Loading…
Loading…
Updated dates
Tender Value
Refer Docs
EMD Value
₹51.1 L
Closing Date
9 Apr 2026, 3:00 pmClosed
SE Construction Circle UP jal Niga (Urban) Jhansi
Office of Superintending Engineer, Construction Circle, Jhansi
Nagar Panchayat Kulpahad Re-organization Water Supply Scheme
2026_UPJNM_1122186_1
341/F-03/52 date 28-02-2026
Open Tender
Water Supply
Kulpahad
Please refer Tender documents.
2 documents required · 2 mandatory
₹23,600
EE CD UPJN (Urban) hamirpur
₹51.1 L
SE Construction Circle UP jal Niga (Urban) Jhansi
6 Mar 2026
6 Mar 2026
9 Apr 2026
6 Mar 2026
9 Apr 2026
6 Mar 2026
16 Mar 2026
CIVIL WORKS
WTP works
Survey, Investigation, Soil Testing, Planning, Design and Drawing construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevant latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be Vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractor's cost. For construction of 9.00 MLD WTP on latest technology, Admin Building with Command Control Room, and fire fighting arrangements, first aid arrangements Cascading Aerator, Inlet chamber, alum dosing, pre-sedimentation Tank/Rapid Mix/Vertical Flow Clarifloculator/Rapid Gravity Filter with Back Wash Arrangement/Proper Sludge Disposal and Backwash water disposal arrangements to nearest drain/low laying area& Appurtenant Works of the above-mentioned capacity, automated through PLC with outputs to SCADA, walkway in between WTP components with railing, Guard Room, Chemical Store House, Gaseous Chlorination Plant, Development of WTP area with adequate plantation, Rainwater harvesting unit. Lean concrete to be used of grade not less than M-15 and other structures in minimum M-30 grade of concrete. Cement and steel should be as per approved by the Engineer/IS code. Collapsible MS steel doors and aluminum windows to be provided including of three-coat whitewashing, internal two coat white cement painting, external painting with apex ultima/equivalent paint, all steelwork must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification with adequate LED lights for the compound, including automation, instrumentation & SCADA, wireless telemetry (voice & data), including Water Testing Kits, Lab Building and essential lab equipment as mentioned in the related Items Including of supply of all materials, labor T&P etc required for proper completion of works as per direction of the Engineer. All works complete as per design and drawing approved by engineer incharge. contractor will have to provide four wheelers, two wheelers, with fuel & driver for supervision of work and computer/laptop with operator as mentioned in tender document.
INTAKE WELL WORKS
Rising Main & By Pass arrangement
Supply of following sizes of DI pipes, class K-9 with rubber gasket, conforming to IS: 8329/2000 (reaffirmed year 2020) or its latest amendments, F.O.R. destination including insurance etc. complete
350 mm dia D.I. Class K-9
250 mm dia D.I. Class K-9
150 mm dia D.I. Class K-9
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
Carting, laying and jointing of the following sizes of pipes into the trenches including cost of all jointing materials, labour and T&P, testing etc. complete. All works complete as per design and drawing approved by engineer incharge
350 mm dia D.I. Class K-9
250 mm dia D.I. Class K-9
150 mm dia D.I. Class K-9
Excavation for pipe line trenches in Ordinary soil,(lime, clay or sand including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m from the center of the foundation trenches.
From Intake Well to WTP
Ordinary soil
Ordinary rock (mixed with kankar)
Hard rock (requiring blasting)
Hard rock (blasting prohibited)
Supply of following sizes of C.I. D/F sluice valves as per I.S. 780- 1960 tested to 10 Kg/sqm fixing in pipe line trenches, jointing and testing complete.
350 mm dia
250 mm dia
150 mm dia
Supply of C.I. Air valve
Carting of D/F sluice valves of following sizes to the site of works lowering them into already prepared trenches and fixing them in position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc.complete excluding values and specials required but including the testing etc. complete.
350 mm dia
250 mm dia
150 mm dia
Air Valve
Supply of all materials, labour, T&P and construction of following chambers as per type design including supply and materials, labour and T&P, testing etc. complete.
Masonry Type
Air Valve chamber
Provision of Thrust block
350 mm dia
250 mm dia
150 mm dia
Dismantling and reinstatement of following type of road surfaces for lying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
C.C. Road
Crossing of Culvert/ Nala for laying pipe line including supply and materials labour, T&P etc. complete.
Nahar Crossing (20M)
Crossing of road for laying pipe line including supply and materials labour, T&P etc complete.
Crossing of culvert/nala for laying pipe line including supply and materials labour, T&P etc complete.
Charges payable to PWD for permission of crossing Roads.
Charges payable to Forest Department for permission of crossing Roads.
Distribution System
Excavation for pipe line trenches in Ordinary soil,(lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m from the center of the foundation trenches.
Ordinary rock (mixed with kankar)
Hard rock (blasting prohibited)
Supply of the following sizes of pipes confirming to I.S. 4984:1995, I.S.-8329/2000 latest relevant of I.S.S. with couplers etc complete in all respect F.O.R. destination including all taxes and insurance.
HDPE Pipe PN-10 (O. D.) PE-100
110 mm dia
140 mm dia
160 mm dia
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
HDPE Pipe PN-10 (O. D.) PE-100
DI Pipe K-7
200 mm dia
250 mm dia
300 mm dia
350 mm dia
400 mm dia
Addition (DI K-7) Pipe for connecting overflow to main supply
400 mm dia
Addition (DI K-7) Pipe for connecting overflow to main supply
350 mm dia
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
DI Pipe K-7
Carting from the store (up to 8 Km.) The following sizes of pipe and specials to the site of work lowering them in to trenches and laying true to alignment and gradient including jointing, testing of pipeline and including supply of jointing material such as nut & bolts, rubber insertion, white lead etc. complate but excluding cost of trenching and cutting of pipes etc. Formaking of lengths but including making joints. All works complete as per design and drawing approved by engineer incharge. HDPE pipes shall be joined by electrfusion welding fittings and welding equipement, ensuring proper surface preparation,alignment and cooling time.
HDPE Pipe PN-10 (O. D.) PE-100
110 mm dia
140 mm dia
160 mm dia
DI Pipe K-7
200 mm dia
250 mm dia
300 mm dia
350 mm dia
400 mm dia
Addition (DI K-7) Pipe for connecting overflow to main supply
400 mm dia
Addition (DI K-7) Pipe for connecting overflow to main supply
350 mm dia
Supply of following types of fittings including railways freight, cartage up to store, all taxes and duties complete.
C.I. Double flanged Sluice /Scour Valves as per I.S. 780/1969 class-1 working pressure 10 Kg/sqm F.O.R Destination including all taxes and insurance.
C.I. Double flanged Sluice Valves
Scour Valves
80 mm dia
Air Valves
Fire Hydrants
Carting of following fittings of following sizes to the site of works lowering them into already prepared trenches and fixing them in position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testingetc. complete excluding values and specials required but including the testing etc. complete.
C.I. Double flanged Sluice Valves
Scour Valves
80 mm dia
Air Valves
Fire Hydrants
Supply construction of following chambers as per type design including supply and materials labour, T&P etc. complete.
Masonry Type
Air Valves
Fire Hydrants
Dismantling of following type of surface including sorting out and staking of serviceable materials and disposal of unserviceable material up to a distance of 50m.
B.O.E. ROAD 60% old bricks
Bituminous Road
CC Road
Inter locking Road
Reinstatment of following type of road including supply of all material, labour etc complete. All works complete as per design and drawing approved by engineer incharge
B.O.E. ROAD 60% old bricks
Bituminous Road
CC Road
Inter locking Road
Crossing of Culvert upto 3.5M for laying pipe line including supply and materials labour, T&P etc. complete.
Crossing of Culvert 3.5M to 7.0M for laying pipe line including supply and materials labour, T&P etc. complete.
Crossing of Road for laying pipe line including supply and materials labour, T&P etc. complete.
3.5 M wide Road
7.00 M wide Road
Charges payable to PWD for permission of crossing Roads.
House connection on New Pipeline
Provision of House connection including Supply of all materials, labours T&P etc required for proper completion of work. (as following)
Making House Connection with distribution main including dismantling of road, supply, carting of specials, Lowering them into trances, fixing them in proper alignment and jointing including bailing out to water, necessary excavation for connection including all labour, T&P etc. required for proper completion of the work. All works complete as per design and drawing approved by engineer incharge
In B.O.E. Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
For 250 mm to 300 mm dia
In Bituminous Road
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
For 250 mm to 300 mm dia
For 350 mm to 500 mm dia
In C. C. Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
For 250 mm to 300 mm dia
For 350 mm to 500 mm dia
In C. C. Interlocking tiles Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
For 250 mm to 300 mm dia
For 350 mm to 500 mm dia
In Earthen Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm to 250 mm dia
For 250 mm to 300 mm dia
RCC MCWR Cum Pump House
Capacity of MCWR 700 KL
Provision for soil testing
RCC OHT Zone-II
Testing of bearing capacity of soil from a reorganized Govt. Engineering college or as directed by department.
RCC OHT Zone-III
Testing of bearing capacity of soil from a reorganized Govt. Engineering college or as directed by department.
REPAIRING OF TWO NOS. EXISTING CWR/OHT (375 Kl &450Kl) (ZONE-I)
Supply and fixing on lightening Conductor on O.H.T. with proper arrangement and alignment including all labour and T&P etc. complete.
The lightening conductor consisting of an elevation rod, down conductor and earth plate shall confrom with the standars as required by the Electircal Inspector of U.P from time to time , Any amendment , addition etc. suggested or required by the Electircal Inspector shall be carried out.
Water lavel Indicator
Supply and fixing of water level indicator with suitable arrangement as per latest I.S. code with all labour T&P etc. complete.
All exposed surface of structure to be given three coats of approved exterior cement paint Berger/ narolac / Asian ( Such as apex) to give a smooth and even colour. the pipe system of above aprorn level along with the clamps to be painted with three coats approved synthetic paints. including supply of all labour material T&P necessory Scafolding etc. complete.
Repairs of O.H.T. wall, water tighteing work including all labour, material etc required for completion of work.
Repairs of cracks on concrete OHT including all labour material extraholding etc required for completion of work.
Repairs & Replacement of OHT pipes & Specials including all labour, material etc required for completion of work.
Repairs & Replacement of Valves & carting including all required for completion of work.
Replacment of both M.S. Ladder (inner & outer) & MS cover on top dome including all labour, material etc required for completion of work.
Site clearence and other unforseen items.
REPAIR OF EXISTING BOUNDARY WALL (ZONE-I)
First class brick work in 1:4 cement and local sand mortar in super structure and plinth including supply of all materials, labour T&P etc required for proper completion of work.
12 mm thick plaster with cement and local sand mortar in proportion of 1:6 over brick work, minimum thickness not be less than 10 mm including supply of all materials labour, T&P etc required for proper completion of work.
Provision of coping on the top of wall
Provision of barbed iron wire fencing to posts in four rows.
Provision M.S. iron angle (50x50x6mm) for the barbed wire fixing and 2 meter
Cement concrete with 20 mm gauge approved stone ballast coarse sand and cement in proporation 4:2:1 including supply of all materials, labour, T&P etc required for fixing M.S. Iron angle proper completion of work.
Raised pointing with cement mortar 1:4 consisting or cement and local sand on brick work including supply of all materials. labour, T&P etc, of the wrok.
White washing in three coat including supply of all materials, labour, T&P etc.
complete required for proper completion of the work
Providing plaster of Paris wall
to prepare the surface even and smooth complete.
Apex Ultima /Acrylic Exterior/ interior paint of approved brand & manufacturer & of required shade on under coated wall surface to give an uniform surface over one primer coat of white cement of approved brand after thoroughly brushing and rubbing the surface free from mortar droppings & other foreign matters including prepairing even surface with plaster of paris including supply of all material labour T&P etc required for proper completion
Site clearence &other unforceen item.
Existing Boundry Wall Length
Provide all materials, labour T&P etc. required for proper completion of work and construct pillars as per type design and fixing of gate 3.6 m wide gate and 1.2 m wicket gate.
Leveling, dressing, repairing of road in water works compound
REPAIR OF ONE NO. EXISTING STAFF QUARTER (ZONE-I)
Ist Class brick work in 1:4 cement and local sand mortar in superstructure including supply of all material, labour, T&P etc required for proper completion of the work. (Thickness of wall to one brick thick).
12 mm thick plaster with cement & coarse sand mortar in 1:1:5 over brick work minimum thickness not to be less than 12 mm finished with 3 mm floting coating of neat cement including supply of all materials, labour T&P etc. required for proper completion of the work.
Scraping old color washing and preparing the surface by removing loos material etc. including all labour and T&P etc complete.
40 mm thick over base concrete consisting of cement, local sand and 40 mm gauge first class brick ballast in the proportion of 1:4:8. For construction of apron 0.6 m wide.
White washing in three coat including supply of all materials, labour, T&P etc. complete required for proper completion of the work
Providing plaster of Paris wall putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Apex Ultima /Acrylic Exterior/ interior paint of approved brand & manufacturer & of required shade on under coated wall surface to give an uniform surface over one primer coat of white cement of approved brand after thoroughly brushing and rubbing the surface free from mortar droppings & other foreign matters including prepairing even surface with plaster of paris including supply of all material labour T&P etc required for proper completion of work.
Supply and fixing of flush doors including supply of all materials, paints, labour T&P etc. required for proper completion of the work.
Repair for electric fitting
Repair for sanitation work
Site clearence and other unforseen items.
BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD (ZONE-II)
Provide all materials; labour T&P etc. for the Boundary wall as per direction of Engineer-in-charge.
Main compound
Long wall
Short wall
Deduction for Main Gate
Deduction for Wicket Gate
Total
Provide all materials, labour T&P etc. required for proper completion of work and construct pillars as per type design and fixing of gate 3.6 m wide gate and 1.2 m wicket gate.
Provide all materials, labour T&P etc. required for proper completion of work and construct Interlocking approach road.
Main road in compound
For OHT
For Staff Quarter
Total
Construction of Drain as per type design in all materials, labour T&P etc. required for proper completion of work inside campous for proper drainage. Size (300 mm x 300 mm).
Provision of Lighting in campous as per direction of Engineer-in-charge including all materials , labour T&P etc complete.
Provision of land ecapping and aboriculture in campous as per direction of Engineer-in- charge including all materials , labour T&P etc complete.
Excavation work in excavation by mechanical means (Hydraulic excavator)/manual means over are as (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- in-charge.
Provide all materials, labour T&P etc. required for proper completion of work including leveling, dressing excavation and filling of earth where necessary for develop of water works site including carriage of earth.
For Main Compound
BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD (ZONE-III).
Provide all materials; labour T&P etc. for the Boundary wall as per direction of Engineer-in-charge.
Main compound
Long wall
Short wall
Deduction for Main Gate
Deduction for Wicket Gate
Total
Provide all materials, labour T&P etc. required for proper completion of work and construct pillars as per type design and fixing of gate 3.6 m wide gate and 1.2 m wicket gate.
Provide all materials, labour T&P etc. required for proper completion of work and construct Interlocking approach road.
Main road in compound
For OHT
For WTP
For MCWR
For Staff Quarter
Total
Construction of Drain as per type design in all materials, labour T&P etc. required for proper completion of work inside campous for proper drainage. Size (300 mm x 300 mm).
Provision of Lighting in campous as per direction of Engineer-in-charge including all materials , labour T&P etc complete.
Provision of direction of Engineer-in-charge including all Engineer-in-charge including all materials , labour T&P etc complete.
Excavation work in excavation by mechanical means (Hydraulic excavator)/manual means over are as (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- in-charge.
Provide all materials, labour T&P etc. required for proper completion of work including leveling, dressing excavationb and filling of earth where necessary for develop of water works site including carriage of earth.
For Main Compound
SUB STATION BUILDING (LT/HT ROOM / GENERATOR ROOM)
Provide all materials, labour T&P etc. and construct the sub statoin building (LT/HT Room along with meter room) as per type design approved by Jal Nigam.
Raw Water Pumping Station Intake Well
Raw Water Pumping Station WTP
STAFF QUARTER FOR PUMP OPERATOR (ZONE-II)
Provide all materials, labour, T&P Complete and construction of a set of Single room Set Staff quarter for pump operator as per type design.
STAFF QUARTER FOR PUMP OPERATOR (ZONE-III)
Provide all materials, labour, T&P Complete and construction of a set of Single room Set Staff quarter for pump operator as per type design.
GROUND WATER RECHARGE WORK (ZONE-II)
Supply all materials, labour, tools and planta and provide arreangement for ground water recharge as per cost estimate attachment.
(i) At Water works
GROUND WATER RECHARGE WORK (ZONE-III)
Supply all materials, labour, tools and planta and provide arreangement for ground water recharge as per cost estimate attachment.
(i) At Water works
PUMPING PLANT AND ACCESSORIES FOR INTAKE WELL
Supply of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckring shall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm. 21 mtr/suitable length column assembly, with vertical hollow shaft.Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :-
3100 LPM / 80 Mtr. HEAD / 100 HP MOTOR (2w+1s) Head & discharge may increased as per site requirement
MAIN PIPING AND VALVES :- Supply of 200mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 250mm common Header upto 1 m. outside the pump house along with 250 x 200 x 250 mm A/F Tee (03 Nos) , 250 mm bend (01 Nos), 250 mm blind flange (01 Nos), D/F Pipes suitable size all necessary nuts, bolts, rubber packing, M.S Support for pipe, mechanical joints (04 Nos) and valve etc. complete in all respect Note -Suitable Size of Delivery line of each pumping plant and common header it may increase as per site conditions with best engineering manner
Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve with Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes
Valve actuator of size :- 200mm for pumps or more suitable size as per site condition with best engineering manner
Valve actuator of size :- 250mm for common header or more suitable size as per site condition with best engineering manner
Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-16 to be fixed after pumps for 90% fast closing & 10% slow closing .
200 mm Dia for pumps or more as per site condition with best engineering manner
250 mm Dia for common header or more as per site condition with best engineering manner
CE/UL Certified Electromagnetic flow meter :- Supply of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable.
Size 250mm for common header or more as per site condition with best engineering manner
ELECTRICAL ITEMS:-
Supply & laying of 1.1KV grade XLPE insulated armoured multi strand copper conductor cable of 3C x 35 sq.mm or more size suitable for pumping plant load from control Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I)
MOTOR CONTROL CENTER (MCC) PANEL :- Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION 630A, 50KA, TPN, ACB microprocessor baseed (O/C,S/C) release - 2 No with suitable rating auto phase reversal unit , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V - 1 No, Digital Ammeter 0-400A - 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION 200 A, 50KA, TPN, MCCB microprocessor based (O/C,S/C) RELEASE - 3 No, Spreader Links & Extended ROH for MCCB - 3 Nos., 63A TPN MCCB 35KA - 2 Nos. Terminal 63A
Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating suitable for capacity 100 HP / 75 KW pumping plant
Supply of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 91 KVAR or more suitable as per site requirement
CE/UL Certified level transmitter for Intake well :- Supply of CE/UL cirtified of Radar level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement. Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4" LED Range- 0 to …30... mtrs Accuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68
CE/UL Certified Pressure transmitter for pumps and common header :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel including mounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4" LED Accuracy - +/- 0.1 % of full scale or better Enclosure- IP 68
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 Supplying and laying 50 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) ( 01 job = seprate Double Earthing of each pumping plant and its pannel as per IER )
Installation ,testing at site & manufacturer works or as per direction of Engineer Incharge and of all E/M equipments, power wiring of Electrical equipments and commissioning of the pumping plants.
3Ton or More suitable as per site requirement capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder
Rubber mats for electrical purpose as per IS:5424-1969, plain/chequered (1mX2m) - 10mm thickness
Cable trench Chequerred plate
Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board.
Internal & External electrification of pumping station :-
Indoor Lighting
Surface Mounting
Providing & Fixing of IP-67 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard
Suspended Mounting / Surface Mounting
36W LED light fixture 2'×2' with acrylic / prismatic front cover.
Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc.) as required.
1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
Installation, testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.with regulator
Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required.
450mm sweep (900/1400 RPM)
Fixing of fresh air fan/exhaust fan up to size of 300/450 mm on ply/ poly board of 6.0 mm in existing window frame including cost of ply, cutting of hole in ply. Nut bolts etc. as required.
Outdoor Lighting
Supply and fixing of all in one solar LED light fixturewith integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system.
Compact Solar LED Street Light having protection of IP-67- 60W(MONO) 18V / 12.8V 27Ah /40W
Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc .All sockets should be connected to sufficient size earth wire and seprate earthing for each pumphouse
250 KVA or more as per site requirement SUB STATION AT INTAKE WELL
Supply of 50 Sq.mm size XLPE HT cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer.
Supplying of 250 KVA or more suitable as per site requirements , 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 7.5% to -7.5%,at each step of 2.5 % having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site.
Supply and laying of 650/1100 volt grade 240sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.T panel and from outgoing panel to distribution panel (1x3½x240 sq mm)
Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules.
Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable
Supply and making of outdoor cable end termination joint kit of size 240 sq mm 3 core for 11 KV H.T. XLPE cable
Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works.
NOC from Electrical safety department for all field installations such as pumping plants, substation etc.
PUMPING PLANT AND ACCESSORIES FOR MCWR TO ZONE-( I+II )
Supply of Vertical type self-water lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckring shall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm. 06 mtr/suitable length column assembly, with vertical hollow shaft . Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :-
2400 LPM / 54 Mtr. HEAD / 50 HP MOTOR (2w+1s) Head and discharge may increase and suitable as per site requirement
MAIN PIPING AND VALVES :- Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 200mm common Header upto 1 m. outside the pump house along with 200 x 150 x 200 mm A/F Tee (3 Nos), 200 mm bend (01 Nos), 200 mm blind flange (01 Nos), D/F Pipes suitable size all necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints (04 Nos) and valve etc. complete in all respect as per site conditions. Note - Suitable Size of Delivery line of each pumping plant and common header it may increase as per site conditions with best engineering manner
Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve with Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes
Actuator with Sluice Valve of size :- 150mm or more size suitable as per site condition for pumps
Actuator with Sluice Valve of size :- 200mm or more size suitable as per site condition for common header
Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing .
150 mm Dia or more size suitable as per site condition
200 mm Dia or more size suitable as per site condition
CE/UL Certified Electromagnetic flow meter :- Supply of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable.
Size 200mm or more size suitable as per site condition for common header with best engineering manner
ELECTRICAL ITEMS:-
Supply & laying of 1.1KV grade XLPE insulated armured multi strand copper conductor cable of 3C x 25 sq.mm OR more size suitable as per load of pumping plant from control Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I)
MOTOR CONTROL CENTER (MCC) PANEL :- Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION 400A, 50KA, TPN, MCCB microprocessor baseed (O/C,S/C) release - 02 No with suitable rating auto phase reversal uint , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V - 1 No, Digital Ammeter 0-400A - 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION 160 A, 50KA, TPN, MCCB microprocessor based (O/C,S/C) RELEASE - 6 No, Spreader Links & Extended ROH for MCCB - 6 Nos., 63A TPN MCCB 35KA - 2 Nos. Terminal 63A
Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating capacity 45 KW for operating 50 hp motor
Supply of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 50 KVAR
CE/UL Certified level transmitter for CWR :- Supply of CE/UL cirtified of Radar level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement. Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4" LED Range- 0 to …30... mtrs Accuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68
CE/UL Certified Pressure transmitter for pumps and common header :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel including mounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4" LED Accuracy - +/- 0.1 % of full scale or better Enclosure- IP 68
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 Supplying and laying 50 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required Having resistance of Maximum 1 ohm. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) (01 job = seprate Double Earthing of each pumping plant and its pannel as per IER )
Installation ,testing at site & manufacturer works of all e/m euipments or as per direction of engineer incharge , power wiring of Electrical equipments and commissioning of the pumping plants.
3Ton capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder
Rubber mats for electrical purpose as per IS:5424-1969, plain/chequered (1mX2m) - 10mm thickness
Cable trench Chequerred plate
Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board.
Internal & External electrification of pumping station :-
Indoor Lighting
Surface Mounting
Providing & Fixing of IP67 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard
Suspended Mounting / Surface Mounting
36W LED light fixture 2'×2' with acrylic / prismatic front cover.
Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc.) as required.
1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
Installation, testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.with regulator
Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required.
450mm sweep (900/1400 RPM)
Fixing of fresh air fan/exhaust fan up to size of 300/450 mm on ply/ poly board of 6.0 mm in existing window frame including cost of ply, cutting of hole in ply. Nut bolts etc. as required.
Outdoor Lighting
Supply and fixing of all in one solar LED light fixturewith integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. ( For MCWR )
Compact Solar LED Street Light- 60W(MONO) 18V / 12.8V 27Ah /40W
Supply installation tesling & Commissioning of IS0 certifted company made high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal (Octogonal) section, telescopic jointed and welding as per BS 5135 and also provide test certificate for wind tunnel test for High mast fixtures. complete in all respect. (for WTP)
12.5 Mtr. HM (in 2 Section)
Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 Im/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz‡3%, Power Factor >0.95 ,driver Efficiency >85% . THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K + 1355K, Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture -shall be IS 10322 Complianced and also provide test Certificate/ report with liable warranty of product/accessories.
High Power LED Flood Light 200W
Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc.
250 KVA or more as per requirements SUB STATION AT ( MCWR+WTP )
Supply of 50 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer.
Supplying of 250 KVA or more rating suitable for site requirement, 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, outdoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of 2.5 % with range+ 7.5% to -7.5%, having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site.
Supply and laying of 650/1100 volt grade 240sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.T panel and from outgoing panel to distribution panel (1x3½x240 sq mm)
Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules.
Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable
Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works.
NOC from Electrical safety department for all field installations such as pumping plants, substation etc.
PUMPING PLANT AND ACCESSORIES FOR ZONE-3 OF MCWR
Supply of Vertical type self-water lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckring shall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm. 06 mtr/suitable length column assembly, with vertical hollow shaft. Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :-
900 LPM / 36 Mtr. HEAD / 15 HP MOTOR (1w+1s) Head & discharge may increase as per site requirement
MAIN PIPING AND VALVES :- Supply of 100mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outside the pump house along with 100 x 100 x 100 mm A/F Tee (2Nos), 100 mm bend (01 Nos), 100 mm blind flange (01 Nos), D/F Pipes suitable size all necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints (03 Nos) and valve etc. complete in all respect as per site conditions. Note - Suitable Size of Delivery line of each pumping plant and common header it may increase as per site conditions with best engineering manner
Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve with Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve having body door cover of graded in cast iron to IS:210 Gr.Fg.260 body and door rings of SS ASTM A743 Gr.CF8 and bearing block of leaded tin bronze to IS:318 Gr.LTB2 hinge pin of stainless steel AISI:431.Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI. Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes
Actuator with Sluice Valve of size :- 100mm or more size suitable for pumps
Actuator with Sluice Valve of size :- 100mm or more size suitable for common header
Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing .
100 mm Dia or more size suitable for pumps and common header
CE/UL Certified Electromagnetic flow meter :- Supply of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable.
Size 100mm or more size suitable for common header
ELECTRICAL ITEMS:-
Supply & laying of 1.1KV grade XLPE insulated armoud multi strand copper conductor cable of 3C x 6 sq.mm from control Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I)
MOTOR CONTROL CENTER (MCC) PANEL :- Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION 100A, 50KA, TPN, MCCB microprocessor baseed (O/C,S/C) release - 2 No with suitable rating auto phase reversal unit , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V - 1 No, Digital Ammeter 0-400A - 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION 63A, 50KA, TPN, MCCB microprocessor based (O/C,S/C) RELEASE - 3 No(1w+1s+1 Spare), Spreader Links & Extended ROH for MCCB - 3 Nos., 63A TPN MCCB 35KA - 2 Nos. Terminal 63A
Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating capacity 15 KW for 15 hp motor
Supply of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 13 KVAR or more as per requirements
CE/UL Certified Pressure transmitter for pumps and common header :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel including mounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4" LED Accuracy - +/- 0.1 % of full scale or better Enclosure- IP 68
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 Supplying and laying 50 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) ( 01 job = seprate Double Earthing of each pumping plant and its pannel as per IER )
Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants.
Rubber mats for electrical purpose as per IS:5424-1969, plain/chequered (1mX2m) - 10mm thickness
Cable trench Chequerred plate
Automation For Intake Well
CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification.
GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification.
CE/UL Certified Intelligent energy meters
CE/UL Certified three phase Surge protector for control panel at main switch
CE/UL Certified 7" touch screen suitable for communication with PLC/RTU for local display & control of process parameters.
Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments
Cable
(i) Complete cabling upto 3 Pumps
Security Survelliance IP Camera with recorder (optional)
Installation, commissioning & testing
Local Control Station at WTP
CE/UL & BIS Certified industrial grade LED Monitor with latest configuration as per specification
Desktop / PC with i5/i7 processor for as per technical bid documents
CE/UL Certified 5 KVA UPS with batteries as per technical bid documents
Full development version of required TAGS SCADA Software with customization of software for LCS as per requirement as per spec. mentioned in technical bid documents.
CE/UL certified local control room PLC with redundant CPU & power supply at LCS in IP 54 enclouser as per spec. mentioned in technical bid documents.
GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & received data & gather from remote sites to control station, all accessories included signal enhancer anternna along with running expenses till DLP
CE/UL Certified firewall for network protection
SURGE PROTECTOR FOR ETHERNET communication protection.
CE/UL certified industrial grade Ethernet Swtich
Cannon/HP or equivalent Laser printer 1018 or equivalent
Security Survillance IP Camera with recorder (Optional)
Installation, Commissioning & testing including required furniture, A/C etc.
AUTOMATION FOR MCWR
CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification.
GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification.
CE/UL Certified Intelligent energy meters
CE/UL Certified three phase Surge protector for control panel at main switch
CE/UL Certified 7" touch screen suitable for communication with PLC/RTU for local display & control of process parameters.
Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments
Turbidity Analyzer at MCWR
PH Analyzer
Chlorine Analyzer
Cable
(i) Complete cabling upto 3 Pumps
Security Survelliance IP Camera with recorder (optional)
Installation, commissioning & testing
ESTIMATE FOR AUTOMATION OF EXISTING STORAGE / HILLOCK /CWR ( 450 KL+350KL=800 KL ) AGAINST ZONE-1
ESTIMATE FOR AUTOMATION OF EXISTING STORAGE / HILLOCK /CWR ( 450 KL+350KL=800 KL ) AGAINST ZONE-1
CE/UL Certified level transmitter for CWR / HILLOCK :- Supply of Radar type level transmitter with battery power CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement. Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4" LED Range- 0 to …30... mtrs Accuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68
CE/UL Certified Electromagn
BASIC RATE In Figures To be entered by the Bidder Rs. P
TOTAL AMOUNT Without Taxes in Rs. P
CE/UL Certified 5 KVA UPS with batteries as per technical bid documents
Supply of all materials, labour and T&P etc. complete for the construction of Ground RCC MCWR of 700 KL capacity & with 1.00m wide P.C.C. appron alround with 6 cm semi circular P.C.C. drain M.S. ladder with hand rails out side and inside the tank body proper ventilators at top, water level indicator, Lightening conductor as per latest I.S.I. or electricity rules, 1150mm dia medium pattern C.I. Manhole cover hinged with locking arrangement fixing and jointing vertical DID/F, pipes, specials and duck foot bends of required size for inlet, outlet fising of outlet sluice valve and wash out sluice valves with all jointing materials for proper completion and other appurtenant works including excavation in all type of soil & in rock etc. painting on exposed water proof cement paint, painting of pipes and ladder with approved anticorrosive paints also including testing of the CWR including carriage of construction materials by truck/ head load etc. upto site of work & also.. Supply of following size of DI D/F (K-7) (K-9) pipes conforming to IS8329/2000 or its latest amendment upto rail head including all taxes, duties insurance charges etc. Inlet pipe 350 mm dia Outlet pipe 350 mm dia Over flow pipe 350 mm dia Wash out pipe 100 mm dia Carting of above size of DI K-7 and K-9 pipes upto site of work and lowering them into the trenches and laying true alignment and gradientand jointing of pipes complete (including testing of pipe lines and cutting of pipes for making up the length excluding the cost of trenches). Inlet pipe 350 mm dia Outlet pipe 350 mm dia Over flow pipe 350 mm dia Wash out pipe 100 mm dia Supply of following dia ISI Mark sluice valve conforming to IS 780/1984 or its latest amendment of standard make (Kirloskar or IVC Make) including all taxes etc. and carting, loading and unloading upto departmental store. 100 mm dia (in wash out pipe) Carting of following fittings/ sepicels to the site of work, lowering them into trenches, fising in position and jointing them with pipe lines and testing etc. complete (including supply of all jointing materials). Sluice valves/ gate valves of 10 kg/cm2 working pressure 100 mm dia (in wash out pipe)Supply of all materials, labour T&P etc all complete to construct sluice valve chamber of following sizes. Sluice valve chambers for 300 mm dia Sluice valve at outlet pipe. Provide all materials, labours, T&P and construction over flow chambers as per departmental drawing or as directed by the Engineer.Same as above but for wash out chambers. Provision for the disposal of over flow water & wash out water from chambers to nearest suitable point of disposal including supply of pipes, its laying jointing excavation and protection work at the point of disposal.
Supply of fixing, jointing of following size of D.I. D/F pipes with D.I. D/F specials conforming to IS 329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest/ relevant I.S. specifications with all jointing materials for proper completion of work including other appurtenant work and excavation in all types of soil. Inlet pipe 250 mm Outlet pipe 350 mm Overflow pipe 250 mm Washout pipe 100 mm Supply and fixing of following sizes C.I. D/F sluice valves with Gear opreated as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete. Inlet pipe 250 mm Outlet pipe 350 mm (Gear Operated) Washout pipe 100 mm Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should support on the raft not on the soil. Construction of Masonary type sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement. Construction of washout/overflow chamber as per departmental type design and drawing. Construction of P.C.C. floor & drain and all other necessary work as per departmental type drawing and design. Weather Coat painting of all concrete surface and enamal painting of steel pipe works with three coats of approved cement paint and anticorrosive paints. Testing & Commission etc. all complete work.
Supply of fixing, jointing of following size of D.I. D/F pipes with D.I. D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest/ relevant I.S. specifications with all jointing materials for proper completion of work including other appurtenant work and excavation in all types of soil. Inlet pipe 150 mm Outlet pipe 350 mm Overflow pipe 150 mm Washout pipe 100 mm Supply and fixing of following sizes C.I. D/F sluice valves with Gear opreated as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete. Inlet pipe 150 mm Outlet pipe 350 mm (Gear Operated) Washout pipe 100 mm Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should support on the raft not on the soil. Construction of Masonary type sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement. Construction of washout/overflow chamber as per departmental type design and drawing. Construction of P.C.C. floor & drain and all other necessary work as per departmental type drawing and design. Weather Coat painting of all concrete surface and enamal painting of steel pipe works with three coats of approved cement paint and anticorrosive paints. Testing & Commission etc. all complete work.
CE/UL Certified Electromagnetic flow meter :- Supply of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable.
400 mm dia
Survey, Investigation, Soil Testing, Planning, Design and Drawing, construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevent latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractor's cost. For construction of Intake Well (for Goahand Np & Sarila Np) of minimum internal size of 10.00 M Dia & required Height with required length & 3.5 M width foot bridge , water inlet opening having minimum intake capacity to meetout the raw water required for WTP by different inlet points, construction of stair case, Pump house, Balcony, stair case post column beams etc. Such that to fix required nos. of VT Pump mention in item number 279, Power Control Panels, starters, intrumentation and SCADA & wireless telemetry (Voice & Data), internal and external electrification with adequate LED lightings including Excavation in soil i.e. Kankar mixed morrom/soft/hard rock and lean concrete of minimum grade of M-15 and R.C.C. in grade M-30 or above, in raft/ pile foundation, Intake R.C.C wall with supply of all type of steel bars of approved quality and cement OPC 53/43 grade of any make approved by the Employer as per design and drawings and binding the same including binding materials, diversion arrangement of flow during construction by making bundh across the dam supply gunny bags, sand, their filling suitable size of steel garder, with chain puli arrangement, dismantling and refixing etc. and also supply and fixing of collapsible gate, collapsible door, almunium window as per relevent specifications also including of three coat white washing, internal two coat snowcem painting, external painting with appex ultima or equivalent paint, all steel work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification of intake well, supply and fixing of three-row of 20 mm dia G (Midium) pipe railing with 65X65X6 mm M.S. Angle iron posts. Supply and fixing of aniet opening of required capacity as per requirements including of supply of all materials, labour, T&P etc. required for proper completion of works as per direction of the Engineer. Cost of VT Pumps, panels, SCADA panel board, pipe manifolds etc. are not covered in this item.
PUMP HOUSE : Supply of all materials labour T&P etc. for the complete construction of RCC Framed pump house adjacent to CWR as per approved design, drawing and standard specifications with 1 n wide PCC appron around along with 15cm semicircular PCC drains, RCC wall upto plinth level, to roof of pump house, laying case PCC 1:4:8, RCC floor, foundation and roof, 2m wide RCC plateform at plinth level, two column stair case from plateform to floor of pump house railing on the stair case and plateform foundation block of pumping plant RCC columns with bracket and longitudinal RCC beams to support moving gantry crane, plastering in the inner and outer brick masonary wall, flooring supply and fixing of doors, windows ventilators, painting on explosed surface with three coats of approved water proof cement paint, white washing in the inner surface, painting of door, windows ventilators, etc. supply and fixing of CI down pipes from roof to GL and other appurtenants works required to complete the pump house in all respect.
Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, including cost of soil testing and based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911. 1000 KL with 22 m Staging All components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456 Minimum depth of foundation below original ground level will be 2.0 Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure. The assumed bearing capacity of soil has been taken as 8 M.T. sqm 1 m wide two column RCC stair case from ground level to balcony. M.S. ladder made of 50 x 50 x 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to be top dome resting on an RCC plateform (75 x 75 cm and 10 cm thick) projecting from top ring beam and one alluminimum ladder inside thw tank body (from manhole in top dome to bootom dome). 1 m wide RCC balcony around the tank at the junction point of vertical wall and conical wall. Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, around the balcony at each landing from landing with top ring beam up to manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 x 50 x 6 mm M.S. angle section, spaced at intervals not more than 1.5 m. Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expended mantled jail. Lightening conductor as per I.S.S. 2309 of its latest electricity rules. It should consist proper elevation rod with 5test electricity rules. It should consist proper elevation rod with 5 of more fork points proper down conductors of prescribed mentale fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.roper size prescribed by ISS 2309-1969 and ISS 3013-1966. C.I. manhole of min 60 x 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3 mm thickness hinged with locking arrangement. This manhole should be fixed at top dome at proper place. (to be Continued on s.No. 173)
Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, including cost of soil testing and based on IS-3370 or liquid storage concrete in over head tank and oundation concrete as per specification in I.S. 2911. 350 KL with 24 m Staging All components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456 Minimum depth of foundation below original ground level will be 2.0 SMei. smic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure. The assumed bearing capacity of soil has been taken as 8 M.T. sqm 1 m wide two column RCC stair case from ground level to balcony. M.S. ladder made of 50 x 50 x 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to be top dome resting on an RCC plateform (75 x 75 cm and 10 cm thick) projecting from top ring beam and one alluminimum ladder inside thw tank body (from manhole in top dome to bootom dome). 1 m wide RCC balcony around the tank at the junction point of vertical wall and conical wall. Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, around the balcony at each landing from landing with top ring beam up to manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 x 50 x 6 mm M.S. angle section, spaced at intervals not more than 1.5 m. Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expended mantled jail. Lightening conductor as per I.S.S. 2309 of its latest electricity rules. It should consist proper elevation rod with 5test electricity rules. It should consist proper elevation rod with 5 of more fork points proper down conductors of prescribed mentale fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.roper size prescribed by ISS 2309-1969 and ISS 3013-1966. C.I. manhole of min 60 x 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3 mm thickness hinged with locking arrangement. This manhole should be fixed at top dome at proper place. (to be Continued on s.No. 177)
Supply of fixing, jointing of following size of D.I. D/F pipes with D.I. D/F specials conforming to IS 329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest/ relevant I.S. specifications with all jointing materials for proper completion of work including other appurtenant work and excavation in all types of soil. Inlet pipe 250 mm Outlet pipe 350 mm Overflow pipe 250 mm Washout pipe 100 mm Supply and fixing of following sizes C.I. D/F sluice valves with Gear opreated as per I.S.S. 700/1969 or its latest pressure 10 kg/sqcm including cartage from its store to the site of work, lowering them into trenches, fixing in position & testing etc. complete. Inlet pipe 250 mm Outlet pipe 350 mm (Gear Operated) Washout pipe 100 mm Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should support on the raft not on the soil. Construction of Masonary type sluice valve chamber for above sluice valve (3 No.) as per departmental type design and drawing including supply and fixing of 150 mm x 150 mm size C.I. surface box including locking arrangement. Construction of washout/overflow chamber as per departmental type design and drawing. Construction of P.C.C. floor & drain and all other necessary work as per departmental type drawing and design. Weather Coat painting of all concrete surface and enamal painting of steel pipe works with three coats of approved cement paint and anticorrosive paints. Testing & Commission etc. all complete work.
BASIC RATE In Figures To be entered by the Bidder Rs. P
CE/UL Certified Electromagnetic flow meter :- Supply of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp:- 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V. velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable.
BASIC RATE In Figures To be entered by the Bidder Rs. P
Survey, Investigation, Soil Testing, Planning, Design and Drawing, construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevent latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractor's cost. For construction of Intake Well (for Goahand Np & Sarila Np) of minimum internal size of 10.00 M Dia & required Height with required length & 3.5 M width foot bridge , water inlet opening having minimum intake capacity to meetout the raw water required for WTP by different inlet points, construction of stair case, Pump house, Balcony, stair case post column beams etc. Such that to fix required nos. of VT Pump mention in item number 279, Power Control Panels, starters, intrumentation and SCADA & wireless telemetry (Voice & Data), internal and external electrification with adequate LED lightings including Excavation in soil i.e. Kankar mixed morrom/soft/hard rock and lean concrete of minimum grade of M-15 and R.C.C. in grade M-30 or above, in raft/ pile foundation, Intake R.C.C wall with supply of all type of steel bars of approved quality and cement OPC 53/43 grade of any make approved by the Employer as per design and drawings and binding the same including binding materials, diversion arrangement of flow during construction by making bundh across the dam supply gunny bags, sand, their filling suitable size of steel garder, with chain puli arrangement, dismantling and refixing etc. and also supply and fixing of collapsible gate, collapsible door, almunium window as per relevent specifications also including of three coat white washing, internal two coat snowcem painting, external painting with appex ultima or equivalent paint, all steel work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification of intake well, supply and fixing of three-row of 20 mm dia G (Midium) pipe railing with 65X65X6 mm M.S. Angle iron posts. Supply and fixing of aniet opening of required capacity as per requirements including of supply of all materials, labour, T&P etc. required for proper completion of works as per direction of the Engineer. Cost of VT Pumps, panels, SCADA panel board, pipe manifolds etc. are not covered in this item.
PUMP HOUSE : Supply of all materials labour T&P etc. for the complete construction of RCC Framed pump house adjacent to CWR as per approved design, drawing and standard specifications with 1 n wide PCC appron around along with 15cm semicircular PCC drains, RCC wall upto plinth level, to roof of pump house, laying case PCC 1:4:8, RCC floor, foundation and roof, 2m wide RCC plateform at plinth level, two column stair case from plateform to floor of pump house railing on the stair case and plateform foundation block of pumping plant RCC columns with bracket and longitudinal RCC beams to support moving gantry crane, plastering in the inner and outer brick masonary wall, flooring supply and fixing of doors, windows ventilators, painting on explosed surface with three coats of approved water proof cement paint, white washing in the inner surface, painting of door, windows ventilators, etc. supply and fixing of CI down pipes from roof to GL and other appurtenants works required to complete the pump house in all respect.
CE/UL Certified 5 KVA UPS with batteries as per technical bid documents
Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, including cost of soil testing and based on IS-3370 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911. 1000 KL with 22 m Staging All components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S. 456 Minimum depth of foundation below original ground level will be 2.0 Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure. The assumed bearing capacity of soil has been taken as 8 M.T. sqm 1 m wide two column RCC stair case from ground level to balcony. M.S. ladder made of 50 x 50 x 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to be top dome resting on an RCC plateform (75 x 75 cm and 10 cm thick) projecting from top ring beam and one alluminimum ladder inside thw tank body (from manhole in top dome to bootom dome). 1 m wide RCC balcony around the tank at the junction point of vertical wall and conical wall. Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, around the balcony at each landing from landing with top ring beam up to manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. posts of 100 mm dia or on the posts made of 50 x 50 x 6 mm M.S. angle section, spaced at intervals not more than 1.5 m. Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expended mantled jail. Lightening conductor as per I.S.S. 2309 of its latest electricity rules. It should consist proper elevation rod with 5test electricity rules. It should consist proper elevation rod with 5 of more fork points proper down conductors of prescribed mentale fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.roper size prescribed by ISS 2309-1969 and ISS 3013-1966. C.I. manhole of min 60 x 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3 mm thickness hinged with locking arrangement. This manhole should be fixed at top dome at proper place. (to be Continued on s.No. 173)
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.50 MB
NewKulpaharTD.pdf
Tender Documents • 14.75 MB
BOQ_2089315.xls
BOQ • 0.90 MB
Download all tender documents and submit your bid