Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.1 LAccepted-AOC B 50A VIKAS NAGAR EXTN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹14.1 L Quoted ₹14.8 L | 1 | Accepted-AOC LOWEST |
| 2 | 2₹19.6 L+₹4.8 L (32.2%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | ₹19.6 L+₹4.8 L (32.2%) | 2 | Rejected-Finance NOT LOWEST |
| 3 | 3₹19.7 L+₹4.9 L (33.3%)Rejected-Finance | ₹19.7 L+₹4.9 L (33.3%) | 3 | Rejected-Finance NOT LOWEST |
| 4 | 4₹20.0 L+₹5.2 L (35.1%)Rejected-Finance | ₹20.0 L+₹5.2 L (35.1%) | 4 | Rejected-Finance NOT LOWEST |
| 5 | 5₹23.4 L+₹8.6 L (58.2%)Rejected-Finance | ₹23.4 L+₹8.6 L (58.2%) | 5 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | M/s Prakash Enterprises L4 | M/S Anand Enterprises L2 | S.R. Constructions L3 | Commercial Traders L6 | MISHRA ELECTRICAL L5 | vineet pal L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down electric water heater/ geysers of capacity 25/ 50 ltrs from its mounting place for repair and deposit to MES complaint cell and re-fixing the same after repair and testing complete all as specified and as directed by Engr-in-charge.
NOTE:- The spare items required for repair shall be measured and paid seperately. | 350 | Each | 20 ₹7,000 | 5 ₹1,750 Lowest | 20 ₹7,000 | 80 ₹28,000 | 5 ₹1,750 Lowest | 10 ₹3,500 |
| 2.00 | S&F in replacement of heating element of 1.5 KW rating double tube type with cup type of circular /triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete all as specified and as directed by Engr-in-Charge. | 8 | Each | 300 ₹2,400 | 400 ₹3,200 | 290 ₹2,320 | 354 ₹2,832 | 310 ₹2,480 | 240 ₹1,920 Lowest |
| 3.00 | S&F in replacement of heating element triangle / cup type of 2.0 KW rating double tube type with cup type of circular /triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete all as specified and as directed by Engr-in-Charge. | 300 | Each | 250 ₹75,000 | 400 ₹1,20,000 | 290 ₹87,000 | 385 ₹1,15,500 | 379 ₹1,13,700 | 220 ₹66,000 Lowest |
| 4.00 | S&F in replacement of the heat proof rubber PVC gasket suitable for the different make of 25 litres capacity geysers as per site requirement complete all as specified and as directed by Engr-in-Charge. | 350 | Each | 50 ₹17,500 | 10 ₹3,500 Lowest | 30 ₹10,500 | 15 ₹5,250 | 10 ₹3,500 Lowest | 30 ₹10,500 |
| 5.00 | S&F in replacement of heavy duty element holding assembly with provision for safety valve in its inlet, pocket for thermostat/ thermal cut system and drain plug suitable for 25 litres capacity geysers complete all as per site requirement and directed by Engr-in-Charge . | 250 | Each | 350 ₹87,500 | 350 ₹87,500 | 290 ₹72,500 | 410 ₹1,02,500 | 384 ₹96,000 | 150 ₹37,500 Lowest |
| 6.00 | S&F in replacement of geyser fusuble drain plug / safety valve pressure valve ISI marked as per site requirement complete all as specified and as directed by Engr-in-Charge. | 95 | Each | 20 ₹1,900 Lowest | 50 ₹4,750 | 100 ₹9,500 | 50 ₹4,750 | 20 ₹1,900 Lowest | 195 ₹18,525 |
| 7.00 | S&F in replacement of geyser multi- function safety valve pressure valve 15mm size, ISI marked as per site requirement complete all as specified and as directed by Engr-in-Charge. | 85 | Each | 120 ₹10,200 | 50 ₹4,250 | 60 ₹5,100 | 150 ₹12,750 | 20 ₹1,700 Lowest | 320 ₹27,200 |
| 8.00 | S&F stainless steel inner tank 24 gauge heavy duty in replacement of stainless steel inner tank suitable for the existing 25 ltrs capacity geysers complete all as specified and as directed by Engr-in-Charge. | 285 | Each | 490 ₹1,39,650 | 600 ₹1,71,000 | 700 ₹1,99,500 | 1,100 ₹3,13,500 | 850 ₹2,42,250 | 310 ₹88,350 Lowest |
| 9.00 | S&F in replacement of capillary thermostate for the geysers 25 Ltrs capacity suitable for Bajaj make or as per site requirement complete all as specified and as directed by Engr-in-Charge . | 55 | Each | 150 ₹8,250 | 300 ₹16,500 | 90 ₹4,950 Lowest | 115 ₹6,325 | 110 ₹6,050 | 360 ₹19,800 |
| 10.00 | S&F in replacement of thermostate for the geysers 25 Ltrs to 50 ltrs capacity as per site requirement complete all as specified and as directed by Engr-in-Charge . | 295 | Each | 80 ₹23,600 Lowest | 300 ₹88,500 | 90 ₹26,550 | 120 ₹35,400 | 110 ₹32,450 | 260 ₹76,700 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
6 Jul 2026, 6:00 pmClosed
GE (AF) PALAM DELHI CANTT 10
GE (AF) PALAM DELHI CANTT 10
REPAIR / REPLACEMENT OF INTERNAL WIRING, SWITCH SOCKETS, MCBs, DBs, SUB MAIN WIRING, FITTINGS FIXTURES, FANS, GEYSERS AND CONNECTED ITEMS IN OTM and MD ACCN IN 1 AFSR AND CAMP AREA AT AF STN PALAM UNDER GE (AF) PALAM DELHI CANTT - 10
2026_MES_772285_1
8026/A/T-29/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Palam Delhi Cant-10
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) PALAM
₹40,000
Yes
27 Aug 2026
15 Jun 2026
13 Jul 2026
15 Jun 2026
6 Jul 2026
29 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down electric water heater/ geysers of capacity 25/ 50 ltrs from its mounting place for repair and deposit to MES complaint cell and re-fixing the same after repair and testing complete all as specified and as directed by Engr-in-charge.
NOTE:- The spare items required for repair shall be measured and paid seperately. | 350 | Each | - | - |
| 2 | S&F in replacement of heating element of 1.5 KW rating double tube type with cup type of circular /triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete all as specified and as directed by Engr-in-Charge. | 8 | Each | - | - |
| 3 | S&F in replacement of heating element triangle / cup type of 2.0 KW rating double tube type with cup type of circular /triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete all as specified and as directed by Engr-in-Charge. | 300 | Each | - | - |
| 4 | S&F in replacement of the heat proof rubber PVC gasket suitable for the different make of 25 litres capacity geysers as per site requirement complete all as specified and as directed by Engr-in-Charge. | 350 | Each | - | - |
| 5 | S&F in replacement of heavy duty element holding assembly with provision for safety valve in its inlet, pocket for thermostat/ thermal cut system and drain plug suitable for 25 litres capacity geysers complete all as per site requirement and directed by Engr-in-Charge . | 250 | Each | - | - |
| 6 | S&F in replacement of geyser fusuble drain plug / safety valve pressure valve ISI marked as per site requirement complete all as specified and as directed by Engr-in-Charge. | 95 | Each | - | - |
| 7 | S&F in replacement of geyser multi- function safety valve pressure valve 15mm size, ISI marked as per site requirement complete all as specified and as directed by Engr-in-Charge. | 85 | Each | - | - |
| 8 | S&F stainless steel inner tank 24 gauge heavy duty in replacement of stainless steel inner tank suitable for the existing 25 ltrs capacity geysers complete all as specified and as directed by Engr-in-Charge. | 285 | Each | - | - |
| 9 | S&F in replacement of capillary thermostate for the geysers 25 Ltrs capacity suitable for Bajaj make or as per site requirement complete all as specified and as directed by Engr-in-Charge . | 55 | Each | - | - |
| 10 | S&F in replacement of thermostate for the geysers 25 Ltrs to 50 ltrs capacity as per site requirement complete all as specified and as directed by Engr-in-Charge . | 295 | Each | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_864774.xls
BOQ • 0.54 MB
tender.pdf
Tender Documents • 0.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .