Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.7 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder for the work. | |
| 2 | L-2₹8.2 L+₹29,329 (3.73%)Rejected-Finance | L-2 | Rejected-Finance other than the lowest bidder |
Tender Value
₹11.2 L
EMD Value
₹22,400
Closing Date
2 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr Bharat Singh Laspal, SE, CWE Bhopal
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
REPAIR AND MAINTENANCE OF HT 33 KV SUBSTATION AND ALLIED WORKS UNDER EXTERNAL ELECTRIC SUPPLY AT DSCC AYODHYA NAGAR UNDER GE DRONACHAL
2023_MES_623731_2
83851/E8
Open Tender
Civil Works
Item Rate
180 days
DRONACHAL
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE Dronachal
₹22,400
Yes
12 Jan 2024
9 Dec 2023
4 Jan 2024
9 Dec 2023
2 Jan 2024
16 Dec 2023
9 Dec 2023 - 16 Dec 2023
Amount
Dismantling insulators any type, any size complete all as specified and as directed.
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside for re-use or removing to store or for schedule of credit
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. or carrying to MES store (spare/components for replacement to be provided free by department)
Dismantling ACSR or AAC conductors removing to store or taken on schedule of credit complete all as specified and as directed.
Dismantling and taking down Lightning arrester of any size and any type complete all as specified and as directed.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 6.35 kV/ 11 kV, upto any size of nominal cross sectional area of main conductor, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for reuse or for taking credit all as specified and directed by the Engineer-in-Charge.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Dismantling and taking down of End termination/ Straight through cable joint of any size, any type, any numbers of core for any voltage complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 19 kV/ 33 kV, single phase, earthed system, 1 core, screened, armoured power cable, 240 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 19 kV/ 33 kV, three phase, earthed system, 1 core, screened, armoured power cable, 185 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
Supplying & laying in trenches, in road cutting and along pole 100 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supply & laying unreinforced precast concrete cable cover class HVP type 2, with peak shape, dimension 450 mm X 180 mm X 40 mm and 65 mm peak thickness as per IS 5820: 1970 complete all as specified and as directed.
S & F XLPE cable end termination, heat shrinkable, outdoor type complete with jointing material and accessories suitable for voltage 19 kV/ 33 Kv (Earthed), 3 core, 120 sqmm to 185 sqmm complete all as specified and as directed.
S & F 33 kV polymeric composite pin insulator, conforming to IEC 61109, material of core (FRP rod): borron free ECR, material of sheds: silicon rubber, material of top end fittings: spheroidal graphite cast iron, malleable cast iron or forged steel, material of bottom end fittings: forged steel, sealing compound for end fitting: RTV Silicon, colour of sheds: grey, rated voltage: 33 kV, highest voltage: 36 kV, dry power frequency withstand voltage: 95 kV, wet power frequency withstand voltage: 75 kV, dry power frequency flashover voltage: 130 kV, wet power frequency flashover voltage: 90 kV, dry lightning impulse withstand voltage: (a) Positive: 170 kV, (b) Negative: 180 kV, dry lightning impulse flashover voltage: (a) Positive: 210 kV, (b) Negative: 230 kV, RIV at 1 MHz when energised at 10 kV / 30 kV (rms) under dry condition < 70 microvolt, creepage distance (minium): 900 mm, minimum failing load: 10 kN complete all as specified and as directed.
S & F 33 kV polymeric composite disc insulator, conforming to IEC 61109, material of core (FRP rod): borron free ECR, material of sheds: silicon rubber, material of end fittings: spheroidal graphite cast iron, malleable cast iron or forged steel, sealing compound for end fitting: RTV Silicon, colour of sheds: grey, rated voltage: 33 kV, highest voltage: 36 kV, dry power frequency withstand voltage: 95 kV, wet power frequency withstand voltage: 75 kV, dry power frequency flashover voltage: 130 kV, wet power frequency flashover voltage: 90 kV, dry lightning impulse withstand voltage: (a) Positive: 170 kV, (b) Negative: 180 kV, dry lightning impulse flashover voltage: (a) Positive: 210 kV, (b) Negative: 230 kV, RIV at 1 MHz when energised at 10 kV / 30 kV (rms) under dry condition < 70 microvolt, creepage distance (minium): 900 mm, minimum failing load: 70 kN complete all as specified and as directed.
M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Fixing only cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
S & F gang operated air break switch as per IEC 62271-103 amended upto date, rocking/ tilting type, suitable for both horizontal and vertical mounting, three poles, outdoor type, nominal system voltage 33 kV, rated voltage 36 kV, rated frequency 50 Hz, continuous current rating 200 Amps, rated short time withstand current for three seconds 20 kA, rated peak withstand current for three seconds 50 kA, rated lightning impulse withstand voltage (i) to earth and between poles 170 kV (Peak) (ii) across the isolating distance 195 kV (Peak), power frequency withstand voltage between (i) earth & poles 70 kV (rms) (ii) across the isolating distance 80 kV (rms), minimum isolating distance in open position 520 mm, phase to phase clearance 1220 mm, minimum cross sectional area of fixed contact 300 sqmm, minimum cross sectional area of moving contact 250 sqmm, copper connector having minimum cross sectional area of 250 sqm, maximum current density of 1.6 Amps/ sqmm for all current carrying parts, single number of brake per phase, medium grade galvanised iron pipe of 32 mm nominal bore and 5 to 6 metre length in single piece for operating pipe, pad-locking in both ‘on’ and ‘off’ position with indicators, electroplated nonferrous parts, hot dip galvanised ferrous parts, 3 Nos polymer post insulator per phase as per IEC 61109 amended upto date having rated voltage 36 kV, minimum creepage distance 900 mm, impulse withstand voltage 170 kV, wet power frequency withstand voltage 75 kV, dry wet power frequency withstand voltage 75 kV complete all as specified and as directed.
Supply and fix in repairs DO fuse assembly, suitable for horizontal and vertical operation, triple pole mounted on polymer HT insulator 6 Nos and mild steel galvanised steel frame rating upto 200 Amp, 33 kV complete with DO fuse and electrical connections, jumpering by ACSR conductor and connectors complete all as specified and as directed.
S & F drop out fuse element for 33 kV line, 15 A with fire resistant ferrule complete all as specified and as directed.
S & F drop out fuse barrel for 33 kV line, 15 A with fire resistant tube and joint with ferrule complete all as specified and as directed.
Supply and fix metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, distribution class, heavy duty, nominal discharge current 10 kA, repetitive charge transfer rating (Qrs) more than 0.4 C, thermal charge transfer rating (Qth) more than 1.1 C, nominal system voltage 33 kV, highest system voltage 36 kV, rated voltage of arrester 27 kV, continuous operating voltage 21.6 kV, temporary overvoltage (31.50 kV for 1 s, 29.80 kV for 10 s, 28.00 kV for 100 s), rated short circuit current 20 kA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 170 kV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 86 kV, high current impulse withstand capability (4/10 µs) 100 kA, minimum creepage distance 900 mm complete all as specified and as directed.
Supplying, fixing, testing and commissioning in repairs potential transformer 33 kV/√3 - 110 V/√3 / 110 V/√3 with class 1 for metering and class 3P for protection, outdoor type, single phase, oil immersed and self cooled type having adequate VA burden not less than 50 VA conforming to IS complete all as specified and as directed.
Material and Labour for the following testing of transformer of 1000 kVA, 33 kV/ 433 V voltage ratio on the site at different locations under the GE and submission of reports to the Engineer-in-Charge complete all as specified and as directed. (a) Operational checking of the protection system (b) Insulation resistance (IR) measurement (c) Measurement of capacitor bushings (d) Measurement of voltage ratio (turns ratio) (e) Measurement of vector group or polarity of the transformer (f) Measuring of winding resistance (g) Measurement of vibration of the transformer (h) Test of the magnetic balance of the transformer (i) A measure of Frequency Balance Response (FRA) of the transformer (j) Measurement of floating neutral point (k) The measure of short-circuit impedance and magnetizing current of the transformer (l) Operational measurement on OLTC’S (m) Measurement of stability of differential, REF of transformer (n) Measurement of bushing current transformers (BCT’S) (o) Measurement of copper losses
S & F upto and including 1.1 kV/ 2000 A bushing with copper stem including both porcelain parts and metal parts with accessories as per IS 3347 Part 1 (section 1 & 2) complete all as specified and as directed.
S & F 36 kV/ 250 A bushing with copper stem including both porcelain parts and metal parts with accessories as per IS 3347 Part 5 (section 1 & 2) complete all as specified and as directed.
M & L for servicing/ minor repairs/ painting of 33 kV grid station, consisting of steel poles, channels, clamps, cross arms, 2 Nos of transformers of capacity 1000 kVA, one feeder, connected current transformers, potential transformers including greasing of all moving parts, replacement of rusted/ unserviceable nuts, bolts, washers, jumpers, PG clamps, T connectors, clamps etc. complete all as specified and as directed. Note: (a) The contractor shall visit the site prior to quoting his rate for this item. (b) The limited shut-down period of upto two hours shall be given to the contractor for painting works. The work of painting shall be planned accordingly by deploying sufficient manpower and phasing of works for numbers of days.) (c) The electric pole, cross arms, channels etc. shall be painted with two coats of aluminium paint over a coat of aluminium red oxide primer. (d) Spray painting with two coats of synthetic enamel paint of approved shade shall be applied to transformers, CTs, PTs etc. (e) Numbering shall be done with synthetic enamel paint of approved shed and shall be in approved shape and style.
Carrying out field test of transformer oil for visual inspection (colour and appearance), break down voltage, water content and acidity before and submission of report all as per IS 1866: 2017 and IEC 60422: 2013 complete all as specified and as directed.
Filtration, Dehydration, reconditioning of transformer oil by using filtering equipment, vacuum dehydrator etc. to obtain minimum break down voltage of 60 kV and maximum water content of 30 mg/kg as per IS 1866: 2017 and IEC 60422: 2013 complete all as specified and as directed.
Supply and fill unused mineral insulating oils conforming to IS 335: 2018, Type II Class (Transformer oils), Uninhibited (U), pour point -10⁰C, vacuum filtered in a laboratory, Breakdown voltage of min 70 kV at 2.5 mm gap complete all as specified and as directed.
S & F silica gel breather containing 1000 gms silica gel, indicating type, 4 to 6 mm standard size of the particle, blue colour silica, breather body made out of aluminium pressure die cast, shot blasted and powder coated, container and oil cup made out of 143R grade UV resistant polycarbonate, all gaskets made out of nitrile cork (RC 70C) rubber, flanged type. breather piping doesn’t include any valve between conservator and breather, removable type mounted at suitable height from ground level, tested for 0.35 kg / cm for all joints complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
M & L for loose filling with broken stone or boulder aggregates of gauge 40 to 80 mm in soakage pits, soakage wells, on open space etc. complete all as specified and as directed.
Supply and spread lime powder for two pole structures and 33 kV main receiving station complete all as specified and as directed.
S & F nominal 3.0 mm thick insulating mats of size 2 m X 1 m, made of elastomer conforming to IS-15652: 2006 and meeting the requirement of IS- 5216 (Part -1 & 2) IS 8437, IEC-479 Pub -1 along with suitable adhesive/ homebound, PV resin water proofing compound and sealing material as per recommendation of Annex 'A’, Clause- 'C’ of IS- 15652 and suitable for class - C upto 33 kV complete all as specified and as directed.
M & L for preparation of old steel surfaces of fencing any mesh size and any nominal dia and applying two coats of Aluminium paint complete all specified and directed.
M & L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 250 mm X 200 mm complete all as specified and as directed.
M & L for cleaning of areas of substation complex by surface dressing or trimming of natural ground to remove small inequalities not exceeding 15 cm deep (including removing vegetation/shrubs/brush wood/under-growth), cleaning of drains & carrying away the rubbish to a distance of not exceeding 50 meters away complete all as specified and as directed. Note: (i) Cleaning the complete substation shall be considered as one only.
PRADEEP SISODIYA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .