| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC | ₹26.1 L Quoted ₹26.5 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹27.7 L+₹1.2 L (4.55%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | ₹27.7 L+₹1.2 L (4.55%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹28.7 L+₹2.2 L (8.38%)Rejected-Finance | ₹28.7 L+₹2.2 L (8.38%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹34.7 L+₹8.2 L (31.0%)Rejected-Finance | ₹34.7 L+₹8.2 L (31.0%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹38.6 L+₹12.1 L (45.7%)Rejected-Finance | ₹38.6 L+₹12.1 L (45.7%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 May 2025, 5:00 pmClosed
GE (SB) KARWAR
GE (SB) KARWAR
REPAIRS / MAINTENANCE OF SEWAGE TREATEMENT PLANT (STP-1) INCLUDING SLPH 1 AND 2 AT ARGA AND REPAIR AND MAINTENANCE OF ETP-1 AT NSRY,ETP-II AT CNTW COMPLEX AT NAVAL BASE UNDER GE(SB) KARWAR
2025_MES_703157_1
8322/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (SB) KARWAR
₹90,000
Yes
31 Jul 2025
29 Mar 2025
5 May 2025
29 Mar 2025
2 May 2025
16 Apr 2025
29 Mar 2025 - 12 Apr 2025
Amount
M&L for opening of sand media filter gate of STPs of size 1.2 meter dia 1.5 meter height after closing all inlet and outlet valves and removing old dirty sand media with old nut & bolt/gasket/washer from filter chamber and cleaning complete chamber, drying, preparation of surface and applying two coats of synthetic enamel paint using spray gun and filling of new sand media as per standard procedure, fixing new old nut & bolt/gasket/washer etc complete all as specified and as directed. Note :- Filter media required shall be measured and paid as "Supply only"
Supply only granular fine pebbles of size 40mm to 3mm match to existing size and shape suitable for filter media of rapid sand water filters free from all types of salts, alkaline materials, minerals, silts, impurities etc complete all as specified and as directed.
Supply only quartz/silica, sand all as per existing suitable for dual filter complete all as specified and as directed.
M&L for dismantling, transportation, servicing , refixing and testing of air compressor of capacity 60 HP (Air Blower ) at STP, Make : KAY through qualified service engineer/OEM including removal of old oil & filling of new oil upto required level in sump, replacement of gasket, bearings etc incl replacement of the old unsv filter assembly with the new filter assembly, minimising the vibration of the blower, rectifying the air leakages if any persists in the system by rectifying the defects, making the allignment of the blower assembly with the motor alongwith V belt for allignement between bower and motor pulleys all as specified and directed. Note: a) The oil for blower is to be measured as and paid seperately. b) All the minor parts required for the reapir to blower assebly, filter assy, pulleys and allignment between the blower and motor is incl in the above quoted rate.
All Discription as per item no 4.00 here in before, but air compressor (Air blower) of capacity 12.5 HP Complete all as specified.
Taking down old unserviceable pressure gauges and supply and fix pressure guages suitable for 200 mm dia sewage pipe, pressure having static pressure 40kg/sqcm, range 0-10 kg/sqcm, class 1% , made out of SS 316 type material with syphons and components/fittings including testing at STP complete all as specified and as directed.
Taking down old unserviceable pressure gauges and supply and fix pressure guages suitable for 100 mm or 150 mm dia sewage pipe, pressure having static pressure 40kg/sqcm, range 0-10 kg/sqcm, class 1% , made out of SS 316 type material with syphons and components/fittings including testing at STP complete all as specified and as directed.
Taking down old unserviceable pressure gauges and supply and fix pressure guages suitable for 80 mm dia Sewage pipe, pressure having range 0-2.5 kg/sqcm, class 1% made out of SS 316 type material with syphons and components/fittings including testing at STP complete all as specified and as directed.
M&L for Opening, Repairs and overhauling of existing Sluice/Gate Valve dia of 200 mm to 400 mm at main receiving chamber/ aeration tank at STPs and SLPH 1-&2 including replacement of SS lock nuts, repairs to spindle and wheel, washers, rings SS nuts and bolts, gaskets including removing and refitting metalising on sewage lines including one coat of primer and two coats of epoxy paint complete all as specified and as directed.
All as per item No 09.00 here in before, but of size 100 mm to 150 mm complete all as specified and as directed.
Taking out old damage sluice valve and supply and fix in repair CI Sluice valve class PN 1.6 of 250 mm dual flanged type including brass lock nuts, spindle and wheel, washers, rings SS Nuts and bolts, gaskets including fixing on sewage lines including one coat of primer and two coate of epoxy paint at STP complete all as specified and as direted.
All as per item No 11.00 here in before, but of size 200 mm complete all as specified and as directed.
All as per item No 11.00 here in before, but of size 150 mm complete all as specified and as directed.
All as per item No 11.00 here in before, but of size 100 mm complete all as specified and as directed.
Taking down old unserviceable CI butter fly valve of any make and size and supply and fixing of new CI Butter fly valve slim seal design with nitrile rubber lined seat with gear operated (p10) of size 200 mm conforming to IS 13095, at STP complete all as specified and as directed.
Taking down old unserviceable CI butter fly valve of any make and size and supply and fixing of new CI Butter fly valve slim seal design with nitrile rubber lined seat with clutch lever (p10) of size 150 mm conforming to IS 13095, at STP complete all as specified and as directed.
All as per item No 16 here in before, but of size 100 mm complete all as specified and as directed.
Taking out old damage Non return valve and supply and fix in repair Non return valve (NRV) of 200 mm dual flanged type conforming to IS 1538, including brass lock nuts, washers, rings SS Nuts and bolts, gaskets including fixing on sewage lines including one coat of primer and two coat of epoxy paint, at STP complete all as specified and as direted.
All as per item No 18 here in before, but of size 150 mm complete all as specified and as directed.
All as per item No 18 here in before, but of size 100 mm complete all as specified and as directed.
M&L for Opening, Repairs and overhauling of existing NR Valve dia of 100 mm to 200 mm at main receiving chamber/ aeration tank at STPs and SLPH 1-&2 including replacement of SS lock nuts, washers, rings SS nuts and bolts, gaskets including removing and refitting metalising on sewage lines including one coat of primer and two coats of epoxy paint complete all as specified and as directed.
All as per item No 21.00 here in before, but dia of existing NR Valve having 250 mm to 400 mm Complete all as specified.
Supply and fix in repair V-belt of suitable size alongwith making correct allignment with the existing pulleys of the blower motor and pumps for Air Blower of capacity 60 HP &12.5 HP all as specified and directed.
Supply and topping Gear oil of high quality having grade HP-90 all as specified and directed.
Supply and topping lubricating oil suitable for lubrication of the beraing housing assembly of non clog centifugal seage pumps of different capacities installed at STPs having grade of 20/40W all as specified and directed.
Supply and fix in repairs bearing No 6308 2Z suitable for pumpset at STP complete all as specified and as directed.
Supply and fix in repairs bearing No 6208 2Z suitable for pumpset at STP complete all as specified and as directed.
Supply and fix in repairs bearing No. 6306 2Z /6305 2Z for pumps at STP complete all as specified and as directed.
Supply and fix in repairs bearing No. 6205 2Z /6206 2Z for pumps at STP complete all as specified and as directed.
Supply and fix in repairs bearing No 6310 2Z for pumps at STP complete all as specified and as directed.
S&F in repair single phase preventer relay having system supply voltage 415 V AC Three phase +/- 10%, all as specified and as directed.
M&L for taking out the electric motor of capacity 1HP to 3 HP of mono block pumping set /centrifugal pumps/Air compressor of any make at STP, strip opening the motor, cutting/removing the existing burnt winding and rewinding using super enamelled copper wire of suitable gauge to match with the existing winding with same no of turns, including replacing sleeves, cotton taps etc, varnishing the winding by keeping in hot oven for drying to attain required insulation resistance & replacing ball bearing, re-assembling the motor and refixing the same in original position, testing the motor for min of 08 Hrs continuous running including testing of the winding resistance etc complete all as specified and as directed. Note:- a) The above quoted rate includes the dismantling of the motor from the compressor assembly and refixing the same after carrying out the requisite repairs/rectifications all as specified and directed.
All as per item No-32.00 here in before, but of capacity 5 HP all as specified and directed.
All as per item No-32.00 here in before, but of capacity 7.5 HP all as specified and directed.
All as per item No-32.00 here in before, but of capacity 12.5 HP all as specified and directed.
All as per item No-32.00 here in before, but of capacity 50 HP all as specified and directed.
All as per item No-32.00 here in before, but of capacity 60 HP all as specified and directed.
Taking down old unsv and supply and fix in repair wather proof push button metal enclousers sheet including ammeter range of 0-600 A, current ratio 100/5 A, with emergency stop and start push button, IP 65 as per IS 13947, fixing as per existing suitable for 60 HP air blower at STPs including connection and testing complete all as specified and as directed.
All as per item No-38.00 here in before, but ammeter range of 0-120, current ratio 20/1, suitable for 7.5 HP capacity centrifugal pumps all as specified and directed.
All as per item No-38.00 here in before, but ammeter range of 0-180, current ratio 30/1, suitable for 12.5 HP capacity air blower all as specified and directed.
All as per item No-38.00 here in before, but ammeter range of 0- 450, current ratio 75/5, suitable for 50 HP capacity centrifugal pumps all as specified and directed.
Taking down old unsv and supply and fix in repair wather proof push button metal enclouser sheet with emergency stop and start push button, IP 65 as per IS 13947 fixing as per existing suitable for 1 HP to 7.5 HP pumps at STPs including connection and testing complete all as specified and as directed.
M&L for surface cleaning of all the below mentioned items and scrapping the old paint from the surface and one coat of red oxide / primer after cleaning including preparation of old steel surface exceeding 10 cm width or girth and painting with two coat of synthetic enamel paint on machineries/equipments/filters/motors /pumps /compressors/ladders/walkovers/ pipelines/ cable trays, panels and any other parts connected to STP-1/ SLPH-1 & 2 with paint of approved colour using spray gun complete all as specified and directed.
Supply & Fixing Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, at STP/SLPH complete all as specified and as directed.
Supplying and laying in replacement of old unsv synthetic Rubber insulated mats 3 mm thick for voltage upto 3300 volt for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and as directed.
Supply and fix in repair rubber star coupling suitable for male female lovejoy coupling of centrifugal/monoblock pump set of capactiy 3 HP to 50 HP as per site required at STP complete all as specified and as directed.
Taking out existing unsv and supply, fixing and testing in replacement new electromagnetic flow meter as per model 151 MFM WR4200NO1502D1161428P having sensor size 150 MM having sensor size 150 MM, accuracy class & display + 0.5% of measured flow with rated pressure 10 Kg/Sqcm, sensor factor 1.1930, electrode made out of SS 316 materials, including the nuts, bolts, indicater convertor : remote, field mounted, stabilizer, cable, sensor, sensor lining etc and refixing the same in original position for STP-1, complete all as specified and as directed.
M&L for taking out the sewage submersible pump of 150 HP of capacity of any make from SLPH-1 at arga including cutting/removing the existing burnt winding and rewinding the same using super enameled copper wire of suitable gauge to match with the existing winding including replacing sleeves, cotton taps etc, varnishing the winding by keeping in hot oven for drying to attain required resistance & replacing ball bearing, re-assembling the motor and refixing the same in original position, testing etc complete all as specified and as directed.
M&L for taking out the sewage submersable pump capacity upto 30 HP, 200 cum per hour make kishor pumps pvt ltd from SLPH-2 at Arga including cutting/removing the existing burnt winding and rewinding the same using super enameled copper wire of suitable gauge to match with the existing winding including replacing sleeves, cotton taps etc, varnishing the winding by keeping in hot oven for drying to attain required resistance & replacing ball bearing, re-assembling the motor and refixing the same in original position, testing etc complete all as specified and as directed.
Taking down old existing DI pipes and Supply, laying DI pipes Class “K-9'' heavy grade, flanged end with all fittings and joints laid in floors/ trench or fixed to walls and ceilings etc. in sewage treatment plant/ sump of size 300 mm complete all as specified and as directed.
Taking down old existing DI pipes and Supply, laying DI pipes Class “K-9'' heavy grade, flanged end with all fittings and joints laid in floors/ trench or fixed to walls and ceilings etc. in sewage treatment plant/ sump of size 250 mm complete all as specified and as directed.
Taking down old existing DI pipes and Supply, laying DI pipes Class “K-9'' heavy grade, flanged end with all fittings and joints laid in floors/ trench or fixed to walls and ceilings etc. in sewage treatment plant/ sump of size 200 mm complete all as specified and as directed.
Taking down old existing DI pipes and Supply, laying DI pipes Class “K-9'' heavy grade, flanged end with all fittings and joints laid in floors/ trench or fixed to walls and ceilings etc. in sewage treatment plant/ sump of size 150 mm complete all as specified and as directed.
Taking down old existing DI pipes and Supply, laying DI pipes Class “K-9'' heavy grade, flanged end with all fittings and joints laid in floors/ trench or fixed to walls and ceilings etc. in sewage treatment plant/ sump of size 100 mm complete all as specified and as directed.
M&L for repair to the Gear assembly of the clarifier tank including replacement of the minor parts if required, i.e. Chain assembly, gears of different sizes, dismantling of motor and shaft, reconditioning of socket, replacement of bearings, coupling joints, repair to the shaft of the gear motor assembly, making the allignment of the motor shaft and gear, refixing the motor with the gear assembly at STP complete all as specified and directed.
Taking down old unserviceable and Supply and fixing cast iron love joy coupling (male-female) as per existing model from seconadry tank pump motor unit 3 HP or 5 HP by changing of motor position, including gas cutting welding, refitting and aligning of the same at STP complete all as specified and as directed.
Taking down old unserviceable and Supply and fixing cast iron love joy coupling (male-female) as per existing model from equilization tank pump motor unit 7.5HP or 12.5 HP by changing of motor position, including gas cutting welding, refitting and aligning of the same at STP complete all as specified and as directed.
Taking down old unserviceable and Supply and fixing cast iron love joy coupling (male-female) as per existing model for pump motor( back feeding pump) unit of 50 HP by changing of motor position, including gas cutting welding, refitting and aligning of the same at STP complete all as specified and as directed.
M&L for Disconnecting and taking out of Submersible raw sewage Lift pump 30 HP, from SLPH-1, vertical type for general overhauling / inspection of impeller, shaft all bearings and sleeves, and re-installation of Pump after replacing all sleaves, bearings,seals and with SS nut bolts, metalising the shafts and re threading bottom plate by lathe work including body repairs, welding works and complete testing all as specified and as directed. Note: a) All the minor items like impellers, base plate for the pumps, shaft of the pumps are included in the above quoted rate b) The transportation charges for the item above is also included in the above quoted rate.
M&L for dismantling and taking out of Submersible raw sewage Lift pump 150 HP, from SLPH-02 of STP-1 vertical mounted for general overhauling/inspection of impeller, shaft all bearings and sleaves, oil/mechanical seals, terminal blocks and water sealing , and refitting of Pump after replacing all sleaves, bearings, seals and with SS nut bolts, metalising the shafts and re threading bottom plate by lathe work including body repairs, welding works and complete testing all as specified and as directed. Note: a) All the minor items like impellers, base plate for the pumps, shaft of the pumps are included in the above quoted rate. b) The transporation charges for the item above is also included in the above quoted rate.
M&L for servicing of LT panel of capacity upto 1000 Amps suitable for AC supply including MCCB/MCB/STARTER by strip opening the doors of the panel and carrying out the cleaning of the panels with CRC spray and tightening the loose connections of the panel including repalcement of the cable glands wherever required, replacement of the old teared/ unsv insulation from the bus bar, checking the IR value before fixing the LT sleeve and refixing the heat shrinkable insulating tape sleeve suitable for 1.1 kv busbar not less than 3mm thick having dielectric strength not less than 1.1kv/mm and LT insulation tape for CT/ PT connection complete with checking the IR value before testing and commissioning the bus bar all as specified, rectifying the internal wiring of the panel alongwith control wiring between, MCCB, CT, PT, Earth fault relay, over current relay and digital multi function meter, complete all as specified and directede by Engr - in- charge. Note:- (a) The above quoted rate includes the cost of the insulators, nuts, bolts, washers and cable gland required for the repair of the panel
M&L for Cleaning of Equalization tank at STP-I by pumping out raw sewage, removing the sludge settled at the bottom, cleaning thoroughly with wire brush, finally cleaning with dilute solution of sodium hypochlorite & fresh water including writing letters on the tank with synthetic enamel paint as "TANK CLEANED ON ------(DATE) AND DUE ON ---DATE with 10 cm high stencil cut English letter all as specified and directed.
All as per item No 62.00 herein before, but for Aeration Tank at STP-I Complete all as specified.
All as per item No 62.00 herein before, but for secondry clarifire tank at STP -I Complete all as specified.
All as per item No 62.00 herein before, but for Clorine tank at STP-I Complete all as specified.
All as per item No 62.00 herein before, but for Sludge Settling tank at STP Map Complete all as specified.
All as per item No 62.00 herein before, but for SLPH-I at NSRY Complete all as specified.
All as per item No 62.00 herein before, but for SLPH-II at Arga Complete all as specified.
Taking out old damage Casing assembly and Supply and fix in replacement of Cast iron Casing assembly, suitable for 50 HP capacity pumps including removing and refixing of impeller, shaft, bearings, sleaves, seals with SS nut bolts, and re installation of Pump, metalising the shafts including welding works installed at STPs complete accessories all as specified and directed by Engr-in-charge.
All as per item No 69 herein before, but suitable for 7.5 HP/12.5 HP capacity pumps as per site required Complete all as specified.
All as per item No 69 herein before, but suitable for 3 HP/5 HP capacity pumps as per site required.
Supply and fix in repair roatary type door handle suitable for LT Panel at STPs and SLPH complete all as specified and as directed.
Supply and fix in repair O/L reset push button/ stop push button as per colour coding combination suitable for LT Panel at STPs and SLPH complete all as specified and as directed.
Supply and fixing in repairs Multicourse Round PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 motors to panel inside SLPH and STPs including excavation of hard brick layer and making necessary clamping , including provision for new lugs all as specified and directed of following sizes :-
(a) 2.5 Sqmm and 3/4 core as per site required.
(b) 10 Sqmm and 4 core
Taking out old damage parts and supply and fix Bends, Tapers, Tee pieces, (single & double branch) any, type and angle/radius and straight connecting pieces but all ends flanged suitable for upto 300 mm DI pipes including nuts/bolts, gasket complete all as specified and directed.
Supply and using calcium hypchlorite (stable bleaching powder/high strength bleaching powder) appearance should be dry, free flowing and free from lumps, should not include substances beyond acceptable limit as given in IS 105000(2012) in treated and disinfected water, available chlorine should be 65% stability loss of chloride on basis of available chloride max 1/15 particle size (passing throung 1.70 mm IS sleeve min 99.5% water insoluble matter 6%, calcium hydroxide maz 4%, sodium chloride max 15% in 20-45 Kg plastic drum packing for STPs, complete all as specifiied and directed by Engr in charge. Note:- The contractor shall submit alongwith supply of material purchase vouchers test certificate for chemical composition and its expiry date etc and other relevant documents supply of chemical shall not be accepted without production of these documents and no payment released.
Supply and fix in repair MCCB 4 Pole, 415 V, Adjustable type, 100 Amp/160 Amps as per site required with breaking capacity 36 KA including commissioning complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair MCCB 4 Pole, 415 V, Adjustable type, 400 Amps, with breaking capacity 36 KA including commissioning complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair MCCB 4 Pole, 415 V, 630 Amps, Cat A, with breaking capacity 36 KA including commissioning complete all as specified and as directed by Engr-in-charge.
Supply and fixing Cable jointing kit end termination for 415 Volts grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 - 240 sqmm complete all as specified and directed.
M&L for replacement of old unsv GI pipe of dia 100mm of medium grade suitable for aeration of the sewage water over the aeration tank along with fabrication of the nozzles as per existing size with the GI tubing be threading and connecting the nozzles, interconnecting the GI tubing inside the aeration tank, alongwith connecting the GI tubing with the outlet of the air blower assembly and testing the GI tubing during operation of the blower assembly complete all as specified and directed.
Taking out old damge and Supply and fixing in replacement clarifier tank MS impeller/ hollow shaft of made out of MS pipe of size 300 to 450mm as suitable at site including replacement of the centre bearing assembly, scraper arm with adjustable holding bracket, scraper blade with neoprene rubber squeeze, tie rod 20 mm dia, sludge well scraper, bottom guide bush including provision of under water fastener SS 304 and painting complete clarifier assembly above water using epoxy paint and and water assembly using coaltar epoxy paint complete all fabrication work as per site requirement complete all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
Taking out old unsv LT underground cable including connected items complete all as specified and directed.
Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded,armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm 4 core, conforming to IS laid in trenches /wall /floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed.
All as per item No 85.00 herein before, but 240 Sqmm and 3.5 core Complete all as specified.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and directed.
Returning, filling in soil including spreading leveling, watering and well ramming in layers not exceeding 25cm thick all as specified and directed.
Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Supply and spread dry river sand in trenches for cable cushioning all as specified in clause 19.75 of SSR Part-I. Note:- Punned thickness of sand only will be measured & paid
Supply and laying un-reinforced pre-cast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
M&L for cleaning including preparation of old steel surface exceeding 10 cm width or girth and painting with one coat of primer and two coat of synthetic enamel paint on machineries /equipments /filters/ motors / pumps/ compressors / ladders/ walkovers/ pipelines/ cable trays and any other parts connected to ETP-01 at NSRY with paint of approved colour using spray gun complete all as specified and directed.
M&L for cleaning including preparation of old steel surface exceeding 10 cm width or girth and painting with one coat of primer and two coat of synthetic enamel paint on machineries /equipments /filters /motors /pumps / compressors / ladders/ walkovers/ pipelines/ cable trays and any other parts connected to ETP-02 at CNTW Complex with paint of approved colour using spray gun complete all as specified and directed.
S&F in repairs HRC fuse links cylindrical type 2-32 amps size 14 x 51 suitable for type FN 32 / FNX 32 / S-D-F & for HCO 32 fuse base all as specified and as directed.
S & F in repairs HRC fuse links cylindrical type 63 amps size 14 x 51 suitable for type FN 63 / FNX 63 S-D-F & for HC 63 fuse base all as specified and as directed.
S&F in repairs HRC fuse links DIN type 125 amps size 00 suitable for type FA-C 100 & for HB 160 Fuse base all as specified and as directed.
S&F in repairs HRC fuse links DIN type 200 amps size 00 Suitable for T ype FN 200/FNX 200 S-D-F & for HB 250 Fuse base all as specified and as directed.
M&L for taking out treated effluent pump and motor having capacity 10 HP /7.5 KW, Cap 76.3 Cum/hr, RPM - 2890/2918, Make of Grandfoss, from ETP-1 at NSRY and rewinding with supper enameled copper wire of existing gauge, number of turns, insulating and heat varnishing, greasing complete including replacement of bushes, bearing check nut, and other required parts and applying two coats of synthetic enamel paint over a coat of red oxide primer to external surface of motor and testing complete all as specified and as directed.
All discreption as per item no 98.00 herein above, but Surface Aeration motor having capacity 7.5 HP/5.5 KW, RPM 1445 Make : Bharat Bijlee of Aeration tank at ETP-1 at NSRY .
All discreption as per item no 98.00 herein above, but filter back wash pump and motor having capacity of 5 HP/3.0 KW , cap 46.1 Cum/hr, RPM - 3400/3480 of Make : Grundfos from ETP-1 at NSRY.
All discreption as per item no 98.00 herein above, but 3 phase induction motor of Coalscer Column feed pump ( filter feed pump) capacity 3 HP/2.2 KW , Cap 40.5 Cum/hr, RPM- 2865/2900, head 13.1 mtr of Make : Grundfos, from ETP-1 at NSRY.
All discreption as per item no 98.00 herein above, but 3 Phase Induction motor of Sludge transfer pumps having capacity 2 HP/1.1 KW, RPM- 2820 of existing make from ETP-1 at NSRY.
All discreption as per item no 98.00 herein above, but 3 Phase induction motor of Filter feed pump having capacity 2 HP of Make- Teco Elec and Mech Pvt Ltd from ETP-1 at NSRY.
Taking out Belt type oil skimmer with motor of 0.18 KW RPM 1320/1630 of Make - Bonfyglioli from ETPs and refixing the same after rewinding with supper enameled copper wire of existing gauge, number of turns, insulating and heat varnishing, greasing complete including replacement of bushes, bearing check nut, and other required parts and applying two coats of synthetic enamel paint over a coat of primer to external surface of motor and testing complete all as specified and as directed.
M&L for taking out old unsv/damage HDPE Pipe lines of any dia layed on walls/ floor/ Ceiling and laying in Trenches including all joints complete all as specified and as directed.
M&L in repairs HDPE Pipes, Pressure rating 10kg/cm2 having dia of 150 mm as per site requirement including all joints, bends, elbows, Y/T connection, flanges, SS clamps, hanger bolts, reducers for effluent water pumping pipe lines layed on walls/ floor/ Ceiling and laying in trenches in sand or hard PCC complete all as specified and as directed.
All discreption as per item no 106.00 herein above, but HDPE Pipes having Pressure rating 10kg/cm2 having dia of 100 mm as per site requirement.
All discreption as per item no 106.00 herein above, but HDPE Pipes having Pressure rating 10kg/cm2 having dia of 75 mm as per site requirement.
Taking down old unserviceable valve and supply and fix new flange end type Ball valves suitable for pipe lines of 10kg/cm2 of size 50-75 mm complete all as specified and as directed.
Taking down old unserviceable valve and supply and fix new butterfly valves dia of 80 mm or 100 mm, suitable for pipe lines of 10kg/cm2 of size 80mm or 100 mm complete all as specified and as directed.
Taking down old unserviceable valve and supply and fix new flange type HDPE Ball valves suitable for pipe lines of 10kg/cm2 of size 150 mm complete all as specified and as directed.
Supply and fixing of CI Gate valve flange type (P 1.6) of size 65-85 mm including taking out old unserviceable gate valve of any make and size complete all as specified and as directed.
M & L for Opening of sand media filter gate of ETP of size 1.2 meter dia 1.5 meter height after closing all inlet and outlet valves and removing old dirty sand media with old nut & bolt/gasket/washer from filter chamber and cleaning complete chamber, drying, preparation of surface and applying two coats of synthetic enamel paint using spray gun and filling of new sand media as per standard procedure, fixing new old nut & bolt/gasket/washer etc complete all as specified and as directed. Note :Filter media required shall be measured and paid as "Supply only".
M&L for cleaning of primary settling tank at ETP-1, by pumping out raw sewage, removing the sludge settled at the bottom, cleaning thoroughly with wire brush, finally cleaning with dilute solution of sodium hypochlorite & fresh water additives of required level applying one coat of bituminous paint including writing letters on the tank with synthetic enamel paint as "TANK CLEANED ON ------(DATE) AND DUE ON ---DATE with 10cm high stencil cut English letter complete all as specified and directed.
All as per item No 114.00, herein before, but for aeration tank at ETP-I.
All as per item No 114.00, herein before, but for Secondary settling tank at ETP-I
All as per item No 114.00, herein before, but for Clarifier water tank at ETP-I
All as per item No 114.00, herein before, but for treated effluent water tank at ETP-I
All as per item No 114.00, herein before, but for Equalization Tank at ETP-II
M & L for disconnecting and taking out sludge transfer pump/effluent pump/filter feed pumps of having capacity up to 76.3 cum/ hr, head -15.5-20s mtr, RPM - 1445 to 3480 make of Grudfosx/KSB/any make, from of ETPs for general overhauling/inspection of impeller, shaft all bearings and sleeves, and re-installation of Pump set after replacing all sleeves, bearings, seals and with SS nut bolts, metalising the shafts and re threading bottom plate by lathe work including body repairs, welding works and complete testing complete all as specified and as directed. Note: a) The above rated include the replacement of the impellers, seals, sleeves, nuts and bolts incl all the welding work required for the repair of the above pump.
M&L for Overhauling of Gear box and Motor assembly for clarifier tank at ETP-I (capacity of 315MLD) complete with tightening and aligning of chain assembly, reconditioning of socket, replacement of bearings, coupling joints and painting of the unit with two coats of epoxy black paint over a coat of anti corrosive primer paint complete all as directed.
M&L for replacement of Oleophilic polymer belt of length 4-6 meter(endless) & 300 mm width as per site required suitable for oil skimmer assembly suitable for ETPs of capacity of 315 MLD and 40 MLD complete all as specified and directed.
Supplying and laying in replacement of old unsv synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and as directed.
Supply and use of Dewatering Polyelectrolyte (DWPE) powder for treatment of effluent at ETP all as per report and directed by Engineer-in-Charge.
Supply and fixing in repairs Multicourse Round PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 motors to panel inside ETP including excavation of hard brick layer and making necessary clamping , including provision for new lugs all as specified and directed of following sizes :-
(a) 2.50 SQ. mm, 3/4 core as per site required.
(b) 6.00 SQ. mm, 3/4 core as per site required.
(c) 10.00 SQ. mm, 3/4 core as per site required.
M&l for taking down/out of Belt type oil skimmer with motor of 0.18 KW RPM 1320/1630 of Make :Bonfyglioli from ETPs including servicing / repairs of motors and pulleys and replacement of old Belt with new one same as per existing at site if required and replacement of old nuts, bolts, washers and all necessary repairs & testing for smooth functioning of Oil Belt skimmer all as specified and as directed. Note : Replacement of Belt shall be measured and paid separately.
Dismantling and taking out unserviceable and Supply, installation, testing and commissioning of 3 Phase, 415 volts star/delta or DOL as per site required, motor control panel outdoor type in replacement factory made out of 3.15 mm thick CRCA sheet and mounted on wall surface, IP-54 having locking arrangements, totally enclosed weather proof, powder coated over a coat of primer comprising of inbuilt by - pass contactor, transformer of suitable capacity, adjustable current limit, essential motor protection against overload single phasing, phase sequence reversal, abnormality in supply, unbalanced current, comprising of the following accessories complete all as specified and directed by Engr in charge : (i)TP MCB, 240/ 415 Volt, C 6 Amps - 04 Nos (ii) ON/OFF/Trip Indicator Lamp, 3PLBRL 240 type -08 Nos (iii) SOFT START/STOP Push button - 08 Nos (iv) DP MCB, 240/ 415 Volt, C 6 type with SP MCB 240/415, B20 - 01 Set (v) Selzer switches, AC15440v-1A- 04 Nos (vi) Complete wiring with suitable size copper cable, thimble etc.
(vii) Thermal overload relay (start & Off/Reset version), 3 pole, MN2 mounting type, trip class 10, voltage range 400-440v, biult in 2 NO + 1NC, Auto or Manual operated type -04 Nos (One number having current setting range 0.9 - 1.5 with fuse of 6A max, One number having current setting range 2.0 - 3.3 with fuse of 10 A max, Two number having current setting range 1.4 - 2.3 with fuse of 8 A max ) (viii) Contactor MNX 9 of suitable rating- 04 Nos. (ix) Pin based plastic glass body, 2 C/O -mac 12D-5 type, 8 channel relay -04 Note: (a)The control panel should be procured through CPRI approved manufacturer (b) The proper gland pacing for the cable entries to be provided.
Taking out old damage Casing assembly and Supply and fix in replacement of Casing assembly upto 3 HP capacity pump of any make & type, including removing and refixing of impeller, shaft, bearings, sleaves, seals with SS nut bolts, and re installation of Pump, metalising the shafts including welding works installed at ETPs complete accessories all as specified and directed by Engr-in-charge.
M & L for repair/replacement of Bar Screen suitable for tank size of dimensions 0.5MX 0.5M TDX20 MM including cleaning of tank , checking of allowable head loss suitable for Effluent treatment plant having capacity of 315 MLD capacity all as specified and directed by Engineer in charge.
Supply and fix in repair/replacement of control power transformer capacity of 1.5 KVA, 415 Volt including flexible copper cable connection suitable for LT Panel at ETPs complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair rotary type door handle suitable for fuse link capacity up 200 Amps of LT Panel at ETPs complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair O/L reset push button/ stop push button as per colour coding suitable for LT Panel at ETPs complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair Ammeter 0-30 range, MIC 96 type including complete connection all as specified and directed.
Supply and fix in repair Pressure gauge 0-4.2 Kg/Sqcm range type for ETPs including complete connection all as specified and directed.
Supply and fix in repair MCCB 3 Pole, 415 V, with Microprocessor release 400 Amps with breaking capacity 36 KA including suitable size of busbar /clamp, lugs with connection complete all as specified and as directed.
Supply and fix in repair MCCB 3 Pole, 415 V, with Microprocessor release 100 Amps with breaking capacity 36 KA including suitable size of busbar, lugs with connection complete all as specified and as directed.
Dismatling and taking out old unserviceable steel structures and M & L for Steel structural fabrication works fabricated structural steel sections, MS Pipe Line including nuts, bolts,washers, welding, bending cold or hot, drilling holes for bolts or making I beam as cross beam support for pumset and outlet pipe in any shape or size including one coat of red oxide and two coats of synthetic enamel black paint over a coat of anti corrosive primer coat complete all as specified and as directed.
Taking down old unsv and supply and fix in repair wather proof push button metal enclouser sheet with emergency stop and start push button, IP 65 as per IS 13947 fixing as per existing suitable for 1HP to 10HP pumps and motorgear assembly at ETPs including connection and testing complete all as specified and as directed.
M&L for servicing of LT panel of capacity upto 1000 Amps suitable for AC supply by strip opening the doors of the panel and carrying out the cleaning of the panels with CRC spray and tightening the loose connections of the panel including repalcement of the cable glands wherever required, replacement of the old teared/ unsv insulation from the bus bar,checking the IR value before fixing the LT sleeve and refixing the heat shrinkable insulating tape sleeve suitable for 1.1 kv busbar not less than 3mm thick having dielectric strength not less than 1.1kv/mm and LT insulation tape for CT/ PT connection complete and checking the IR value before testing and commissioning the bus bar all as specified, rectifying the internal wiring of the panel alongwith control wiring between, MCCB, CT, PT, Earth fault relay, over current relay and digital multi function meter, paintting of the LT panel inner and outer surface with the two coat of synthetic enammelled paint over a coat of red oxide primer all as specified and directede by Engr - in- charge. Note:- (a) The above quoted rate includes the cost of the insulators, nuts, bolts, washers and cable gland required for the repair of the panel
Taking out existing unsv and supply, fixing and testing in replacement new electromagnetic flow meter as per model 151 MFM WR4200NO1002D1161428P having Range 85 cum/hr, accuracy class & display + 0.5% of measured flow with rated pressure 10 Kg/Sqcm, sensor factor 1.7570, Output 4 to 20 mA, IP 68, electrode made out of SS 316 materials, including the nuts, bolts, indicater convertor : remote, field mounted, stabilizer, cable, sensor, sensor lining etc and refixing the same in original position for ETPs, complete all as specified and as directed.
ANKIT SHIP REPAIRERS AND SUPPLIERS (BID ID -3285685)
SRI GURUPRASAD INFRATECH (BID ID -3287536)
MNS ENGINEERING (BID ID -3287446)
M/S MANOJKUMAR M NAGARKATTE (BID ID -3286600)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .