/ 13.78 Kg/cm2 3. Operating temperature: 0° C to 50° C 4. Operating humidity: 0 to 95% non-condensing relative humidity Installation: - 1. Contractor/Agency will install the auto-switchover system in strict accordance with the manufacturer’s instructions and recommendation. 2. Contractor/Agency after installation will provide basic training for operation to the staff free of cost. 3. Contractor/Agency will use original spares for maintenance.
GOYAL CONSTRUCTION COMPANY
JAI BHARAT CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid