Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹26.7 L+₹1.8 L (7.35%)Rejected-AOC | L2 | Rejected-AOC Not Being Lowest | |
| 3 | L3₹28.4 L+₹3.6 L (14.3%)Rejected-AOC RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-AOC Not Being Lowest |
Tender Value
₹50.0 L
EMD Value
₹99,980
Closing Date
9 Nov 2024, 6:00 pmClosed
GE (CENTRAL) DELHI CANTT-10
GE (CENTRAL) DELHI CANTT-10
EXTERNAL AND INTERNAL REPAIRS OF NATURE INCLUDING REPAIRS TO RCC, CHAJJAS, FACIA, PLASTER WORK, STR MEMBERS LIKE BEAMS AND COLUMNS, TILING ALONGWITH REPAIR AND REPLACEMENT OF ROOF SHEET ALONGWITH REPAIR/ REPLACEMENT OF INTERNAL WIRING, DB, MCB AND MI
2024_MES_679199_1
GE/C-68/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹99,980
Yes
22 Mar 2025
11 Oct 2024
11 Nov 2024
11 Oct 2024
9 Nov 2024
25 Oct 2024
11 Oct 2024 - 25 Oct 2024
Amount
Taking down cement plaster including racking out joints hacking for key scrubbing down with water etc on walls and ceiling up to two storey bldg all as specificed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete.
M&L Rendering 10 mm thick in CM 1:6 on other than fair finished of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified.
M&L for preparation of newly plastered surfaces of walls and providing and applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge.
M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper one coat of putty complete all as specified.
M&L for old decorated surfaces plastered or unplastered surface of wall and complete removal of existing treatment by rubbing , brooming down, washing with water etc applying two coat of oil bond distemper on wall complete all a specified.
M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by rubbing , brooming down, washing with water etc to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge.
Dismantling of wall and ceiling/cup board board fibre pulp AC boards etc any thickness including cover fillets removing the wiring .
M and L Providing & Fixing False ceiling with semi perforated 12mm thcik micro tegular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and pattern having moisture content less than 2%,humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 475 (part-4)-1970 and light reflectance of 85% minimum to be laid in true horizoatal level suspended on interlocking metel T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm, vross-T of size 15x32mm of lenght 1200mm amd secondry itermediate cross-T of size 15x32 of lenght 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items wire (galvanising @ 80 grams per sqm) with suitable double folded hanging wire up to 1000mm length and fix up in the main runner T section at every 1200mm or less than that if required as per direction by Engineer-in-charge. Further the work shall be carried out as per specification drawing and as per directions of the Engineer -in- charge.
S&F 1.6 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc., all as directed.
M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks, old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed.
Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame).
Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame).
M&L Mild steel frame work as in door chowkhats with angle iron welded together ends of angle shouldered and fixed to opening and welding 3 Nos mild steel butt hinges 100 mm size, and 6 nos hold fasts made out of FI 25x3 mm 30 cm long for fixing of chowkhats( Butt hinges paid sep) all as specified.
M&L aluminium alloy powder coated windows including aluminium coated frames sliding track, bottom weighing not less than 1.015 kg/Rm ,sides and top not less than 0.826 kg/Rm double riveted and 0.55 kg/Rm for window shutter with one fixed glazed shutter and two nos glazed/gauged shutter sliding type with aluminium sections as per series-A (15mm) 3 track of Jindal section number for sliding windows with framed shutter including aluminium allow powder coated snap type beads handles with locking arrangement spring action and glazing clips joint cleats rubber gaskets etc including provision of 5.5 mm thick tinted frosted glass of superior quality and stainless steel jail including all standard fittings complete all as specified and directed.
S & F mild steel framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, framework of water tanks and similar work including aldrop and hinges holdfast etc conforming to Fe 290. Gde-E-165.
Supply only MS butt hinges medium weight 100 mm size fixed with MS screws.
S&F MS barrel tower bolt extruded section 150 mm long and fixed with MS screws.
S&F in repair 150 mm MS pressed handle oval type stove enamelled black and fixed with mS screws.
S&F in repair 300 mm Mild steel sliding door bolts,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed and nut.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
M&L preparation of Old or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified.
Dismentling asbestos cement corrugated or semi corrugated sheets in roof fixed with L hook or cranked bolt.
S & F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M & L for 75 mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished complete all as specified.
M & L for 50 mm thick cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in floor & surfaces finished even and fair using extra cement, complete all as specified.
Demolition of reinforced cement concrete in any position all as specified and as directed by Engineer -in-Charge.
Material and labour for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in roof slabs, slab supported on walls, cooking platform, beams and columns, in floors roofs, landings, balconies, canopies and in chajjas, parapet, shelves and the like complete all as specified and directed.
Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
S&F TMT steel bars of 10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed.
M&L for 18-20 mm Granite (any type) work (table rubbed and polished) in steps,jambs,pillars window-cill,cooking platforms and incl 15mm thick screed bed using marble dust with admixture in CM (1:4) with pointing and white cement (1:2) of pigment to match with shade of granite all as spd.
Demolition of concrete and pavings n.exc 15 cm thickness (below or above ground level)
M&L for cement concrete type D-2 1:4:8 (40mm graded aggreate) filling and mass concrete.
M&L for machine pressed precast concrete interlocking paver block 80mm thick M-40 grade any shape and size with grey cement and pigment.
M&L for sand filling under interlocking pavour block floor or in foundations including watering and consolidation.
M&L Providing cement concrete in coping type B-1 ,1:3:6 using 20mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified.
Dismantling wrought iron or mild steel work of any dscription not otherwise provided for complete all as specified and directed.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins , pillars, trusses , water tank stage , framed guard bars, barred iron doors, ladders, frame balusters, walk ways, railing and similar work where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
One light/fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 42 above but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
One light/Exh fan point controlled by one way switch
One bell /buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 44 above but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge
Supply and fix white cover plate with frame 2 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 3 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 4 Module omplete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge.
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge,
M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge .
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge.
M&L in replacement socket outlet 6 Amp flush button type complete all as specified and directed by Engineer in charge.
M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
M&L in replacement bell electric (dingdong) 230 volt, SP all complete all as specified and directed by Engineer in charge .
M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge.
S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge .
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen outputwith lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 25,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 25000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. .
Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge .
Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge .
Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge .
Supply and fix in repair MCB DP 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge .
Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge .
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fixing Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan fixing on 19/18mm thick ply size as per site requirement complete all as specified and as directed.
Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed.
Supply and fix in repair MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Note: Three runs of 4 sqmm cable shall be measured as one RM.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Note: Three runs of 6 sqmm cable shall be measured as one RM.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Note: Three runs of 10 sqmm cable shall be measured as one RM.
S&F plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge.
S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
S&F SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
S&F heating element of 2 KW for any type with nut bolt washer complete all as directed.
S&F heating element of 1.5 KW any type with nut bolt washer complete all as directed.
S&F replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply and fixing LED Bollard integral decorative with PMMA diffuser 10 watt of height 0.6 meter with IP 65 protection suitable for single phase 230 volts 50 HZ AC Supply including LED bulb , Poles, service wire and cement work complete all as specified and directed by Engineer-in-Charge.
Supply and fixing new generation, post top energy saving environmently friendly 25W , long life aesthetically designed with symmetrical light distribuiton spun aluminium landscape luminaire with high power LED as light sources.
S&F 35W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:65 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
M & L for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out / unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge.
S&F Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply suitable for 250/200 mm size Fresh air fan as per sample complete all as specified and directed by Engineer-in-Charge.
S&F replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed.
S&F hole fastner madeup of MS 6" long with complete nut bolt all as specified.
Schedule of Credit
M/s M M BAHL (BID ID -3156029)
SHREE RAM BUILD TECH (BID ID -3160152)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .