| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC 107 1F TOLLYGUNGE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹50.4 L+₹1.0 L (2.07%)Rejected-Finance 107 1A TOLLYGAUNG ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹52.0 L+₹2.6 L (5.25%)Rejected-Finance 34 C R AVENUE JABAKUSUM HOUSE 3RD FLOOR ROOM NO 312 KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹53.9 L+₹4.5 L (9.05%)Rejected-Finance | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹55.2 L+₹5.8 L (11.7%)Rejected-Finance | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8030/B/E8
2022_MES_502533_2
GE/ALP (8030B) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
210 days
GE ALIPORE KOLKATA
Class D and Category a (i)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹90,000
Yes
23 Mar 2022
3 Mar 2022
21 Mar 2022
3 Mar 2022
19 Mar 2022
11 Mar 2022
60 days
Amount
Chipping of unsound /weak concrete materials from slabs, beams, columns, lintel, chajja, fin, facia etc. by any means as directed by engr-in-charge including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting including foreign matrials , loose concrete/aggregate etc and disposal of all debris out of MOD land and complete all as specified and as directed by Engr-in-Charge ( upto 12 storey of building) for 25mm average thickness for slabs/Chajja
All as per Item No 1 above but 40 mm average thickness for beams/Lintel
All as per Item No 1 above but 60 mm average thickness for Column
All as per item No 1 to add or deduct for every 10 mm thickness extra for item No 1, 2 & 3 upto 12 storey. complete all as specified and as directed
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap)by manual methods (using wire brushing ,chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area throughly by water and allow it to dry all as per manufacturer,s instruction to give it a totally rust free finished steel surface complete all as specified and directed by Engr-in-charge ( Make : SIKA/FOSROC/HINDCON) any dia of bars ( upto 12 storey of building)
M & L for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufacture's instruction/specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm and complete all as specified and directed by Engr-in-charge upto 12 storey (Make : SIKA/FOSROC/HINDCON/)
Supply and application of Epoxy Zinc rich primer on the prepared steel surface of any dia of bars by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed by Engr-in-charge. Make ; SIKA/FOSROC/HINDCON upto 12 storey High.
M & L for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling,fixing the reinforcement in position using welding/epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed by Engr-in-charge. upto 12 mm dia bar (upto 12 storey High).
M & L for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling,fixing the reinforcement in position using welding/epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed by Engr-in-charge. above 12 mm dia bar (upto 12 storey High bldg.)
M & L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc . The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as spd and dir by Engr-in-charge.( Make: SIKA/FOSROC/HINDCON) 60 mm average thickness of Column,upto 12 storey High.
M & L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc . The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as spd and dir by Engr-in-charge.( Make: SIKA/FOSROC/HINDCON) 40 mm average thickness of Beam/lintel, upto 12 storey High.
All as per item No 10 but for add or deduct for every 10 mm thickness extra for item No 10 & 11 upto 12 storey. complete all as specified and as directed
Supply, mixing and application two component structural grade polymer modified reinstatement morter, where local spalling has taken place or shuttering is not possible . The morter can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2 complete all as spd and directed by the Engr-in-charge upto 25 mm average thickness and upto 12 storey High. Make :- SIKA/FOSROC/HINDCON) NOTE:- Cement and sand morter in proportion of 1:2 graded coarse sand ) with polymer admixed in proportions approved by Engr-in-charge)
All as per item No 13 but for add or deduct for every 10 mm thickness extra for item No 13 upto 12 storey. complete all as specified and as directed
M & L for applying curing compound over concrete surfaces as per manufactures instruction complete all as spd and dir by Engr-in-charge upto 12 storey high bldg. Make :- SIKA/FOSROC/HINDCON
M&L for hoisting, assembly and fixing of double layer steel scaffolding to external perimeter of building duly cross braced and properly aligned for the functional aspect and safety of the building including dismantling, shifting & removal from site complete all as specified and as directed by the Garrison Engineer / Engineer-in-Charge.( upto 12 storey high building) Note: - Elevational area of the building shall be measured for payment of scaffolding.
M&L for use and waste of formwork to sides of column, pillars, posts, stanchions for rough foinished surface complete all as specified and as directed by the Engr-in-Charge.(upto 12 storey of building)
M&L for use and waste of formwork to sides and soffit of beams, lintels, cantilevers, shelves etc for rough finished surface complete all as specified and as directed by the Engr-in-Charge. .(upto 12 storey high of building)
M&L for use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railing horizontal or sloping and similar work exe 5 cm but not exe 10 cm thick completeall as specified and as directed by the Engr-in-Charge. .(upto 04 storey High of building)
M&L for use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surface complete all as specified and as directed by the Engr-in-Charge. .(upto 12 storey of building)
Demolition of cement concrete of any description and in any position not otherwise specifically provided for .(upto 12 storey High of building)
Demolition of reinforced cement Concrete(reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for etc complete all as specified and directed.
M&L for RCC (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) as in chajjas, similar work complete all as specified and directed (upto 12 storey high building)
M&L for 25mm thick Cement concrete (1:2:4), type B-0 (using 12.5mm graded stone aggregate) for floor to receive floor finishes etc complete all as specified and directed. Upto 12 storey.
M&L for 75mm thick PCC (1:3:6), type C2, (using 40mm graded stone aggregate) as in plinth protection / paving, surfae finished even & smooth without using extra cement as complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (upto 12 storey High of building)
Demolition of Brickwork quoins,arches,pillars etc but excluding ashlar facings,dressed all store work and precast concrete articles built in cement mortar.(upto 12 storey High of building)
M&L for brick work with sub class 'B' bricks built in cement mortar (1:6) straight or curved on plan exceeding 6 mtr mean radius and complete all as directed.(upto 12 storey High of building)
M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) .(upto 012 storey High of building)
Taking down cement plaster including raking out joints, hacking for key, scrubbing down with water etc including necessary scaffoldings complete all as specified and as directed by Engr-in-Charge.
M&L for Rendering 10mm thick in cement mortar (1:3) on fair faces of ceiling and finish smooth without using extra cement including necessary scaffoldings complete all as specfied and directed.
M&L for Rendering 15mm thick with cement mortar (1:6) on brick work or concrete surfaces finished even and smooth without using extra cement including necessary scaffoldings complete all as specified and as directed.
All as per item No 32 but in cement mortar (1:4) complete all as specified and as directed.
M&L for one coat of white wash on old decorated surface of wall including preparation of surfaces and necessary arrangement for working platform complete all as specified and directed (upto 12 storey bldg).
All as per item No-34 above but on ceiling
M&L for one coat of acrylic distemper (white or coloured as per site requirement) on old decorated surface of internal walls including preparation of surfaces and necessary arrangement for working platform complete all as specified and directed (upto 12 storey bldg). Note : No separate payment shall be made for colour of distemper where required or directed by Engineer-in-Charge. Cost is included in unit rate.
All as per item No 36 above but in ceiling.
M&L for one coat of synthetic enamelled paint on old decorated wooden surface exc 10cm width or girth including preparation of surfaces and necessary arrangement for working platform complete all as specified and directed (upto 12 storey bldg).
All as per item No-38 but on old decorated steel surface.
M&L for one coat of weather proof exterior emulsion paint (white or coloured as per site requirement) on old decorated surface of of external walls including preparation of surfaces to remove all foreign materials and necessary arrangement for working platform complete all as specified and directed (upto 12 storey bldg). Note : No separate payment shall be made for colour of paint where required or directed by Engineer-in-Charge. Cost is included in unit rate.
M&L for two coat of weather proof exterior emulsion paint (white or coloured as per site requirement) on new or previously untreated surface of external walls over one coat of primer including preparation of surfaces and necessary arrangement for working platform complete all as specified and directed (upto 12 storey bldg). Note : No separate payment shall be made for colour of distemper where required or directed by Engineer-in-Charge. Cost is included in unit rate.
M&L for complete removal of existing treatment on walls including washing / rubbing down with water and applying two coats of acrylic distemper (white or coloured as per site requirement) over three coats of wall care putty 3mm thick and a coat of primer including necessary arrangement for working platform complete all as specified and directed (upto 12 storey bldg). Note : No separate payment shall be made for colour of distemper where required or directed by Engineer-in-Charge. Cost is included in unit rate.
M&L for applying 3mm thick wall care putty (each layer n.exc 1mm thick) on new plastered surfaces etc including necessary arrangement for working platform complete all as specified and directed (upto 12 storey bldg).
Material & Labour for two coat acrylic distemper (white or coloured as per site requirement) over one coat of priming chalk whiting on new or previously untreated plastered surfaces including preparation of surface and including necessary arrangement for working platform complete all as specified and directed (upto 12 storey bldg). Note : No separate payment shall be made for colour of distemper where required or directed by Engineer-in-Charge. Cost is included in unit rate.
M&L for preparation of new or previously untreated surfaces of wall and applying two coats of white wash including necessary arrangement for working platform complete all as specified and directed (upto 12 storey bldg).
All as per item No-45 but on ceiling.
Dismentling floor hearth or wall tiling including cement mortar bedding (But not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. (upto 12 storey)
Material and labour for glazed ceramic tiles coloured on vertical surface 450X300X7mm thick, over and including 10mm thick rendering in cement mortar (1:4) set and jointed in neat cement slurry and pointed in whire or coloured cement to match, complete all as specified and as directed (upto 12 storey bldg).
Material and labour for coloured non skid ceramic tiles 7-8 mm thick (square/rectangular), area of each tiles exc 0.11 Sqm but n exc 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer of cement mortar (1:6) finished even and rough to receive the top layer. complete all as specified and as directed (upto 12 storey bldg)
M&L for light shade Vitrified ceramic tiles 10 mm thick (Square/ rectangular) Polished, area of each tiles n.exc. 0.36sqm, in floors etc. set and jointed in neat cement slurry over and including a bedding layer of scread bed 15 mm thick iln cement mortar (1:6) and pointed in white/colour cement to match complete all as specified and as directed. (upto 12 storey High of building).
Material and labour for Granite (of any type) 18-20mm thick slab laid on floor machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15 mm thick screed bed in cement mortar (1:6) including grinding & polishing complete. complete all as specified and as directed (upto 12 storey bldg).
All as per item No 51 above but on wall skirting /dado over and including 10mm thick cement mortar (1:4) complete all as specified and as directed (upto 12 storey bldg).
S&F PVC Panelling 5 mm thick any size fixed in wall & ceiling including corner tapping fixed water proof ,including fixing of lights points compltete all as specified and directed.
M&L in repair suspended false ceilling system using chicogo metalic (E grid) exposed suspende system, grid section size 600mm x 600mm comprising of GI powder coated main runner of dimension 39 mm x 24mm x 0.80mm thick ( thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of Runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X 24mm x 0.8 mm thick wall angle 22.2mm x22.2mm x 0.65 mm thick ( thickness comprising of GI/0.35 + PPPCGS/0.3 mm & Weight of angle 0.70 kg for 3050 mm length) with and including 4mm thick HPSC ( High pressure steam cured) pre- primed, self embossed textured designer board, water resistant termite resistant, fire resistant for insulation and accustic purpose to be placed in the grid system duly suspended with 2 mm dia G I bars hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips (Wt- 0.007 Kg/clip) hold down clips (Wt - 0.0035 Kg/clip) with Provn of light fixture including taking down u/s one, complete all as specified and directed. Make- EVEREST or other equivalent as approved.
Supply, hoisting and fixing in proper position 500 ltr capacity ISI marked multi-layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), with connecting to solar water heating system after and including dismantling of existing unserviceable water storage tanks upto 12 storey of bldg, complete all as specified and as directed by the Engr-in-Charge.
All as per item No 55 here-in-before but 1000 ltr capacity
All as per item No 55 here-in-before but 2000 ltr capacity.
M&L for resecuring or easing and adjusting wooden door shutter/ window shutter of any type without taking down shutters complete all as specified and as directed.
M&L for resecuring or easing and adjusting aluminium or wooden door shutter/ wooedn window shutter of any type without taking down shutters including clean dust, concrete from window cill bottom and top and use grease and oil for easy functioning of shutter complete all as specified and as directed.
M&L for easing / adjusting of steel windows and oiling/ greasing for smooth functioning complete all as specified & directed by the Engg-in -charge .
S&F in repairs 15mm bore Brass CP wall mixture for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and as directed.
Taking down eaves gutters and rain water pipes ,cast iron pipes(any size or pattern), including all fittings, heads, shoes, bends, swan-necks, reinforced concrete drain pipes etc., including cleaning or refixing or removal to Store (measured overall length as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
Supply and fixing PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints and fixed to wall complete all as specified and as directed.
Supply and Fixing 110 mm bore PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specified and as directed.
Supply and Fixing 110 mm bore PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface complete all as specified and as directed.
Supply and Fixing in repair 100 mm bore cast iron (spun) soil waste pipes, in any length with or without ears, with cement joints, fixed to walls with MS flat iron hook including cutting holes on wall and finished the surface with PCC (1:2), type B-0 complete all as specified and as directed.
All as per item No 66 above but branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors complete all as specified and directed.
All as per item No 66 above but bends.
Supply and Fixing cast iron cowls, bore of pipe 100mm complete all as specified and as directed.
S&F in repair CPVC pipes 50 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor, etc. including taking up/down unserviceable 50mm dia CPVC pipe and suitable working platform upto 12 storey of bldg complete all as specified and directed.
S&F CPVC Tank Adaptor of 50 mm outer diameter including suitable working platform upto 12 storey of bldg complete all as specified and directed.
S&F CPVC UNION of 50 mm outer diameter including suitable working platform upto 12 storey of bldg complete all as specified and directed.
S&F in repair CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor, etc. including taking up/down unserviceable 20mm dia GI/25mm CPVC pipe and suitable working platform upto 12 storey of bldg complete all as specified and directed.
S&F 25mm MTA/MBTA complete all as specified and directed
S&F 25mm FTA/FBTA complete all as specified and directed
S&F in repair CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as concealed/or surface wiring in walls, ceiling, floor, etc. including taking up/down unserviceable 15mm dia GI/20mm CPVC pipe and including suitable working platform upto 12 storey of bldg complete all as specified.
S&F CPVC 20mm bore Brass elbow complete all as specified and as directed
S&F CPVC 20mm Brass Tee complete all as specified and as directed
S&F CPVC 20mm MTA/ MBTA complete all as specified and as directed
S&F CPVC 20mm FTA/ FBTA complete all as specified and as directed
S&F CPVC 20mm Brass Elbow (3/4 X ½) complete all as specified and as directed
S&F CPVC 20mm extension piece 75mm long complete all as specified and directed.
S&F CPVC reducer Tee (2" X 3/4") complete all as specified and as directed
Refixing of 20 mm outer dia CPVC/GI/UPVC pipe and connection in new or old position including new fitting after and including taking up or down the pipe and connection including cleaning upto 12 storey of bldg complete all as specified and as directed.
All as per item No 84 above but 25mm bore.
S&F in repair vitreous china wash down water closet (Pedestal) including PVC seat closed pattern with flat bottem and cover and mild steel chromium plated hinge device, connection to drain or outgoing pipe and to flushing pipe, antisyphonage pipe joint to socket or stoper etc. complete all as specified and as directed
S&F in repair vitreous china wash hand basin, white, flat back, size 550mm x 400mm, excluding chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed.
S&F in repair PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe (Long bend) 32mm dia of make as approvrd by GE complete all as specified and directed.
S&F in repair 15mm bore CP angular valve,with crutch handle, screwed for iron pipe or for brass ferrule and fixed of following size complete all as specified and directed
S & F in Repairs 15 mm Dia CP Bib taps, with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed .
S & F in Repairs 15 mm Dia CP stop cock(cocealed type) , with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed .
S&F in repair 15 mm bore CP pillar taps, with capstan heads, chromium plated, Fancy type screwed down for pipe, high pressure ,complete all as specified and directed.
S&F in Repairs CP Towel rail 900 mm long 20mm dia fixed with and including chromium plated brass screws & wooden/plastic cleats.
S & F in repair stainless steel toilet paper holder fixed with CP screws in wall ,complete all as spd and directed
S & F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S & F in repairs Aluminium body door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851-1000 mm in width & weight between 61 to 80 Kg.
S&F in repair for 25 mm curtain rod fancy type Mild steel chromium plated with fancy brackets and knobs complet all as specified and directed.
S & F in repair 3mm thick sheet glass , pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane including hacking out from wooden/metal frame, complete all as specified and directed.
S & F in repair stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanized wire staples including of dismentling complete all as specified and directed by Engr in charge..
S&F in repair 5 mm thick beveled edge best quality looking mirror of size 600x450 mm fixed with screws complete all as specified and directed.
S&F in repair CP Health faucet with all necessary fittings.
S&F in repair Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including unserviceable one. complete all as specfied and diected. (Height of bldg upto 12 storey)
All as per item No 102 but without glazing bar complete all as specified and as directed.
S&F Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 (Height of bldg upto 12 storey)
S&F in repair Steel ventilator with top hung shutter including hinges, steel peg stay, including taking down unserviceable one.complete all as specified and directed. (Height of bldg up to 12 storey)
M&L for preparation of new steel surfaces over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
S&F 3.00 mm sheet glass, ordinary quality and glazing with oil putty in Square n. exc 0.50 Sqm in each pane complete all as specfied and diected.
All as per Item No-107 above but in Figured glass at any position complete all as specfied and diected.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specfied and directed.
Taking down chokhat with shutter (without taking down shutters from the frame) n.exc 1.5 sqm complete all as specified and directed.
S&F factory made solid panel PVC door frame of size 50mmx47mm out of 5mm plain colour PVC sheet reinforced with M.S Square tube, all as per specification and drawing.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with heat molded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for top rail and bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/seated to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site as per specification and drawing.
Taking down chokhat with shutter (without taking down shutters from the frame) exc 1.5 sqm but n.exc 4.0 Sqm complete all as specified and directed.
All as per item No-113 but refixing the door in same poening after repair.
S & F Second class hard wood (Sal) plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints.
S & F 30 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F, 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Taking down shutters of any description exceeding 1 Sqm and n. exc 2 Sqm each at any storey of building complete all as specified and directed.
M & L for Cub-boards shutters and shelf made with 18/19mm thick Block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face, fixed with screws to timber frame-work including 6mm teakwood lipping complete all as specified and directed upto 12 storey of bldg.
S & F Continuous (Piano) hinges, mild steel, bright finished or electro galvanized, width of flaps (When open) 30 mm at any storey of building
S&F 100mm stainless steel Butt hinges, medium weight and fixed complete all as specified and directed.
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
All as per item No 122 above but 125mm.
All as per item No 122 above but in repair
S&F 150mm long aluminium anodised barrel tower bolts of extruded section.
All as per item No 125 above but 100mm.
All as per item No 125 above but in repair
S&F 300mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet,cast or extruded section and fixing bolt of extruded section or cast aluminium alloy and fixed.
All as per item No 128 above but in repair
S&F 140mm long Floor door stopper of brass body and tongue with hard drawn steel spring , fixed in floor complete all as specified and directed.
Supply and Fixing in repairs mortice lock vertical type size 100 mm Brass 4 lever for wooden door complete all as specified and as directed.
S&F MS flat iron as in hold fast and similar work as specified Gde Fe 410-0 or Fe 310-0.
M&L for PCC (1:2:4), type B1 (using 20mm graded stone aggregate) for fixing hold fasts, angle etc.
S&F in repair of stainless steel brackets of size 75mmx30mmx1mm thick for 15mm/20mm external dia curtain rail complete all as specified and directed.
S&F in repairs for Powder coated aluminium sliding windows for three track with rubber gasket, stopper powder coated aluminium standard beads/glazing clips ,locking arrangement etc and aluminium frame of size 80mmX25mmX1.55mm and shutter of section 20mm X20mm X1.55mm incl ( two shutter of 4.8mm thick glass and one shutter of stainless steel wiremesh 0.36 mm dia of wire and average width of aperture 1.40 mm) including aluminum chequered grill with mesh size 75mm x 75mm with necessary all fittings complete all as per manufacturer's instructions and all as specified and as directed by the Engr-in-Charge.
S&F for Providing precast cement concrete (1:2:4), type B-0 (using 12.5mm graded stone aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings set in cement mortar (1:4) including demolition of unserviceable one complete all as specified and directed upto 4 storey high of building including necessary scaffolding etc.
Grubbing up and uprootinng of trees / plants of any height and girth from external walls of bldgs upto 12 storyed height pouring muratic acid for burning risidual roots in any . Racking out the dead roots from plants / concrete joints upto its penetrated portion and filling with PCC (1:2:4) (using 12.5 mm graded stone aggregate) and finishing the surface with 15mm rendering in cement mortar (1:4) including necessary hanging arrangement complete all as specified and as directed.
ARJUN DAS VALECHA
Tirupati Buildcon Pvt. Ltd.
PINKY CO.
TOTCO
M/S J S ENTERPRISES
M/S AVIJEET INTERNATIONAL
R.R.ENTERPRISE
dutta and dutta
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .