| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 CrAccepted-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹10.3 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹11.1 CrRejected-AOC K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹11.1 Cr | L2 | Rejected-AOC Other than Lowest |
| 3 | L3₹11.6 CrRejected-AOC 908 9TH FLOOR VENUS ATLANTIS CORPORATE PARK ANANDNAGAR PRAHALADNAGAR AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | ₹11.6 Cr | L3 | Rejected-AOC Other than Lowest |
| 4 | L4₹11.6 CrRejected-AOC | ₹11.6 Cr | L4 | Rejected-AOC Other than Lowest |
| 5 | L5₹12.0 CrRejected-AOC 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹12.0 Cr | L5 | Rejected-AOC Other than Lowest |
Tender Value
₹13.2 Cr
EMD Value
₹9.5 L
Closing Date
27 Jan 2024, 6:00 pmClosed
CE Chandigarh Zone
HQ CE Chandigarh Zone N Area, Airport Road Chandigarh-160003
CA NO CE CHZ CHM T13 2023 24 IMMEDIATE RESTORATION OF EXISTING 10 NOS OF OPERATION THEATRES AND 16 BEDDED INTENSIVE CARE UNIT ESSENTIAL WORK AREAS TO LAID DOWN MEDICAL PROTOCOLS GUIDELINES AS A LIFE SAVING MEASURE AT COMMAND HOSPITAL CHANDIMANDIR
2023_MES_629006_1
CE CHZ/CHM/T-13/2023-24
Open Tender
Electrical and Maintenance Works
300 days
Chandimandir
As per Tender Documents
9 documents required · 9 mandatory
₹3,000
Yes
GE U CHANDIMANDIR
₹9.5 L
Yes
23 Mar 2024
23 Nov 2023
29 Jan 2024
23 Nov 2023
27 Jan 2024
15 Jan 2024
23 Nov 2023 - 13 Dec 2023
Amount
OT UPGRADE
(a) Wall panel / Cladding : Material and labour for pre fabricated wall panelling made of Stainless Steel 304 Grade with 50 to 60mm thick puff insulation with pressure injected of rigid polyurethane foam minimum density 40kg /cum,sandwiched between inner and outer stainless steel sheeting having 0.80mm thickness.The wall panels to be fixed on metal Grid frame work sufficient enough to withstand the entire wall panelling work including making / cutting necessary opening if any required as per site conditions for fixing switch boards / gas pipeline/ electrification works and equipment etc. (b) Joints. The individual wall panel shall use the tongue and groove / suitable technology for joining two panels with minimum number of junctions. No welding shall be allowed. The gaps between Wall Panels to be filled with metalic epoxy filler and sanded flush giving seamless appearance and finished to fine grain surface to the entire wall panelling.The angular corners to be made with 130 degree - 140 degree angular modular element. (c) Anti Bacterial Paint : The stainless steel wall Panelling to be painted with dry film thickness of minimum 300microns over primer. The paint to be Anti-bacterial , Anti-microbial & Antifungal , resistant to UV lights, disinfactants ,steams, fumigation agents etc.Painting to be applied by approved applicator with air-less spray gun.Color and tint of paint to be approved by the User. the painting protection and preventation of the growth of mould,bacteria and yeasts for 5 years be given by the manufacturer.The wall Panels shall be CE/UL/ETL/US FDA/BIS/DIN 1.4301 Certified/Listed.Test report from Govt certified lab for anti-microbial , Stainless steel & properties of paint will be submitted by the contractor at the time of Pre-Dispatch inspection/supply by CWE's Rep. Note : Wall panelling to be provided flushed with storage cabinet / space side and size of grid for wall panelling will be fixed accordingly.
(a) Ceiling Panel :Material and labour for pre fabricated false ceiling panels made of Stainless Steel 304 Grade with injected with rigid polyurethane foam puff insulation of minimum density 40kg /cum,sandwiched between inner and outer stainless steel sheeting having 0.80mm thickness with total thickness of panel 30-40mm.The false ceiling panels to be fixed on metal Grid frame work sufficient enough to withstand the entire false ceiling work including making / cutting necessary opening if any required as per site conditions for fixing any electrification works and equipment etc. (b) Joints: The individual Ceiling panel shall use the tongue and groove / suitable technology for joining two panels with minimum number of junctions. No welding shall be allowed. The gaps between Ceiling Panels to be filled with metalic epoxy filler and sanded flush giving seamless appearance and finished to fine grain surface to the entire Celing panelling.The angular corners to be made with 130 degree - 140 degree angular modular element. (c) Anti Bacterial Paint : The stainless steel Celing Panelling to be painted with dry film thickness of minimum 300 microns over primer. The paint to be Anti-bacterial, Anti-microbial & Antifungal ,resistant to UV lights, disinfactants ,steams, fumigation agents etc.Painting to be applied by approved applicator with air-less spray gun.Color and tint of paint to be approved by the User. the painting protection and preventation of the growth of mould, bacteria and yeasts for 5 years be given by the manufacturer.The Ceilng Panels shall be CE/UL/ETL/US FDA/BIS/DIN 1.4301 Certified/Listed.Test report from Govt certified lab for anti-microbial , Stainless steel & properties of paint will be submitted by the contractor at the time of Pre-Dispatch inspection/supply by CWE's Rep.
Automatic Hermetically Sealed sliding door with electronic automation unit Door : S&F of sliding door made of HPCL / HPL material ( minimum 4mm thickness) painted with anti bactrial paint and lead lining (minimum 1 mm thickness). Thickness of Door to be 50 to 60mm injected with CFC free polyurethane foam Puff insulation having minium density of 40 kg /cum. Colour of door from interior to match the interiors of Room & from outside to match with the outer area.The door should have double glazed vision window size of 300mm x 300mm and hermitically sealed. The Hermetic sealing should confirm to class 4 ( EN 1.026,EN 12.207). Door will move on roller and the movement to be smooth. Either side of door should be perfectly leveled. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential). Air tightness 99.99% at a pressure of 100KPa. Dimension of door will be 1500mm x 2100mm with lead line( as per AERB Norms) or ( size may vary slightly as per site requirement) Complete all as specified and directed. The rates are inclusive of following :- (a) Automation & Hard ware / Accessories :Door to be provided with both touchless sensor based switch button and foot operated switch on each side . Door to be provided with suitable sliding arrangment to withstand the load of door, locking system, 300mm long HPL Handles on inner and outer side. Operation of door should be microprocessor controlled electro mechanical movement mechanism should be allow manual opening in case of power failure. Speed of closing movement to be between 80-120mm /sec and opening speed should be 600 to 800mm / sec (approx) with option of customised opening & closing time,speed of door leaf including half opening option. The door and controls shall comply with IEE regulation. All motors shall be Dc brushless / PMDC motors with essential isolation from mains. Note :(i) The complete door should be CE( Complaince to European standards ) certified or relevant equivalent IS certification if any.Test certificate for hermetic sealing with door frame will be provided by the contractor with pre despatch documents (ii) All required accessories for automation including Suitable size of copper cable is deemed to be included in the item rate.
Hermetically Sealed hinged door : S&F of Hinged door made of HPCL / HPL material (minimum 4mm thick) painted with anti bactrial paint . Thickness of Door to be 50 to 60mm injected with CFC free polyurethane foam Puff insulation having minimum density 40 kg /cum. Colour of door from interior to match the interiors of Room & from outside to match with the outer area.The door should have double glazed vision window size of 300mm x 300mm. The Hermetic sealing should confirm to class 4 ( EN 1.026,EN 12.207).The movement of door to be smooth. Either side of door should be perfectly leveled. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential). Air tightness 99.99% at a pressure of 100KPa. Size of door will be 1500mm x 2100mm (as per AERB Norms) ( size may vary slightly as per site requirement), Complete all as specified and directed. The rates are inclusive of following :- (a) Hard ware / Accessories : Door to be provided with suitable hinges to with stand of the load of door, locking system with keys, heavy duty hydraulic door closer, 300mm long HPL Handles and 250mm long HPL tower bolts on each side and door stopper. Note : The complete door should be CE(Complaine of European standard) certified. Test certificate for hermetic sealing with door frame will be provided by the contractor with pre despatch documents.
Hermetically Sealed hinged door : S&F of Hinged door made of HPCL / HPL material (minimum 4mm thick) painted with anti bactrial paint . Thickness of Door to be 50 to 60mm injected with CFC free polyurethane form Puff insulation having minimum density 40 kg /cum. Colour of door from interior to match the interiors of Room & from outside to match with the outer area.The door should have double glazed vision window size of 300mm x 300mm. The Hermetic sealing should confirm to class 4 ( EN 1.026,EN 12.207).The movement of door to be smooth. Either side of door should be perfectly leveled. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing (to maintain air pressure differential). Air tightness 99.99% at a pressure of 100KPa. Size of door will be 850mm x 2100mm (as per AERB Norms) ( size may vary slightly as per site requirement), Complete all as specified and directed. The rates are inslusive of following :- (a) Hard ware / Accessories : Door to be provided with suitable hinges to with stand of the load of door, locking system with keys, heavy duty hydraulic door closer, 300mm long HPL Handles and 250mm long HPL tower bolts on each side and door stopper. Note : The complete door should be CE(Complaine of European standard) certified. Test certificate for hermetic sealing with door frame will be provided by the contractor with pre despatch documents.
Window with motorized roller Blinds: Supply and fixing factory made UPVC fixed type window made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x58mm). T profile (60mm x 74mm). Glazing bead (35mm x20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mm) to be inserted in required profile including 6mm thick two parallel toughened glass and motorized curtain blinds with FHP motor control and ACB view panel. Blinds should be sandwiched in two parallel glass panes.The window should be fixed in such away that replacement / maintenance of blinds, motors, switches etc should be easily accessible without taking any additional shutdown. Note : All required accessories for automation including Suitable size of copper cable is deemed to be included in the item rate.
S&F in repairs of Compact surgical scrub sink of overall size 2400 mm long x 600 mm wide and 1300mm high with tub depth of minimum 380mm divided into two sink portions, made of 1.50mm thick Stainless Steel sheet of 316 grade with seamless welded construction, polished to stainless finish. Each sink portion to have one sensor based CP brass water sink mixer system for hot and cold water , one sensor based bib tap , one sensor based betadine despenser and one foot operated switch for hand free operation including infra-red sensors with built-in temperature range adjustment and thermostatic mixing valve control located behind the access panel and maintain constant water temperature. The scrub sink to be provided with a front access panel which should be easily removed for access to the water controlled valve, waste connections stoppers and strainers complete in all respect. Note:- Old retrieved items to be deposit in department store.
S&F of Storage unit made with 0.80mm thick stainless steel 304 grade sheet. The storage to be continuously ventilated by positive air in the room through ventilation holes provided at the bottom and top of opposite sides. The storage unit to be divided into 2 or more parts and each part should have individual glass of 10mm thick toughened glass shelf and doors with high quality locking system. The overall size should be 1200mm wide x 2100mm high and 350mm deep . The storage unit should be painted as per specification for wall cladding.
M&L for Granite (colour as approved by GE) 16 to 18mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laidover 15mm thick screed (1:3) including pointing in white cement (1:2) using marble dust with admixer of pigment to match with shade of granite including grinding and polishing complete all as specified and directed by Engr-in-Charg.
Wall cladding: S&F for antimicrobial silver ion Technology PVC wall cladding having minimum 2.50mm thickness or more, smooth finished having approx weight 3.5kg /sqm, able to withstand Temperature upto 60 degree Centigrade. The Colour to be approved by the GE. Method of Fixing : The cladding to be fixed with Aluminium pipe of 25x40 mm with thickness of 1.20 mm on grid framework of 600 mm X 600 mm accuretly aligned with 6mm thick Bison board using raw plugs etc. Joints : PVC cladding to be sealed by hot welding providing a water tight smooth and seamless finish.Internal / External Corners of the PVC cladding should be able to thermoformed on site to provide seamless uniform corner arrangement. Coving between wall and ceiling to be provided with same PVC cladding company. Note : PVC cladding should be VOC ( Volatile Organic Compound) Compliant certificate to be enclosed as per EN 13999:2013 BREEAM and Should have a Fire rating in accordance to EN 13501-1:2007+A1:2009.Contractor must submit the Third party Test Certificate and warrany for 5 years.
S&F 8 mm Square edge perforated painted Calcium silicate False ceiling Tiles painted with Acrylic Emulsion paint of size 595 x 595mm of approved designfixed with powder coated (Powder coating on web bottom only) GI grid consisting of main Tee Section of size (24mm x 32mm x 0.3mm), cross Tee section of size (24mm x 24mm x 0.4mm) suitable for mounting tiles of 595 x 595mm with 4mm dia GI wire suspender,GI adjustable rod of 4mm dia with butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 24mm of all T- section shall be centreblack pre-painted with polyester paint complete all as specified and directed. Note : Manufacturer Test Certificate of the manufracturer will be required on installation.
UPVC Door : Providing and fixing factory made UPVC casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (Onevertical length in between two shutters) (60mm x74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), profile (27mm x 17mm) to be inserted in required T profile, frame will be fixed to the wall wilh 8mm x100mm long fasteners. Hardware: Door to be provided with suitable hinges to with stand of the load of door, locking system with keys, heavy duty hydraulic door closer, suitable Handles and 250mm long Stainless steel tower bolts on each side and door stopper Door transmission gear made of mild sleel with multi point locking system with strikes. (white powder coated) and bottom portion to be fixed with 4mm ACP sheet panel, on top portion and glazing with 8mm thick toughened glass.
UPVC WINDOWS : Supply and and fixing factory made UPVC fixed window made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x20mm) will be mitered cut and fusion welded at allcorners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket.1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners and glazing with 8mm thick toughened glass.
S&F 10 mm thick thoughened glass in square or rectangular shape including necessary fixing hardware complete all as specified.
S&F of Compact surgical scrub sink of overall size 1000 mm long x 600 mm wide and 1300 mm high having wash tub of minimum 380mm made of 1.50mm thick Stainless Steel sheet of 316 grade with seemless welded construction, polished to stainless finish. Sink have one sensor based CP brass water sink mixer system for hot and cold water ,one sensor based bib tap ,one sensor based betadine despenser and one foot operated switch for hand free operation including infra-red sensors with built-in temperature range adjustment and thermostatic mixing valve control located behind the access panel and maintain constant water temperature. The scrub sink to be provided with a front access panel which should be easily removed for access to the water controlled valve, waste connections stoppers and strainers complete in all as specified.
S&F of wood polymer composite (WPC) prelaminated(one side) board of 18 mm thick having minimum density of 32 kg/cum as in cabinet work including necessary hardware / fittings tapping on edges complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 all as specified and directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including taking down cement plaster all as specified and directed.
M&L for preparation of newly palstered surface of walls and applying one coat of alkali resistant primer over a coat of birla white cement putty, sanding the surfaces till smooth finish is obtained and finally applying two coat of oil emelsion distemper etc complete all as directed.
M&L for reinforced cement concrete nominal mix 1:2:4 ( 20mm aggregate ) in Beams, cantilevers, lintels over 1.5m span all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
S&F of 15mm 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc all as specified and directed.
S&F of 20mm 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold watersupply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.
Taking down Chowkhats or frames exc 1.5 Sqm but n exc 4 Sqm each with shutters (without taking off shutters from the frames) including making good the disturbed surfaces and finishing the same complete.
Taking down Chowkhats or frames not exc 1.5 Sqm each with shutters (without taking off shutters from the frames) including making good the disturbed surfaces and finishing the same complete.
Dismantling Floor hearth or wall tiling including cement mortar bedding (But not backing), or insulation boards/slabs/blankets, andy thickness, including cover fillets all as specified and directred.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified and directed. Note for item No 1.00 to 1.28:- Work in OT/ICU shall be executed by a specialist firm to be approved by CWE before execution, having experience of minimum 03 years of executing such works in Govt hospitals/reputed Pvt Hospital minimum 100 Beds.
Internal Electrification
Taking down carefully old and unserviceable aluminium point wiring for light/fan/socket or power point complete including fittings such as switches, ceiling rose, pendents, regulators, sockets, bell, distribution boards and MCB's etc and making good disturbed surface of walls. floors etc to match with the existing surface complete all as specified and directed.
One light point controlled by modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and directed.
One ceiling Fan/Exhaust Fan point controlled by modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and directed.
One 6 Amp socket outlet point on independent board controlled by modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and directed.
One 6 Amp socket outlet point on same board controlled by modular switch 6 Amp, single pole, one way, one module, 240V, complete all as specified and directed.
One light point controlled by modular switch 6 Amp, single pole, two way, two module, 240V, complete all as specified and directed.
All as per item No. 2 here in before but for One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 Sqmm size all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 2 here-in-before but with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and sheathed cable for one multipurpose switch socket outlet 6 pin 6/16 Amps on independent board including 2.5 Sqmm single core solid copper conductor 1100 volts grade PVC insulated and sheathed cable as earth continuity conductor to common earth and connecting to earth dolly.
S & F Modular switch 1 way 6 A, 1 module, one way all as specified and directed by Engineer - in – Charge.
S & F Modular switch 1 way 16 A, 1 module, one way all as specified and directed by Engineer - in – Charge.
S & F Modular Bell push 6 A, 1 module, single pole one way, all as specified and directed by Engineer - in – Charge .
S & F switch modular two way 6 A, 1 module all as specified and directed by Engineer - in – Charge.
S&F electric call bell/ buzzer, AC, 230 volts, single pole, complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket, 6A - 2/3 pin combined 2 module all as specified and directed by Engineer-in –Charge.
S&F modular socket 6A/16A - 2/3 pin combined 2 module all as specified and directed by Engineer-in –Charge.
S&F modular fan step type regulator, 120W - 2 module all as specified and directed by Engineer-in –Charge.
M & L ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge .
S & F PVC blanking plate for filling empty space in terminal boxes/ DBs complete all as specified and as directed by Engineer-in-Charge.
S&F modular White cover plate with frame, 3 module all as specified and directed by Engineer-in –Charge.
S&F modular White cover plate with frame, 4 module all as specified and directed by Engineer-in –Charge.
S&F modular White cover plate with frame, 6 module all as specified and directed by Engineer-in –Charge.
S&F modular White cover plate with frame, 8 module all as specified and directed by Engineer-in –Charge.
S&F modular Metal flush box 3 module all as specified and directed by Engineer-in –Charge.
S&F modular Metal flush box 4 module all as specified and directed by Engineer-in –Charge.
S&F modular Metal flush box 6 module all as specified and directed by Engineer-in –Charge.
S&F modular Metal flush box 8 module all as specified and directed by Engineer-in –Charge.
Supply & fixing Housing & Finish shall CRCA powder coated white after phosphochromate treatment. Electronic driver shall Powered by an independent Isolated, SELV Output electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection. Dimension of light is 2 x 2 ft, 48 Watt.
S&F in replacement of LED tube light fittings 1 x 10 W robust and high performance batten comprises extruded channel in thermally conductive material. High translucent serrated milky white diffuseris used to get glare free and smooth light distribution. Efficiency 100 lm/W.
S & F 1 X 20 Watt LED tube lght fittings with High -quality and design , extruded aluminium housing enhances safety. High quality PC diffuser, Reliable and robust housing structure, maximize the endurance over the life time slime integrated design, easy to install efficiency 125 lm/Watt.
Peripheral Light for OT. S & F of Peripheral lighting LED type and clean room luminaires with illuminance of minimum 500 Lux. Peripheral light fittings shall be minimum of size 2 feet x 2 feet. These shall be minimum 8 in numbers for each OT with optical antiglare system. Luminaries cover shall be made of highly resistant, disinfectant proof laminated safety glass/acrylic with stylish fine-grained surface. The body of light should be made of highly specularanodized aluminium with powder coated. The fittings shall be uniformly and aesthetically distributed on ceiling to provide uniform illumination in the OTs. Light shall not be interfered when green mode endoscopy is performed. Light shall be protected with IP 65 . Electronic driver shall Powered by an independent Isolated, SELV Output electronic LED dimmable driver (SMPS based constant current supply) with Output Short-circuit protection. Note. Lux level to be maintained in all OTs shall not be less than 500 lux. Number of lights, wattage of fittings shall be designed accordingly. Same shall be approved by GE before procurement.
Double Dome Ceiling Mounted OT Light with HD Camera on Centre of Main Dome, separate arm for HD Screen and Audio-Video Cabling to outside the Operating Theatre. Supply, fixing, commissioning & testing of Surgical light double dome LED ceiling mounted OT LED Light.The control equipment placed inside the operating room. The life of LEDs must be at least 50000 hrs. Each dome should have a multi-lens atrix for shadow free, homogeneous, pure white, natural light field. It should be flat scaled light body designed for Laminar Air Flow Ceilings. It should have a IIR free Illumination. Colour Rendering Index (CRI) not less than 95, Gamut Area Index (GAI) not less than 80, Light field diameter (at 1 mtr distance, without change in intensity) : 20 cm to 28 cm (±10% ). The illumination intensity should be at least 1,60,000 Lux at 1 meter distance for each dome. Colour Temperature : Minimum range 3800°K-5000°K (±10%) variable. It should have adjustable focus system. It should have light dimming range 5% to 100% (Minimum). Working range minimum 750 mm to 1100 mm (±10%). It should be with dual controls for all controllable parameters. One at dome assembly and down and another, wired/wireless remote on the wall. It should be possible to adjust the dome at any position, have easy maneuverable, free up and down and swing movements and free rotatable at any angle. It should be supplied with 9 numbers of additional sterile handles. Every light petal must have a provision to be individually replaceable services onsite. It should be with CE marks or US FDA approved. Note : OT lights should be connected with existing UPS system for backup, cost for which is deemed to included in overall cost quoted by the contractor.
Specification of HD Camera . The HD Camera system should have minimum capacity of 1080p/i. It should be integrated in light camera system at the centre of one principal dome of this light system/third arm in order to capture images and video sequences of the open cases. Signal to noise ratio (S/N Ratio) should be more than 50 dB. CCDD/CMOS : 1/3" or 1/1.2". Optical Zoom minimum 10X, Digital Zoom minimum 12-15X Video output : HD, DVI, S-Video and composite video. White balance and gain :Automatic/Manual. OT lihgt and integrated Camera shall have a control through touch type digital panel of the control equipment placed inside the operating room. Note: All items which are mounted on ceiling like pendants, Double Dome OT LED light with HD Camera, Peripheral lights and cleanroom luminaries should be compatible to each other.
Recording System and PACS (Picture Archiving & Communication System) Monitor. Recording system shall be capacity of minimum one TB storage space. Data cable for communication from both pendants and monitors shall be laid down upto outside of OT in a patch port for future expansion for all OTs where is no integration. Patch Panel for power and signal shall be laid down for minimum 40" LED Monitor at wall of OTs. Record shall be capable of recording video from others sources like microscopes, endoscopes etc. suitable provision for the same shall be made. Monitor shall be medical grade and integrated with hospital PACS. The contractor shall do the necessary coordination with hospital authorities for connecting the PACS monitor to the hospital PACS. If hospital/institute PACS is not available, contractor shall terminate all PACS monitor connection to switch loacated in OT Corridoor & Waiting area for further connection by the hospital. Monitor shall be flush mounted with suitable frame in OT wall. Frame shall be openable/serviceable for service.
HD LED Flat Panel Monitor. HD minimum 40" LED flat Panel Monitor shall be medical grade high-definition progressive scan flat-panel monitors with ceiling mounted spring arm suspension to support high definition/HDTV progressive scan images and shall be able to support and display DVI/HDTV, RGBHV, S-Video, Composite video signals. Aspect ratio 16:9/16:10. Resolution : 1920 x1080 or better. It shall be met IP 54 regulations. The flat panel suspension shall be ready with the cables for integration of high-definition digital (DVI/HDTV), RGBHV (High Resolution), SVHS (S-video), composite video signals to travel from the various sources of video like endoscopic camera, room camera, in-light camera, high definition flat panel monitors, while assuring apivore solution/signal. Monitor shall be capable of displaying from other sources like endoscope, microcope etc. Note: Rate quoted shall deemed to be included from Ser Item No 2.32 to 2.35 and nothing is extra to be payable on this account.
S & F MCB distribution board of sheet metal single pole and neutral (SPN) 12 way, double door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
S & F MCB distribution board of sheet metal single pole and neutral (SPN) 8 way, double door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
S & F MCB distribution board of sheet metal single pole and neutral (SPN) 4 way, single door, with bus bar 240 volt all as specified and directed by Engineer-in- Charge.
S & F sheet metal enclosure distribution board triple pole and neutral (TPN) 4 way, double door, 415 volt all as specified and directed by Engineer-in- Charge.
S & F sheet metal enclosure distribution board triple pole and neutral (TPN) 8 way, double door, 415 volt all as specified and directed by Engineer-in- Charge.
S & F sheet metal enclosure distribution board triple pole and neutral (TPN) 12 way, double door, 415 volt all as specified and directed by Engineer-in- Charge.
VTPN DB 12 way with MCCB as incomer ,metal door, ready to use DBs provided with Neutral Bar, Mechanical Impact Strenth IK 08 , Insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for 3 pole and 4 pole MCCB's upto 125 Amp as Incommer and MCBs (TP/SP) as outgoing, IP 43 protection, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including complete all as specified and directed.
VTPN DB 8 way with MCCB as incomer ,metal door, ready to use DBs provided with Neutral Bar, Mechanical Impact Strenth IK 08 , Insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for 3 pole and 4 pole MCCB's upto 125 Amp as Incommer and MCBs (TP/SP) as outgoing, IP 43 protection, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including complete all as specified and directed.
Supply and fix MCCB 100 Amp, 415 Volt, 4 Pole, Ics=100% of Icu with spreader & rom,16 KA complete all as specified and directed.
Supply and fix MCCB 125 Amp, 415 Volt, 4 Pole, Ics=100% of Icu with spreader & rom,16 KA complete all as specified and directed.
S & F MCB Three Pole and Neutral (TPN) 40-100 Amps, 415 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
S & F MCB Single Pole and Neutral (SPN) 40-63 Amps, 240 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
S & F MCB Single Pole (SP) 06-32 Amps, 240 Volt 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
Supply and fixing single pole and neutral enclosures with two pin and earth plug and socket complete with double pole MCB 20 Amps, 240 V all as specified and directed by Engineer - in - Charge.
Supply and fixing Triple pole and earth enclosure with three pin and earth plug with socket complete with one triple pole MCB 415 Volt 32 Amps all as specified and directed by Engineer - in - Charge.
Supply and fixing Triple pole and earth enclosure with with three pin and earth plug with socket complete with one triple pole MCB 415 Volt 63 Amps all as specified and directed by Engineer - in - Charge.
Dismantling and taking down ceiling fans of any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testing all as specified and directed.
Dismantling and taking down exhaust fans of any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re-fixing the same in position, connecting and testing all as specified and as directed.
Dismantling of existing Geyser 25-50 Ltr and Split/Window/Tower AC of 1.0/1.5/2.0/5.0 TR capacity for servicing by water cleaning dust, filling cavities with filler complete and re fixing the same position after completion of civil work, connecting and testing complete carefully, all as speciied and directed.
S & F in repairs submain wiring with four single core cables PVC FRLS insulated unsheathed 16.0 Sqmm stranded copper conductor drawn in PVC conduit or Corrugated flexible Hose pipe (As per site requirement) and its accessories with and including PVC FRLS insulated one run single core cables 16.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. NOTE:- (i) Four runs of 16.0 sq.mm copper conductor, one runs of 16.0 sq.mm copper earth continuity conductor shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) PVC conduit or Corrugated flexible Hose pipe shall be measured and paid separately.
Sub main wiring complete with 4 runs of 10.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn in PVC conduit or Corrugated flexible Hose pipe (As per site requirement) and its accessories and connecting terminal ends to DB's including providing one run of 10.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, fixed in repairs, complete all as specified and directed. NOTE:- (i) Four runs of 10.0 sq.mm copper conductor, one runs of 10.0 sq.mm copper earth continuity conductor shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) PVC conduit or Corrugated flexible Hose pipe shall be measured and paid separately.
Sub main wiring complete with 4 runs of 6.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn in PVC conduit or Corrugated flexible Hose pipe (As per site requirement) and its accessories and connecting terminal ends to DB's including providing one runs of 6.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, fixed in repairs, complete all as specified and directed. NOTE:- (i) Four runs of 6.0 sq.mm copper conductor, one runs of 6.0 sq.mm copper earth continuity conductor shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) PVC conduit or Corrugated flexible Hose pipe shall be measured and paid separately.
Submain wiring with 2 runs of single core 4.0 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLS copper conductor drawn in PVC conduit or Corrugated flexible Hose pipe (As per site requirement) and its accessories in concealed system including one run of single core 4.0 sqmm dia FRLS PVC insulated unsheated multistaranded 1100 volts grade copper conductor cable as earth continuty conductor along with the wiring and connected from Submain DB/main board to Metal clad socket complete all as specified and directed. NOTE:- (i) Two runs of 4.0 sq.mm copper conductor, one runs of 4.0 sq.mm copper earth continuity conductor shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) PVC conduit or Corrugated flexible Hose pipe shall be measured and paid separately.
Submain wiring with 2 runs of single core 6.0 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLS copper conductor drawn in PVC conduit or Corrugated flexible Hose pipe (As per site requirement) and its accessories in concealed system including one run of single core 6.0 sqmm dia FRLS PVC insulated unsheated multistaranded 1100 volts grade copper conductor cable as earth continuty conductor along with the wiring and connected from Submain DB/main board to Metal clad socket complete all as specified and directed. NOTE:- (i) Two runs of 6.0 sq.mm copper conductor, one runs of 6.0 sq.mm copper earth continuity conductor shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) PVC conduit or Corrugated flexible Hose pipe shall be measured and paid separately.
Submain wiring with 2 runs of single core 10.0 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLS copper conductor drawn in PVC conduit or Corrugated flexible Hose pipe (As per site requirement) and its accessories in concealed system including one run of single core 10.0 sqmm dia FRLS PVC insulated unsheated multistaranded 1100 volts grade copper conductor cable as earth continuty conductor along with the wiring and connected from Submain DB/main board to Metal clad socket complete all as specified and directed. NOTE:- (i) Two runs of 10.0 sq.mm copper conductor, one runs of 10.0 sq.mm copper earth continuity conductor shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) PVC conduit or Corrugated flexible Hose pipe shall be measured and paid separately.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 25 mm x 4 mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Rate quoted shall deemed to include GI earth strip and GI protection pipe light grade. (c) Rate quoted shall deemed to include taking down old items. (d) Minimum 100 Kg salt and 100 Kg charcoal granual type to be used for each earth pit. The bed to be done in 3 x 15 cm depth of salt and 3 x 15 cm depth of charcoal in aternate layer. (e) PVC type DC insulators with screws, nuts, bolts etc to be used in suface/wall/floor for mounting of strip and distance between two insulator shall not be less than 1.0 mtr.
M & L for copper strip of size 20 x 3 mm for copper Earthing continuity conductor or main earthing lead fixed to wall or batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to or any other indicated situation etc complete all as specified and as directed. Note 1.: PVC type DC insulators with screws, nuts, bolts etc to be used in suface/wall/floor for mounting of strip and distance between two insulator shall not be less than 1.0 mtr. Rate quoted shall deemed to be included the PVC DC insulators. Note 2: The strip will be measured and paid separately beyond 7.5 mtr for each earthing.
M & L for in replacement of galvanised iron strip 25 x 4 mm buried in ground with saddles and fixing screwes etc for roof conductors and down conductors including removing and replacement of deterioted SS bolts, nuts and washers as required at site etc in the existing GI strip of any size from the starting point to upto the end connected points all as specified and directed by Engr-in-Charge. Note 1. PVC type DC insulators with screws, nuts, bolts etc to be used in suface/wall/floor for mounting of strip and distance between two insulator shall not be less than 1.0 mtr. Rate quoted shall deemed to be included the PVC DC insulators. Note 2. The strip will be measured and paid separately beyond 7.5 mtr for each earthing.
Nurse Calling System. S & F Central display unit and control unit (20+8) modules with data process and control unit upto 4 digit numeric display for a bed/ toilet complete all as specified and directed.
S & F bed side calling unit (Wired) with attached patient hand set with LED indication complete all as specified and directed .
S & F Toilet emergency calling unit with attached pull cord (Wired) complete all as specified and directed.
M & L in replacement of Cat 6 cable for connection from central display unit to bed side calling point complete all as specified and direccted .
M & L of 20 mm dia, rigid non metallic PVC conduit (Medium grade), 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified.
M & L of 20 mm dia, Corrugated flexible Hose pipe, 'ISI marked', inclusive of all fittings and fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified.
M & L of 25 mm dia, rigid non metallic PVC conduit (Medium grade), 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified.
M & L of 25 mm dia, Corrugated flexible Hose pipe, 'ISI marked', inclusive of all fittings and fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified.
M & L of 32 mm dia, rigid non metallic PVC conduit (Medium grade), 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified.
M & L of 32 mm dia, Corrugated flexible Hose pipe, 'ISI marked', inclusive of all fittings and fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified.
M & L of 40 mm dia, rigid non metallic PVC conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified.
M & L of 40 mm dia, Corrugated flexible Hose pipe, 'ISI marked', inclusive of all fittings and fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified.
Fire Alarm & Smoke Detector System
M & L for single loop Analogue Addressable Fire Alarm Control Panel expandable via plug-in loop driver boards, loop current minimum 500mA per loop, dual flash based microprocessor, supports to connect 126 detector and devices (protocol dependent) in any combination in each loop, equipped with a white backlit display ( 840 Character/240x64 pixel resolution/10" Touchscreen) graphical LCD Display with atleast 6 lines of information, 200 zones (soft zones) per panel and 2000 zones on network, fully programmable via alphanumeric keypad or configuration software without using any kind of DONGLE/LICENCE OR SPECIAL CABLE, dediacted USB and RS-232 serial port for direct or PC connection. Should support 5000 historic events and 500 fire alarm events. Panel shall be equipped with in-built multi-meter for live monitoring of loop current, earth voltage, loop voltage etc.Panel should support peer to peer networking between panels capable of networking 32 nodes on standard networking and 200 nodes on secured network.Panel housing shall meets min IP30 ingress protection classification finished in RAL 7035. The panel shall have optional redundancy facility. The panel shall be capable of providing output for BMS/ SCADA software through optional Modbus/ Bacnet module (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Independently certified as complying with requirements of BS EN 54 Part 2, 4 and 13. Manufacturer's Authorisation letter is mandatory.
M & L for UL,VDS & FM approved High Definition LED based Aspirating Smoke and heat Detector with single Pipe Inlet Single Sensor on board Programmer suitable for 120 mtr pipe. Length with area coverage of minimum 1220 square meter. ASD 532 or equivalent with suitable accesories and licences. The Unit should have external filter box. The detector shall have IP 54 protection catagory. The sensitivity range should be 0.002%-10% obsc /meter. The Unit should have 2 in-built relay and provision of installing additional relay cards. Manufacturer's authorisation letter is mandatory.
M & L for UL listed Capillary Sampling Point As per design (Union and adaptor, 1.5m Capillary Tube (Nominal Dia: 3/8” x 1/4" ) & Sampling Point). Manufacturer's authorisation letter is mandatory.
M & L for the ABS/ CPVC Pipe 25 mm Dia & Accessories as per design & area.
M & L for Power Supply shall be supplied with all necessary enclosures and shall be Monitored by the Fire Alarm Control Panel. Complete with 240 volts AC PSU, automatic battery charger, 24 volts SMF batteries sufficient for 24 hours normal working and for 30 minutes on full alarm conditions.
M & L for Intelligent Analogue Single Input/ Monitor Module, for Flow switch monitoring and other input purposes , with in-built short circuit isolator, Bi-colour LED's for local indication of device status, auto/ electronically or hard addressed, with IP52 enclosure.Independently certified as complying with requirements of BS EN 54 Part 18 and 17.
M & L for Analogue Addressable Multisensor (combination of smoke and heat including both ROR & fixed) Detector with enhanced optical sensing with cone technology to provide immunity to false alarms, Serpentine pathway designed to provide a barrier against dust and insect ingress, two heat sensors (thermistors), programmable 5 senstivity modes with one smoke only, one heat only and three multi modes of operation. In-built integrated short circuit isolator to protect against cable faults, tri-colour LED's with 360 degree view of status, auto/ electronically or hard addressed, utilises dynamic algorithms providing transient rejection and drift compensation with IP 44 rating. Independently certified as complying with requirements of BS EN 54 Part 5, 7 and 17. Manufacturer's authorisation letter is mandatory.
M & L for Standard detector base for mounting the compatible addressable detectors.
M & L for Analogue addressable resettable Manual Call Point , with in-built integrated short circuit isolator. Bi-Colour LED for local indication of device status with 170 degree view, single action operation, reset to normal condition using special reset key, clearly visible alarm flag in the activated state, IP44 rating. Independently certified as complying with requirements of BS EN 54 Part 11 and 17.
M & L for 2 Core 1.5 Sq mm PVC insulated copper conductor armoured cable.
M & L for Mounting Accessories like back box for detectors, devices & Cable glands, etc
Commissioning, installation and Testing of entire fire alarm and smoke & heat detector system as specified in Ser Item No 3.01 to 3.12 all as specified and directed by Engineer-in-Charge. (Individual items shall be measured and paid under respective items of the schedule. Note 1. Complete system of Fire Alarm & Smoke and heat detectors shall be executed by a firm which has minimum 3 years experience in executing similar jobs. Credential of firm shall be approved by CWE before undertaking subject work. Note 2. Complete system shall be tested in presence of User rep, rep of CWE and Engineer-in-Charge. Only on successful testing of system, work against the schedule shall be deemed to be completed. Note 3. Bidder shall visit site before quoting. Any item left out for successful completion of job is deemed to be included in overall rates quoted. Note 4. Complete layout of system shall be got approved from GE before execution.
Medical Equipment & MGPS
(a) Surgeon's Pendant Double Arms. S & F heavy duty ceiling mounted, aluminium powder coated body, adjustable shelf with two rails one on each side : 3 number, 6 trays and one drawer double moveable arm (any combination), with total coverage of minimum 1800 mm. Surgeon Pendant system should have the facility to provide convinient positioning of medical equipment, medical gas terminal units, electrical and specially service in OT. Pendant should be facilitated with load carrying capacity of minimum 180 Kg. The arm should rotate up to 330° and ability of horizontal and vertical movement with electromagnetic brakes .Vertical movement shall be motorised. Pendant shall be provided with 10 Nos of electrical 6/16 Amp Power Socket having independent switch. Pendant shall be supplied with outlets and probes as Oxygen (Oշ) and MA4 : one each, Vaccum outlets : 2 number Air (7 Bar) outlet: one number and COշ outlet: one number, adjustable shelf with two rails one number each side 3 numbers , Data socket RJ-45: 2 number, IV fluid pole with 2 hooks : 1 number (Pole shall be capable of stacking 4 syringe pumps) as approved by the GE. (b) Standard & Classification. The pendant shall be European CE cetified with 4 digit notified body number/USFDA/ETL/UL/BIS certified/listed under medical devices directive with complied to ISO-9001,CE,14001,13485,WHO & 45001.
(a) Surgeon's Pendant Single Arms. S & F heavy duty ceiling mounted, aluminium powder coated body, adjustable shelf with two rails one on each side : 3 number, 6 trays and one drawer single moveable arm (any combination), with total coverage of minimum 900 mm. Surgeon Pendant system should have the facility to provide convinient positioning of medical equipment, medical gas terminal units, electrical and specially service in OT. Pendant should be facilitated with load carrying capacity of minimum 180 Kg. The arm should be rotated up to 330° and ability of horizontal and vertical movement with electromagnetic brakes .Vertical movement shall be motorised. Pendant shall be provided with 10 Nos of electrical 6/16 Amp Power Socket having independent switch. Pendant shall be supplied with outlets and probes as Oxygen (Oշ) and MA4 : one each, Vaccum outlets : 2 number Air (7 Bar) outlet: one number and COշ outlet: one number, adjustable shelf with two rails one number each side 3 numbers , Data socket RJ-45: 2 number, IV fluid pole with 2 hooks : 1 number (Pole shall be capable of stacking 4 syringe pumps) as approved by the GE. (b) Standard & Classification. The pendant shall be European CE cetified with 4 digit notified body number/USFDA/ETL/UL/BIS certified/listed under medical devices directive with complied to ISO-9001,CE,14001,13485,WHO & 45001.
(a) IP Based two way Audio-Video Communication System. S & F IP Based two way Audio-Video Communication System consist of one loudspeaker, one hand mic and one wireless collar microphone with echo cancellation shall be installed within the operating room, suitable cable material and a patch panel should be offered as per the position of the loudspeaker. (b) Design Parameter. The system should have in built IP based Uncast Video Streaming facility with zero latency in order to transmit live surgery on Hospital network/Seminar/Conference/lecture theatre/Auditorium. It should be consist of two microphone input. It should have auxiliary input for connecting external audio/video devices like HD TV for presentation. The system should be intigrated with operation theatre control panel.
(a) Horizontal Bed Head Panel. S & F of Horizontal Bed Head panel having minimum length 1.2 meter, maximum length 1.8 meter efficient, safe & Robust design in extruded aluminium section smooth curved surfaces and choice of base colour and fascia plates. It should have integrated rail system to mount accessories. The handwall system should be constructed of aluminium extrusions joined together to form a carcass to suit the particular application. Unit should be factory made and assembled for electrical and mechanical components. (b) Design Parameter. The panel should be designed to accommodate the Gas outlets for Oxygen-02 Nos, Medical Air 4 Bar-02 Nos & Vacuum-02 Nos. It shall be consist of minimum 16 Nos Power Sockets with independent switches 6/16 Amps. It should be supplied with integrated rail for mounting accessories. Each Bed Head Panel should be supplied with medical and electrical outlets pre-fitted and internally wired. (c) Standard & Classification. ISO-9001,CE,14001,13485,WHO & 45001
(a) Touch type OT Control Panel. Supply, fixing, commissioning and testing of Digital display panel consist of minimum of 30" flat Monitor with computer to be fixed flush with the OT wall for PACS viewing. Touch Screen Control Panel must be able to show temperature, humidity in the operating theatre and must be able to be set on required temperature of air as well as light intensity. (b) Design Parameter. It should be shown the function of clock and stopwatch. It consist of Digital clock:(hh:mm:ss), Elapsed Clock: (hh:mm:ss) Start-stop-reset; Anesthesia Clock: (hh:mm:ss) & Start-stop-reset. This should be a single panel or uniformly combined individual panels to suit the ambience.The panel should be accommodated all necessary controls for the correct. The Digital clock and the elapsed time indicator: Both should have large LCD display for easy visibility from a distance. The digit height approximately: 60mm. The Medical gas alarm should indicate high and low gas pressures for each gas service. Present in the OR including vacuum. This should be supported by audible alarm also. The panel should have an alarm mute (fault annunciation) facility. The sensors (pressure switches) should be at the nearest isolation valve. Control for general lighting: ON/OFF and dimming controls organized in groups to provide uniform illumination. Control of the operating light major and satellite and camera control (ON/OFF and intensity control) should be provided. Hand free telephone set with memory should be located at one side. Temperature and humidity control for the room connected to the AHU. (Adjustable from the panel). There shall be a provision of temperature adjustment from the controller (temp adjustment of ±5°C to be achieved within 5 minutes). Digital room pressure indicator in cm of HշO or equivalent (signal from pressure sensor). HEPA filter bank differential pressure indicator desirable. Provision for inbuilt recording of OT camera. The control panel shall be able to integrated with HIS (Hospital Information System)/BMS. Should have provision for data processing. Should interface with Isolated power supply systems to get the alarms/alerts. The control panel shall be able to display the isolation panel alarm conditions alongwith MGPS Alarms. IP Based two way Audio-Video Communication System to be integrated with the control panel. Note: Cost of integration between touch type digital control panel with IP based two way Audio-Video communication system shall deemed to be included in overall cost quoted. No extra amount shall payable on this account.
Operating List Board. S & F operating list board should be provided in each operating theatre made of ceramic having magnetic properties and should be flushed mounted to the wall of the operating room. The laminated board should be bonded to 40 mm high density fire board sheet for additional rigidity. The board have minimum size 1000 mm x 700 mm x 60 mm.
SURGICAL AIR SYSTEM INSIDE THE OT. One additional single Medical Gas Pipeline (One gas pipeline for Surgical Air) inside the OT shall be provided with matching exisitng Medical Gas Pipeline system service Valve box without disturbing the exisitng service . Shall bring the Medical Gas Pipeline inside the OTs till ceiling pendants and provide NIST connections for each gas pipeline. Medical Gas Piping by means of National Institute of Standards and Technology (NIST) connections. The Surgical Air System should have consist of followings:- Specification. As Per EN 737 & HTM Standards. The Gas piping used for transportation should be as EN 13348 / EN 1057 standards with copper fittings as per EN 1254 standards. Entire Installation should be done under direct supervision of the qualified & trained engineer who is certified as authorized person of Health Technical Memorandum-02 (HTM02) & should be awarded as level 4 professional award. Valid authorization & certificate should be submitted along with the bid. Handover certificate should also be signed by him with registration number. Need a report against handover of satisfactory installation as per guidelines of HTM02.
Supply and fix of outlet Points for Compressed Air 7 Bar front loaded.
Supply and fix of Valve Box 1 Gas.
Supply and fix of Alarm 1 Gas Digital.
Supply and fix of Copper piping Medical Grade as per BS 133448/1057 Lolyd Certified std complete with fitting,brazing painting of following size :-
(a) 15 mm dia of medical grade copper pipe.
(b) 22 mm dia of Medical grade copper pipe.
(c) 28mm dia of Medical grade copper pipe.
Supply, installation, commissioning and testing of Compressed Air System consisting of two nos of Oil free reciprocating Air Compressors of 30 cfm capacity with 10 HP motor base plate mounted with one 1500 ltr receiver tank and interconnecting piping and electrical starter and pressure switch all as specified and directed by Engineer-in-Charge. The compressed Air compressor to be provided 02 Nos (One working and one will be as standby). Note:- Foundation design shall be as per OEM specification and included in overall cost quoted.
Supply & Fix of Air Drier Dry spell type of 50 CFM capacity with inlet and outlet filters.
Supply & Fix of Pressure reducing regulator system having two regulators and 4 No isolation valves of 28 mm size
M & L for fabrication of shed for compressors size 3.0 mtr x 4.5 mtr and minimum height of 2.4 mtr on back side and 3.7 mtr at front side using MS angle frame of 75 mm x 75mm x 6 mm in vertical post embeded in post pole with PCC 1:2:4 with purlin and rafter of 50 mm x 50 mm x 6 mm for roof. The cladding and railing of shed to be provided with 0.55 mm thick galvaniised sheet wiith 100 mm thick PCC 1:2:4 flooring level over 150 mm (PCC 1:4:8) sub base over rammed earth complete in all respect and as directed by Engr-in-Charge. Note for Ser Item No 4.00 to 5.11 Note 1. Complete system shall be installed by a specialist firm to be approved by CWE before execution, having experience of minimum 03 years of executing such works in Govt hospitals/reputed Pvt Hospital minimum 100 Beds. Note 2. Contractor shall visit site before bidding. Any item left out for successful completion of work is deemed to be included in overall cost quoted. Note 3. SURGICAL AIR SYSTEM is to be provided for existing 10 Nos of OTs. Contractor shall bid accordingly. Note 4. Copper cable of suitable size for connecting up Medical Equipment shall be provided by Contractor within overall cost quoted. Note 5. Surgical Air Pipeline is being provided shall be connected with existing system within overall cost quoted.
Air Conditioning
Design,Supply, Installation, Commissioning and Testing of VRF type AC Plant with Outdoor type VRF Units air cooled, 100% inverter compressor based VRF system using R-410a refrigerant Gas, including first fill of refrigerant to meet desired conditions as below. The bidder shall submit complete design of Air Conditioning plant alongwith heat load calculation, size of pipe, size of AC duct, AHU, LT panel, Control cable, LT switchgear. Nearest LT take over point is available around 300-350 mtr away from the site. LT Cable and LT Panel is deemed to be included in the scope of work. Design Parameter. (a) Temperature - 21°C ± 3°C (b) Relative Humidity - 55% (±5%) (c) Air Filtration Unit (99% down to 0.3 micron) (d) 100% Fresh Air. (e) Laminar Air Flow PLENUM with HEPA filter-01 for each OT. (f) Fire Damper-01 for each OT. (g) Return Air Riser -04 Nos for each OT. (h) Minimum positive pressure to be maintained 2.5 Pascal. (j) Time required to achieve design condition after switching on plant shall not exceed 30 minutes. (k) The said design Parameter are applicable for Ser No 6:02 to 6:04. Air conditionind plants shall consist of followings :-
For OT Nos 01 & 07 minimum Capacity of VRF Unit 28 HP-02 Nos for each OT (01 x working + 01 x standby).
For OT Nos 03, 06 & 10 minimum Capacity of VRF Unit 24 HP-02 Nos for each OT (01 x working + 01 x standby).
For OT No 08 minimum Capacity of VRF Unit 18 HP-02 Nos (01 x working + 01 x standby).
Supply, Installation, Commissioning and Testing of VRF type AC Plant with Outdoor type VRF Units of above mentioned Capacity to meet 100% load, ( 01 No. Working + 01 No. Standby ) air cooled, 100% inverter compressor based VRF system using R-410a refrigerant Gas, including first fill of refrigerant. The system shall be suitable for both cooling and heating purposes and shall work on 3-phase, 415V, 50Hz AC power supply. Twin scroll compressors with accumulator, air cooled condensers made with corrosion proof blue fins and its fan with motors, microprocessor controls, control panel along with internal control and power wiring, internal interconnected refrigerant pipes, charging ports with pre-charged non CFC gas of R-410a as per OEM recommendations. Unit shall be designed for continous run upto an outside temp of 56°C. There shall be no "DERATING" of unit upto outside temp of 43°C.
Supply, installation, Commissioning & Testing of AHU Expansion Kit to Integrate the AHU system with VRF ODU
S & F Wired Remote control for VRF type AC unit complete all as specified and directed.
S & F refrigerant Y-Joints for Combining Outdoor Units required for distribution of refrigerant in copper piping as per recommended by OEM.
Supply, installation, Commissioning and Testing high pressure interconnecting refrigerant pipe of suitable sizes including civil work like wall opening for copper and drain pipe for VRF system with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications. All Piping should be layed on cable trays with cover for outdoor locations as per OEM recommendations and PVC sleeves shall be provided wherever pipe is crossing the wall. Food grade nitrogen shall be used while making brazing joints complete all as specified and directed.
Supply and charging refrigerant gas of R-410a complete all as specified and directed.
Supply, assembly and erection of 22 Gauge Aluminium Ducting with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete including necessary MS Channels, gurder supports as approved by Engg -in-Charge including making of hole in any type of wall and making good with plastering work, mesonary work and necessary MS channel supports complete all as specified and directed.
Supply and fixing of fire proof double layered canvas cloth connection for AHU outlet including inspection opening complete with flanges made out of 22 Gauge SS Sheet on both side for connection to AHU and duct with nuts , bolts complete all as specified and directed.
Supply, installation, Commissioning & Testing of UL-555 motorised fire dampers complete with smoke detector/ thermister linkage etc in AHU Room Supply Air Ducts as required for operation complete all as specified and directed.
Supply, installation, Commissioning & Testing of Actuator with control panel in AHU Room Supply Air Ducts as required for operation complete all as specified and directed.
Supply, installaton, Testing and Balancing of Supply/Exhaust Air Grill with control dampers with powder coated extruded aluminium construction complete all as specified and directed
Supply & Erection of 25 mm thick nitrile duct insulation with Aluminium foil. The thermal insulation shall be 25 mm thick non-fibrous, fire retardant, closed cell, tri- dimensional chemically crosslinked polythylene foam, confirming to class O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminum foil complete all as specified and directed.
Supply and fixing insulation acoustic lining of supply air ducting complete with GI frame, tissue paper, 26 Gauge perforated AL Sheet 25mm thick of density 32 Kg/Cum fiber glass insulation complete all as specified and directed.
M&L for Wiring of AHU with 4 core X 10.0 Sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 40mm dia as per IS 694 or on and including cable tray complete all as specified and directed. (Note : Four core of wire with heavy duty ISI Marked PVC conduit will be considered as one Length.)
M&L for Wiring of VRF Units with 4 core X 16.0 Sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 or on and including cable tray complete all as specified and directed. (Note : Four core wire with heavy duty ISI Marked PVC conduit will be considered as one Length.) Note:- Ser item No 6.19 & 6.20 where ever concealed conduit cannot be provided, wiring shall be laid on cable tray. Cost of which is included in overall cost quoted by contractor. Nothing extra shall be payable.
M&L for control wiring with 2 core X 1.5 Sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed. (Note : Two core of wire with heavy duty ISI Marked PVC conduit will be considered as one Length.)
M&L for control wiring with 2 core X 0.75 Sqmm Sheilded wire, twisted pair & Sheilded 2 Core Sheathed Wire, Sheilding use for Earthing Connection, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed.(Note : Two core of wire with heavy duty ISI Marked PVC conduit will be considered as one Length.)
Air Handling Units DX Type for OTs Area. Supply, Installation, Commissioning and Testing of Smart AHU(Air Handling Unit) Floor Mounted type suitable for Out Door Installation with canopy and for 100% Fresh Air application (TFA), Double Skin Casing consist of Outer Skin of 0.8mm Pre-Coated GI, Inner Skin of 0.8mm Plain SS-304, Frame work consist of Thermal Break Aluminium profile with thermal barrier, insulated panels of Thickness 45mm CFC Free PUF injected (Density: 40 kg / Cu. m.), Drain tray material consist of 20 Gauge SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation, GSS Base Channel. Coil Casing / Blank offs SS-304 with Copper tube(IGT) of thickeness 0.5mm, Fins Thickness of 0.15mm of Plain Copper with hydrophilic coating 11 Nos.Per Inch. with filter : Media of Filters-Synthetic (non woven type) / Fiber Glass for (EU-13),Efficiency of Pre-filters (EU-4)-90 % down to 10 micron, Efficiency of Fine-filters (EU-7) - 99 % down to 03 micron, with Motor - EFC Squirrel Cage IP 55 Protected VFD Compatible induction motor complete as per following specification all as specified and as directed.
DX Coil: (IGT): (01 No for suitable matching capacity of VRF Out door unit (i) Coil - (ii) Coil Casing / Blank offs - SS (iii) Material of Tube - Copper, (iv) Tube Dia (mm/Inch) - 9.52mm / 3/8" O.D, (v) Thickness of tube (SWG/mm) - 25 SWG / 0.5 mm, (vi) Header Material - Copper, (vii) Thickness & Material of fins - 0.15 mm plain Copper, (viii) No. of Fins per inch (FPI) - 11/12 FILTERS :- (i) Media of filters - Synthetic (non-woven type) (ii) 90% down to 10 micron (iii) 90% down to 5 Micron FAN & MOTOR to be designed as required: Lower Tier (i) Mixing box with Motorized operation FA damper & RA damper in Al constructions with actuator. (ii) Filter section with 50 mm thick (EU-4) box type pre filter with 305mm thick (EU-5) bag type fine mounted on common GI filter frame.
(iii) Coil section with 8 row deep DX cooling coil.(2 Nos),With single distributor. (iv) Fan section with SISW Backward curved plug fan & Motor (IE-2) (vi) Motorized operation Exhaust Air damper in Al constructions, with actuator. Operating & Physical Parameters (Lower):- (i) Flow Rate- Suitable for maintaining the inside conditions (Lower Tier) (ii) STP (mmwg) - 125 (iii) Fan Type- PLUG FAN (iv) Fan Qty - 1 (v) motor Qty - 1. Upper Tier (i) Return air intake section with manually operated RA damper in Al construction. (ii) Manually operated Exhaust Air Damper in Al constructions. (iii) Fan section with SISW Backward curved plug fan & Motor (IE-2) (iv) Motorized operation Exhaust Air Damper in Al constructions, with actuator. (v) Heat Recovery wheel of suitable capacity.
Supply and fixing of MS Stand with high quality antivibration pad as per OEM Recommendation and Placing of Outdour Unit on MS Stand of C Channel for ODU all as specified and directed. Note:-Necessary PCC required for installation of AHU,Elect Panel etc deemed to be included in overall rate quoted.
M&L for Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm dia galvanised iron strip.
Supply and fixing of 125mm deep Antivibration Flexible Joints made out of imported fire retardant fabric with extruded aluminium frame/ flange on both sides for Outdoor Units & AHU.
Supply and installation of Pan type Humidifier of suitable cap for OTs AHU for humidification made from SS-304 sheet in welded construction, inlet, drain and steam outlet nozzle, 25 mm thick fibre glass wool (150 Crown) and cladded with 22 Gauge GI Sheet . Controls comprising of low level switch float valve with SS ball, site glass, high temp cut out thermostat, digital humidistate with necessary wiring with copper bus bar connector.
Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including provision of 40 mm GI Tubing, light grade and watering pipe shall be 20 mm bore GI light grade including excavation & earth work, PCC pit with CI cover, Charcol, salt, funnel, wire mesh, GI strip Up to 7.5 mtrs length complete all as specified and directed. Testing Report of earthings shall be submitted by the contractor and no extra shall be payable on this account. (Two number earthing for each system)
Supply, installation, Commissioning and Testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase + Double RPM, 5ft -Euronics, Max air velocity at Nozzle- 21 m/s, Noise Level db - 50-70, No of blowers - 05, No of motors - 03, No of shafts - 02 double wattage - 570watt, blower type - ABS, flow rate - 1380 CFM complete all as specified and directed. Note. Technical specs as given are tentative and shall be as approved by GE.
Supply, installation, testing/ commissioning of cubical compartment type wall mounted electrical control Panel for AHU starter, strip heaters banks and Pan Humidifier as per OEM recommendation complete all as specified and directed.
Suppy and installation of Laminar Air Flow (LAF) system direct flow from ceiling to floor. The flow passing over head and upper body of surgeon and assistant made out of aluminium powder coated made of 16SWG, particle size retention of 0.3 mm , PLENUM size 8'x6' complete with HEPA filters of size 610 x610 x 305 mm and SS-304 perforated grilles having minimum 50% perfortation entry of air to housing shall be from side center of plenum shall be blanked off for lightening provisions.
Note:- The above said Description of Ser No 6.05 to 6.34 is aplicable for 6.02 to 6.04
OLD DUCTING MODIFICATION & DISMANTALING WITH INTEGRATION OF HVAC & TOUCH SCREEN CONTROL PANEL. OLD OT LIGHT & LAF DISMANTALING Ducts shall be straight and smooth and shall have neatly finished joints. All joints shall be made air tight using 5mm neoprene rubber gaskets, and/or RTV-sealed, or soldered as specified. The gasket will be fixed with a suitable adhesive to the flange. Changes in dimensions and shape of ducts shall be gradual. Curved elbows, unless otherwise approved, shall have a center line radius equal to one and a half times the width of the duct. Air turns shall be installed in all abrupt elbows and shall consist of curved metal blades or vanes, arranged to permit the air to make the turn without appreciable turbulence. Turning vanes shall be invariably provided at all turns and grille-collars. Splitters and dampers shall be provided at all branches/tapings whether shown on the drawings or not. 0.6 mm PCGI Frame construction should be used. All HVAC should be calibrated with the Touch screen control panel installed in the OT. It should operate with the help of the remote fitted inside the OT. Also Dismantal the existing old OT Lights. It will comprises of followings: (a) Supply and installation of Laminar Air Flow (LAF) system Factory Fabricated direct flow from ceiling to floor. The flow passing over head and upper body of surgeon and assistant made out of aluminium powder coated made of 16SWG, particle size retention of 0.3 mm , PLENUM size 8'x6' complete with HEPA filters of size 610 x610 x 305 mm, SS perforated grill and SS-304 perforated grilles having minimum 50% perfortation entry of air to housing shall be from side center of plenum shall be blanked off for lightening provisions -01 No. (b) Supply, installation, Commissioning & Testing of UL-555 motorised fire dampers complete with smoke detector & Smoke panel/ thermister linkage etc. in AHU Room Supply Air Ducts as required for operation complete all as specified and directed-01 No. (c) Supplying and fixing fire retardant non porus double flexible canvas connection between AHU & ducts-01 No. (d) Supply and installation of factory fabricated Alumimium Return Air Riser complete with pre-filters 610 mm x 610 mm x 50 mm and Aluminium Volume Control Damper -01 No.
Note for Ser item No 6.00 to 6.35:- Note 1. (a) Contractor/bidder should submit complete design of New AC plant comprising of heat load calculations, size of pipe, size of AC duct, AHU, LT Panel, control cable, LT switch gear which shall be dully vetted by IIT/NIT before same is approved by AO. (b) Contractor/bidder will be responsible for performance guarantee of complete AC plant to achieve the inside design conditions round the clock throughout the year with overall COP of the system not less than 3 (Three).
Note 2. Contracor shall visit the site before bidding. The plant shall comprise of the BOQ Srl Item No.6.00 to 6.35.
Note 3. All the New Air Conditioning equipments are to be installed on the roof of OTs where sufficient space is available. Additional accessories required for successful operation of units are deemed to be included in overall cost quoted.
Note 4. Rates quoted by the contractor shall be for complete finished work including cost of all labour, material, scaffolding, finishing as required with tools, plants, cartage, lift, taxes, tollage, octroi, royalties etc. All works shall be executed as per drawings and instructions of Engineer-in-Charge and shall include the supply and installation at site of all the equipment, ancillary materials as specified and all such items what-so-ever which may be required to fulfill the intent and purpose as laid down in the drawings. All materials shall be as per ISI specification and with IS certification marked wherever applicable. The material shall be duly approved by Engg in-Charge before incorporation in the actual work.
Note 5. Design of LT Panel, LT Cable, Earthing upto Control Panel of each New Plant shall be submitted by contractor for approval of CWE. Cost of these equipments are deemed to be included in overall cost.
Note 6. New AC units are designed for 06 numbers of OTs. AC unit shall be designed for 100% Fresh Air.
Note 7. Complete system pertaining to this schedule shall be executed by a firm which has executed similar types of works.
Note 8. Any item left out for successful completion of work is deemed to be included in overall rates quoted by the contractor.
Note 9. Pre-despatch inspection of VRF units shall be carried out by the rep of AO within overall cost quoted.
Note 10. Central AC of existing OTs shall be delocated before connecting up new unit. Existing AC plant shall be synchronised in 04 x exisitng OTs all as specified and directed by Engineer-in-Charge. Nothing extra shall be payable on this account.
Note 11. Item of HERMATICALLY SEALED DOOR as designed for each OT shall be approved & paid separately in B/R Schedule.
Note 12. Complete system shall be tested for a period of 24 hours (Either in Summer or Monsoon season) by rep of Accepting Officer in presence of Engineer-in-Charge, rep of CWE and rep of Users. On successful testing of system, same shall be operated by the contractor for a period of six months within overall cost quoted.
Note13. There are 10 Nos of existing OTs. Out of 10 No of OTs, 06 Nos shall be provided with New AC Plant as covered in Ser Item No 01 of schedule. Balalance OTs shall be provided Air Conditioning from existing AC Plant for which all necessary modification to existing system shall be carried out by the Contractor. This item shall be measured against Ser Item No 02 of Schedule.
Note14. Contractor is responsible for designing of VRF unit (for 06 OTs) to ensure that above designed conditions are met. Nothing extra shall be payable on this account.
Less Schedule of Credit(Minus)
SOOD ASSOCIATES PVT LTD
APRAMEYA ENGINEERING LIMITED
M/S VED PARKASH GUPTA
Sant Construction Co.
A.V BUILDERS
H.P. CONSTRUCTION CO.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid