Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-AOC | ₹4.2 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹4.4 Cr+₹16.1 L (3.80%)Rejected-Finance | ₹4.4 Cr+₹16.1 L (3.80%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹4.4 Cr+₹16.1 L (3.81%)Rejected-Finance 100 FEET ROAD NEAR POWER HOUSE ROAD CHOWK BATHINDA | BATHINDA | BATHINDA | PUNJAB | ₹4.4 Cr+₹16.1 L (3.81%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹4.5 Cr+₹31.5 L (7.44%)Rejected-Finance | ₹4.5 Cr+₹31.5 L (7.44%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹4.6 Cr+₹35.4 L (8.37%)Rejected-Finance | ₹4.6 Cr+₹35.4 L (8.37%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹4.4 Cr
EMD Value
₹5.2 L
Closing Date
12 Jan 2023, 6:00 pmClosed
CE Bathinda Zone
HQ Chief Engineer Bathinda Zone Bathinda Mil Stn - 151004
PROVN OF DEFICIENT SINGLE LIVING ACCN FOR JCOs AND ORs WITH COOK HOUSE DINING HALL AND OTHER ANCILLARIES AT BATHINDA MIL STN
2022_MES_558080_2
CE BTZ/BTD/TOKEN-17 OF 2022-23
Open Tender
Civil Works
Lump-sum
458 days
Bathinda
As per NIT
10 documents required · 10 mandatory
₹2,000
GE (P) Bathinda
₹5.2 L
Yes
25 Jan 2023
15 Dec 2022
14 Jan 2023
15 Dec 2022
12 Jan 2023
29 Dec 2022
Amount
Lump sum price worked out by the tenderer for "Building / Structure Work" as listed in Schedule ‘A’ Section - I.
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - II (Part-I)
Sch 'A' Sec - II (Part-II), (INTERNAL ELECTRIFICATION WORKS)
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Galvanised iron sunken terminal box (Min 60mm deep, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ/Sch 'A').
All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
Material and labour for concealed Point wiring for one light point controlled by two Nos- two way switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Galvanised iron sunken terminal box (Min 60mm deep, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Galvanised iron sunken terminal box (Min 60mm deep, suitable size ) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing switch piano flush type (ISI marked), 5/6Amps, single pole, two way (1 module), fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. Note :- Cost of laminated sheet cover for mounting of switch is included under respective item of BOQ (point wiring)
Material and labour for concealed wiring for TV antenna connection complete with coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a aluminium wire net drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Galvanised iron sunken terminal box of size 100mm x100mmx50mm concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of TV socket, including 2 pin TV antenna connection socket outlet round flush type duly marked with symbol of TV, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50 Cycle per second, size 300mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50 Cycle per second, size 450mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) TPN, 4 Way 415V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing RCBO 4 Pole, 40 Amps, 100mA capacity, 415 volts, with earth leakage and over load and short circuit protection, complete all as specified and as directed.
Supply and fixing RCBO 4 Pole, 25 Amps, 100mA capacity, 415 volts, with earth leakage and over load and short circuit protection, complete all as specified and as directed.
Supply and fixing RCBO 2 Pole, 16 Amp to 32 Amps, 100mA capacity, 240 volts, with earth leakage and over load and short circuit protection, complete all as specified and as directed.
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing blanking plate suitable for any type of DB complete all as specified and as directed by Engineer-in-charge.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (03 run i.e 2 runs for main phase and nutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 2.5 Sqmm single core (03 run i.e 2 runs for main phase and nutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 20mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- (i) Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. (ii) Qty 50 RM for Sch 'A' Sec - II (Part-II) (INTERNAl ELECTRIFICATION WORK) and Qty 30 RM for Sch 'A' Sec - IX (Part-II) (SUMMER APPLIANCES AND HOT WATER SUPPLY WORK)
Supply and fixing LED complete fitting including batten, T-8 Retro LED polycarbonate 1 x 20 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : Morethan 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing LED light fitting 1 x 10 Watt, appx 2 feet long environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : More than 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing LED light fitting 1 x 5 Watt, appx 1 feet long environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : More than 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing energy efficient LED street light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 5 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Subtotal
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II), (INTERNAL WATER SUPPLY WORKS)
Supply and fixing central hole basin mixer valve with regular spout, 15mm bore, brass chromium plated, for mixing hot & cold water, including fixing accessories with fittings for WHB complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “ROAD, PATH AND CULVERT WORK" as listed in Schedule ‘A’ Section -IV (Part-I)
Sch 'A' Sec - IV (Part-II), (ROAD, PATH AND CULVERT WORK)
Supply and laying/fixing 60 mm thick (M-35 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and no pigment, any shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.
Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in coping, mud stops, packing sides/around of interlocking tiles & similar work etc including slightly rounded complete all as specified and as directed by Engineer-in-charge.
Subtotal
Lump sum price worked out by the tenderer for “AREA DRAINAGE WORK" as listed in Schedule ‘A’ Section - V
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Section - VI
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORK" as listed in Schedule ‘A’ Section - VII (Part-I)
Sch 'A' Sec - VII (Part-II), (EXTERNAL WATER SUPPLY WORK)
Material and labour for Construction of brick masonary valve pit chamber size 90 X90 X90 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
Material and labour for Cutting of existing CI/DI pipes line 150mm bore for inserting and including tee of size 150x150x80mm for taping in trenches including run lead joint complete all as specified and as directed. NOTE:- Necessary earth work, CI/DI fitting, lead joint etc reqd to complete the job deemed to be included in the quoted rate.
Supply and fixing cast iron sluice valve PN 1 (long body ) ISI marked confirming to IS:14846-2000 suitable for 150 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Supply and fixing cast iron sluice valve PN 1 (long body ) ISI marked confirming to IS:14846-2000 suitable for 80 mm bore pipe, flanged ends, drilled, stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION WORK" as listed in Schedule ‘A’ Section - VIII (Part-I)
Sch 'A' Sec - VIII (Part-II), (EXTERNAL ELECTRIFICATION WORK)
Sand cushioning, with dry and clean sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used.
Supply and Installation, commissioning and testing of pole mounted transformer 63 KVA, 11/0.433KV, 50 Hz, step down, outdoor type, ONAN Cooled oil immersed copper wound energy efficient transformer, complete with first filling of IS-335 ISI marked filtered & dehydrated transformer oil and other standard fittings/accessories and 7 position OFF load circuit tap changer (Tapping range + 7.5% in steps of 2.5% Each) with vector group Dyn-11, with provision of HV bushing and LV cable box suitable for making connection of incoming HT cable and outgoing LT cable all as per IS 1180-2014 (Level-2) and complete with and including all required accessories for installation of transformer all as specified and directed. The transformer shall comprising of the following: (i) 03 Nos porcelain bushings with copper rod on HV side. (ii) 01 cable end box on LV side consisting of 04 Nos bushing. (iii) Oil conservator tank with filter type drain plug and oil level gauge. (iv) Dehydrating breather with first fill of silica gel (v) Explosive vent ,oil level gauge, oil drain filter valve, lifting hooks, oil filling hole with cap/plug with connection plate, Air release valve plug complete. (vi) 01 Nos 100mm dia, dial type thermo meter, vapor pressure type having range 0-120 degree with metal guard. (vii) 02 Nos earthing terminals on tank cover to facilitate fixing of 50x6mm GI earth strip for earthing of body including rating plate and terminal marking plate. All date shall me marked on Rating plate. (viii) First fill of unused and new transformer oil,IS-335 Marked filtered and tested upto 60KV die electric strngth at 2.5 mm air gap between testing electrode. Note:- (a) Pre commissioning test shall be carried out by SEI from HQ CE SWC or rep of accepting officer. All arrangement for the same shall be made by contractor with in over all cost quoted.
Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 65 protection made out of CRCA sheet 3.15 mm thick powder coated with seven tank process, fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with copper bus bar capacity 150 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40x40x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 100 Amp, 4 Pole 50 Hz, 415 V, 25KA with rupturing capacity, Thermal megnatic relay adjustable type – 01 No (incoming)
MCCB 100 Amp, 4 Pole 50 Hz, 415 V, 16KA with rupturing capacity, Thermal megnatic relay adjustable type – 01 No (Out going)
MCCB 40 Amp, 4 Pole 50 Hz, 415 V, 16KA with rupturing capacity, Thermal megnatic relay adjustable type – 01 No (For capacitor Bank)
MCB 6 Amp, 2 Pole, 10 KA rating suitable for 230 Volts, C curve – 01 No (spare )
Capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 V 50 Hz system for permissible non-linear load of 25 KVAR capacity, 04 Step (02 x 10 KVAR + 01 x 03 KVAR + 01 x 02 KVAR) including suitable capacity of capacitive duty contactor and incoming MCB etc complete all as per design of panel manufacturer.
LED Indicated Lamp (R,Y,B) one Set-01
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Lamp holder with LED lamp of 5W with toggle switch - 01 No
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication. (iii) Panel shall be suitable for minimum breaking capacity of 65 KA.
Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 65 protection made out of CRCA sheet 3.15 mm thick powder coated with seven tank process, fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with copper bus bar capacity 150 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40x40x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 100 Amp, 4 Pole 50 Hz, 415 V, 16KA with rupturing capacity, Thermal megnatic relay adjustable type – 01 No (incoming)
MCCB 40 Amp, 4 Pole 50 Hz, 415 V, 16KA with rupturing capacity, Thermal megnatic relay adjustable type – 03 Nos (Out going)
MCB 16 Amp, 4 Pole, 10 KA rating suitable for 230 Volts, C curve – 01 No (outgoing )
MCB 6 Amp, 2 Pole, 10 KA rating suitable for 230 Volts, C curve – 01 No (spare )
LED Indicated Lamp (R,Y,B) one Set-01
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Lamp holder with LED lamp of 5W with toggle switch - 01 No
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication. (iii) Panel shall be suitable for minimum breaking capacity of 65 KA.
Supply and fixing energy efficient LED street light fitting of 36W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 5 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply & fixing polycarbonate with glass fibre reinforced internally embedded gasket of polyurethane junction box having IP65 protection of size 250 x 200 X 100 mm fixed to pole with SS 304 clamps and nuts bolts, having provision of single phase aluminium bus bar and MCB 1 to 6 Amp SPN, complete all as specified and as directed.
Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 3x 1.5sqmm 1100 volt drawn through LT steel tubular poles for connection to street light from junction box complete all as specified and as directed.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI medium grade pipe upto test point or upto main switch board or metallic bodies of HT/LT equipments/electric equipment, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) including taking out/dismantling old unserviceable earthing system complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. (iv) Qty 09 Nos for Sch 'A' Sec - II (Part-II) (INTERNAl ELECTRIFICATION WORK) and Qty 04 Nos for Sch 'A' Sec - VIII (Part-II) (EXTERNAL ELECTRIFICATION WORK)
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32 mm x 6 mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI medium grade pipe upto test point or upto main switch board or metallic bodies of HT/LT equipments/electric equipment, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) including taking out/dismantling old unserviceable earthing system complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and labour for bracket (for fixing street light) made out of GI tubing light grade 40mm dia, 1.5 metre long bent to shape at 105 degree angle at half metre from bottom, including three Nos clamp made out of MS Flat iron size 40x5 mm and MS bolt (12mm x 50mm) for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “SUMMER APPLIANCES AND HOT WATER SUPPLY WORK" as listed in Schedule ‘A’ Section - IX (Part-I)
Sch 'A' Sec - IX (Part-II), (SUMMER APPLIANCES AND HOT WATER SUPPLY WORK)
Supply and installation Frost free inverter based Double door refrigerator electric driven single phase 230 volts, AC 50 Hz,of capacity minimum 400 Ltr or next available capacity with BEE approved, minium 3 star rating complete including electric connection complete all as specified and as directed.
Supply and installation Water cooler fully stainless steel, electric driven single phase having storage capacity 120 litre and nominal cooling capacity 60 litre per hour mounted on locatiion as directed, including float valve and connecting and making electric connection complete all as specified and as directed. Note :- PVC water connection shall be measured and paid separately under appropriate item of BOQ/Sch.
Supply and installation Water cooler fully stainless steel, electric driven single phase having storage capacity 180 litre and nominal cooling capacity 150 litre per hour mounted on locatiion as directed, including float valve and connecting and making electric connection complete all as specified and as directed. Note :- PVC water connection shall be measured and paid separately under appropriate item of BOQ/Sch.
Supply and installation Desert Cooler of size 26 x 26 x 33 inch having nominal air flow capacity 4000 cubic metre per hour single phase 240 volts 50 hz made out of plain GI sheet 18 SWG & side panels of 22 SWG , including water pump and float valve, fixed on directed location, and connecting and making electric connection complete all as specified and as directed. Note :- PVC water connection shall be measured and paid separately under appropriate item of BOQ/Sch.
Supply & installation of voltage stabilizer of capacity 2 KVA for automatic operation, single phase naturally air cooled indoor type & Design for input voltage variation between 170V to 250 V with output voltage stabilizer at 230 v with accuracy of +/- 2.5% complete as specified and as directed.
Supply and fixing electric water heater (Geyser, vertical type) storage type ABS body of capacity 25 Ltrs, 5 Star rating, 230V, single phase AC supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with Hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece, PVC connection for hot and cold water, three core PVC Insulated PVC Sheathed copper conductor flexible cable and fixing with 04 No Nut bolts etc. Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- PVC water connection shall be measured and paid separately under appropriate item of BOQ/Sch.
Supply and fixing electric water heater (Geyser, vertical type) storage type ABS body of capacity 50 Ltrs, 5 Star rating, 230V, single phase AC supply, inner tank made out of heavy duty stainless steel sheet (designed with single weld line, factory tested with Hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece, PVC connection for hot and cold water, three core PVC Insulated PVC Sheathed copper conductor flexible cable and fixing with 04 No Nut bolts etc. Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- PVC water connection shall be measured and paid separately under appropriate item of BOQ/Sch.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC Box, Industrial Type) with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and as directed.
Supply and fixing angle valve cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Subtotal
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORK" as listed in Schedule ‘A’ Section - X
BANSI BUILDER AND CONTRACTORS PVT LTD
JB Infrastructure
SACKSON ENTERPRISES
M/s MAKHAN ENTERPRISES
M/s Kataria Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .