| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.0 L+₹4.1 L (12.2%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹41.3 L+₹7.4 L (21.9%)Rejected-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹43.2 L+₹9.3 L (27.6%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-AOC Not Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
4 Aug 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY , MUDFORT, SECUNDERABAD-500003
Repair Renewal of Damaged water supply distributiuon line,REPAIRS to LT OH line , LT UG Cable , LT Panel, Street Lights and allied work and allied works at Unit 289, Unit 371,unit 729 AND certain other area under GE Utility Secunderabad
2020_MES_359436_1
GE(U)/SEC/TOKEN/23 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As per NIT
6 documents required · 6 mandatory
₹500
GE UTILITY SECUNDERABAD
₹80,000
Yes
12 Aug 2020
9 Jul 2020
6 Aug 2020
9 Jul 2020
4 Aug 2020
23 Jul 2020
Amount
Attending repair/rectification of leakages to water supply distribution lines 20 mm bore to 25 mm bore GI/PPR tubing with provision of necessary excavation, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/sockets/nipples as required at site complete all as specified and directed.
All as per item No 1 above but for GI tubing 40 mm bore to 50 mm bore
All as per item No 1 here-in-before but for GI tubing 80 mm bore to 100 mm bore.
Attending routine compaints of external water supply including rectification of minor defects by taking down of existing GI/PPR tubing up to 25 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of jumper valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site complete all as specified and directed.
All as per item No 4 above but for GI tubing 40 mm bore to 50 mm bore.
M&L for attending break down of water supply pipe line and repair to CI/DI/PPR water mains of size 80 mm to 300 mm bore at a given notice including necessary excavation in mud, in any type of soil by manual or using special T&P such as JCB etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars, bends/tail peaces etc and making joints complete all as specified and as directed. Note:- CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of sch 'A'.
Notes for Sl item No 1 to 6 :- (a) The contractor will be alloted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No II store yard on requirement basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth and getting out in hard/dense soil for removing/laying of pipe line complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for for re-fixing or removal complete with all fittings and connections of the following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Refixing of old steel tubing and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Notes for item No 11.01 to 11.07 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old steel tubing and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Notes for item No 13.01 to 13.07 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:-
15 mm dia
20 mm dia
25 mm dia
Taking up or down PPR pipe and connections, including cleaning the pipes free from scaling for for re-fixing or removal complete with all fittings and connections of the following sizes :-
32 mm dia
50 mm dia
110 mm dia
Refixing of old PPR Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
32 mm dia
63 mm dia
110 mm dia
Notes for item No 16.01 to 16.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old PPR Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:-
32 mm dia
63 mm dia
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings laid in trenches of following sizes including all fittings. Make : SFMC/KPT/WETFLOW/SAFE.
32 mm dia
63 mm dia
110 mm dia
Notes for item No 18.01 to 18.03 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply, laying and testing of polypropylene random copolymer (PP-R) (PN-10-SDR-11) 3 layer pipes ISI marked as per IS-15801, UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply all PPR plain and brass thread polypropylene random fittings fixed complete to walls, ceilings or in floors etc of following sizes including all fittings. Make : SFMC/ KPT/ WETFLOW/ SAFE.
32 mm dia
63 mm dia
Taking up unserviceable/ defective CI/DI/MS water mains (including all fitting ) with spigot/ socketed / flanged ends including disconnecting pipes and fittings in any position complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Refixing of old CI/DI/MS Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Notes for item No 21.01 to 21.05 :- (a) Excavation and Earth work shall be measured and paid separately.
S&F ductile iron pressure pipes, class K9, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Lead Joints / D-Joints will be measured and paid separately. (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required. (c) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Notes for item No 22.01 to 22.05 :- (a) Excavation and Earth work shall be measured and paid separately.
Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI /DI specials, Joints and Earth work shall be measured and paid sperately under relevant items of this schedule.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Supply only GI fittings 15 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Hex Nipple
All as per item No 24 above but for 20 mm bore.
Union
All equal Tee
Reducer Tee 20 x 20 x 15 mm
Socket
Reducer Socket 20 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer Elbow 20 x 15 mm
Elbow
Hex Nipple
All as per item No 24 above but for 25 mm bore.
Union
All equal Tee
Socket
Reducer Socket 25 x 20 mm
Reducer Socket 25 x 15 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer Elbow 25 x 20 mm
Reducer Elbow 25 x 15 mm
Reducer tee 25mm x 25 mm x 20mm
Reducer tee 25mm x 25 mm x 15mm
Hex Nipple
All as per item No 24 above but for 40 mm bore.
Union
All equal Tee
Socket
Reducer Socket 40 x 25 mm
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 40mm x 25mm
Reducer tee 40mm x 40mm x 25mm
Reducer tee 40mm x 40mm x 20mm
Hex Nipple
All as per item No 24 above but for 50 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer 50mm x 40mm.
Reducer 50mm x 25mm.
Elbow
Reducer elbow 50mm x 40mm
Reducer elbow 50mm x 25mm
Reducer tee 50mm x 50 mm x 40mm
Reducer tee 50mm x 50 mm x 25mm
Reducer tee 50mm x 50 mm x 20mm
Hex Nipple
All as per item No 24 above but for 80 mm bore.
Union
All equal Tee
Socket
Reducer 80mm x 50mm.
Reducer 80mm x 40mm.
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Elbow
Reducer elbow 80mm x 50mm
Reducer elbow 80mm x 40mm
Reducer tee 80mm x 80mm x 50mm
Reducer tee 80mm x 80mm x 40mm
Hex Nipple
All as per item No 24 above but for 100 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Nipple 150mm Long
Reducer 100mm x 80mm.
Reducer 100mm x 50mm.
Reducer 100mm x 40mm.
Elbow
Reducer elbow 100mm x 80mm
Reducer elbow 100mm x 50mm
Reducer elbow 100mm x 40mm
Reducer tee 100mm x 100mm x 80mm
Reducer tee 100mm x 100mm x 50mm
Reducer tee 100mm x 100mm x 40mm
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
Note for Sl item No 31.01 to 31.05, Make : Zoloto
Supply and fix in replacement of unserviceable ball brass valves, high pressure with polythene float and fly nut alongwith socket/reducer of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
M&L for dismantling of defective sluice valve for repairs, such as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly etc, replacement of jointing materials such as rubber sheets, nuts, bolts, washers and gland rope etc and refixing in its original position, testing on completion complete all as specified and directed for the following sizes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F CI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed.
All as per item No 34 above but for 200 mm bore to 300 mm bore.
Burning out lead joint in position for following sizes of CI/DI pipe, removing old lead complete all as specified and directed :-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
M&L for run lead joint for CI pipe/DI pipe including spun yarn etc for spigot and socket pipes and fittiings complete all as specified and directed for the following bore of pipes:-
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F in repairs cast iron detachable (D-Joints) heavy duty, ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/CI/DI/GI /PVC pipes of following sizes all as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately. (b) CI/GI/MS pipe for insertion will be measured and paid separately under relevant item of this schedule. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
S&F in replacement of Cast Iron sluice valves flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, non rising type K504, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
80 mm Dia
100 mm Dia
150 mm Dia
200 mm Dia
Cutting the existing road straight by manual, depth and width not less than 30 cm for pipes up to 100 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipes above 250 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
Construction of valve chamber of size 900 x 900 mm (Internal size) 900 mm deep with 200mm thick PCC block masonary walls built in CM 1:6 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brassd and keys(Godrej/Shell), MS handles and applying two coats of synthetic eanmel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
Supply and fixing PP-R Pipe fittings and accessories 32 mm bore, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Reducer Socket 32 x 25 mm
Socket
All equal Tee
Union
Gate Valve
All as item No 52 above but 63 mm bore :-
Reducer Socket 63 x 32 mm
Socket
All equal Tee
Reducer Tee 63 x 63 x 32 mm
Union
Gate Valve
All as item No 52 above but 110 mm bore :-
Socket
All equal Tee
M&L for replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as indicated for valve chamber top cover, 4 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with locking arrangement, mild steel handle, and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Renewal of single phase preventor cum low level water guard suitable for 4 to 7.5HP submersible pump set complete all as directed by Engineer-in-Charge.
Renewal of DOL starter suitable for 5/ 7.5 HP submersible pump set of 3 phase including necessary internal wiring with suitable copper wire including testing and commissioning complete all as directed by Engineer-in-Charge.
Taking out unserviceable GI socket from 50 mm column pipe and S&F new GI socket 50mm (ISI marked) long type, heavy duty suitable for the column pipe complete all as directed by Engineer-in-Charge.
Cutting the existing damaged threading of GI column pipe 50 mm dia and re-threading on lathe machine complete all as directed by Engineer-in-Charge.
Removing old unserviceable column pipe as obtained from lowering of submersible pump set and S&F new GI column pipe 50mm dia, heavy duty, ISI marked, 3 metre length each, both ends machine threaded with long threaded socket complete all as directed by Engr-in-Charger.
Removing unserviceable PVC water proof cable of any size as obtained from lowering of submersible pump set and S&F new PVC water proof copper cable of size 3 core 2.5 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
M&L for cable joint for water proof cable of 3 core 2.5 /4.0 sqmm flat copper cable including testing and commissioning complete all as directed by Engineer-in-Charge.
Removing unserviceable PVC water proof cable of any size as obtained from lowering of submersible pump set and S&F new PVC water proof copper cable of size 3 core 4.0sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
M&L for cable joint for water proof cable of 3 core 4.0 sqmm flat copper cable including testing and commissioning complete all as directed by Engineer-in-Charge.
Renewal of water guard cathode including copper cable of 1.5 Sqmm upto the depth of 70 mtrs complete all as directed by Engr-in-Charge.
S&F Borewell casing cover 200 to 300 mm
M&L for flushing of the existing borewells of size 150 mm dia upto 350 feet depth by drilling machine by mechanically method into the above well connected to a pneumatic compressor after taking out the submersible pumpset with necessary hoisting equipment and flushing the bore well complete with compressor air and flushing bore well till discharge of fresh water is obtained subject to the entire satisfaction of Engr-in-charge and lowering down the submersible pump set in position complete all as directed by Engineer-in-charge.
M&L for flushing of the existing borewells of size 150 mm dia above 350 feet and upto 650 feet depth by drilling machine by mechanically method into the above well connected to a pneumatic compressor after taking out the submersible pumpset with necessary hoisting equipment and flushing the bore well complete with compressor air and flushing bore well till discharge of fresh water is obtained subject to the entire satisfaction of Engr-in-charge and lowering down the submersible pump set in position complete all as directed by Engineer-in-charge.
Taking out submersible pumpset of any capacity and type from the borewell of depth not exc 200 metres for carrying out repairs including cleaning and applying one coats of anti corrosive paint and lowering the same in position and commissioning after carrying out the repairs as required complete all as directed by Engineer-in-Charge. Note:- i) Rewinding of burnout winding of motor,supply of parts repairs to pumpset will be measured under relevant item of this schedule
Repairs to submersible motor electric driven up to 5 HP capacity of any make and type by rewinding of the motor with same gauge and weight of PVC insulated copper wire and other required insulating materials and renewal of thrust plate, bearing , reassembling, including testing and commissioning complete all as directed by Engineer-in-Charge.
Repairs to submersible motor of electric driver, above 7.5 HP up to 10 HP capacity of any make and any type by rewinding the motor with same gauge and weight of PVC insulated copper wire and other required insulating materials and renewal of thrust plate, bearing ,reassembling, including testing and commissioning complete all as directed by Engineer-in-Charge.
Repairs to submersible pumpset upto 18 stage, replacing the worn out spare parts with new spare parts overhauling and greasing including testing complete all as directed by Engr-in-Charge. Note:- spare parts as required for functioning of of PUMP set shall be included in the quoted rate
Supply and installation CPRI approved pump starter electric control panel board, for out door use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT INCLUDING 2 NOS GODREJ 7 LIVER LOCK) dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 32 Amps -01 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-01 No. (c) Single hase preventor realy type Sz% (6wire), 415 volts -01 No (d) Dry run protector -1 Nos
Material labour for removing submerceable pump motor set of capacity up to 10 HP stuck in side the borewell of depth up to 200 meter including necessary Compressure ,machinaries , removing and replacement of casing as required and reinstall the same inside the borewell after repair complete all including flushing of bore well complete all as directed and specified. Note; rate quoted by the contractor inclusive of all arrangement required to remove the submerceable pump set stuck inside the boire well and reinstall the same after repair including removing and refixing of coloumn pipe , casing pipe, electrical connections ets as required . Repairing of submerceable motor and PVC casing pipe will be measured and paid separately under relivent items
M&L for heavy dyty PVC casing pipe of size 150 mm for bore well complete all specified and directed.
M&L For Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 300x300 mm complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL/TRUE POWER Note :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, MS pipe 100 mm dia 4.5 mm thick in any length including jointing materials to carry pipe line up to 80 mm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size 1.15MX1.25MX0.35M (proper space shall be provided for working in each compartment), 3 Phase 4 wire system Outdoor type 3.15mm ,double door front and back openeing type sloped canopy(Hood) on top extended 100mm all-around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 120 Sqmm 3.5 Core in and out( panel board shall have sufficent space to accommodate spare cables also if required) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Anle iron frame with leg made out of of 50x50x6mm angle duly painted and embeded in PCC 1:2:4, type C-2, 30 Cm below ground level and 45 Cm above ground level Etc complete including disconnecting all electrical & mechanical connections and taking down old unserviceable and consisting the following provisions:- .
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of suitable size 1.15MX1.25MX0.35M (proper space shall be provided for working in each compartment), 3 Phase 4 wire system Outdoor type 3.15mm ,double door front and back openeing type sloped canopy(Hood) on top extended 100mm all-around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 120 Sqmm 3.5 Core in and out( panel board shall have sufficent space to accommodate spare cables also if required) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 3.15mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs,Panel mounted on Anle iron frame with leg made out of of 50x50x6mm angle duly painted and embeded in PCC 1:2:4, type C-2, 30 Cm below ground level and 45 Cm above ground level Etc complete including disconnecting all electrical & mechanical connections and taking down old unserviceable and consisting the following provisions:-
Notes for Sl no 69 and 70 : Note:- (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls IF ANY including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces (c) The panel shall be Fabricated from a reputed firm(CPRI Approved) . Make of MCCB's: L&T or equivalent in Havells, lEGRAND etc. (d) All Internal connection between MCCB and Changeover and Bus bar shall be connected by aluminium strip of suitable size and capacity. (e) All MCCB to be connected with both side Spreader Link. (f) Sufficient space to be provided for cable connection between MCCB and Bottom of the panel board. (g) Base of the panel should not be less than 45 cm above the ground level. Necessar PCC for base /foundation required deemed to be included in the quoted rate. (j) The rate shall deemed to be include in the item rate. (k) All serviceable MCCB in existing panel board are the property of the department
M&L For Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 300x300 mm complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL/TRUE POWER Note :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as requied 32x6mm galvanised iron strip including taking old un serviceable one.
Supply,test,install & commsissioning of Out door type 3.15mm thickness canopy hood type Bus bar chambers(including 4 bus bars i.e R,Y,B and neutral),3-Ph with netral,1100volts,50Hz including suitable sheet metal enclosure along with necessary screws,nuts,bolts and other Misc accessroies and making connections(input &out put) with cable terminal ends complete for the following current carrying capacities,Panel mounted on suitable size & thickness of angle iron frame(proper mounting shall be done) duly painted and embeded in necessary required quatnity of PCC 1:3:6 type C1, 30cm below ground level and 15cm above ground level including taking down old unserviceable and consisting the following provisions:- 4-Way, 100 Amps
All as per Item no 73 above but 4-Way,160Amps
Supply,test,laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade, laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up to the termination point(as directed by Engr-in-Charge) with necessary end terminations with suitable size cable lugs cable glands, fixing of lugs with crimping with tool,nuts,boltsetc of the following sizes complete all as specified and directed by Engr-in-Charge :-
3.5core x 95 Sqmm
3.5core x 70 Sqmm
3.5 core x 35 sqmm.
3.5 x 25 Sqmm
4 core x 16 Sqmm
4 core x 10 Sqmm
2 core x 10 Sqmm
Excavation in trenches not exc 1.5 mtr wide and n.exc 1.5 mtr in deep and getting out in Hard/Dense soil laying of cables etc.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as directed by Engineer-in-Charge.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point complete all as directed by Engineer-in-charge.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down etc complete all as specified and directed. Note :- Sand cushion after punning down thickness 18 cm shall be measured for payment purpose.
Taking out and Relaying of LT cable of size10sq mm to120 Sqmm 2/3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item) (b) Retrived serviceable bricks/ PCC cover shall be reused under relevent item)
Supply and lay GI tubing , 100 mm bore light grade for cable protection at road crossing / on poles/ for fixing of post top lantren and tubing sealed at both ends after laying the cables complete all as directed by Engineer-in-Charge. Make :- ISI
All as per item no:81 above but 80 mm bore
All as per item no:81 above but 50 mm bore
All as per item no:81 above but 40 mm bore
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 150 sqmm complete including taking out old unserviceable one all as specifide and directed.
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete including taking out old unserviceable one all as specifide and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, GI pipe 50 mm dia medium grade in any length including jointing materials to carry LT UG cables of size upto 120 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
M&L brick protection with common burnt brick sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed by Engr-in-charge.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
M&L for Supply,test,erection & commissioning of Steel tubalar swaged poles staying in a truely vertical position till the foundations are properly set with the help crane complete with cast iron base plate, finial taper plug, bolts, nuts & screws including drilling of holes to poles for clamps & hooks for running of earth wire/Strip complete all as specified type 410 SP-31,09 mtrs LT poles and inluding and applying two coats of aluminum paint over a coat of red oxide primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engr-in-Charge. Note:-(i)Crane charges for erection shall be deemed to be including in quoted rate. (ii) Earth work,PCC,coping shall be measured and paid separately. (iii) The rates include staying the poles in atruely vertical position till the foundations are properly set. (iv)The rates include cast iron base plate,nuts,bolts,screws,painting of steel tubular poles,drilling of holes in steel tubular poles for fixing of clamps,hooks for continuous earth wire/strip. (v) The rate quoted shall be inclusive of pole painting.
Supply & laying cement concrete in foundation (1:4:8) type D2 using 40 mm graded broken stone aggregate including form work complete as specified
Supply and laying PCC (1:3:6) 20mm graded aggregate type C1 forcoping of Steel tubalar pole 09 mtrs long complete all as directed by Engr-in-charge
Supply and laying PCC (1:2:4) type B2 40mm graded aggregate for foundation of Steel tubular pole 09 mtrs long complete all as directed by Engr-in-charge
Supply & Fix of LED flood light fittings of capacity 60W with integral electronic driver,Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium flood light with high power LEDs as light source, suitable for highlighting architectural features or Area Lighting. Also suitable to rough services/installations including connecting with necessary cable and screws,nuts,bolts complete all as directed by Engr-in-Charge. Make:Havells cat no.JETAQUANTOPLUSFLP60WLED757SYM or its techno commerical equivalent in Philips/Wipro/Halonix
Framed work Mild steel framed work with angle iron frame for mounting Light fittings in four sides including including necessary welding , bolts, washer and painting exposed surfaces with two coat of synethic enemal paint over one coat of Red oxide primer all as specified and directed by Engr-in-Charge
Supply and fixing of PVC Junction box of size 140mm x 140mm x95mm ,light weight pole mounting hinged type including MCB DP 16Amps -1 No including necessary clamp for MCB mounting and mounting of Box on pole with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as directed by Engr-in-charge. Make :- SINTEX cat No.GSJB1414 or its techno commercial equivalent in Polycon
Taking down LED street light fitting/ LED flood light fitting of any watts and type from any height of pole/walls/any location and detecting the fault in the fitting by checking the accessories, wiring and refixing the same after repairs complete all as directed by Engineer-in-Charge. Note : Spares like driver and other accessories etc will be measured and paid separately under relevant items
S&F LED Driver suitable for upto 45 watts to 60 watts LED light fittings complete all as specified and directed. Make :Havells/Philips/Bajaj/Wipro/Luker.
S&F LED Driver suitable for from 72 watts to 150 watts LED light fittings complete all as specified and directed. Make :Havells/Philips/Bajaj/Wipro/Luker. Note for item No.05&06:Drivers shall be techincally compitable for existing fittings & frame size shall be matched to existing fittings.
S&F PVC insulated,unarmoured 3 core 2.5Sqmm Aluminum cable including making neccessary cable terminations,lugs,glans complete all as directed by Engr - in-Charge
Cutting and trimming trees branches any girth and any size touching to overhead lines and cleaning the distance 1.5 mtr length both side of OH line with in a span of 35 mtrs each disposing the same, clearing the site all as directed by Engineer-in-Charge.
M&L for cleaning LT/Street light poles of 8.5/9.0 mtrs long and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of aluminum paint over a coat of red oxide primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engineer-in-Charge. Make:- ASIAN (APCOLITE)/ SHALIMAR (SUPER LAC)/ BERGER (LUXOL)
Supply, fixing, connecting and testing post top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity 1X35/45 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed. Make:- PHILIPS Cat Part No BGP161 LED2500/NW PSU 220-240V 7043 IN or CG MODEL NO LPTO 40 CDL/ Surya model lP07 501-XXX-57-CL / Havells Cat No. RUBYPT35WLED757PSYMTOPC or Wipro cat No.LP07-501-XXX-57-CL.
Supply, fixing, connecting and testing decorative LED Bollard light with opal diffuser and aluminium reflector of 8/9/11 watt LED including nut, bolts, washers, clamps etc as in repair complete all as specified and directed. Make:- C&S Cat Part NoLTGLCW9WLED or SURYA MODEL NO SLEBL 6W BLK800 or Havells Cat No. BAMBOOBL8WLED830SSYMTOPCM (1.0) or Wipro cat No.LB14-131-XXX-65-05.
Supply, fixing, connecting and testing energy saving, environmental friendly long life Varsatile pressure die cast aluminium alloy for housing (heat sink) with IP66 protection road way light fitting with high power LED as light source of capacity 72 watts with warranty option with suitable driver and cable gland for maintaining ingress protection with Epoxy powder coated siemens grey finish after phosphochromate treatment, Tempered protective toughened glass,thermal shock and impact resistant fixed to the housing with SS screws , High efficiency long life LED chip in modules with lumen efficacy of not less than 100 lm/W with PC lens and system lumen 7400. Powered by Built-in electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection. 5700k, CRI≥70, THD≤10%, PF≥.95, IP66, IK07.Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +50 DEG.C; Input Supply Voltage Range:140-270 V, Frequency : 50-60 HZ, Driver
Safety requirement standards :IS 15885-2-13, Test report to be submitted for Driver performance requirements as per IS 16104, for Photo bilogical safety norms as per : IS 16108, Certification as per LM 79 for Luminaire , LM 80 for LED Source, with all standard accessories etc, including disconnecting and taking down old existing light fittings any type/capacity from any height/position complete all as specified and as directed. Make: Havells Cat No. ENDURACITYLINERNEOSL72WLEDPASYBOTG or its techno commerical equivalent make in wipro/CG/Philips approved by Accepting officer
Supply, lay, test and commissioning of twin core 1100 volt grade aluminium service wire cross sectional area 4.0 Sqmm for connection of lights as in repairs complete all as specified and directed
Supply, lay, test and commissioning of twin core 1100 volt grade aluminium service wire cross sectional area 6.0 Sqmm for connection of lights as in repairs complete all as specified and directed
Supply, lay, test and commissioning of twin core 1100 volt grade aluminium service wire cross sectional area 10 Sqmm for connection of lights as in repairs complete all as specified and directed
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 32-63Amps, 16kA, 415volts,50 Hz, suitable for exisitng location(frame size shall be matched with existing one)for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs,Spreader links, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL. Note for item no.36.00 to 52.00: (i)The above item shall be executed immediately as and when required basis.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 100Amps, 16/25kA, 415volts,50 Hz, suitable for exisitng location(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs,Spreader links, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 125Amps, 25kA, 415volts,50 Hz, suitable for exisitng location(frame size shall be matched with existing one)for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs,Spreader links, glands,nuts,bolts and screws complete all as specified and directed.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 200Amps, 25kA, 415volts,50 Hz, with adjustable settings, suitable for exisitng location(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs,Spreader links, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 250Amps, 35/36kA, 415volts,50 Hz, with adjustable settings, suitable for exisitng location(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs,Spreader links, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 200Amps, 35/36kA, 415volts,50 Hz, with adjustable settings, suitable for exisitng location(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs,Spreader links, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 250Amps, 25kA, 415volts,50 Hz, with adjustable settings, suitable for exisitng location(frame size shall be matched with existing one), for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs,Spreader links, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 315 Amps to 400Amps, 50kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse,suitable for exisitng location(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs,Spreader links, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Supply&Fixing of 3 pole MCB 32-63amps,C-curve,10kA,50Hz,440v in existing location including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
M&L on load change over switch 100 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in sheet metal enclosure type for fixing in existing location including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
M&L Off load change over switch 200 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,side handle operated with sheet metal enclosure suitable for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
Excavation of transformer structure yard upto a depth of 300mm and Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 above the starting point complete all as directed by Engr -in-charge.
Supply and spread stone dust (powder) of thickness 50mm in 2 pole/6pole structure yard complete all as directed by Engr-in-charge.
Supply and spread grade stone aggregate 40 mm in structure yard of 2/4 poles complete all as directed by Engr-in-charge.
Supply and spread grade stone aggregate 20 mm in structure yard of 2/4 poles complete all as directed by Engr-in-charge.
Supply and connect LT 1100 V outdoor type cable straight through heat shrinkable epoxy joint kit suitable for the following sizes with necessary jointing materials complete all as directed by Engr-in-charge. Make :- M-SEAL/ DENSON/3-M/ RAYCHEM
3.5 core x 25/35 sqmm.
3.5 core x 70/95 sqmm.
3.5 core x 120/150 sqmm.
Isolate,disconnect,dismantle the burnt out lugs from main switches/MCCB/ACB/Breakers and Supply &fix new lugs with crimping tool as per existing one including fixing, insulation, termination tomain switches/MCCB/ACB/Breakers for the following sizes of cables complete all as directed by Engr -In-Charge. Note : cleaning the cable termination ends insulation as required length and fixing new lugs as per size including well crimping to the lugs for both ends of cable complete are included in quoted rat
25 sqmm to 50 sqmm
70 sqmm to 95 sqmm
120 sqm to 240 sqmm
up to 16 Sqmm
M&L for Disconnecting the the unserviceable LT/Street light UG cable laid in trenches/surface/wall/under ground/tunnel/pipe from LT/Street light pole to Panel board/Kisok/Busbar chamber/feeder pillar box and meggingring the same and removed the damaged portion,jointing the rest of cable with necessary accessroies complete all as directed by Engr-in-Chrage. Note: if required Earth work shall be measured and paid separately under relevant items.
Dismantling LT/Street light pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge.
S&F CPRI approved factory made fabricated out of 3.15mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back with necessary fixing arrangement as per site requirement, with necessary holes duly drilled for incoming and out going cables with glad suitable for panel board MCCB/HRC unit incomer capacity of 63Amps to 800 Amps complete all as directed by Engineer-in-Charge.
S&F Aluminium bus bar of current carrying capacity 800 Amps in exsiting panel board including making all necessary eletrical/mechanical connections with suitable nut bolts,screws,epoxy insulator compelete all as directed by Engr-in-charge
S&F Aluminium bus bar of current carrying capacity 630 Amps in exsiting panel board including making all necessary eletrical/mechanical connections with suitable nut bolts,screws,epoxy insulator compelete all as directed by Engr-in-charge
S&F Aluminium bus bar of current carrying capacity 400 Amps in exsiting panel board including making all necessary eletrical/mechanical connections with suitable nut bolts,screws,epoxy insulator compelete all as directed by Engr-in-charge
Fabrication and installation of GI pipe bracket made of midium Grade tubing of size 40 mm dia, duly bended by hot forgoing after filling of sand, length 1.20 mtr including providing two pair of MS flat strip clamps 40 mm x 4 mm with GI bolts nuts and washer complete all as specified and directed
Material and Labour for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 2.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm including 20mm dia PVC conduit of dia 20 mm medium gradeexclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified
Supply and replace contactor ML 3 with coil operating voltage 230 Volt complete all as directed
Timer Analog Type Suitable for 24 hours operation of street light of 16 amps capacity (LEGRAND/AVV/CG)
Excavating in Trenches, not exc. 1.50 METRE wide and exc. 1.50 METRE but not exc. 3.00 METRE in depth, for Foundation of Poles, etc. and getting out in hard/dense Soil, complete all as specified and as directed.
Supply ,Install Testing &Commissioning of wall mounted Indoor type totally enclosed LT panel Board CPRI APPROVED , IP 55 compartmentalised design, dust and varmin proof of suitable size suitable for 440 Volt 3 phase 4 wire system made out of 2.0mm thick CRCA sheet and built upon regid frame work having front hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. The pannel shall be Epoxy Powdwer Coated and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incomming/outgoing cable holes at the bottom and TOP. The Panel shall be emmbeded with 40 x 4 mm MS Angle Iron frame a complete all as specified and directed by Engr in charge. ( Sub Area)
Dismantling ACSR or AAC Conductors from the disturbed Span including Line Spacer, etc. Serviceable Materials Keep in Safe Custody for Re-use, complete all as specified and as directed.
Supply and replace GI pipe fixed on the top of gate piller by 50 mm dia medium grade GI pipe of length 30 cm( 20 CM inside the piller and 10cm above the piller ncluding necessary cement work and making hole on GI pipe if required complete all as directed. Note: Quoted rate inclusive of making good of dosturbed suface including necessary painting to match with the adjoining surface.
Supply and fixing lantren of dia 60 CM for fixing of flood light, cap type to be fixed on the top of 9 m SP-31 Steel pole , made of MS pip medium grade dia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nos including two coat of aliminium painting over a coat of redoxide primer complete all as directed
M&L for making 2 nos hole in existing steel tubuler pole by welding for passing of street light cable inside the pole ( one near JB and another near buttom portion of street light bracket ) complete all as specified and directed
diesel power services (a.p)
omsai thermax engineers
STANDARD AGENCIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .