| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC 256 MUNDHELA KHURD NEW DELHI 73 | L1 | Accepted-AOC work order has been awarded | |
| 2 | L2₹1.8 L+₹2,848 (1.59%)Rejected-Finance A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹2.0 L+₹19,147 (10.7%)Rejected-Finance | L3 | Rejected-Finance Not L1 |
Tender Value
₹2.3 L
EMD Value
₹4,540
Closing Date
11 Jan 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-II/SSZ
MUNICIPAL CORPORATION OF DELHI OFFICE OF THE Ex. ENGINEER (ELECT)-II 2 nd Floor Technical Laboratory Near NH-24 Ghazipur Delhi
provision of E l e c t r i c a l i n s t a l l a t i o n i n n e w l y constructed/renovated MI office at Karkardooma cremation ground in ward 204 and near sagar sadan apartment in ward 205 under shahadra south zone
2024_MCD_180398_1
EEE-II/SSZ/2023-24/31.7
Open Tender
Electrical Works
Item Rate
60 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹590
₹4,540
25 Jun 2024
4 Jan 2024
12 Jan 2024
4 Jan 2024
11 Jan 2024
4 Jan 2024
Amount
OD21902/2023-2024:DSR-22 1.30 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
OD21988/2023-2024:DSR22 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required class C
OD21989/2023-2024:DSR 22 1.14.3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4sq. mm + 1 X 4sq. mm earth wire
OD21991/2023-2024:DSR22 1.24.4supplying and fixing following modular switch/socket on the existing modular plate &switch box including connection but excluding modular plate etc as required 3pin 5/6A socket outlet
OD21992/2023-2024:DSR22 1.24.1 supplying and fixing following modular switch/socket on the existing modular plate &switch box including connection but excluding modular plate etc as required 5/6A switch
OD21990/2023-2024: DSR 22 1.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
OD21903/2023-2024:DSR-22 5.13 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
OD21904/2023-2024: DSR-22 2.14.1"Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A"
OD21906/2023-2024:DSR22 1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
OD21907/2023-2024:DSR22 7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
OD21908/2023-2024:DSR 22 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 8way, Double door
OD21910/2023-2024:Supply, installation, Testing and commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Currect (BLDC) Motor, class of insulation:B, 3 nos blades, 30 cm down rod, 2 nos. canopies, shackle kit, safety ropr, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, Earthng etc. complete as required.
OD21911/2023-2024:DSR 22.2.12.2 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amps
OD21912/2023-2024:DSR22 .2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single Pole)
OD21913/2023-2024:Supply of 12" (300mm) sweep 1400 rpm exhaust fan fan heavy duty complete with shutters, blades etc as reqd.
OD21914/2023-2024:SITC of single phase monoblock pump set complete with all accessories workable on 240/415V ,50HZ ac supply(a) 1HP(0.75KW)single phase pump set head from 12-30 meter suction and delivery 25*25mm
OD21915/2023-2024:5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
122.1.1:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*4 sqmm
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.27:SITC of 30W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =30 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.126:SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color
M/S. A.K. Electricals
GURUNANAK ENTERPRISES
Bidder Name
GURUNANAK ENTERPRISES
M/S. A.K. Electricals
M/s. Krishna Electric. Co.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .