Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹13.7 L+₹1.0 L (8.14%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹13.9 L+₹1.2 L (9.69%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹14.0 L+₹1.3 L (10.2%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹14.2 L+₹1.5 L (12.0%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹14.6 L
EMD Value
₹29,140
Closing Date
23 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Pune
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
81736 PROVN OF WORK SERVICES FOR INSTALLATION OF SUPER DIMONA TC SIMULATOR BY ADDITION/ ALTERATION IN OLD HANGER AT AFTT AT NDA KHADAKWASLA UNDER GE NDA KHADAKWASLA
2023_MES_592768_3
81736
Open Tender
Civil Works
Works
180 days
Khadakwasla
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (NDA) KHADAKWASLA
₹29,140
Yes
3 Nov 2023
3 Aug 2023
25 Aug 2023
3 Aug 2023
23 Aug 2023
10 Aug 2023
Amount
Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including cleaning off premises and removing rubish off outside of MD land complete all as specified & directed by Engineer Incharge.
M&L 75 mm thick PCC (1:4:8) type D2 using 40 mm graded aggregates as in sub base including necessary formwork complete all as specified & directed by Engineer Incharge.
S& F Virified Ceramic tiles dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match including screed of 15mm thick cement mortar (1:6) complete all as specified & directed by Engineer Incharge.
M&L plastering 15 mm thick in CM 1:6 on wall including rendering is to be finished even and smooth (without using extra cement) including taking down plaster, racking out joint complete all as specified & directed by Engineer Incharge.
M&L for plastering 10 mm thick in CM 1:3 on ceilling including rendering is to be finished even and smooth (without using extra cement) incl taking down plaster, racking out joint complete all as specified & directed by Engineer Incharge.
M&L for applying 3mm thick wall care putty including two coat of plastic emulsion / Luster paint on walls surfaces incl preparation of surfaces complete all as specified & directed by Engineer Incharge.
M&L for applying 3mm thick wall care putty including two coat of plastic emulsion / Luster paint on ceiling surfaces incl preparation of surfaces complete all as specified & directed by Engineer Incharge.
M&L for Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified & directed by Engineer Incharge.
S&F Anodised aluminium snap grid frame work for false ceiling , the aluminium sections incorporated in frame work shall conform to IS 733, IS 737 and IS 1285. The snap grid consist of anodized aluminium main/cross tee of size as indicated. Snap grid frame work shall be fixed to ceiling with supporting hanger consisting of 6mm dia mild steel rod, J bolts with necessary bolts, nuts and washers all as manufacturer’s instruction. The main and cross tees shall be jointed at junction/crossings with anodized aluminium angle bracket of size as indicated, if not indicated it shall be 15mmx15mmx1.5mm, weighing 0.12 Kg per running metre, fixed with sutiable mild steel, bolts nuts and washers, all as per manufacturer’s instructions. The snap grid (main/cross tee section) shall be supported at ends all along the wall with anodized aluminium angle of size as indicated, if not indicated it shall be 40mmx25mmx2mm, weighing 0.36 Kg per running metre. Size of the snap grid shall be as indicated complete all as specified & directed by Engineer Incharge.
Taking down chowkhats or frame not exc 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified & directed by Engineer Incharge.
Taking down chowkhats or frame not exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) complete all as specified & directed by Engineer Incharge.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and incl 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specified & directed by Engineer Incharge.
Providing and fixing factory made uPVC any colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (± 0.2mm). Window profile with hollow section with multi chamber. Frame(88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (Onevertical length in each shutters) (45.5mm x 28mm),Glazing bead (24.5mm x 16mm) shall be miterd cutand fusion welded at all corners, including drillingof holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 ± 0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame shall be fixed tothe wall with 8mm x 100mm long fasteners, Hardware Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) complete all as specified & directed by Engineer Incharge.
Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 42x50 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and complete all as specified & directed by Engineer Incharge.
S&F for factory made uPVC white colour Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Areaof door above 2.00 sqm upto 5.00 sqm) comprising of uPVC multi-chambered frame, with in-built roller track and sash extruded profiles duly reinforced with 1.60 ±0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC, extruded glazing beads, uPVC extruded interlock and uPVC extruded line sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extrem panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof siliconsealent over backer rod of required size and of approved quality, (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made complete all as specified & directed by Engineer Incharge.
S&F for Steel rolling shutters 1mm thick, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of red oxide primer; erected in position as indicated, complete, gear operated type with bevel gear box and crank handle complete all as specified & directed by Engineer Incharge.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed by Engineer Incharge.
S&F in repair Sheet glass 3 mm thick ordinary quality and glazing with oil putty incl wooden beads supply & fixing in square n exc 0.5 sqm in each panel complete all as specified & directed by Engineer Incharge.
S&F in repair Sheet glass 5.5 mm thick ordinary quality and glazing with oil putty incl wooden beads supply & fixing in square n exc 0.5 sqm in each panel complete all as specified & directed by Engineer Incharge.
S&F Solar control film 50 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified & directed by Engineer Incharge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified & directed by Engineer Incharge.
S&F for framed work as in doors or gates of angles or other section with gussest plate, rails, braces,etc complete drilled for fixing of steel sheeting or other covering door etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting incl of steel sheeting or other covering , running railand guides and hanging, also fastening and fixing complete all as specified and as directed by Engr in Charge
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge
S&F Anodised aluminium frame powder coated for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified & directed by Engineer Incharge.
M&L for 18/19 mm thick Block boards, grade 2 quality, i n t e r i o r grade, decorative type with decorative face veneer on both faces complete all as specified & directed by Engineer Incharge.
M&L for Elegant Tile made of perforated cement fiber composite 595x595/295X1195/595X1195x5mm covered with absorptive microfiber coating on the front side and Acoustics fiber on the back side, water resistance, fire resistant absorption coefficient upto 0.89 at 160 Hz tested as per ISO 354. The tiles are anti-sag and installed on with & including T24 grid system of 0.6mm thick Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results complete all as specified & directed by Engineer Incharge.
M&L precast cement concrete 1:3:6 type C-1 (using 20mm course graded aggregate) block masonry with solid blocks exc10 cm thick in width and setting in cement mortar 1:6 including demolition of brick / block masonry / Stone masonry built in Cement mortar complete all as specified and directed by Engineer Incharge.
M & L Cement concrete type C- 2, 1:3:6 (40mm course graded aggregate) 75 mm thick as in plinth protection complete all as specified and directed by Engineer Incharge.
S&F Harrison rails 20mm dia, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed by Engineer Incharge.
M&L for two coats of synthetic enamel paint over a coat of Red oxide primer including preparation of new steel/iron surface of any description over 10 cm in width or girth complete all as specified and directed by Engineer Incharge.
S&F for T type brackets decorative type powder coated suitable for 20 mm dia complete all as specified and directed by Engineer Incharge.
M&L for Prelaminated particle board 9mm thick , exterior grade, prelaminated both side with decorative choice lamination & prelaminated both sides with decorative choice laminations fixed with screws to timber frame work complete all as specified and directed by Engineer Incharge.
M&L for Cutting chases for concealed conduit wiring, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface complete all as specified and directed by Engineer Incharge.
M&L for point wiring in and including new concealed stove enamelled steel conduit 20mm with the help of multi-stranded unsheathed FRLSH copper cable 1.5 sqmm 650/1100V conforming IS:3419 -1988 adhereing to colour code including earth wire of the size 1.5 Sqmm green colored with modular steel or cast iron terminal boxes and modular cover plates as required at site including making good the distrubed surfaces and matching it with existing surface for the following :-
One light /fan point controlled by one switch one way
One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq. mm size
M&L for point wiring in and including new concealed stove enamelled steel conduit of dia not less than 20 mm with the help of multi-stranded unsheathed FRLSH copper cable 4 sqmm 650/1100V conforming IS : 3419 -1988 adhereing to colour code including earth wire of the size4 Sqmm green colored with terminal boxes as required at site steel or cast iron as indicated and shall conform to IS 14772-2000 including making good the distrubed surfaces and matching it with existing surface including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit
S&F modular switch one way 6 Amp, 1 module complete all as specified and directed by Engineer Incharge.
S&F modular switch one way 16 Amp, 1 module complete all as specified and directed by Engineer Incharge.
S&F modular Socket, 6A - 2/3 pin,2 module complete all as specified and directed by Engineer Incharge.
S&F modular Socket, 16A - 2/3 pin,2 module complete all as specified and directed by Engineer Incharge.
S&F ceiling rose surface shall comply with IS :371-1979 Bakelite 60x 25 mm two to three terminals plates and of outside diameter not less than 63.5mm complete all as specified and directed by Engineer Incharge.
M&L for LAN socket with transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module complete all as specified and directed by Engineer Incharge.
S&F factory made epoxy powder coated Distribution Board TP & N 8 way double door (VTPN MCCB DB) MCCB as In comer, and MCB as outgoing with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified and directed by Engineer Incharge. Note: (i) MCCBs and MCBs will be measured and paid seperately under respective Sch A item in this schedule
S&F MCCB with rating of 125 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (ICS) should be equal to ultimate breaking capcity (ICU) MCCB should be with suitable spreaders and phase barriers for each terminals complete all as specified and directed by Engineer Incharge.
S&F MCB DB 08 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete as reqd at site complete all as specified and directed by Engineer Incharge.
S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed by Engineer Incharge.
S&F MCB SPN 40 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed by Engineer Incharge.
M&L for supply, installation, testing and commissioning of chemical earthing (maintenance free earthing) of copper bonded elecrode size 80mm X 6 mtr long 250 micron with ground enhancing backfill compound duly fixed with connector at top connection of copper strip 50X6 mm riveted /nut bolt after 12 mm boring and further earth continuity conductor made of copper strip 50X6 mm upto 7.5 meter with 100 KGS BFC including providing FRP pit cover of size 250mmX260mmX330mm complete as per manufacturer specification complete all a specified and directed by Engineer-in-charge. Note:- (i) Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed. (ii) Earthing result upto 2 Ohm shall be achieved. (iii) Earth strip beyond 7.5 m shall be measured and paid separately. (iv) Rate is included for boring of earthing of dia 150 mm X6 m in any type of strata.
S & F copper earth continuity conductor or main earthing lead of size 25 x 3 mm fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situtation for earthing etc. as required complete all as directed by Engineer-in -charge.
S&F Porcelain insulator suitable to fix copper strip of 25 x 3mm complete all as directed by Engineer-in -charge.
M&L for Earth connector made out of copper strip 25 x 3mm, 60 cm length suitable for 2 inlet earth connection & 6 outlet earth connection with brass nut bolts & washers complete all as directed by Engineer-in -charge. (For Earth continuity to Equipment Suppy distribution boards)
S&F surface mounted LED Panel lights size of 600mm x 600MM x 35mm 40 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver.
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with conduit accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed by Engineer Incharge. (Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping/conduit shall be measured as one RM)
S&F Modular AC Box for 20 A SP MCB, with recess mounted Unbreakable Heavy Duty Plastic Enclosure including 1 nos ISI marked Plug Top and 1 nos 20 A SP modular MCB complete all as specified and directed by Engineer Incharge.
S&F for ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engineer Incharge.
Supply and install Hi wall split type AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser dual invertor type compressor,copper tube condensing unit with CFC free gas for better indoor air quality with minimum 5 star rating of capacity 2.0 TR single phase including additional copper piping, cabling work, insulation between indoor unit to outdoor unit and provision of MS Brackets for resting of outdoor units (where reqd) or making resting platform of outdoor unit by brick works complete all as specified and directed by Engineer Incharge.
S & F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA suitable for dual invertor AC complete all as specified and directed by Engineer Incharge.
M&L for sub main wiring 3 runs of 4 sqmm ( phase , neutral and earth) PVC insulated (heavy duty) 1100 volts grade, FRLSH, with stranded copper conductor in & including PVC casing caping of suitable size not less than 25mm (3 run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit) complete all as specified and directed by Engineer Incharge. (from distribution board to metal clad switch socket point near AC)
Supply & laying in trenchs or fixing on wall with saddle and testing cable XLPE insulated screened, PVC bedded galvanizer steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with standard Aluminium conductor of size 16sqmm 4 core complete all as specified and directed by Engineer Incharge.
S & F sheet metal MCB DB 4 way (double door) VTPN with 200 Amps rated copper bus bar suitable for 100 Amp MCCB incomer and 4 Nos of40 Amp MCB SPN outgoing complete all as specified and directed by Engineer Incharge.
S &F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amp complete all as specified and directed by Engineer Incharge.
M&L for PVC pipe 20 mm dia heavy duty with all fittings and fixing accesssories such as coupler, lock nut, saddle, pipe hook and laid on floor/Wall (For Drain line) complete all as specified and directed by Engineer Incharge.
S&F for MCCB, 4 Pole 415 Volts, 100Amps having breaking capacity 16KA complete all as specified and directed by Engineer Incharge.
M & L for making holes by core cutting machine on stone/concrete / brick walls.Dia of hole not exc.50mm , thickness of wall 70cm to 80cm and place 3" PVC Pipe of wall width for entry of suction and discharge copper and drain pipe pipes of AC indoor unit and making good disturbed surfaces with cement mortar and finally finished with plaster of paris and painted the distrubed surfaces with existing type of paint and tint complete all as specified and directed by Engineer Incharge.
M/S JEELANI ELECTRICALS
AMW Construction and developers
M/S, J.K.CONSTRUCTION
Mehta and Co.
agarwal and company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .