Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | First₹9.2 LAccepted-AOC | First | Accepted-AOC First Lowest | |
| 2 | 2nd₹9.3 LRejected-AOC ZIRAKPUR PUNJAB | 2nd | Rejected-AOC Second Lowest |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
10 Oct 2023, 11:00 amClosed
Managing Director
Police Complex, Phase-VII, SAS Nagar.
Supply, Installation, Testing and Commissioning of Electrical Panel in New District Jail, Nabha.
2023_DHA_109681_1
11/2023-24
Open Tender
Electrical Works
Item Rate
60 days
Nabha
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹19,000
Yes
17 Nov 2023
25 Sept 2023
11 Oct 2023
25 Sept 2023
10 Oct 2023
25 Sept 2023
Amount
MAIN MV & APFC CAPACITOR PANEL 180 KVAR
MAIN MV PANEL
Supply, installation, testing and commissioning of powder coated of Siemens grey or of approved colour compartmentlised cubicle extendable type MV Panel fabricated out of 14/16 SWG thick CRCA sheet steel and suitable for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply . The panel shalll be indoor free standing, floor mounting, dust and vermin proof type, gland plates, lifting hooks, ventillating louvers, busbars 1000A (Horizontal/Vertical), Solid Inter connections (Terminal blocks are not acceptable), CT's, edequate space for fixing of ACB's & MCCB's, complete with spreader links, Extended RHOM, labelling, suitable for termination of cables as per single line diagram including following switchgear and accessories complete as required. A separate earth aluminium bus bar to be provided throughout the length of the panel. All incomers should have Digital multi function meters, RYB & On/Off LED indicators lamps and all outgoing feeders should have On/Off LED indicators lamps and complete in all respects as per SLD and to the entire satisfaction of Engineer-in-charge.The panel builder should have CPRI test certificate breaking capacity 50 KA.
A) NORMAL SUPPLY:-
INCOMING FEEDER:-
800Amp. 4 pole Air Circuit Breaker 50KA, MDO MP Release having protection against O/L, S/C & EF with current display
OUTGOINGS:-
MCCB 400A 4P 36KA TMR with O/L & S/C Protection= 01 No.
MCCB 315A 4P36KA TMR with O/L & S/C Protection= 01 No.
MCCB 100A 4P 25KA TMR with O/L & S/C Protection= 3 Nos.
MCCB 63A 4P 25KA TMR with O/L & S/C Protection= 01 No.
B) EMERGENCY SUPPLY:-
INCOMING FEEDERS:-
MCCB 200A 4P 36KA TMR with O/L & S/C Protection =1 No
Motorised Change Over Switch 250 Amp, Four ploe=1 No.
OUTGOINGS:-
MCCB 63A 4P 25KA TMR with O/L & S/C Protection= 03 Nos.
MCCB 100A 4P 25KA TMR with O/L & S/C Protection= 04 Nos.
C) APFC CAPACITOR PANEL: 180 KVAR
a) INCOMING FEEDER
MCCB 315A 4P36KA TMR with O/L & S/C Protection= 01 No.
b) OUT- GOING FEEDER'S
(Complete as above):(NS)
HT & LT LINE ITEMS:
Supply & erection of 11kV GO switch confirming to ISI specifications. The item includes supply and erection of operating pipe and handle arrangement of MS flat 50mm x 6mm and channels 75mm x 40mm sheet. The GO switch is to be fitted with locking arrangement so as it locks upward on 'ON' position and locks downward in 'OFF' position. The entire GO switch assembly/unit should be properly earthed and the job is to be completed as approved by Engineer-in-charge.CSR:34.38(VII)
COPPER EARTHING:(Upto 8 metre in Length):
Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 25mm x 3mm Copper Tape (upto 8Metre in Length)CSR:34.14 (II) B
COPPER EARTHING STRIP (As Additional Length):
Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-
Additional Length 25mmx3mm thick Copper Tape CSR:CSR:34.14 (v) B
Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.
4.5 Kg. Capacity CSR:28.125C
Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.
4 Kg. Capacity CSR:28.124b
Supply and Erection of Rubber Mat of size 2m x 1m x 2.5mm suitable for 11 KV (ISI Marked) complete in all respect.NS
Less Buy back value of old Panels( The bidder has to offere the buy back value of existing old panels)
MANOJ KUMAR GUPTA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .