| Sl No | Description | Qty | Unit | AMIT ASSOCIATES L2 | M/s Dhapola Elevator and Engineering L3 | Evaan Elevators Pvt. Ltd L1 |
|---|---|---|---|---|---|---|
| 1.00 | LIFT 1 at Facilitation Centre, CB Office, Delhi Cantt Supplying, Installation, Testing and Commissioning of 6 Passenger Lift (408 kgs or more) lifts having contract speed of 0.4 MPS (G+1) serving different floors in the lift shaft as per detailed specification enclosed and as under: | 1 | Job | 18,50,000 ₹18,50,000 | 22,00,000 ₹22,00,000 | 17,45,950 ₹17,45,950 Lowest |
| 1.10Type of machine-Machine room less (MRL) less type & permanent magnet gearless motor. Type of lift 6 Passenger, MS Load : min. 408 kgs Speed : 0.4 m/s Floors: 2 (G+1 Upper Floors) No of Floors : Ground +1 Upper Floor Stops & Openings: 2 Stops (0, 1) - as per site requirement Controller - A.C. Variable voltage & Variable frequency (VVVF) Automatic rescue device with dry maintenance free battery of required capacity. Power 415Volts + 10%, 3Phase ,50 Hz AC. Car: Power operated - Centre opening sliding doors made of stainless steel with glass door | ||||||
| 1.20Landing Doors & door frame - power operated - Centre opening sliding doors & door frame shall be Stainless steel glass door finish. Landing doors shall have a fire resistance of 2 hr. Lift car ceiling: It shall have a small circular LED-lights & Regular Fan. Ceiling shall be of Stainless Steel mirror finish. Flooring:- Granite superior quality in design and pattern as approve by the Engineer-in-charge. Lift shall have all the features as per Accessible India Norms updated till date and shall be installed in compliance with the norms. Braile system push buttons of minimum dimensions of 20mm with height of the letter size 15mm including all facilities for physically challenged persons. Voice announcement system in the car to announce the position of the elevator in the hoistway as car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS:14665 and as amended upto date. Note:- 1) Voice announcement shall be operative during operation of ARD also. 2) During ARD operation lights/ emergency light and fan shall be in working condition. If required separate inverter should be provided for which nothing extra shall be paid. | ||||||
| 1.30GI boxes for control buttons shall be provided at height of 800 to 1000 mm from ground level in all landings. Call buttons shall be provided at height as recommended by OEM 1 No. Car operating panels shall be provided - one on each side of the car door inside the lift at a height as recommended by OEM Audio visual over load indicator Fireman switch at ground floor.2 way 3 station inter communication system / Telephone system. 5 mm thick, mirror 1000 mm x 800 mm. on rear panel inside the car LED fittings with necessary lux level as per NBC 2016 and noise free ventilation fan inside lift car Granite flooring inside Lift car Digital position indicators (in car and at all landings) RS 485 Module for BMS Integration All civil works realted to successful installations of lifts including scaffolding, fixing of MS frames, channels, weights etc, Scaffolding lift shaft lighting and controls as per specifications. Automatic shut off fan to be provided battery operated Emergency light and alarm bell to be provided | ||||||
| 2.00 | LIFT 2 at Cantonment General Hospital, Delhi Cantt
Supplying, Installation, Testing and Commissioning of 20 Passenger Lift (1360 kgs or more) (G+2) lifts having contract speed of 1.0 MPS serving different floors in the lift shaft as per detailed specification enclosed and as under: | 1 | Job | 26,45,000 ₹26,45,000 | 23,00,000 ₹23,00,000 Lowest | 25,95,000 ₹25,95,000 |
| 2.10Type of machine-Machine room Less & permanent magnet synchronize motor. Type of lift 20 Passengers Load :1360 kgs or more Speed : 1.0 m/s Floors: 3 (G+2 Upper Floors) Travel : 14 metres (approx.) No of Floors : Ground +2 Upper Floors Stops & Openings: 3 Stops (0, 1, 2) - 3 openings same side Controller - A.C. Variable voltage & Variable frequency (VVVF) Automatic rescue device with dry maintenance free battery of required capacity. Power 415Volts + 10%, 3Phase ,50 Hz AC. Type of Doors:- Car: Power operated - Centre opening sliding glass doors made of Stainless steel Hairline Finish. | ||||||
| 2.20Landing Doors & door frame - power operated - Centre opening sliding doors & door frame shall be Stainless steel glass door. Landing doors shall have a fire resistance of 2 hr. Lift car ceiling: It shall have a small circular LED-lights & Regular Fan. Ceiling shall be of Stainless Steel mirror finish. Flooring:- Granite superior quality in design and pattern as approve by the Engineer-in-charge. Lift shall have all the features as per Accessible India Norms updated till date and shall be installed in compliance with the norms. Braile system push buttons of minimum dimensions of 20mm with height of the letter size 15mm including all facilities for physically challenged persons. Voice announcement system in the car to announce the position of the elevator in the hoistway as car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS:14665 and as amended upto date. Note:- 1) Voice announcement shall be operative during operation of ARD also. 2) During ARD operation lights/ emergency light and fan shall be in working condition. If required separate inverter should be provided for which nothing extra shall be paid. | ||||||
| 2.30GI boxes for control buttons shall be provided at height of 800 to 1000 mm from ground level in all landings. Call buttons shall be provided at height as recommended by OEM COP: 1 Nos Car operating panels shall be provided in the lift.at a height as recommended by OEM Audio visual over load indicator Fireman switch at ground floor 2 way 3 station inter communication system / Telephone system. LED fittings with necessary lux level as per NBC 2016 and noise free ventilation fan inside lift car Granite flooring inside Lift car Digital position indicators (in car and at all landings) RS 485 Module for BMS Integration All civil works related to successful installations of lifts including scaffolding, fixing of MS frames, channels, weights etc, Scaffolding lift shaft lighting and controls as per specifications. Automatic shut off fan to be provided battery operated Emergency light and alarm bell to be provided | ||||||
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
4 Aug 2026, 1:00 pmClosed
Chief Executive Officer
Chief Executive Officer, Delhi Cantonment Board, 110010
Provision of Lift in Facilitation Centre of Cantonment Board Office, CG Hospital, Delhi Cantt.
2026_DGDE_777882_1
DCB/8/C-36/EandM/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
Delhi Cantonment Board
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Chief Executive Officer, Delhi Cantonment Board
₹99,000
17 Aug 2026
11 Jul 2026
5 Aug 2026
11 Jul 2026
4 Aug 2026
11 Jul 2026
11 Jul 2026 - 4 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1LIFT 1 at Facilitation Centre, CB Office, Delhi Cantt Supplying, Installation, Testing and Commissioning of 6 Passenger Lift (408 kgs or more) lifts having contract speed of 0.4 MPS (G+1) serving different floors in the lift shaft as per detailed specification enclosed and as under: | |||||
| 1.1 | Type of machine-Machine room less (MRL)
less type & permanent magnet gearless motor.
Type of lift 6 Passenger, MS
Load : min. 408 kgs
Speed : 0.4 m/s
Floors: 2 (G+1 Upper Floors)
No of Floors : Ground +1 Upper Floor
Stops & Openings: 2 Stops (0, 1) - as per site requirement
Controller - A.C. Variable voltage & Variable frequency (VVVF)
Automatic rescue device with dry maintenance free battery of
required capacity.
Power 415Volts + 10%, 3Phase ,50 Hz AC.
Car: Power operated - Centre opening sliding doors made of stainless steel with glass door | - | - | - | - |
| 1.2 | Landing Doors & door frame - power operated - Centre opening sliding doors & door frame shall be Stainless steel glass door finish. Landing doors shall have a fire resistance of 2 hr.
Lift car ceiling: It shall have a small circular LED-lights & Regular Fan. Ceiling shall be of Stainless Steel mirror finish.
Flooring:- Granite superior quality in design and pattern as approve by the Engineer-in-charge.
Lift shall have all the features as per Accessible India Norms updated till date and shall be installed in compliance with the norms.
Braile system push buttons of minimum dimensions of 20mm with height of the letter size 15mm including all facilities for physically challenged persons.
Voice announcement system in the car to announce the position of the elevator in the hoistway as car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS:14665 and as amended upto date.
Note:- 1) Voice announcement shall be operative during operation of ARD also.
2) During ARD operation lights/ emergency light and fan shall be in working condition. If required separate inverter should be provided for which nothing extra shall be paid. | - | - | - | - |
| 1.3 | GI boxes for control buttons shall be provided at height of 800 to 1000 mm from ground level in all landings.
Call buttons shall be provided at height as recommended by OEM
1 No. Car operating panels shall be provided - one on each side of the car door inside the lift at a height as recommended by OEM
Audio visual over load indicator
Fireman switch at ground floor.2 way 3 station inter communication system / Telephone system. 5 mm thick, mirror 1000 mm x 800 mm. on rear panel inside the car LED fittings with necessary lux level as per NBC 2016 and noise free ventilation fan inside lift car
Granite flooring inside Lift car
Digital position indicators (in car and at all landings)
RS 485 Module for BMS Integration
All civil works realted to successful installations of lifts including scaffolding, fixing of MS frames, channels, weights etc, Scaffolding lift shaft lighting and controls as per specifications.
Automatic shut off fan to be provided battery operated Emergency light and alarm bell to be provided | - | - | - | - |
| 2LIFT 2 at Cantonment General Hospital, Delhi Cantt Supplying, Installation, Testing and Commissioning of 20 Passenger Lift (1360 kgs or more) (G+2) lifts having contract speed of 1.0 MPS serving different floors in the lift shaft as per detailed specification enclosed and as under: | |||||
| 2.1 | Type of machine-Machine room Less & permanent magnet synchronize motor.
Type of lift 20 Passengers
Load :1360 kgs or more
Speed : 1.0 m/s
Floors: 3 (G+2 Upper Floors)
Travel : 14 metres (approx.)
No of Floors : Ground +2 Upper Floors
Stops & Openings: 3 Stops (0, 1, 2) - 3 openings same side
Controller - A.C. Variable voltage & Variable frequency (VVVF)
Automatic rescue device with dry maintenance free battery of
required capacity.
Power 415Volts + 10%, 3Phase ,50 Hz AC.
Type of Doors:-
Car: Power operated - Centre opening sliding glass doors made of Stainless steel Hairline Finish. | - | - | - | - |
| 2.2 | Landing Doors & door frame - power operated - Centre opening sliding doors & door frame shall be Stainless steel glass door. Landing doors shall have a fire resistance of 2 hr.
Lift car ceiling: It shall have a small circular LED-lights & Regular Fan. Ceiling shall be of Stainless Steel mirror finish.
Flooring:- Granite superior quality in design and pattern as approve by the Engineer-in-charge.
Lift shall have all the features as per Accessible India Norms updated till date and shall be installed in compliance with the norms.
Braile system push buttons of minimum dimensions of 20mm with height of the letter size 15mm including all facilities for physically challenged persons.
Voice announcement system in the car to announce the position of the elevator in the hoistway as car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS:14665 and as amended upto date.
Note:- 1) Voice announcement shall be operative during operation of ARD also. 2) During ARD operation lights/ emergency light and fan shall be in working condition. If required separate inverter should be provided for which nothing extra shall be paid. | - | - | - | - |
| 2.3 | GI boxes for control buttons shall be provided at height of 800 to 1000 mm from ground level in all landings.
Call buttons shall be provided at height as recommended by OEM
COP: 1 Nos Car operating panels shall be provided in the lift.at a height as recommended by OEM
Audio visual over load indicator
Fireman switch at ground floor 2 way 3 station inter communication system / Telephone system.
LED fittings with necessary lux level as per NBC 2016 and noise free ventilation fan inside lift car
Granite flooring inside Lift car
Digital position indicators (in car and at all landings) RS 485 Module for BMS Integration
All civil works related to successful installations of lifts including scaffolding, fixing of MS frames, channels, weights etc, Scaffolding lift shaft lighting and controls as per specifications.
Automatic shut off fan to be provided battery operated Emergency light and alarm bell to be provided | - | - | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
office.pdf
Tender Documents • 1.93 MB
BOQ_871201.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .