Executive Engineer, JPDCL,ED Kathua
office of the Executive Engineer, JPDCL,ED Kathua
Creation of 250 KVA Sub Station alongwith HT line for Oxygen Plant (Under PM Cares Fund) at GMC Kathua on Turnkey basis in respect of OM Division, Kathua(JPDCL)
2021_PDD_130113_1
KED/11 of 2021-22 Dt.08.07.2021
Open Tender
Electrical Works
Turn-key
10 days
Kathua
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Executive Engineer, JPDCL,ED Kathua
Exempted
4 Aug 2021
9 Jul 2021
19 Jul 2021
9 Jul 2021
17 Jul 2021
9 Jul 2021
9 Jul 2021 - 13 Jul 2021
Amount
Creation of 250KVA Sub Station on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11/0.433kV, 250 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Copper wound ), and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
400 sqmm 1 Core Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type(For Incomer)
9 Mtr. Long PCC Pole( WL-300Kg)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. ( 4 Nos for Transformer and 1No. for Panel)
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Fabrication, Supplying, installation, Testing and commissioning of panel made out of 2mm thick M.S Sheet (1010(H) X 1000(W) X 325(D) MM), with 2 no front doors, 2 no earting bolts, floor mounted, Provision for gland plates with suitable size holes and glands at the bottom for 4 no incoming and 4 no outgoing calbles 300mm2,vermin and dust proof, outdoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly powder coated with Light Admiral Grey Paint (Shade 697 of IS 5) with provisions for fixing of 1No.incomer FP MCCB(300A) , ) Aluminium Bus Bar and other allied accessories etc as required. (Al Bus bars of suitable size connected to MCCB from one end and placed suiable for connecting outgoing cables)
Providing and fixing of 400A, 50KA, FP, MCCBwith thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubic panel, making connections etc as required and other accessories (L&T, C&C, HAVELLS or SCHNEIDER Make)
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards 0.5 cum /pole
11KV CT/PT Units of 15/5A ratio including 3-Phase, 4-wire Trivector Meter with compatible Meter Box and PVC Copper Control cables of appropiate size and length
Erection of Chain Link Mesh fencing of dimension 8'X8'X4' with angle supports and door(complete Job)
Sundry items like aluminium lugs, Jumpers, binding Tape etc
Laying of HT Line on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9 Mtr. Long Pole(PCC WL-300Kg )
50 mm² AB(HT) cable (3 X 50 + 1 X 70) XLPE (11KV, 3C +Earth) (Havells/Polycab Make)(Three Ckts. Of length 200 Mtrs each) Note :- One ckt from tapping point to existing 630KVa DT. And two ckts from existing 630KVA to new 250KVA DT.
Heat shrinable outdoor cable termination kits)
Suspension/Tension clamp with eye hooks
Galvanised nuts and bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
HI-TECH TRANSFORMERS
EMINENT ENGINEERING SEVICES
M/S LUMEN ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .