| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.8 LAccepted-AOC 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹17.1 L+₹1.3 L (8.25%)Rejected-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L-2 | Rejected-AOC Being other than the lowest bidder | |
| 3 | L-3₹17.2 L+₹1.4 L (9.09%)Rejected-AOC | L-3 | Rejected-AOC Being other than the lowest bidder | |
| 4 | L-4₹18.8 L+₹3.0 L (19.2%)Rejected-AOC | L-4 | Rejected-AOC Being other than the lowest bidder |
Tender Value
₹22.7 L
EMD Value
₹45,400
Closing Date
24 Mar 2020, 6:00 pmClosed
Commander Works Engineer, MES, Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
MANNING AND OPERATION OF ELECTRIC SUPPLY INSTALLATION AND WATER SUPPLY INSTALLATION, SEWAGE INSTALLATION, DG SET AT MIL STN SHAHJAHANPUR UNDER GE (EAST) BAREILLY
2020_MES_328605_1
8200/B/616/E8
Open Tender
Civil Works
Item Rate
330 days
BAREILLY
As Per NIT
6 documents required · 6 mandatory
₹500
GE East Bareilly
₹45,400
Yes
21 Apr 2020
26 Feb 2020
30 Mar 2020
26 Feb 2020
24 Mar 2020
12 Mar 2020
26 Feb 2020 - 17 Mar 2020
Amount
Mannning and operation of over head lines HT/LT switch gear and internal complaints etc under AGE B/R Shahjahanpur to keep the MRS 24 hrs (in three shifts) MES service centre and all other installations in functional condition so that electric supply can be given to the users without any interuption by providing services 01 (one) electrician in each shifts for three shifts per day (i.e 03 Electricians per day) (each shift consisting of one electrician). Any fault occurs in feeder like disconnection of jumper breaking of fuse breaking of conductor, fault in HT/LT panels and cables of any or any other type of fault in the area of AGE B/R Shahjahanpur will be immediately attended/ rectified by the electrician detailed in shifts duty. Fuse wire any other stores required for rectifying the complaints/ faults will be provided by the department free for fixing. The SBA on duty at MRS 11 KV take over point will given complaints in writing to to shift electrician detailed by the contractor.
Note :- (a) The rate quoted by the contractor shall be of one electrician in three shifts (each shift of 08 hrs). Work will be carried out as per MES standard and as directed. (b) All shifts shall also be maintained properly by the contractor to avoid any delay in attending fault occurred in the area. (c) Proper shut down will be taken by the electrician from SBA on duty before attending the external complaints. (d) The personnel employed by the contractor must be of ITI qualified having adequate experience of minimum 4 years of work to the satisfaction of GE. (e) Relievers shall be provided by the contractor on no extra cost. (f) Dress and T&P of individual for the personalls deployed by the contractor for performing the above mentioned services will br provided by the contractor & the rate are deemed included in the quoted rates by the contractor. (g) The log sheets and priodical maint services will be mentioned by the personel deployed by the contractor. (h) The installations and sarrounding area would be kept clean and hygyne and maintain by the contractor.
Providing helper of unskilled trade for item No 1 in second shift from 16.00 hrs to 00.00 hrs each day to assist in duties as mentioned in item No 1.
Maintenance & operation and running of sewage pumps centrifugal non clog vertical type shift driven of cap 2040 LPS at 15 mtr head coupled with electric induction motor controlled with LT panel board etc at sump No 3 to keep sewage sump/well free from submerging of suction line more than 10 with sludge etc at any time in 01 FGM in Each shift for 02 shifts per day at sump No 3 (0600 hrs to 1400 hrs and 1400 hrs to 2200 hrs), (i.e. total 02 FGM per day) including maintaining log sheet and other periodical maint record all as specified and directed. Note :- The contractor shall be responsible for safety, security and upkeep of installation as per MES standard of installation during 2200 hrs to 0600 hrs also i.e 3rd shift in addition to 1st and 2nd shift. The contractor shall also keep the following aspect in mind while quoting unit rate for each shift. Note :- Shift timing can be change as per direction of GE.
(a) The contractor shall stop all leakage from gland coupling, joint etc with in the pump house premises including supply of spares for it at his own cost. (b) The contractor shall carry out minor repairs, oiling, mobi oil, greasing, painting etc to pumps and motors. LT panel board and white washing, cleaning of premises off grass roots, vegetation etc at own cost. (c) Whether the repair are minor or not, the decision of acepting officer shall be final and binding. However in case of disputes with regard to this the decision of next higher engineer authority shall be final and binding and conclusive. (d) In case of main electric supply is fails, generator electric supply will be maintained by the contractor. (e) FOL like DHPP 'N' and 10W 30 for stand by DG set will be issued to the contractor free of cost by the department. (f) The personnel employed by the contractor must be of ITI qualified having adequate experience of minimum 4 years of work to the satisfaction of GE. (g) Relievers shall be provided by the contractor on no extra cost. (h) The installations and sarrounding area would be kept clean and hygyne and maintain by the contractor.
Maintenance & operation and running of GGS pump house of vertical turbine/ submersible/ centrifugal pumping set of cap 35000 gallon per hour discharge cap at 60 mtr head with electric motor etc. Chloronome plant, bleaching powder dozer, LT panel boards and stand by DG set for filling water in overhead of cap 100000 gallons and 1x50000 gallons cap thrice a day in 24 hours i.e 01 (one) FGM in each shift for 03 shifts per day (0800 hrs to 1600 hrs, 1600 hrs to 2400 hrs and 2400 hrs to 0800 hrs) at 01 pump houses (i.e total 03 FGM per day) and supplying sozer (2 PPM dose) at pump house twicr a day (i.e 0500 hrs to 0800 hrs, 1200 hrs to 1400 hrs ) or timing of water given by GE be followed and maint and operation of connected rising/ distribution valves (sluice valve/NRV/Gate valve etc) within the pump house premises of the pump house for distribution mains and rising mains with the pump house premises and at inter connection of rising mains in between two pump houses including maintaining log sheet and other periodical maint record all as specified and directed.
Note :- The contractor shall also keep the following aspect in mind while quoting rate ffor each shift. (a) The contractor shall stop all leakage from gland coupling, joint etc with in the pump house premises including supply of spares for it at his own cost. (b) The contractor shall carry out minor repairs, oiling, mobi oil, greasing, painting etc to pumps and motors. LT panel board and white washing, cleaning of premises off grass roots, vegetation etc at own cost. (c) Whether the repair are minor or not, the decision of acepting officer shall be final and binding. However in case of disputes with regard to this the decision of next higher engineer authority shall be final and binding and conclusive. (d) In case of main electric supply is fails, generator electric supply will be maintained by the contractor. (e) FOL like DHPP 'N' and 10W 30 for stand by DG set will be issued to the contractor free of cost by the department. (f) The personnel employed by the contractor must be of ITI qualified having adequate experience of minimum 4 years of work to the satisfaction of GE. (g) Relievers shall be provided by the contractor on no extra cost. (h) The installations and sarrounding area would be kept clean and hygyne and maintain by the contractor.
Maintenance & operation and running of swimming pool filteration plant and Map pump house of vertical turbine/ submersible/ centrifugal pumping set of cap 35000 gallon per hour discharge cap at 60 mtr head with electric motor etc. Chloronome plant, bleaching powder dozer, LT panel boards and stand by DG set for filling water in overhead of cap 100000 gallons and 1x50000 gallons cap twice a day in 16 hours i.e 01 (one) FGM in 02 shifts (0800 hrs to 1600 hrs, 1600 hrs to 2400 hrs ) at 02 pump houses (i.e total 04 FGM per day) and supplying sozer (2 PPM dose) at pump house thrice a day (i.e 0500 hrs to 0800 hrs, 1200 hrs to 1400 hrs and 1700 hrs to 2000 hrs or timing of water given by GE be followed and maint and operation of connected rising/ distribution valves (sluice valve/NRV/Gate valve etc) within the pump house premises of the pump house for distribution mains and rising mains with the pump house premises and at inter connection of rising mains in between two pump houses including maintaining log sheet and other periodical maint record all as specified and directed.
Note :- The contractor shall also keep the following aspect in mind while quoting rate for each shift. (a) The contractor shall stop all leakage from gland coupling, joint etc with in the pump house premises including supply of spares for it at his own cost. (b) The contractor shall carry out minor repairs, oiling, mobi oil, greasing, painting etc to pumps and motors. LT panel board and white washing, cleaning of premises off grass roots, vegetation etc at own cost. (c) Whether the repair are minor or not, the decision of acepting officer shall be final and binding. However in case of disputes with regard to this the decision of next higher engineer authority shall be final and binding and conclusive. (d) In case of main electric supply is fails, generator electric supply will be maintained by the contractor. (e) FOL like DHPP 'N' and 10W 30 for stand by DG set will be issued to the contractor free of cost by the department. (f) The personnel employed by the contractor must be of ITI qualified having adequate experience of minimum 4 years of work to the satisfaction of GE. (g) Relievers shall be provided by the contractor on no extra cost. (h) The installations and sarrounding area would be kept clean and hygyne and maintain by the contractor.
M/S WASEEM KHAN CONTRACTOR
RAZA ENTERPRISES
jay maa engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .