PROJECT ENGINEER MPPHIDCL BALAGHAT
OFFICE MPPHIDCL POLICE LINE BALAGHAT
Under External Electification work 25 KV Electrical Transformer and line work for the Voltage Problem located in CRPF barracks at outpost saletekri Distt. Balaghat.
2021_MPPHC_167388_1
08 / 2021-22
Open Tender
Electrical Works
Item Rate
30 days
Balaghat
AS PER NIT
3 documents required · 3 mandatory
₹2,000
₹8,800
4 Feb 2022
12 Nov 2021
30 Nov 2021
12 Nov 2021
26 Nov 2021
12 Nov 2021
Amount
Supplying and erection single length support for 33KV/11KV line complete with aligning and keeping it in truly vertical position, including digging pit of required size in all type of soil/rocks, filling with 1:3:6 cement concrete of0.50 mtr. dia. around the pole up to ground level includingmuffing of 0.45 mtr. dia. from ground level to 0.45 mtr. high as per specifications with 20 cm. thick base foundation in1:4:8 cement concrete as required, refilling the pit withboulder and soil as required, including painting of pole withbitumen paint below GL and two coats of red oxide and two coats of aluminium paint or synthetic enamel paintas directed etc as per specification complete The depth of burying of pole shall be 1/6th of the length of pole.H beam 152x152mm or 150x150mm 37.1 Kg./M. weight , all work to be done as per MPKVVCL norms & specifications complete.
(B) 11 M.long
Supplying and erection of HT/LT over head line single length supports complete with aligning and keeping it in truly vertical position, including digging pit of required size in all type of soil/rocks filling with 1:3:6 cement concrete of 0.60 mtr. dia. around the pole up to ground level including muffing of 0.45 mtr. dia. from ground level to 0.45 mtr. high as per specifications with 20 cm. thick base foundation in 1:4:8 cement concrete as required refilling the pit with boulder and soil as required, including painting of pole with bitumen paint below GL and two coats of red oxide and two coats of aluminium paint or synthetic enamel paint above GL as directed complete as per specifications. The depth of burying of pole shall be 1/6th of the length of pole. all work to be done as per MPKVVCL norms & specifications complete.
(i) R.S. Joist 9.3 Metre 175X85MM 19.3 KG/Mtr
STAY SET Supplying and erection of GI/MS stay set complete with stay rod, anchor plate of size 300x300x5mm, thimble, stay clamp, turn buckle, bow tightener etc. with stay wire, strain insulator, nut bolts as per specifications including excavation in all type of soil/ rocks and foundation in cement concrete 1:3:6 of required size and other necessary materials complete as required as per specifications
(ii) GI Stay Rod 16mm dia (Painted) 1.8 m long with 7/3.15mm stay wire for LT line.
11 KV DISC POLYMER L.ROAD TYPE T& C INSULATOR Supplying and fixing polymer type 11KV/33KV HT Disc (strain) insulator of approved make on existing pole or bracket with GI hardware and other necessary materials complete as required.
(i) 11 KV (45KN) Disc Polymer L.Rod type T&C Insulator with 11 KV Composite Polymer Strain set with hard ware suitable for panther conductor w L.ROD type T&C Insulator complete. all work to be done as per MPKVVCL norms & specifications complete.
POLYMER PIN INSULATOR Supplying and fixing polymer type 11KV / 33KV pin insulator with GI pin, of approved make on existing pole or bracket with other necessary materials complete as required. all work to be done as per MPKVVCL norms & specifications complete.
(i) 11 KV 5 KN PIN Composite Polymer Insulator
Supplying and drawing ACSR/AAAC conductor of approved make with stringing, making off complete with binding at existing insulator, jointing , jumpering, billing off connecting, making 'D' loops connections etc. complete and clearing of obstacles (if any) as specified and directed. all work to be done as per MPKVVCL norms & specifications complete.
AAAC Conductor (0.075 sq. inch ) 80 sqmm Al. or Equivalent (Rabbit)
AAAC Conductor (0.05 sq. inch ) 55 sqmm Al. or Equivalent (Rabbit)
EARTHING COIL OF 115 TURNS OF 50 MM DIA.2.5 MTR.LEAD OF 4.0 MM G.I.WIRE Providing and fixing earthing arrangement for HT/LT poles with 8SWG GI lead of 115 turns of 50 mm dia. connection with pole / cross arm / control junction box on pole with 4 mm dia. GI lead through 20 mm dia A class GI protection pipe of 2.5 m length duly bend, packing of charcoal powder and salt as per specifications including excavation of pit in all type of soil / rock, refilling of pit by black cotton soil etc. complete. all work to be done as per MPKVVCL norms & specifications complete.
ANTI CLIMBING DEVICE BARBED WIRE Supplying and fixing 2 ply 12 gauge barbed wire around the existing HT/LT electric pole for safety measures as per IE rules including all stapples and all other necessary materials complete as required as per specifications. all work to be done as per MPKVVCL norms & specifications complete.
DANGER BOARD ENAMELED Providing and fixing enamelled danger caution plate/board on existing electric poles or wherever required of size 250x200 mm, made of 1.6mm thick mild steel sheet and vitreous enamelled white, with latest, figures and the conventional skull and cross-bones in signal red colour (as per IS-5-1978 with latest amendment) on the front side. The rear side of the plate shall also be enamelled. The corner of the plate shall be rounded off with required material such as screws, wires clamps, nut bolts etc. complete. all work to be done as per MPKVVCL norms & specifications complete.
Supply & fixing fencing of chain link mesh 100 x 100 mm, 12 SWG GI wire for for D.P. structure electric sub-station switch yard including single post of angle iron size 50x50x5mm, 2.5 mt long should be provided upto 2.00 mt. apart or as required. The panel frame with required angle iron/ flat iron members/cross members includin mesh welded in frame panel shall be erected between the posts. The angle iron post shall be erected in cement concrete M15 (1:2:4) (20 mm graded metal) foundation, including excavation of pit and refilling the same. The fencing shall be provided with one entrance gate including locking arrangement as required as per specification. The height of fencing shall be 2 mt. above ground level. Fencing shall be painted with required shade, Double Gate (2 Nos. 2.5’X5’) of MS angle (50X50X6)mm. bracing of 25X5 mm flat with mesh & locking arrangement (SOR It No-42.74/Pag No-177)
Supplying and fixing of Angle/ channel/flat iron, V cross Arms reinforcement of RSJ jolt/ flat iron fittings for overhead lines and poles such as cross arms/ bracket/ clamps/ stiffness for poles etc. all required steel work including' cutting to size making proper shapes drilling scan welding etc. including nuts & bolts plan & spring wisher and other necessary material including one coat of red oxide and two coat of aluminum paint etc. as required. all work to be done as per MPKVVCL norms & specifications complete.
Supplying, installing, testing and commissioning of 11/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification, hand operated off load tap changer switch above 100 KVA, oil conservator with drain valve, plug 63 KV and above. Energy efficiency level -2,Aluminium wound . all work to be done as per MPKVVCL norms & specifications complete.
DTR 11/0.4 KV BIS LEVEL-II CONVENTIONAL 25 KVA
Providing and fixing outdoor type pole mounting weather, dust and vermin proof L.T. distribution box made of 14/16 gauge, M.S. sheet with clamping arrangements, lockable hinged door duly painted on all sides with red oxide antirust and corrosion treatment two coats of synthetic enamel paints of approved make and shade, consisting of following fittings. L.T. Distribution box suitable for 63/100/200/315 KVA.transformer with required Amp MCCB/Isolator on incoming side and PF HRC units on outgoing side. all work to be done as per MPKVVCL norms & specifications complete. For 25 KVA Transformer a) 200 Amps 35 KA breaking capacity TP MCCB with neutral link for incoming - 1No. b) 4 strip aluminium bus bar 225Amps supported on epoxy insulators - 1 Set c) 160/200 Amps, 415Volts DMC cutout with base for outgoing feeder with 160/200 amp HRC - 9 Nos. d) GI earth terminals- 2 Nos. e) 6 Lever Godrej Padlock with 3 keys - 1 No. f) Light point with switch and lamp holder with lamp - 1 No.
Distribution box complete as above (a to F) as per MPKVVCL norms & specifications complete.
Commissioning of D P structure over existing support with panting in an approved manner consisting of following :- all work to be done as per MPKVVCL norms & specifications complete. (A) D. C. cross arm with clamp, nuts & bolts (100 x 50 mm only ) - 1 set (B) 11 KV D. O. fuse unit, lightings arrangement and AB swich mounting channel with nuts and bolts (75 x 40 mm channel) of require - 1 set (C) 11 KV Polymer AB swich as required ( set of 3 Nos.) - 1 set (D) Transformer mounting cross arms / channels with clamps nuts and bolts (100 x 50 mm channel ) - 1 set (E) 11KV Polymer Do fuse unit ( set of 3 no.) - 1 set (F) Transformer clamping set (50x50x6 mm angle ) with nuts and bolts etc. complete -1 set (G) Transformer belting set (50x50x6 mm angle) with nuts and bolts etc. complete -1 set (H) 11 kv polymer lightning arrestor ( 9 kv gapless type ( 5 kA ) for DTR ) ( set of 3 No.) - 1 set
(I) supplying , fixing, testing and connecting of complete earling set of 7 No. as per MPMKVVC.Ltd. circular No DS CO M/EZ/ WS/1516/DT 17-03-2008 and approved dwring for transformer sub - station including all materials GI Strips, GI wires, Charcoal power salt excavation of pits in all types of soils/rocks etc. as required complete .( 1 set of 7 Nos.) -1 set (J) Distribution panel mounting channel and clamp with nuts & bolts etc. (75 x 40 mm channel ) 1 – set (K) Supplying , fixing, testing and Commissioning of DTR Meter LT. 3 phase 4 wire 3X240 volts I 3 A. LTCT operated 3 phase 4 wire 3x63, 5 volts , LB = 5 amps lmax 10 amp trivector meter glass of accuracy 0.5s DLMS complaint category a meter along with GSM ( GPRS compactable ) modems with box i/c all accessories and formalities as per MPMKVVCL as required. or 3P 4w - 5A LTCT class 5s DLMS compliant type c. rs - 232. Port box MRI LTCT 100/5A i/c meter box with TTB etc as requiredas per MP SEB latest Specification. (L) SF & T and HT tape for covering LT bushing i/c windings and blower hitting complete minimum 30 meter or as required.
D.P. Structure Complete as above (A to L)
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 15541964,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connection through lugs by cramping method glands etc as required as per specification. all work to be done as per MPKVVCL norms & specifications complete. (A) Supplying laying testing and commissioning.UnArmoured single core XLPE insulated aluminum conductor cable. all work to be done as per MPKVVCL norms & specifications complete.
(a) 50 sq mm.
b) 70 Sqmm
(c) AB cable (3X50+1X16+1X35)sqmm 1100 Volts. with insulated messenger wire.
S/F and testing Junction box spring Loaded complete all work to be done as per MPKVVCL norms & specifications complete.
b) Spring loaded busbar system suitable for 1-incoming 3 outgoing 3 phase circuit
Jointing slives Suitable for Al AAAC Conductor all work to be done as per MPKVVCL norms & specifications complete.
NOTE - 1) The contractor is responsible for approval of Transformer & Sub Station, VCB, H.T./L.T. lines/testing of all Material and meter from competent authority of Electrical Inspector and energisation/ commissioning of sub-station H.T./L.T.lineand necessary shut down from MPPKVVCL. No extra payment will be done for this job. 2) Quantities/items may increase/decrease as per site conditions. 3) Ready to carryout maintenance work if failure of any equipment/Items within 5 year period from the date of handing over.
NEERAJ KUMAR JAIN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .