| 1 | L1₹51.3 LAccepted-Finance VILLAGE SHAH PO DHARGAURA TESHIL RAMPUR DISTT SHIMLA HP | SHIMLA | HIMACHAL PRADESH | 171001 | L1 | Accepted-Finance L1 | |
| 2 | L2₹59.5 L+₹8.3 L (16.1%)Rejected-Finance VILL SHILLAI P O JANEDGHAT TEHSIL KANDAGHAT DISTRICT SOLAN HP | SOLAN | HIMACHAL PRADESH | 171102 | L2 | Rejected-Finance L2 | |
| 3 | L3₹60.7 L+₹9.4 L (18.4%)Rejected-Finance V P O LOTE TEHSIL DISTT LAHAUL DISTT LAHAUL SPITI H P 175133 | LAHUL AND SPITI | HIMACHAL PRADESH | 175133 | L3 | Rejected-Finance L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical VPO SAPNI TEHSIL SANGLA DISTT KINNAUR HP | SHIMLA | HIMACHAL PRADESH | 172101 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹72,400
Closing Date
17 Feb 2025, 5:00 pmClosed
District Project Manager, HPCDP JICA-ODA, Solan
O/o District Project Manager, HPCDP (Phase-II), JICA-ODA, Solan
Improvement of Flow Irrigation Scheme Skibba at Village Skibba GP Rispa Tehsil Moorang District Kinnaur HP
2025_HPCDP_99553_1
NoAgrSLNDPMUJICAODAPhaseII G 42 2007 dt07.02.2025
Open Tender
Civil Works
Item Rate
360 days
Village Skibba GP Rispa Tehsil Moorang District Ki
Please refer Tender documents.
14 documents required · 14 mandatory
₹1,500
District Project Manager, HPCDP JICA-ODA, Solan
₹72,400
V.P.O Chambaghat Distt. Solan (H.P.)173213
2 Apr 2025
7 Feb 2025
18 Feb 2025
7 Feb 2025
17 Feb 2025
7 Feb 2025
11 Feb 2025
Amount
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in - charge (Item Code HPPWDSR 2020 - Chapter 15.2): (Item Code HPPWDSR 2020 - Chapter 15.9.2)
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge (Item Code HPPWDSR 2020 - Chapter 15.2): (Item Code HPPWDSR 2020 - Chapter 15.2.1)
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. (Item Code HPSR 2020 - Chapter 2.9) Ordinary Rock : (Item Code HPSR 2020 - Chapter 2.9.1)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (Item Code HPPWDSR 2020 - Chapter 2.8) All Kinds of soil : (Item Code HPPWDSR 2020 - Chapter 2.8.1)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. (Item Code HPPWDSR 2020 - Chapter 2.10) Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia. (Item Code HPPWDSR 2020 - Chapter 2.10.1.2) All Kinds of Soil
Centering and shuttering including strutting, propping etc. and removal of form work for :
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (Item Code HPPWDSR 2020 - Chapter 5.9.2)
Extra Allowance for formwork in concrete lining.
In Bed
In Side Slope
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:5:10 (1 Cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (Item Code HPPWDSR 2020 - Chapter 4.1.5)
Providing and laying in position reinforced cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and curing complete in :
All work up to plinth level 1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) (Item Code HPPWDSR 2020 - Chapter 4.1.3)
In retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing (Item Code HPPWDSR 2020 - Chapter 4.2.3)
In suspended floors, landing of shelves and their support, balconies, beams, griders bressumers and cantilevers upto floor two level, excluding cost of centering ,shuttering,finishing and reinforcement (Item Code HPPWDSR 20009 - 09310300)
Providing and laying in position reinforced cement concrete 1:1.5:3 (1cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) and curing complete in :
All work up to plinth level excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing cement concrete lining 15 cm thick or less for irrigation channels, using cement concrete 1:2:4 (1 cement2 sand :4 stone aggregate 20 mm nominal size) in:
Bed complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Side slopes complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing Mild steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (Item Code HPPWDSR 2020 - Chapter 10.2)
Providing, laying, jointing, commissioning & testing in trenches HDPE pipes of following diameters & classes as per IS 4984 (1995) and jointing the pipes with push type compression joints by hydraulically operated machines, butt fussion welding & electro fusion welding machines i/c necessary fittings, bends, tees, unions, flanges, collars & reducers etc. confirming to IS 8360 & IS 8008 with latest ammendments & shall be provided as per site conditions. Flanging of the pipes shall be made as & where required. Jointing shall be confirming to IS code 8008 & IS 7634, stub ends will be welded on pipes & MS flange shall be provided with slip on covered by epoxy coating/plastic powder. The flange should be confirm to ANSI B 16.5 with necessary nuts & bolts. All manufacturing maerial used shall be in accordance to IS 4427-2007 (latest revision) with 100 % virigin pre-compounded or natural PE resin. Jointing shall be complete in all respects i/c testing at site upto entire satisfaction of the Engineer-in-Charge.
HDPE Pipe 110 mm ɸ (PN. 6.0, PE. 100)
HDPE Pipe 160 mm ɸ (PN. 6.0, PE. 100)
Providing, laying, jointing and testing in trenches (to level or grade) GMS tube ( IS : 1239-2004) of 150 mm dia, & medium Class conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge. (EARTH WORK IN TRENCHES TO BE MEASURED PAID FOR SEPARATELY)
Providing, welding and fixing of M.S. flanges @ 1% of Joints at suitable reaches, conforming to following table 5; 150 mm as per IS:6392-1971 (Latest with upto date amendments) and welding of MS Flanges with G.I. Pipes/ MSERW pipes in two layers on both faces to make the joint leak proof (The cost of providing and laying of G.I.Pipes/MSERW Pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrode as per IS : 814-1991 and required number of nuts & bolts conforming to IS: 1364. The thickness of gasket not less than 3.00mm conforming to IS : 2712-1998. The work shall be done as per entire satisfaction of Engineer-in-Charge within all leads and lifts.
Providing circumferential Butt welded joints by electrical arc welding to GI pipe 150 mm Dia. Having following dia. Of pipe,wall thickness,welded in requisite numbers of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of ADVANI Orelikon (Adore)- CITOJET / ESAB make, conforming to IS 814-1991, at site of work complete in all respects,including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-charge.
Providing & fixing of 63 mm hydrant with Main or Submain line including HDPE Riser 63 mm Double Threaded PN-10.0 ,63 mm PP Ball Valve, Bend, Male Female Coupler Threaded PN-10.0,Service Saddle PN-10.0 and Elbow bend with Steel Clamp complete in all respect and jointing by electrofusion process (as per requirement of main & sub main line). For Distribution System with 160 mm dia
Providing & Fixing Valve Box for Hydrant Size 12" complete in all respects and upto entire satisfaction of engineer-in charge.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. (Item Code HPPWDSR 2020-Chapter 13.52.1) On Steel Work
Printing new lettters and figures of any shade with synthetic enamel black or any other approved colour to give n even shade as per drawings and technical specifications clause 1701 in English and roman, hyphen, commas and the like not to be measured and paid for
AJAY (BID ID -494139)
JOGINDER SINGH (BID ID -494319)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .