Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC QUOTED RATES LOWEST AND COMPETITIVE | |
| 2 | L2₹26.1 L+₹2.7 L (11.4%)Rejected-Finance | L2 | Rejected-Finance Quoted rates neither lowest nor competitive | |
| 3 | L3₹27.0 L+₹3.5 L (14.9%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L3 | Rejected-Finance Quoted rates neither lowest nor competitive | |
| 4 | L4₹28.3 L+₹4.9 L (20.8%)Rejected-Finance | L4 | Rejected-Finance Quoted rates neither lowest nor competitive | |
| 5 | L5₹29.8 L+₹6.4 L (27.2%)Rejected-Finance | L5 | Rejected-Finance Quoted rates neither lowest nor competitive |
Tender Value
₹44.8 L
EMD Value
₹89,520
Closing Date
18 Jun 2020, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT 10
SPECIAL REPAIRS TO INTERNAL FITTINGS FIXTURES AND EM ASSOCIATED WORKS AT HQ DELHI AREA UNDER GE EAST DELHI CANTT 10
2020_MES_347051_1
CWE/D-04/2020-21
Open Tender
Civil Works
Item Rate
180 days
Delhi Cantt
As per NIT
8 documents required · 8 mandatory
₹500
GE EAST DELHI CANTT
₹89,520
Yes
17 Aug 2020
23 May 2020
19 Jun 2020
23 May 2020
18 Jun 2020
6 Jun 2020
Amount
Taking down old unserviceable point wiring from existing conduit / batten type (light, fan, socket or power point) complete such as switches, ceiling rose, pendent holder, regulator and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing complete all as specified and directed.
Material and labour for replacement of point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and multistranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers including cutting & chasing and FRLS PVC insulated unsheathed 1.5 Sqmm copper conductor mulistranded earth wire, connecting to common earth dolly with and incl Metal flush box, modular cover plate with frame of suitable size for fixing switches/sockets etc for one light point / fan point/ exhaust fan point / circulator fan point / bell/ buzzer controlled by one 1-way switch/ bell push complete all as directed. (Note : The cost of Metal boxes and cover plates etc will be included in quoted rate.)
All as per srl item no. 2 here-in-before but with 1.5 sq mm FRLS copper wire and 1.5 Sqmm FRLS copper earth wire for one socket outet point 5 amps on the same board .
All as per srl item no. 2 here-in-before but with 1.5 sq mm FRLS copper wire and1.5 Sqmm FRLS copper earth wire for one socket outet point 5 amps on the independent board.
All as per srl item no. 2 here-in-before but with 2.5 sq mm FRLS copper wire and 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.
Material and labour for replacement of point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and multistranded copper conductor cable ISI marked in existing concealed conduit any size/type and FRLS PVC insulated unsheathed 1.5 Sqmm copper conductor mulistranded earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing switches/sockets etc for one light point / fan point/ exhaust fan point / circulator fan point / bell/ buzzer controlled by one 1-way switch/ bell push complete all as directed. :- (Note : The cost of Metal boxes and cover plates etc will be included in quoted rate.)
All as per srl item no. 6 here-in-before but with 1.5 sq mm FRLS copper wire and 1.5 Sqmm FRLS copper earth wire for one socket outet point 5 amps on the same board.
All as per srl item no. 6 here-in-before but with 1.5 sq mm FRLS copper wire and1.5 Sqmm FRLS copper earth wire for one socket outet point 5 amps on the independent board.
All as per srl item no. 6 here-in-before but with 2.5 sq mm FRLS copper wire and 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.
S & F in replacement of Modular switch 6 Amp, 1 way, 1 module size complete all as directed.
S & F in replacement of Modular switch 10 Amp, 1 way, 1 module size complete all as directed.
S & F in replacement of modular socket two-in-one, 10 Amp universal type, 02 module size complete all as directed.
S & F in replacement of modular Socket, 16 Amp, multipurpose shutter type, 02 module size complete all as directed.
S & F in replacement of Modular switch 16 Amp, 1 way, 1 module size with indicator lamp complete all as directed.
S & F in replacement of Modular bell push switch 6 Amp, 1 way, 1 module size complete all as directed.
Supply and fixing in replacement of electric bell of DINGDONG type, 6 Amps, 240 volts, single pole and making all necessary connections complete all as directed.
S & F in replacement of Modular Fan regulator step type, 120 watts, 2 Module size complete all as directed.
Supply and fixing in replacement of lamp holder insulated body and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as directed.
Supply and fixing in replacement of Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as directed.
Material and labour for replacement of submain wiring complete with 2 x 4.0 sqmm (nominal area) FRLS, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 4.0 sqmm as earth wire in and including PVC conduit of size 15 mm dia, medium grade and conduit fitting such as tees, bends, elbow, reducers etc complete all as directed.
All as per srl item no. 20 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with 6.0 Sqmm FRLS copper cable as earth wire.
All as per srl item no. 20 here-in-before but with 2 run of 10.0 sq mm FRLS copper wire with 10.0 Sqmm FRLS copper cable as earth wire.
All as per srl item no. 20 here-in-before but with 2 run of 16.0 sq mm FRLS copper wire with 10.0 Sqmm FRLS copper cable as earth wire.
S&F in replacement of MCB DB confirming to IP 43 - IK 09 with acrylic door, 12 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces.
S&F in replacement of MCB DB confirming to IP 43 - IK 09 with acrylic door, 16 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfacescomplete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCB C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed.
All as srl item no 26 here in before but of 40 Amps capacity and SP type.
All as srl item no 26 here in before but of 63 Amps capacity and SP type.
All as srl item no 26 here in before but of 40 Amps capacity and SPN type.
All as srl item no 26 here in before but of 63 Amps capacity and SPN type.
All as srl item no 26 here in before but of 63 Amps capacity and TPN type.
All as srl item no 26 here in before but of 100 amps capacity and TPN type.
Supply and fixing in replacement of Modular AC Socket with 32 Amps SP MCB, 230 Volts, 50Hz. Complete complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of LED tube light fitting, 22 watt. wall mounting type with and including all electric connections with two core PVC insulated, PVC sheathed copper conductor flexible cable complete all as directed.
Supply and fixing in replacement of LED mirror light fitting 12 watt and making all electric connections complete all as directed.
Supply and fixing in replacement of LED ceiling light fitting 12 watt, in round shape, surface type and making all electric connections complete all as directed.
S & F in replacement of energy efficicent LED fittings 40W LED 6K suitable for street/builing area light pressure die cast aluminium roadway luminaire with high power LEDs and HF electronic driver complete all as directed.
Supply and fixing in replacement of street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 40 mm dia size light grade complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed.
Supply and fixing of Ventilating fan 250 mm sweep plastic body type 1200 RPM including self cosing louver and making all electric connections complete all as directed. .
Supply and fixing of Ventilating fan 200 mm sweep plastic body type1200 RPM including self cosing louver and making all electric connections complete all as directed
S & F MCCB, 415 volts, four pole of cap 63/100 Amps, 16 KA, ICS ,100% ICU, with Thermal - Magnetic Release in existing DB including necessary Materials / thimble of suitable size and making connections complete all as directed.
All as per item No. 41 here in before but of capacity 125 Amps, 25 KA.
All as per item No. 41 here in before but of capacity 160 Amps, 25 KA.
All as per item No. 41 here in before but of capacity 200 Amps, 36 KA.
Supply & Fix vertical load line DB, 4 Way suitable for MCCB 200 Amps, 25KA, 3P, 440 Volts. -01 No and MCB SP - 12 Nos. Make : Legrand, Cat ref No : 420208, or eq from list incl DPX 250 electronic release, MCCB, 200 Amps, 3 Pole, 200 Amps, 25 KA complete all as specified and directed by Engr-in-Charge. Make Legrand, Cat ref No : 420208 or eq from list.
Supply & Fix vertical load line DB, 6 way suitable for MCCB 250 Amps, 36 KA, 3 Pole, 440 Volts- 01 No and SP MCB-18 Nos. Make : Legrand, Cat ref No : 507746,420249 or eq from list incl DPX 250 electronic release, MCCB, 250 Amps, 3 Pole, 250 Amps, 36 KA complete all as specified and directed by Engr-in-Charge. Make Legrand, Cat ref No : 420339 or eq from list.
S&F in replacement of Recess mounting 2x2 square flat panel ultra slim scoop LED light 36 W cool white 5600-6000K, input voltage 110-240 volt, 50 Hz with driver/transformer ect suitable for AS/GB/POP ceiling incl making electric connection complete as as directed.
S&F in replacement ceiling fan of size 1200/1400mm sweep, DC double ball earing, 5 Star rating, 240V single face 50Hz compete all as specified and directed by Engineer in Charge.
S&F in replacement of LED bulbs 7W, B 22/E14/E27 90-300V AC-50 Hz complete all as directed.
S&F in replacement of LED bulbs 9W, B 22/E14/E27 90-300V AC-50 Hz complete all as directed.
S&F Galvanised Steel Water tubing light grade of size 40mm bore complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable LT U/G cable any size and core complete all as specified.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete all as specified and directed by Engr-in-Charge.
All as per item sl No 53 but 25 sqmm, 4 core.
All as per item sl No 53 but 35 sqmm, 3.5 core.
All as per item sl No 53 but 50 sqmm, 3.5 core.
Supply and fix Industrial Switchgear Busbar Chambers, current rating 400 Amps, 4 Way with 04 Nos copper busbar complete all as specified and directed by Engr-in-Charge.
M&L PVC trunking of size 145MM X 50MM complete with all type of accessories except cover complete all as specified and directed by Engr-in-Charge.
M&L PVC trunking cover of size 145 MM X 50 MM complete with all type of accessories. complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with copper earth plate electrode 600mmx600mmx3.15mm thick buried directly in ground not less than 2.25mtrs below ground level, with top edge of the plate not less than 1.5mtrs deep below normal ground level, connected to 20x3mm thick copper strip as electrode by means of copper bolts, nuts to earth test point incl necessary PCC 1:2:4 type B-1, cover frame, GI pipe 15mm dia light grade for protection of earthing lead and GI pipe 20mm dia for watering pipe with funnel, wire mesh, salt, charcoal dust and exc complete all as specified and as directed directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out including trimming of sides complete all as directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as directed
Material and labour for brick protection to cable using old size class 'B' bricks, laid flat, dry butt jointed, laid lenthwise perpendicular to the axis of cable complete all as directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as directed.
Removal of excavated material from the MoD land complete all as specified and as directed
Material and labour cutting the exisiting PCC/bituminous road of size 20 cm x 20 cm for fixing the GI pipe and make good the disturbed surface as per existing surface complete all as specified and directed.
M&L PVC trunking of size 130mm x 50mm complete with all type of accessories except cover all as specified and directed.
M&L PVC trunking cover of size 130mm x 50mm complete with all type of accessories all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .