| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 LAccepted-AOC NO 2 16 KANGAYAMPALAYAM SULFUR PO COIMBATORE 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹50.0 L+₹61,414 (1.24%)Rejected-Finance DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹51.0 L+₹1.7 L (3.39%)Rejected-Finance 121004 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹52.2 L+₹2.8 L (5.69%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹52.8 L+₹3.4 L (6.93%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
4 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR TO CERTAIN CONNECTED WAYS HARDSTANDING PATH AND OTHER MISC ITEMS AT AF STN SULUR
2021_MES_440121_1
8393/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹99,000
Yes
8 Jun 2021
3 May 2021
5 Jun 2021
3 May 2021
4 Jun 2021
17 May 2021
3 May 2021 - 15 May 2021
60 days
Amount
SCHEDULE A BOQ
Dismantling the disturbed/ broken/ rusted wrought iron or mild steel work in FOD TRAP of any description not other wise provided for and refixing after repairs for making good position by tightening/ welding etc all as directed. Note :- Additional required mild steel shall be measured and paid separately as supply only. However, labour element for fabrication, erection,fixing and welding, with ends of bars shouldered and/ or riveted all as directed by Engineer-in-Charge. is deemed to be included in this item.
Supply only framed work such as gratings, angles or tees, beam, channel with web and flanges etc for FOD TRAP all as directed.
M&L PCC 1:1½:3 type A-1 (using 20 mm graded stone aggregate) as in foundation, filling, posts, bed blocks and similar works with necessary form work including demolition of existing concrete all as specified.
M&L for granolithic concrete 1:1:2 floor topping 30 mm thick laid over cement concrete sub floors etc finished to and even and fair surfaces all as specified and as directed.
Demolition of brickwork built in cement mortar ,including all quoins, arches, pillars etc but excluding ashlars facing, dressed stone work and pre-cast concrete articles stone/ boulder masonry built in cement mortar.
M&L Brick work with fly ash brick straight or curved on plan exc 6 m radius built in CM 1:6 complete all as specified and directed by Engineer in charge.
M&L Rendering 15 mm thick in two layers on brick or stone or concrete surfaces with first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note: (a) The unit rates quoted by the tenderer shall be deemed to inclusive for waterproofing compund. (b) The unit rate quoted is deemed to included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
M&L Applying two coats of cement based paint over a coat of primer including prepration of unplastered wall surfaces of any description, complete all as specified and as directed.
Demolition of existing un-reinforced Cement Concrete in ground floors and pavings exceeding 15 cm thickness nut not exceeding 30 cm complete all as specified and directed.
Removal of demolished materials / debris etc. to a distance exceeding 1.5 KM and not exceeding 5 KM and depositing where directed complete all as specified and as directed.
Note for item No 10 & 11 : (i) Removal of demolished material obtained from Sl. item No. 10 upto 1.5 km distance shall deemed to included in the rate quoted for Sl. item No 10 (ii) Removal of demolished material obtained from Sl. item No. 11 beyond 1.5 km shall only be measured and paid under this item.
M&L Pavement Quality Cement Concrete (PQC) work in pavement slab / hard standing, in single layer, using design mix with minimum cement content 400 Kg/Cum to achieve flextural strength 45 Kg/sqcm on 28 days (lower concrete limit LCL) in pavement slabs, spread & compacted using vibrators and paving slip form conrete sensor paver min 4 m wide and Mechanical paver with electronic sensor (minimum 05m wide extendable with attachment to 8m wide to required gradient , using non circular synthetic fiber @ 0.25% by weight of cement, including necessary steel form work along the joints compacting finishing and belting/brooming all as specified and directed.
Note for item No 13 :- (a) Contractor shall consider 400 kg of cement per cum of concrete while quoting this item. Actual quantity of cement shall be used as per approved design mix. No price adjustment shall be applicable for excess quantity of cement content i.e beyond 400 kg as per approved design mix in execution of work. (b) Non circular synthetic fiber shall be mixed in the "PQC" @ 0.25% of cement all as per manufacturers instructions and as directed by Engr-in-charge.
(c) Supply only of POLYESTER TRIANGULAR/non circular synthetic fibre shall be measured and paid seperately. (d) Cost of steel formwork and testing as specified shall be deemed to included in the rate quoted by the tenderer. (e) Maximum working temperature shall not exceed 30 degree centigrade of atmosphere.
Supply only polyester triangular/Non circular synthetic fibre for pavement quality concrete PQC surface complete all as specified and directed.
M&L Dry lean concrete of compressive strength not less than 10 Mpa at 7 days with minimum 150 Kg of cement/cum using design mix laid and rolled with double drum smooth wheeled vibratory roller of 8 to 10 Ton capacity complete including demolition of concrete and removing to out side MD land all as specified and directed.
M&L 10mm thick manufacturing sand cushion as inter face layer below the PQC including watering and consolidation Spreading and levelling in layers n exc. 25 cm thick
Supply and laying one layer of polythene film (transparent colour) 400 micron thickness as per ASTM D2103/IS 2508 laid sand cushion with side and end overlapping not less than 300mm all as approved by GE. Note :- (i) Measurement shall be taken for net area and unit rate quoted shall deemed to include for over lapping.
Levelling of road side berm by filling, spreading with existing sand/Moorum at lower area and cutting at raise area with the mechanical machine and rolling of surface with road roller of capacity 8-10 tonne, including removal of extra cutting material ,boulders and other materials from area and all as specified and directed. Note :- The unit rates quoted by the tenderer shall be deemed to inclusive for (i) The work in cutting and filling shall be carried out as instructed by the Engineer-in-Charge. (ii) Black cotton soil/ vegetable soils and soils obtained from top 30 cm cutting shall not be used for filling and shall be disposed off as directed by Engineer-in-Charge. (iii) Boulders or rock materials if encountered in cut slopes shall be excavated to the approved depth as directed and the resulting cavities with suitable material and thoroughly compacted as directed. (iv) Cutting and filling shall be cleared of shurbs, vegetation, grass, bush, weed, trees and saplings not exceeding 30 cm in girth, measured at a height of one metre above ground level.
M&L Renewing cement concrete tiles in patches, area n exc 5 sq.m. Including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete all as directed. Note : The rate included for cutting out broken tiles, removing and cleaning loose tiles, preparing bed removing rubbish and replaing old with new tiles to match, complete with all cuttings etc, that may be required. New tiles required is deemed to be included all as directed. The unit rate is also including necessary bedding in cement mortar.
S&F Cat eye made of ABS body with scratch and abrasion resistant micro prismatic polycarbonate and ultrasonically welded lens. Temperature resistant body and lens (90X110X17mm) colour white/ red/ yellow fixing to road by using bitumen or epoxy etc complete including taking down existing one all as specified and as directed. (Make: 3M /Simsonite / Tata BP)
M&L Bituminous Premixed Semi dense asphaltic Concrete, 30 mm consolidated thickness, using paving bitumen of Grade VG – 30, with 5.5% binder content by weight of total mix using paving bitumen, rolled and compacted ro required camber and gradient using Hot Mix Plant and Mechanical Paver, rolled and compacted with power road roller of 8 to 12 ton capacity to required camber and gradient including demolition of existing damaged SDAC complete all as specified and directed.
Note for item No 23:- (i) The actual binder content for SDAC used shall be as per optimised content based on approved job mix formula irrespective of what ever indicated in BOQ. (ii) Price adjustment shall be done on MINUS side only based on paid vocher (without considering the permissible tolerance on minus side) with reference to binder content indicated in BOQ. (iii) No prices adjustment for Bitumen shall be done for variation on plus side.
M&L repair to pot holes any depth, not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting round edges to at least 25 mm in depth, making good by filling in screened & graded road metal, watering and well ramming (including supply of road metal) including taking up existing disturbed portion of hard core removing and deposting the same where directed by enginer in charge
M&L precast kerb stone as in PCC 1:3:6 type C1 using 20 mm graded stone aggregate and set in CM 1:4 including removing the old damaged kerb stone from the site and deposit out side MD land where directed etc including making good the disturbed portion of road or path complete all as specified and as directed. Note :- The unit rate is deemed to be included for (a) Demolition of concrete and removing rubish material to out side MD land. (b) Necessary form work.
M&L 75 mm thick , Moorum/ red bajri filling in road side berms, laid in layers n exc. 15 cm thick, spread, levelled and rammed/ rolled including watering to required level and gradient complete all as specified and as directed. Note: (i) Moorum/red bajri required shall be brought from outside MD land (ii) Compaction of moorum filling shall be carried out under optimum moisture conditions up to the standard proctor density not less than 98 percent. (iii) Measurements shall be taken after consolidation earth and 5% deduction shall be made for payments.
Material obtained from demolished materials / debris etc. of PQC deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface including demolition of existing undulated hardcore surface and removing the same complete all as specified and directed.
M&L Machine pressed rubber moulded precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 60mm thickness M-40 grade, laid over and including M sand cushion of 50mm thick complete and packing the sides with PCC 1:3:6 type C1 using 20 mm graded stone aggregates all as specified and directed. Note : (a) The Unit rate quoted is included for Demolition of Stone Slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar. (b) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to procurement.
M&L preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surfaces with gunny bags or using air compressor to remove all loose dirt etc to remove all dirt etc. and applying evenly a priming / tack coat with bituminous primer VG-10 at the rate of 2.5 KG per 10 Sq.m complete all as specified and directed.
S&F of protection roadway plastic road studs photoluminicent high visible (Glow in the dark) all weather proof road stud of 100mm x 100mm x 20mm size with orange reflectors with load bearing capacity of 16 tons and minimum glowing period 8 hours without any battery requirement fixed on existing road including taking down existing one with approved adhesive all as per manufacturer's instructions and as directed. Make :- M/s Srijan system Pvt Ltd/ Audo Viso/ Tata BP
S&F speed bump (SB-01) made out of plastic material with a provision of two highly reflective reflectors moulded in PMMA material welded with ABS base plate through ultrasonic welding process and then fixed on speed bump to safeguard reflectors inside area. Metalic bolts are used for installation on road of size L=250mm, W=750mm, H=75mm) including taking down and removing rubbish material to outside MD land complete all as specified and directed.
M&L providing 100mm thick plain cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in sub base to tiles complete including demolition of concrete and removing rubish material to out side MD land all as specified and directed .
M&L chequered cement concrete coloured tiles 300 x 300 x 25 mm thick/ 400 x 400 x 25 mm thick machine pressed heavy duty any pattern/type, chemically treated set jointed and pointed in neat cement slurry as in paths, etc and cut and polished using grey cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:6) complete all as specified. Note : (a) The Unit rate quoted is inclusive for Demolition of Stone Slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar (b) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
Supply and fixing madatory sign board of 600mm dia (with message plate) made out of 3mm thick ACP (Aluminum Composite Pannel) sheet framed with 25mm square pipe with base white and red boardedr and symbol in black colour tape (as per drawing). Back side in grey stove enameld paint including one MS pipe post of 50mm square pipe 3.0mtr long duly painted with alternate black and white bandsof 25cm width including excavating post holes of 30 x 30 x 30 cm and embedded in PCC 1:3:6 and including taking down and removing rubbish material to outside MD land as per direction of Engineer-in-Charge.
M&L 100mm thick, plain cement concrete (1:2:4), type B-1 (using 20 mm graded mechanically crushed stone aggregates), as in hardstanding including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, including demolition of existing concrete and removal of debris out of MD land complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
Taking down and refixing the same steel gate not exc 3 sqm each pane after repair of rusted or damaged portion of the gate including pivote, holdfast, stopper, locking arrangement, pintal etc and necessary greasing to pivote with or including spot welding, running welding all as specified. Note :- In case required new mild steel fixed with replacing rusted or damaged portion will be included in quoted rate.
Taking down and refixing broken glass coping on top of wall in CM 1:3 complete all as specified and as directed. Note :-Contractor shall bring broken glass from out side MD land 25mm layer of cement mortar (1:3) with broken glass @ of 10 Kg per Sqm in case sufficient glass not obtained from taking down and the quoted rate is deemed to be inclusive of this provision also.
M&L forming construction joint, 25mm deep and 8 mm wide in repairs (using diamond cutter), applying one coat of white wash to the exposed vertical faces of slab, providing polyethylene rod 10mm dia and sealed with Polyurethane sealant (Minimum depth above polyethylene rod shall be of 10 mm) complying with BS: 5212 (For type 'FB' fire & fuel resistance) & BS : 4254 and EN-141875 - 2003 (For hydrolysis / water resistance test), priming the sides, minimum movement accommodation factor (MAF)±30% with ten years performance guarantee) and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surfaces to give neat finish to the sealant and removing the masking tape after sealant is applied by mechanical means complete all as specified and directed.
M&L forming contraction (Dummy) joints, cutting with diamond cutter to a depth of 100 mm and 3mm wide in repairs initially and top 25mm portion cut to 8mm wide to accommodate polyethylene rod 8mm wide and sealant, provision of closed cell polyethylene rod of 10 mm dia sealed with (10mm depth minimum above polyethylene rod) polyeurethane sealant complying with BS 5212 (For type 'FB' fire & fuel resistance) & BS 4254 and EN-141875 - 2003 (For hydrolysis / water resistance test) priming the sides with two coats and with minimum MAF ± 30% (with ten years performance guarantee) and applying masking tape on edges of joint to prevent accidental spillage of sealant on top surfaces to give neat finish to the sealant and removing masking tape after the application of sealant by mechanical means all as specified and directed.
M&L forming 25 mm thick expansion joint, filled with compressible synthetic filler board, on top of filler board for complete width of joint, provision of closed cell polyethylene rod 30 mm dia, filled with polyurethane sealant (Minimum depth above polyethylene rod shall be of 10 mm) complying with BS-5212 (For type 'FB' fire & fuel resistance) & BS-4254, and EN - 141875 - 2003 (for hydrolysis / water resistance test) priming the sides, with minimum MAF ±30 % (with ten years performance guarantee) and applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after sealant is applied by mechanical means in repairs all as specified and directed.
PRIYA ENTERPRISES
Neptune Engineers and Builders
GOVINDAN KUTTY and CO
A.GOVINDARAJ
p.chinnasamy
CAK Enterprises
N SARAVANAN
SUPER COOL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .