Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST TENDER L1 | |
| 2 | L2₹46.0 L+₹2.0 L (4.52%)Rejected-Finance 184 C 13 THURAIYUR SAMINATHAN NAGAR PERAMBALUR SALAI TIRUCHIRAPPALLI TAMIL NADU 621010 UDYAM TN 27 0052941 | TIRUCHIRAPPALLI | TAMIL NADU | 621010 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹49.2 L+₹5.2 L (11.8%)Rejected-Finance 5 127 16 GANESH GARDEN KADAMPADI SULUR COIMBATORE TAMILNADU 641401 | COIMBATORE | TAMIL NADU | 641401 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹49.6 L+₹5.6 L (12.8%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹49.7 L+₹5.7 L (12.9%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
| Sl No | Description | Qty | Unit | NAVEEN ENTERPRISES L6 | CAK Enterprises L3 | KRISHNA ENTERPRISES L4 | NLK Construction L2 | KUMAR AGENCIES L7 | D.R ASSOCIATES L1 | A.S Enterprises L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A BOQ | ||||||||||
| 2.00 | Attending unserviceable/ non functional hanger/wall/surface Highbay/Midbay/low bay/flood light complaints (for lights etc of any type/size fitted on poles/walls/post/pillars/hangers etc) by deploying technically qualified and experinced techinicians to find out defective/taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed for at complete AF Station(technical area) Sulur | 842 | Each Job | 325 ₹2,73,650 | 400 ₹3,36,800 | 350 ₹2,94,700 | 100 ₹84,200 Lowest | 400 ₹3,36,800 | 340 ₹2,86,280 | 400 ₹3,36,800 |
| 2.01Note for item No 02: The following items are deemed to be inclusive of quoted rate :- | ||||||||||
| 2.02(a) The above job shall be carried out by a trained skilled electrician shall be produced before commencement of work. | ||||||||||
| 2.03(b) 'Supply only' items to be delivered/ supplied to AGE E/M store yard as per qty asked by Engineer-in-Charge with in one calender month from the date of commencement of contract and these items will be issued from AGE E/M store yard for attending unserviceable/ defective street light complaints. | ||||||||||
| 2.04(c) Contractor or his Authorised Representitive has to inspect all Hanger/flood Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day. | ||||||||||
| 2.05(d) A Joint Inspection for Serviceability of all Hanger Lights will be carried out from 7.00 PM to 9.00 PM on every FRIDAY by Engineer-in-Charge/ JE (E/M)/ User alongwith Contractor or his authorised Representitive. | ||||||||||
| 2.06(e) Contractor has to arrange own T&P for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. | ||||||||||
| 2.07(f) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Hangers Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments to remove the breakdown. Fault will be intimated through Telephone/ SMS. | ||||||||||
| 2.08(g) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. | ||||||||||
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
6 Aug 2025, 6:00 pmClosed
GE AF SULUR
KANGAYAMPALAYAM
REPAIR/ MAINT OF HIGH BAY LIGHTS/MID BAY LIGHTS/LOW BAY LIGHTS/ INDUSTRIAL POWER SUPPLY SERVICES HANGAR MOTORS, COMPREHENSIVE MAINT OF SMART PREPAID ENERGY METERS, HANGAR EARTHINGS AND MISC E/M WORKS IN CERTAIN AREA AT AFS SULUR
2025_MES_721017_1
8781/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please refer to tender document
7 documents required · 7 mandatory
₹500
GE AF SULUR
₹92,000
28 Sept 2025
17 Jul 2025
8 Aug 2025
17 Jul 2025
6 Aug 2025
30 Jul 2025
20 Jul 2025 - 28 Jul 2025
Amount
SCHEDULE A BOQ
Attending unserviceable/ non functional hanger/wall/surface Highbay/Midbay/low bay/flood light complaints (for lights etc of any type/size fitted on poles/walls/post/pillars/hangers etc) by deploying technically qualified and experinced techinicians to find out defective/taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed for at complete AF Station(technical area) Sulur
Note for item No 02: The following items are deemed to be inclusive of quoted rate :-
(a) The above job shall be carried out by a trained skilled electrician shall be produced before commencement of work.
(b) 'Supply only' items to be delivered/ supplied to AGE E/M store yard as per qty asked by Engineer-in-Charge with in one calender month from the date of commencement of contract and these items will be issued from AGE E/M store yard for attending unserviceable/ defective street light complaints.
(c) Contractor or his Authorised Representitive has to inspect all Hanger/flood Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day.
(d) A Joint Inspection for Serviceability of all Hanger Lights will be carried out from 7.00 PM to 9.00 PM on every FRIDAY by Engineer-in-Charge/ JE (E/M)/ User alongwith Contractor or his authorised Representitive.
(e) Contractor has to arrange own T&P for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair.
(f) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Hangers Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments to remove the breakdown. Fault will be intimated through Telephone/ SMS.
(g) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(h) The penalty shall be applicable to the contractor if the delay is noticed by the JE/Engr-in-Cahrge more than twelve hrs after handing over works of urgent nature to the contractor. The JE/Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the double rate per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforceabove as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regards shall be final and binding.
(j) Contractor has to ensure serviceability of Hanger lights on Daily basis in any Weather Condition at their own arrangement.
(k) Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department.
(l) Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department.
(m) Materials required for the repairing of the lights shall be measured and paid separately under respective item(s). But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall deemed to be included in the rate quoted.
(n) Necessary T&P, Safety Belt, Vehicle, Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
(o) All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part.
(p) All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
(q) Attending and repairing complaint for one light of any type shall be measured and paid as one Job.
(r) Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
(s) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
(t) Contractor shall provide contact details of his responsible person(s) for any emergency.
(u) Any Materials replaced which are not specified in SCHEDULE OF CREDIT will be deposited to MES STORE YARD without any extra Cost to the Department.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 270Volt and output voltage suitable for LED light fitting of capacity 10 to 25 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 270Volt and output voltage suitable for LED light fitting of capacity 30 to 45 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 270Volt and output voltage suitable for LED light fitting of capacity 60 to 90 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 270Volt and output voltage suitable for LED light fitting of capacity 100 to 110 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 270Volt and output voltage suitable for LED light fitting of capacity 140 to 160 watt, complete all as specified and as directed.
M & L for disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the up to 35 sqmm 3.5 core size of LT underground armoured cables complete all as specified and directed.. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
Disconnecting & taking out unserviceable one and replacemet with new metal clad switch socket triple pole ,neutral and earth enclosure with three pin and earth plug with socket complete with on triple pole 20 Amps, 415 Volts MCB complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new metal clad switch socket triple pole ,neutral and earth enclosure with three pin and earth plug with socket complete with on triple pole 32 Amps, 415 Volts MCB complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new metal clad switch socket triple pole ,neutral and earth enclosure with three pin and earth plug with socket complete with on triple pole 63 Amps, 415 Volts MCB complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new metal clad switch socket single pole ,neutral and earth enclosure with three pin and earth plug with socket complete with on SPN 20 to 32 Amps, 230 Volts MCB complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new LED hibay fitting complete with housing -IP 65 pressure Die cast Aluminum Housing with manufacturers logo embossed on the housing optics- lens with lens plate having symmetric optics for optimization of design system Efficacy> 100-2-13 certification like CE. ENEC. ROHS. DALI compatible with reted life of up to 50000 Hrs for Driver at TC-80 deg C along with all safety features thermal protection . protection against input over voltage > 320 VAC for 48 Hrs Driver Failure Rate < 02% per 1kHr@ TC 70-80 Deg CDriver Efficiency-93% atMax Load System Lumens- 14500.system wattage -140 watts internal wiring -teflon .SDCM <15%PF95.optics designed 4 synnetric distributtion at 60 degree complete with necessay fixing arrengements all as directed .
Disconnecting & taking out unserviceable one and replacemet with new 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid/surface/roof including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from notless than 110 lumens/watt.The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection not less than 2KV ,permisible limit of CRI range,with recommended burning hours,4000K/5700k/6500K etc frequency 50 to 60 Hz ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , . PF should be notless than 0.95 , THD < 10% . Indivisual LED's should not be visible for glare free output
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board VTPN, 3-ph,12 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCCB 63-125Amps,minimum 3pole & minimum kA rating is 16kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board VTPN, 3-ph,8 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCCB 63-125Amps,minimum 3pole & minimum kA rating is 16kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board VTPN, 3-ph,6 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCCB 63-125Amps,minimum 3pole & minimum kA rating is 16kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board VTPN, 3-ph,4 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCCB 63-125Amps,minimum 3pole & minimum kA rating is 16kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board TPN, 3-ph,4 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCB 40-100Amps,minimum 3pole & minimum kA rating is 10kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board TPN, 3-ph,8 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCB 40-100Amps,minimum 3pole & minimum kA rating is 10kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board TPN, 3-ph,12 way double door,415volts,50Hz including bus bar capacity not less than 200Amps , Neutral bar, standard DIN rail, earth bar with incoming MCB 40-100Amps,minimum 3pole neutral & minimum kA rating is 10kA as incomer flush to wall/surface conforming to IS and making good of distructed surface including taking down old one complete
Disconnecting & taking out unserviceable one and replacemet with new SPN 40 to 63 AMP, 240 v, 50 Hz AC suitable forcurve, 10 KA breaking capacity complete conforming to IS all as specified.
Disconnecting & taking out unserviceable one and replacemet with new TP, MCB 25 to 63 amp, 415 v, 50 Hz AC suitable (load curve shall be provided as per exisitng loads), 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified.
Disconnecting & taking out unserviceable one and replacemet with new TP, MCB 40 to 100 amp, 415 v, 50 Hz AC suitable (load curve shall be provided as per exisitng loads) , 10 KA breaking capacity complete conforming to IS all as specified.
Disconnecting & taking out unserviceable one and replacemet with new single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for exisiting loads(curve shall be provied as per existing loads 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified.
Disconnecting & taking out unserviceable one and replacemet with new single pole MCB SPN 6 to 32 Amps, 240 v, 50 Hz AC suitable for exisiting loads(curve shall be provied as per existing loads 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified.
Supply and fix modular switch 1 way 6 amp.1 module complete all as specified and directed.
Supply and fix modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix modular switch 1 way 16 amp.1 module complete all as specified and directed.
Supply and fix modular Socket, 16A - 3/5 pin combined 2 module complete all as specified and directed.
Supply and fix modular white cover plate with frame,3 module complete all as specified and directed.
Supply and fix modular white cover plate with frame,4 module complete all as specified and directed.
Supply and fix modular white cover plate with frame,6 module complete all as specified and directed.
Supply and fix switch socket combination outlet 3 in 1/ 3 pin 3 and 5 amps flush type with box complete all as specified and as directed.
Supply and fix switch socket combination outlet 5 in 1/ 5 pin 5 and 15 amps flush type with box complete all as specified and as directed.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed. Note:- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two runs of 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring complete all as specified and as directed. Note:- (a) 4 runs of 10 sqmm cable along with two runs of 10 sqmm cable for earth conductor and one run of PVC Casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and incl suitable size non metalic PVC conduit and all accessories fixed to wall/floors along with two runs of 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring complete all as specified and as directed. Note:- (a) 4 runs of 10 sqmm cable along with two runs of 10 sqmm cable for earth conductor and one run of PVC Conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make of conduit : Avon Plast/ Supreme/ Diplast or equivalent approved make. Make of Cable : Plaza/Polycab/Havells or equivalent approved make.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC Conduit and all accessories fixed to wall/floors/surafce along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note:- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of load & source cable end terminations with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for wiring for circuit complete submain wiring with 2 X1.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size complete all as specified and directed Note:- (a) 2 runs of 1.5 sqmm cable along with one run of 1.5 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Disconnecting & taking out unserviceable one and replacemet with new MCCB four pole, 63 -100 Amp ultimate breaking capacity minimum 16 KA complete conforming to IEC -61439-1 complete all as specified and directed
M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed.
One light point/fan/bell point controlled by one switch
All as per item No. 43 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 43 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 43 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through medium grade open Steel conduit with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch
All as per item No. 44 here in before but for One switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 44 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Disconnecting & taking out unserviceable one and replacemet with new 4 feet 18/20 Watt LED light fitting batten type with Luminaries & integrated driver batten with lumen out notlessthan 110 lumens/watts & extruded polycorbanate housing square shaped diffuse suitable for mounting on wall/surface/ceiling 230 volts with extruded aluminium heat sink provided for efficient heat dissipation,permisible limit of CRI range,with recommended burning hours,4000K/6500K etc complete with all accessories internally pre wired and necessary mounting arrangements, including provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including taking down old unserviceable fittings any type complete all as specified and as directed .
Disconnecting & taking out unserviceable one and replacemet with new S&F 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid/surface/roof including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from notless than 110 lumens/watt.The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection not less than 2KV ,permisible limit of CRI range,with recommended burning hours,4000K/6500K etc frequency 50 to 60 Hz ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , . PF should be notless than 0.95 , THD < 10% . Indivisual LED's should not be visible for glare free output ,colour temperature 6500k all as directed.
Periodical servicing and maint of electric operated hanger door comprising of 3 phase, 415V, 5.5 KW/ 7.5 HP capacity induction motor of Make - Siemens, 7HP VFD panel, chain pulley arrangement, push button for forwarding/ reverse movement of the doors, relays, limit switches, contactors, gear wheels, siren, ammeter and voltmeter, indicating lamps, MCB SP/ SPN of various capacities and suitable connecting cable etc. complete all as specified and directed by Engineer-in-Charge.
Note :- (a) Each hanger consists of 04 Nos of electric operated door.
(b) Preventive maintenance of each hanger door i.e greasing, reallignment, welding will be done by Service engineer from M/s Siemens .
(c) The unit quoted rate shall deemed to be included to carried out all repairs noticed.
(d) Repairs/ maintenance shall be carried out through the experinced service agency only.
(e) The service agency must be attended as and when called for urgent nature of repair of hanger door irrespective of number of visit.
(f) Replacement of minor items shall be included in the unit quoted rate.
(g) Replacement of any major defective items will not be included in the scope of work. However, the decision of Accepting Officer is final and binding whether the defective item is major or minor in nature.
M&L for rewinding of burnt electric induction motor of 3 phase, 415 volts, 5.5 KW/ 7 HP Make - Siemens including disconnecting electric connections/ taking down and shifting to local workshop and brought back to site and re-assembling, connecting, testing complete all as directed by Engineer-in-Charge.
Periodical servicing and maint of electric operated hanger door comprising of 3 phase, 415V, 3.75 KW/ 5 HP capacity induction motor of Make - Siemens, 7HP VFD panel, chain pulley arrangement, push button for forwarding/ reverse movement of the doors, relays, limit switches, contactors, gear wheels, siren, ammeter and voltmeter, indicating lamps, MCB SP/ SPN of various capacities and suitable connecting cable etc. complete all as specified and directed by Engineer-in-Charge.
Note for item No 50 :- (a) Each hanger consists of 04 Nos of electric operated door.
(b) The unit quoted rate shall deem to be included to carried out all repairs noticed.
(c) Repairs/ maintenance shall be carried out through the experinced service agency only.
(d) The service agency must be attended as and when called for urgent nature of repair of hanger door irrespective of number of visit.
(e) Replacement of minor items shall be included in the unit quoted rate.
(f) Replacement of any major defective items will not be included in the scope of work. However, the decision of Accepting Officer is final and binding in deciding, whether the defective item is major or minor in nature.
M&L for rewinding of burnt electric induction motor of 3 phase, 415 volts, 3.75 KW/ 5 HP Make - Siemens including disconnecting electric connections/ taking down and shifting to local workshop and brought back to site and re-assembling, connecting, testing complete all as directed by Engineer-in-Charge.
Taking down of wall mounted fan/Aircircuilator any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling . (Note:- Repair, rewinding, over hauling and materials to be replaced are measured seperately.)
M&L for winding of pedastal fan/wall monted/Air circulators of up to 630 mm sweep of any make, cleaning the slots with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only.
Supply and fix fan bush of suitable size for peadstal fan of any sweep
Supply and fix fan bearing of suitable size for peadstal fan of 630 mm sweep
Supply and fix fan bearing of suitable size for wall mounted fan of 400 mm sweep.
Supply and fix bush of suitable size for wall mounted fan of the any sweep
Disconnecting & taking out unserviceable one and replacemet with new Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V.
Disconnecting & taking out unserviceable one and replacemet with new LED flood light fitting 160 Watt flame proof, CMRI certified recommended for sun shelter for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Disconnecting & taking out unserviceable one and replacemet with new switch flame proof switch socket and plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P + earth,
M&L for comprehensive operation and maintenance of system(3-ph meters-150 Nos ,1-ph meters -1750 Nos) incl project implementation and management, all expenditure including periodic charges of telecom operator, smart meter billing and maint all as directed by Engr-in-Charge.
Note: (i) All available energy meters are M/s Secure ltd IS-16444 (ii) Quoted rates deemed to be includes telecom netwrok charges,NB-IOT ,OTP charges for User and service provider & DLT charges. (iii) Quoted rates deemed to be includes OEM meter token genaration and same shall be reflected in meter and user account. (iv) Contractor should take MOU with M/S Secure server located GE AF Subrata Park, Palam for maintain of meters.
Server monitoring & maintained to operate smooth functioning MES TVS Server.
NLK Construction (BID ID -3384442)
CAK Enterprises (BID ID -3384169)
KRISHNA ENTERPRISES (BID ID -3384189)
A.S Enterprises (BID ID -3385172)
NAVEEN ENTERPRISES (BID ID -3384139)
KUMAR AGENCIES (BID ID -3384458)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .