| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Procurement of equipments | |||||
| 1.01 | Alcohol meter
● Measuring range: Alcohol: 0 % v/v to 100% v/v
● Temperature: 0 °C to 40 °C (32 °F to 104 °F) (automatic temperature correction)
● Accuracy: Alcohol: 0.1% v/v, Temperature: 0.1 °c (0.2 °F)
● Repeatability, s.d. : Alcohol: 0.05 % v/v, Temperature: 0.05 °C (0.1 F)
● Reproducibility, s.d.: Alcohol: 0.07 %v/v,
● Ambient temperature: -10 °C to +50 °C (14 °F to 122 °F)
● Measuring principle: Oscillating U-tube technology
● Supported measuring units: Alcohol concentration in %v/v (at 20 °C or at 15 °C) or Proof, Density, Sugar/extract concentration in Brix or °Plato, Ten programmable custom-specific measuring units
● Internal Storage: 1024 measured results, 250 sample IDs, 30 measuring methods
● Power supply: Three 1.5 VLR O6 AA alkaline batteries
● Sample volume: 2 ml
● Dimension: 468 mm x 108 mm x 119 mm (18.4 in x 4.3 in x 4.7 in)
● Interfaces: Bluetooth (data transfer to a PC or printer), RFID (sample identification)
● Protection class: IP54
● Optional available accessories: Wristband, rubber protection housing for the operating panel, portable Bluetooth printer, Bluetooth USB adapter
● 3 Years Warranty | - | Nos | - | - |
| 1.02 | Digital muffle furnace
● Muffle Furnace: Temperature range Up to 1200°C : Continuous operating temp °C : 1000 °C, Temperature Accuracy: +/- 1°C (+/- 1.8°F), Volume : 15 liter or better, Construction Material: Mild steel powder coated, Insulation Ceramic fiber blanket, Fitted with Safety Device,
● Door: Insulated solid Flap door, Temperature Controller PID Controller, Programmable Termprature Controller, Display: LED Calibration certificate
● 3 Years Warranty
● Should have At least one quality certificate i.e. USFDA/CE/BIS/ERTL | - | Nos | - | - |
| 1.03 | Digital hot air oven
1. Made up of stainless steel body and adjustable trays.
2. Temperature range -ambient - 3000C
3. Control type microprocessor PID or PT 100 sensor auto tune calibration off set
4. Temperature accuracy +/- 0.50C
5. Input voltage -230 volts AV, 50Hz
6. Internal size (in cm) -w x d x h : 60 x 60 x 90
7. Shelves provided: ( S.S Trays)-3
8. Insulation - rock wool
9. Gasket - Silicon door Gasket
10. 3 years warranty
Should have At least one quality certificate i.e. USFDA/CE/BIS/ERTL | - | Nos | - | - |
| 1.04 | Electric water bath
1. Number of racks provided with Water bath unit: 12
2. Temperature range up to 100 oC
3. Electronic digital temperature controller
4. Control Panel: The equipment is provided with the thermostat control knob ,ON/OFF switch.
5. 1 years warranty
Should have At least one quality certificate i.e. USFDA/CE/BIS/ERTL | - | Nos | - | - |
| 1.05 | pH meter
1. Complete unit with electrode holder stand, double-junction glass pH electrode, ATC probe and power adapter
2. LCD display shows mode, indicators and help messages etc
3. The equipment should have the facility to perform pH calibrations with minimum of 3 different buffer solutions. It should also have the automatic buffer recognition facility (USA, NIST, user defined) and the possibility to store the calibration data with the electrode identification
4. The equipment should have the facility to simultaneously display pH value and the temperature.
5. The pH meter provided should have the following Measurement Range: pH Range : 0.0 to 14.0 Temp and Range: 0 oC to 100.0 oC or better
6. The pH meter should have the following resolution: pH : 0.01
7. Two extra pH electrodes compatible of above pH Meter
8. Buffer recognition: NIST and USA
9. Microprocessor based: Yes
10. Memory: Up to 100 data sets
11. Warranty: 03 years comprehensive warranty from date of installation
Calibration certificate from NABL approved Lab | - | Nos | - | - |
| 1.06 | Electric hot plate
● Display: LED
● Size of top plate: Approximately 10 x 10 in. or better
● Temperature range: Ambient to 400°C
● Electrical Requirements: 230 V, 50/60 Hz
● Certifications: CE
● Warranty: 3 Years
● Temperature adjustable in 1 degree increments.
● Hot Top warning system protects from accidental burns with prominent display when heating surface is above 50°C
● Raised display design protects electronics from spills.
● Automatic over-temperature protection
● Instrument must be a multinational accepted brand.
● 1 years warranty | - | Nos | - | - |
| 2Procurement of Furniture | |||||
| 2.01 | Storage Cabinet
Powder-coated steel/wooden cabinet with locking system for safe storage of chemicals and documents | - | Nos | - | - |
| 2.02 | Lab Rack/Shelving Unit
Multi-layer steel rack for safe storage of glassware and chemicals | - | Nos | - | - |