Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95,955Accepted-AOC GODHA PO KUSUNDA DHANBAD 828116 JH | DHANBAD | DHANBAD | JHARKHAND | 828116 | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.1 L+₹9,172 (9.56%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
20 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I)(P)(FY) AMBAJHARI
AGE(I)(P)(FY) AMBAJHARI ORDNANCE FACTORY ESTATE AMBAJHARI 440021
PROVISION OF SENTRY POST ADJACENT TO SQAE(A), AMBAJHARI (ADMIN BUILDING), NAGPUR
2021_MES_410003_2
8484
Open Tender
Civil Works
Item Rate
30 days
AGE(I)(P)(FY) AMBAJHARI
As per tender documents
5 documents required · 5 mandatory
₹300
AGE(I)(P)(FY) AMBAJHARI
₹5,000
Yes
10 Mar 2021
6 Feb 2021
22 Feb 2021
6 Feb 2021
20 Feb 2021
8 Feb 2021
60 days
Amount
Excavation in trenches, n. exc 1.5 m wide and not exc 1.5 depth for fdn, etc or for shafts as in culvert and getting out in hard / dense soil , complete all as specified & as directed by Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil, etc complete all as specified & as directed by Engineer-in-Charge.
M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) cement concrete in foundation filling and mass concrete, etc complete all as specified & as directed by Engineer-in-Charge.
M & L for RCC nominal mix concrete 1:2:4 type B1, using 20mm graded aggregate as in footing, foundation, etc complete all as specified & as directed by Engineer-in-Charge.
M & L for RCC nominal mix concrete 1:2:4 type B1, using 20mm graded aggregate as in Column, etc complete all as specified & as directed by Engineer-in-Charge.
M & L for RCC nominal mix concrete 1:2:4 type B1, using 20mm graded aggregate as in lintels, plinth beams etc over 1.5 Mtr span etc complete all as specified & as directed by Engineer-in-Charge.
M & L for RCC nominal mix concrete 1:2:4 type B1, using 20mm graded aggregate as in roof beams and slab, etc complete all as specified & as directed by Engineer-in-Charge.
M&L for Brickwork with Fly Ash Bricks, straight or curved on plan exc 6m mean radius built in CM (1:6), etc complete all as specified & as directed by Engineer-in-Charge.
M&L for rendering 5 mm thick on concrete surfaces in cement mortar 1:3 in ceiling surface and finishing the surfaces even and smooth without using extra cement, etc complete all as specified & as directed by Engineer-in-Charge.
M & L for 15 mm thick rendering in CM 1:4 on external surface of fair faces of brick work or concrete surfaces and finishing the surfaces even and smooth without using extra cement, etc complete all as specified & as directed by Engineer-in-Charge.
M & L for 15 mm thick rendering in CM 1:6 on internal surface of fair faces of brick work or concrete surfaces and finishing the surfaces even and smooth without using extra cement, etc complete all as specified & as directed by Engineer-in-Charge.
M & L for preparing new surfaces of walls, plastered or unplastered, and applying two coats of cement paint, white or tinted over a coat of primer, etc complete all as specified & as directed by Engineer-in-Charge.
M & L for applying 2 coats of white washing on new wall surface including preparation of new plastered suraface, etc complete all as specified & as directed by Engineer-in-Charge.
M & L for applying 2 coats of white washing on new ceiling surface including preparation of new plastered suraface, etc complete all as specified & as directed by Engineer-in-Charge.
M & L for rendering 15 mm thick on concrete surfaces in CM 1:4 in roof surface with WPC and finishing the surfaces even and smooth without using extra cement, etc complete all as specified & as directed by Engineer-in-Charge. (NOTE : WPC will be paid and measured seperately )
M & L for Supply only Integral Water proofing compound, etc complete all as specified & as directed by Engineer-in-Charge.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n.exc. 15 cm thick, spread, levelled and rammed including watering, etc complete all as specified & as directed by Engineer-in-Charge.
M&L for hardcore of broken stone or boulders of guage n exc 63 mm deposited, spread & levelled in layers n exc 15 cm thick, watered and rammed to a true surface, etc complete all as specified & as directed by Engineer-in-Charge.
Returning, filling in including spreading ,leveling,watering and well ramming in layer not exc 25cm complete all as specified & directed by Engineer-in-Charge.
Removing excavated material (soils) n exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point in soil , etc complete all as specified & as directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floor, finishing the surface , etc complete all as specified & as directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection, finishing the surface even and fair , etc complete all as specified & as directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in floor finishing the surface even and fair , etc complete all as specified & as directed by Engineer-in-Charge.
M & L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips , etc complete all as specified & as directed by Engineer-in-Charge
M & L for TMT Mild steel bars 6 to 10mm dia as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips , etc complete all as specified & as directed by Engineer-in-Charge
Used & waste of form work to sides of concrete , footings,foundations and plinth beams finished surface of concrete, etc complete all as specified & as directed by Engineer-in-Charge
Used & waste of form work to sides and soffit of columns finished surface of concrete, etc complete all as specified & as directed by Engineer-in-Charge
Used & waste of form work to sides and soffit of floor or roof beam, slabs, rough finished surface of concrete, etc complete all as specified & as directed by Engineer-in-Charge.
M&L for prearation of new steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromium primer etc complete all as specified & as directed by Engineer-in-Charge.
M&L for 5.5 mm thick sheet glass tinted ordinary quality as in glazing to aluminium doors, window partitions not exc 0.5 Sqm in each pane, etc complete all as specified & as directed by Engineer-in-Charge.
S & F Mild steel Framed work such as grills, square bars, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, and similar work conforming to Fe.290, Gde-E-165, etc complete all as specified & as directed by Engineer-in-Charge.
raghuveer constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .