Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.6 LAccepted-Finance 5 1351 MARKANDEYA NAGAR EAR GAJULARAMARAM ROAD HYDERABAD RANGAREDDI TELANGANA 500055 | MEDCHAL MALKAJGIRI | TELANGANA | 500055 | L-1 | Accepted-Finance L-1 BIDDER | |
| 2 | L-2₹1.7 L+₹12,770 (8.01%)Accepted-Finance | L-2 | Accepted-Finance L-2 BIDDER |
Tender Value
₹1.8 L
EMD Value
₹3,596
Closing Date
13 Feb 2025, 11:30 amClosed
EE(EP-MM)
O/o Sr. Chief Engineer (Electrical) BSNL Electrical Zone, Room no- 601, 6th Floor, BSNL Bhavan, Adarsh Nagar, Hyderabad
Providing maintenance of electromechanical equipments EI and fans, Air conditioner units, EA set, Public addressing system, Projectors, Air coolers , Pumps and Sub-station Emergency maintenance at DS Bhavan, Hyd SH EI and Fans Mtce
2025_BSNL_225892_1
24 /EE(EP-MM)/BEZH/2024-25 dated 05.02.2025
Open Tender
Electrical Works
Item Rate
180 days
Hyderabad
Please refer Tender documents.
13 documents required · 13 mandatory
₹590
AO Cash, BSNL, CGMT office Hyderabad
₹3,596
7 Apr 2025
5 Feb 2025
14 Feb 2025
5 Feb 2025
13 Feb 2025
5 Feb 2025
5 Feb 2025 - 11 Feb 2025
Amount
Supplying and Drawing the following size FRLS PVC insulated copper conductor cable in the existing PVC/MS conduit/PVC casing and capping etc., as reqd. a) 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
b) 4 x 1.5 Sq.mm + 2 x 1.5 Sq.mm earth wire
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire
c) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Re-wiring for light point/ exhaust point/ call point with 1.5Sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with piano type switch phenolic laminated sheet suitable size MS box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc., as required. a) Group C
Providing and fixing following sizes medium class PVC conduit on surface for wiring etc., as required. a) 20mm
Supplying and fixing of the following accessories suitable for operation on 230V, 50Hz AC supply including making connections and removing of faulty items as required. a) 2.5mfd Ceiling Fan capacitors
b) Fan regulators Step type/dimmer Socket type
c) 5/6 Amps piano type switch.
d) 3 pin 5/6 Amps socket outlet
e) 3 pin 15 Amps socket,
f)15/16 Amps piano type switch
g) 3 pin 15 Amps Piano type socket with 15A Piano switch
h) 4 feet 18/20W LED tube
i) Calling Bell (Ding Dong)
j) Wireless Calling Bell
Supplying and fixing following size modules, PVC box along with modular base & cover plate for modular switches in recess etc. as required. (for UPS Boards ) a) 12 Module
b) 18 Module
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(for UPS Boards) a) 5/6 amps switch
b) 3 pin 5/6 amp socket outlet
Attending of emergency breakdown call rectifying of fault, restoration of power supply in LT panel/DB and making temporary connections wherever necessary etc.,complete as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit up to 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Removing and re-fixing of existing ceiling fan including wiring the down rods of standard length (up to 30 cm) with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable including providing and fixing of fan hook etc., as required.
Installation testing and commissioning of old recovered UPS Power switch boards fixing on the existing wall / partition including making good etc., complete as required.
Repairing & rewinding of ceiling fan including replacing of fan bearings, fan capacitor and general servicing, i/c Transporting to work shop and again bring back to O/o CGMT, re-fixing, testing etc., as required.
Providing repairs to compound lights byreplacement of following items i/c removingthe faulty and interconnections etc., as required. (Back side of DSB Bldg) a) 30W LED street light fitting
b) 2Core 6Sq.mm weather proof wire along with 14SWG GI wire
d) S/F of 25mm dia GI bracketfor mounting the LED type fitting i/c fixing the bracket on the surface of wall etc., as required.
Supplying and fixing of 26W LED Bulbs suitable for B22 base and also suitable for 230V,50 HZ AC supply etc.,as required.(for Gate lights)
Removing and re-fixing of Glow sign Board of size 5'x1.5' by replacing " BSNL logo" with new "BSNL Logo" and " Telangana Circle " for fixing at CGM Chamber and Conference hall by replacing with 3mm thick Aluminium composite panel sheet, 3mm LASER cutting Acrylic letters on existing MS frame work of size 2"x1" MS frame work excluding 200 Watts LED Driver and covering the back side with flexy material complete etc., as required.
Supplying and fixing of 1x20W Box type Batten Lumnarie along with Supplying and fixing of 1no T8 20W LED tube suitable for 230V,50HZ,1ph AC supply i/c removing the faulty,interconnections etc.,complete as required.
V S ELECTRICAL WORKS (BID ID -817615)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .