Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹30.4 L+₹1.3 L (4.51%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance highest bid quoted | |
| 3 | L3₹30.9 L+₹1.9 L (6.50%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L3 | Rejected-Finance highest bid quoted |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
8 Nov 2021, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
COMPREHENSIVE MAINT OF CENTRALISED AC PLANTS THREE INTO FIFTY FIVE TON AND THREE INTO TWENTY FIVE TON THREE PHASE ONLINE UPS FIRE DETECTION ALARM SYSTEM AND PERIODICAL MAINT AND SERVICING OF REFRIGERATOR ACS WATER COOLER SOLAR WATER HEATER ELECTRIC G
2021_MES_477651_1
CA NO GE/GUR-/NIT-51/2021-22
Open Tender
Miscellaneous Works
Piece-work
270 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹84,000
2 Dec 2021
24 Sept 2021
10 Nov 2021
24 Sept 2021
8 Nov 2021
8 Oct 2021
Amount
M&L for servicing of Split type AC capacity 1.5 ton / 2.0 ton , cleaning of Indoor / outdoor unit, cooling /condensing coil , reinsulation of refrigerant tubing , replacement of worn out spare parts of AC & checking wiring and renewing side and straight thimble, material for soldering (LPG Gas breezing rod, breezing power), drain out pipe of required length as per site, fastner, nut bolts etc for complete all as specified and as directed. Note: Quoted rate deem to included brass nut and brass end caps, brass nuts, brass coupler nuts and brass gas refilling valve of any size and type. Worn out spare parts will be measured and paid separately under respective items of the Schedule.
M&L for detecting the cause of leakage by nitogen gas flash method or soap method in any type/capacity1.5 ton/2 Ton of AC in position and ensuring the complete system leak proof, by solderinng and brazing and charging full or top up with refrigerant gas (R-22 & R-410a) with appropriate quantity as per site including testing for smooth functioning complete all as specified and as directed. Note: (i) Refilling and toping up of refrigenrant (R-22 & R-410a) as required on site is deemed to be included in quoted rate. (ii) T&P, Nitogen (any qty) required site to work on height and soldering & brazing is deemed to be included in quoted rate. (iii) Demounting of units (indoor and outdoor) from their position or from height and refixing back at height is deemed to be included quoted rate. Contractor has to arrange for its own labour & T&P for demounting & refixing. No extra payment will be done for demounting & refixing.
Supply, installation, commissioning and testing of compressor unit Hermetical/rotary type as per site of capacity 19000 BTU/Hr split type air conditioner cap 1.5 ton all as directed. Hitachi/LG Note: (i) Dismantling of unserviceable compressor and re-installation of serviceable compressor is deemed to be included in the unit quoted rate. (ii) Refilling and toping up of refrigenrant (R-22 & R-410a) as required on site is deemed to be included in quoted rate. (iii) T&P required to work on height and soldering & brazing is deemed to be included in quoted rate.
Same as Item No 3 above but capacity 2 ton. Make: Emerson / Kirloskar/Tecumech
M&L for rewinding of the blower motor 1/6,1/5,&1/8 HP of AC any type /capacity with same gauge super enamelled copper wire complete including taking out old unserviceable winding kit complete all as specified and as directed.
M&L for rewinding of the outdoor fan any type /capacity ((upto 1/13 HP, 800 rpm, 57 watt) thermally protected with same gauge super enamelled copper wire complete including taking out old unserviceable winding kit complete all as specified and as directed.
Supply and fixing in replacement of outdoor fan Blade for AC upto 2 ton as per site, complete as directed. Note: Sample shall be checked at site before procurement to match the existing models.
Supply and fixing in replacement of starting relay of existing makes and capacity duly ISI marked for AC W/T and split type 1.5/2 Ton capacity as per site requirement, complete all as specified and as directed.
Supply and fixing in replacement of starting capacitor of existing make and capacity (40/60 & 80/100mfd) duly ISI marked for window type A/C 1.5 ton and split type AC 2 ton complete all as specified and as directed.
Supply and fixing in replacement of three state running capacitor of existing make and capacity (50/6, 45/5 & 36/6mfd) duly ISI marked for window type A/C 1.5 ton and split type AC 2 ton complete all as specified and as directed.
Supply and fixing in replacement of refrigerant tubing for suction /discharge of (5/8, 1/4, & 1/2 )including insulation tubing all as per site requirement and as directed by Engr-in-Charge.
Supply and fixing in replacement of of capacitor 10 Mfd blower motor ISI marked complete all as specified and as directed.
S&F in replacement of PCB card, board type/box type (2 PCB cards fabricated in one box) suitable for existing split type AC 1.5/2 Tone AC of any make/model complete all as specified and as directed.
Supply and fixing in replacement of allen key type hand shut valve suction for split AC 1.5/2 Toncomplete all as specified and as directed.
Ditto item No 14 but allen key type hand shut valve discharge for split Ac 1.5/2.0 ton complete all as directed
S&F in replacement of cooling coil of indoor split type AC 1.5/2.0 Ton capacity complete all as per existing make and model
Supply and fixing in replacement of Split AC Remote (for any make AC) as per model on site. Note: Sample shall be checked at site before procurement to match the existing models.
M&L and T&P (any type) for shifting of Split AC of any capacity both indoor, outdoor & its connected accessories (like drain out pipe, copper tubing, frame etc.) by properly demounting from one location and re-fixing it in other location as per user requirement including cutting hole and removing old copper pipes and using same for the new location and testing/commisioning after making proper connections by deploying sufficient labour and tool, complete all as specified and directed by EIC. Note:- (i) Any type of civil work involve in shifting is deemed to included in quoted rate. (ii) Shifting can be on same floor or to higher floors or any other location, no extra payment will be made for labour and transportation. (iii) Cost of refrigerant gas charging of unit (full or top up) is deemed to be included in quoted rate. (iv) Any extra item required at site due to difference in location will be measured in relevant item.
Taking down old u/s indoor unit along with connected accessories and Supply, intallation, testing and commissionging of new indoor unit of split type AC of capacity 1.5Ton including all connections. Note: Base frame of indoor unit, remote as per new unit PCB card, gas refilling if leaked during installation, intallation charges and other connected work is deemed to be inclucive of rates.
Same as Item No: 19 above but capacity 2 ton.
Supply and fixing in replacement of Industrial socket sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug and socket with one single pole MCB of 20 Amp complete.
M&L for servicing/detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 80/40 ltr, 120/40 Ltr, & 150/150 Ltrs complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) Refilling and toping up of refrigerant (type and quantity) as required on site is deemed to be included in quoted rate.
Supply and fixing in replacement of compressor reciprocating type (hermetically) sealed suitable for capacity 80/40, 120/40, 150/150 litre water cooler complete all as specified and as directed. Make: Emerson/Hitachi/LG
Supply and fixing in replacement of thermostat switch suitable for existing water cooler any make and capacity complete all as specified and as directed. Make: Renutrol/Indofos/Annapurna/Totaline
Supply and fixing starting relay and overload relay suitable for existing size and make water cooler complete all as specified and as directed. Make: Epcos/Asian
Supply and fixing in replacement of starting capacitor for water cooler suitable for existing size & make water cooler complete all as specified and as directed.
Supply and fixing running capacitor suitable for existing size & make water cooler complete all as specified and as directed.
Supply and fixing drier/filter of suitable capacity, complete all as specified and directed.
Dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge or gauge as approved by Engineer-in-Charge including replacement of shaft/ bush etccomplete all as specified and as directed.
S&F in replacement of of fan blade of condenser motor of any make and capacity of water cooler complete all as specified and as directed.
M&L for servicing of deep freezer any capacity and size including cleaning greasing including detecting the cause of leakage by nitrogen flash method in any type/capacity and ensuring the complete system leak proof and charging full or top up with refrigerant gas with appropriate quantity as per site including testing for smooth functioning complete all as specified and as directed. Note : (i) Refilling and toping up of refrigenrant (any type and any quantity) as required on site is deemed to be included in quoted rate. (ii) Fixing of Anti freeze, drier/filter, brass nut, bolts, thimble, wiring, valves etc are deemed to be included in quoted rate.
Supply and fix in replacement of starting relay of deep freezer of any size & make complete all as specified and as directed.
Supply and fix in replacement/ thermostat switch for deep freezer any make & capacity complete all as specified and as directed.
Repair and maintenance of refrigerator of any capacity capacity including replacement of following unserviceable parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, Door opening handle - 01 Set, freezer chamber - 01 No, Door panel complete - 01 set, thermostate switch - 01 No, vegetable tray-01 No, Door rubber beeding set - 01 Set, ice tray - 02 Nos. Testing and commissioning of refrigerator after repair in its original locating all as specified and directed.
Supply and labour for charging of Refrigerant gas R-22 in cooling appliances of any type and capacity, complete all as specified and directed. Note: Labour cost for charging is deemed to be included in quoted rate. Since R-22 is flammable & exposive gas, contractor has to make sure for the safety and take adequate safety measure for technicians/ labour during charging gas. Deptt will not be responsible for any accident nor liable to pay any compensation to victim or contractor.
Supply and labour for charging of Refrigerant gas R- 410a in cooling appliances of any type and capacity, complete all as specified and directed. Note: Labour cost for charging is deemed to be included in quoted rate. Since R-410a is high pressure & exposive gas, contractor has to make sure for the safety and take adequate safety measure and suitable tools for technicians/ labour during/for charging gas. Deptt will not be responsible for any accident nor liable to pay any compensation to victim or contractor.
M&L for visiting of Technician on site and checking, inspecting & detecting fault in AC's, Deep Freezers, Water coolers & refrigerators of any capacity, type, any make & model by technicians and rectifying minor defects on site and noting down material required to make cooling appliance functional in next visit. Note: (i) Spare required will be measured saperately. (ii) Servicing visit will not be measured under this item.
M&L for servicing of room desert cooler of any make size by cleaning, oiling & greasing, checking of defects and rectifying unserviceable switches, control switch etc adjusting and setting for work including complete electric wiring with 3 core flexible cable plug top and testing complete all as specified and as dirceted by Engr-in-Charge.
M&L for rewinding of fan motor of desert cooler with super enamelled copper wire of existing gauge or gauge as approved by Engineer-in-Charge complete all as specified and as directed. Note: replacement of bush bearing is deemed to be included in quoted rate.
M&L for replacement of tullu pump submersible type for desert cooler having, 2mtrs head, 500l/h discharge rate, 25 watts, single phase, complete all as specified and as directed.
Supply and fix in replacement of New fan motor of 100watts, copper winding, Class E insulation, 1500 rpm, steel shaft, including capacitor of 4 mfd for desert coolers complete all as specified and as directed.
Supply and fixing in replacement of capacitor 4 Mfd blower motor & desert cooler motor ISI marked complete all as specified and as directed.
M&L for plastic distributor 3 way of superior quality as per site requirement complete all as specified and as directed.
M&L for PVC pipe 15 mm dia for desert cooler for inside connection of superior quality complete all as specified and as directed.
S&F desert cooler grasspad suitable for cooler of capacity 4000 cum/hrs & dimension of pad not less than complete all as sepcified and directed.
M&L for painting of cabinet body of room cooler with one coat of red oxide paint and two coats for desert cooler water tank with black enameled paint and outer body with smoke grey paint after preparation of surface complete all as specified and as directed.
Taking down ceiling fan (C/F of any size/make), cleaning its dust properly oiling and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge. Note :- (i) The spares like cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the ceiling fans functional. No extra payments will be done on this account.
Taking down exhaust fan & wall mounting and re-connecting up including provision of cable from ceiling rose to exhaust fan after cleaning all dust complete all as specified and as directed. Note :- (i) The spares like nuts & bolts etc if found defective/damage deemed to be replaced and make the fans functional. The rates quoted for the same deemed to be included for the above job.
M&L for Rewinding the stator complete with super enamelled bare copper conductor with the same size and number of turns as that of the old one insulating, varnishing and pre heating for the following : Note: Rates are deemed to be inclusive of replacing bush, bearing, armature & capacitor of any type, size & capacity, if required as per fan condition.
(a) Ceiling fan 1200mm/1400mm sweep
(b) Exhaust fan 250mm upto 300 mm sweep
(c ) Exhaust fan above 300mm upto 450mm sweep
(d) Wall mounted fan upto 300mm sweep
Supply and fixing capacitor of 3.15 MFD complete all as specifeid and directed.
Supply and fixing capacitor of 2.5 MFD complete all as specifeid and directed.
Supply and fixing louvers of Exhaust fan of size 250mm upto 450mm sweep and removing the old, damaged and corroded exhaust fan louvers with new one, complete all as specified and directed.
Supply and fixing blades of Exhaust fan of size 250mm upto 450mm sweep as per site and removing the old damaged & corroded exhaust fan blades with new one, complete all as specified and directed.
Supply and fixing Exhaust fan support arms, nut bots & washer for exhaust fan of size upto 450mm sweep of any type & size as per site , complete all as specified and directed.
M&L for Cleaning and preparing the surfaces of ceiling fan, wall mounted fan, exhaust fan, pedestal fan, removing the grease, carbon dust over the fans and painting with two coats of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan of suitable size all as directed by Engineer-in-Charge.
Disconnecting the inlet , outlet , water connections and electric supply , taking down of Geysers (water heater) of capacity 25/ 50 Ltrs horizontal/vertical of any make/model from existing position and carrying out descaling of inner container , cleaning with suitable chemicals and materials , washing with fresh water, replacment of defective/unserviceable components if any and fixed to its original position complete all as specified and directed. Note: The rate quoted shall include the minors repairs and replacement of minor parts i.e. screw nuts, bolts washers etc .The items replacing herein after shall be measured and paid seperately.
Supply and fixing in replacement of geyser inner storage tank made of stainless steel of capacity 25Ltrs, complete all as specified and directed. Note :- Sample shall be checked at site before procurement to match the existing models.
Supply and fixing in replacement of heating element 2.00 KW capacity 230 volt suitable for geysers any type ( round/triangular)as per site requirement ISI mark complete all as specified and directed. Make: Venus/Theeta//Bajaj or equivalent. Note :- Sample shall be checked at site before procurement to match the existing models.
Supply and fixing in replacement of thermostat 7"/11" suitable for storage type water heater complete all as specified and as directd. Note :- Sample shall be checked at site before procurement to match the existing models.
Supply and fixing in replacement of PVC insulated PVC sheathed 3 core 4.00 sqmm copper conductor flexible sheathed cable suitable for geysers of any size complete all as specified and as directed.
M&L for preparing external surfaces of water heater, cleaning with emery paper & cloth and painting with two coat of synthetic enamel paint of white colour of approved make with brush and writing MES No. on it of suitable size all as directed.
Supply and fixing in replacement of Geyser assembly suitable to fix thermostat, heating elements as of the existing size including number nuts, bolt, washer as per site requirement etc complete all as directed. Note :- Sample shall be checked at site before procurement to match the existing models.
Taking down old existing unserviceable geysers of any capacity from its position, dismantling and taking out hot water tank, soldering/bracing to arrest the leakage, removing geyser outlet/inlet pipe blockages by removing deposited sediments in geyser tank, reassembling and fixing back in position and testing complete all as specified and as directed. Note :- Items required for repairs to geysers such as heating elements, thermostate etc shall be measured and paid separately relevant itmes.
Supply and fixing in replacement of Bottom inspection chamber cover suitable for 25 Ltrs capacity geyser of any make/model complete all as specified and as directed.
Supply and fixing Indication lamp (red & green) suitable for geyser in round/rectangular shape complete all as specified and as directed.
Supply and fixing of PVC connections 15mm size with PTMT nuts of length 450mm suitable for hot water all as specified and directed by Engineer -in-charge.
M&L for Lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 on 50 mm dia pipe complete all as specified and directed.
All as above item No- 67 but on 25 mm dia pipe
All as above item No- 67 but on 20 mm dia pipe
S&F Rotational moulded polyethylene water storage tanks of 500 lts capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I Note: Rate are deemed to be inclusive of transportation charges and shifting of tank on roof top of bldg any floor.
S & F in replacement of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) of 20mm dia, complete all as specified and directed. Note: Thread cutting to inlet pipe and fixing GI reducer of 25x20mm dia is deemed to be included in quoted rate.
S & F in replacement of Flat solar plate collector panels suitable for 100LPD solar water heater, free stand type, with copper tubings of suitable size enclosed in toughed glass from top and metal sheet base with back ground painted with black colour and PUF insulated of size as per site requirment, complete all as specified and directed by EIC. NOTE: 1) Panel should be BIS and CEC approved. 2) All accessories required at site for installation is deemed to be included in quoted rate. 3) Contractor must check size of panel as per existing before procurement.
Comprehensive Annual Maintenance Contract of central Air conditioning Plant of Capacity 3 x 55 TR including Sundays & Holidays for respective equipments as listed below:- (a) Periodical, preventive and comprehensive maintenance complete package chiller units each consisting of 3 x 55TR chiller units along with motor and its condenser,microprocessor based control panel complete system including submission of preventive periodical service reports. Total no of package chiller units -03 Nos. (b) Preventive, Comprehensive and routine maintenance of following equipments:- (i) Primary Chiller pump sets along with motors -03 Nos. (ii) Secondary Chiller pump sets along with motors -03 Nos. (iii) Chiller water pipe lines and its control valves – lot. (iv) Electrical operated hot water generator of Cap 63 KW complete with automatic and safety controls such as safety valve, purge valve, high limit cut out, automatic and manual reset, low level cut out stop controller, thermostat, heaters including its control panel-01 No. (v) Hot water pump set along with motor and control valves controls provided at each pump set-02 Nos. (vi) Hot water piping, insulation, fittings control valves connected between hot water unit to pump set and pump set to various AHUs-Lot. (vii) AHUs complete with accessories such as casing, chilled water coil, hot water coil, any type of air filters, drive motors control panel etc complete 3 Nos AHUs. (viii) Controls for AHUs comprising of three way mixing valves with modulating motor, thermostat and humidistat-Lot. (ix) Cubical type floor mounted main LT panel consisting control switch gear, starters of pump sets, cooling towers and its single phase preventers, no volt and under volt protection system, meters indication lamps complete-01 No. (x) Sub control panel provided for AHUs including controls starter meters and protection system -03 Nos. (xi) Central control console panel comprising of ON/OFF push buttons and ON/OFF indication lights -01 No. (xii) Chiller /condenser control units/ display unit, Contactors, MCCB/MCB, filters, stainers, drier filters, valve, thermometers, NRV, wiring or other any defect related to units. (xiii) Repair to AHU's induction motors, belts, fan, relays, actuators, motoried valve or any other type defects including abnomal sounds from AHU's. (xiv) Cleaning/washing of chiller/condenser unit, AHU Pre filters with pressuriezed water and detergent etc. periodically to remove dust and scale formation due to natual calamities.
(xv) Repair to pin hole in scroll compressor and topping up with compressor oil and refigerant gas is deemed to be included rate. Rates are deemed to be inclusive of Gas charging as per OEM specification, compressor oil, cutting of copper tube or any other items like thermometer, heating belt, any fittings, rubber cushions, pressure gauge, Manpower and T&P required at site.
Comprehensive and Running maintenance of central Air conditioning Plant of Capacity 3 x 25 TR including Sundays & Holidays for respective equipments as listed below:- (a) Periodical, preventive and comprehensive maintenance complete package chiller units each consisting of 3 x 25TR water cooled screw chiller units along with motor and its condenser,microprocessor based control panel complete system including submission of preventive periodical service reports. Total no of package chiller units -03 Nos. (b) Preventive, Comprehensive and routine maintenance of following equipments:- (i) Chiller pump sets along with motors -03 Nos. (ii) Condenser water pump sets along with motors -03 Nos. (iii) FRP cooling towers complete with motor, fan, gear box (iv) Condenser water pipe lines and its control vales complete-Lot. (v) Chiller water pipe lines and its control valves – lot. (vi) AHUs complete with accessories such as casing, chilled water coil, drive motors control panel etc complete 3 Nos AHUs. (vii) Controls for AHUs comprising of three way mixing valves with modulating motor, thermostat and humidistat-3 Nos. (viii) Cubical type floor mounted main LT panel consisting control switch gear, starters of pump sets, cooling towers and its single phase preventers, no volt and under volt protection system, meters indication lamps complete-01 No. (ix) Sub control panel provided for AHUs including controls starter meters and protection system -03 Nos. (x) Central control console panel comprising of ON/OFF push buttons and ON/OFF indication lights -01 No. (xi) Chiller /condenser control units/ display unit, Contactors, MCCB/MCB, filters, stainers, drier filters, valve, thermometers, NRV, wiring or other any defect related to units. (xii) Repair to AHU's induction motors, belts, fan, relays, actuators, motoried valve or any other type defects including abnomal sounds from AHU's. (xiii) Cleaning/washing of chiller/condenser unit, AHU Pre filters with pressuriezed water and detergent etc. periodically to remove dust and scale formation due to natual calamities.
(i) The tender shall have to replace the U/S material with OEM materials only. The Cost of replacement major/minor spare parts not to paid separately, old materials will be contractor property & included in the rate quoted (ii) In Case any accident occur of any indl like mechanic/helper/user during maintenance of above mentioned Air conditioner/Unit. The Contractor is liable to pay compensation to the indl as decided by the contractor authority. Principal employer will not be responsibile for the same. (iii) If complaint not attended by the contractor with in 5 hrs the penalty of Rs 1000/- per hrs to be imposed & amt of penalty will be deducted from RAR. (iv) The cost of transportation (to & fro) for all kind of necessary equipment T & P shall be arranged/brought by the conractor to complete the job at site, stationery for maintenance of record. No extra cost shall be paid to the contractor to this effect. (v) Complaint shall be lodged by telephonically, so the contractor to specify the telephone No who will receive the complaint round th clock, After attending the complaint contractor will obtain the signature from rep of users/AGE/GE every day on a token of Complaint attended.
Dismentaling & Reinstallation of Compressor. Dismentaling & Reinstallation of EXV, Dismentaling & Reinstallation of Drier, Leak Testing, N2 Pressure Testing, Flashing, Vaccumization, Refregrent Charging and commisioning of (XWCS2026AR2) Chiller Units complete all as specified and as directed.
Supply & Charging of Refrigrent for compressor of centralised AC plant complete all as specified and as directed.
Supply & Installation of Contactor 16 A complete all as specified and as directed.
Supply & Installation of Contactor 63 A complete all as specified and as directed.
Descaling or Wet wash Service with chemical of Condenser complete all as specified and as directed.
Wet Wash Service with Chemical Of AHU complete all as specified and as directed.
Supply & Installation of Motorized Valve complete all as specified and as directed.
Supply & Installation of Analog Temp. Meter complete all as specified and as directed.
Supply & Instalation of Digital Volt meter complete all as specified and as directed.
Supply and instalation of Insullation for Chilled Water Pipe Line complete all as specified and as directed.
Supply and instalation of Insullation for Hot Water Pipe Line complete all as specified and as directed.
Supply of Compressor SZ185 for (XWCS2026AR2) Chiller Units HSN 84148011 complete all as specified and as directed.
Supply of FILTER DRIER 023Z0014 DCL 305 5/8 For (XWCS2026AR2) HSN( 84213920 ) complete all as specified and as directed.
Supply of EXP VALVE-HFES-10 For (XWCS2026AR2) HSN (848180500) complete all as specified and as directed.
Supply of DX CONTROLLER(LCD)3COMP AC (TANDEM) for (XACYS2060R2) HSN (85381010) complete all as specified and as directed.
Material & labour for Provision of descaling in water water pipe lines of condensor coil in central Air conditioning Plant of Capacity 3 x 25 TR including MS pipe cutting, joints etc complete all as specified and as directed.
Supply and fixing fire Hydrant valve single headed of size 63mm dia with reel locking and CI wheel, complete all as specified and direceted.
S&F Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard, complete all as specified and directed. Note: 1) Painting and changing new locks and glass of exiting serviceable boxes (20 Nos) as per required is deemed to be included in quoted rate
S&F pump CI stainers for suction, flange/threaded as per site, complete all as specified and directed of size upto 100mm dia.
Maintenance and servicing of 3 phase Online UPS of capacity 40 KVA make Sukam at Auditorium. AMC include following scope of work: (i) Repair replacement of worn out parts. (ii) Checking and rectifying/replacing PCB boards, logical units, LED light, LED display, logic control units, push button, switches, voltmeter, ammeter, cooling fan and motor, MCCB, MCB, transformer, insulators, bus bars, voltage stablizing unit, battery lugs and terminals and internal and external wiring. (iii) Servicing, oiling, greasing and checking periodical or as when required. (iv) Periodically checking and performing test like earth test, battery checking, battery backup checking and maintaining battery back up of 45min at any instant.
Saini Enterprises
SNOWY ENGINEERING INC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .