Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-01₹9.9 LAccepted-AOC | L-01 | Accepted-AOC Being lowest | |
| 2 | L-02₹10.2 L+₹3,360 (0.33%)Rejected-Finance | L-02 | Rejected-Finance Not being lowest | |
| 3 | L-03₹10.3 L+₹5,260 (0.52%)Rejected-Finance | L-03 | Rejected-Finance Not being lowest | |
| 4 | L-04₹10.3 L+₹9,080 (0.89%)Rejected-Finance | L-04 | Rejected-Finance Not being lowest | |
| 5 | L-05₹10.3 L+₹12,527 (1.23%)Rejected-Finance | L-05 | Rejected-Finance Not being lowest |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
9 Dec 2021, 6:00 pmClosed
AGE (I) Darjeeling
P.O. Jalapahar Dist- Darjeeling (WB) Pin- 734103
REPAIR REPLACEMENT OF INTERNAL CONCEALED GI PIPE LINE, INTERNAL SEWAGE PIPE LINE, REPAIR CLEANING WORKS AND MISC. WORKS IN JALAPAHAR, KATAPAHAR AND KURSEONG AREA UNDER AGE I DARJEELING
2021_MES_475442_2
8837/E8
Open Tender
Civil Works
Item Rate
182 days
AGE (I) Darjeeling
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Darjeeling
₹19,200
Yes
21 Dec 2021
15 Nov 2021
11 Dec 2021
15 Nov 2021
9 Dec 2021
26 Nov 2021
15 Nov 2021 - 20 Nov 2021
Amount
Cleaning of service water tank exc 250 and n.exc 500 ltrs capacity RCC/PVC and connected circulating pipes at any position by removing sludge, mud, moss, moulds, efflorescent salts, oil spots etc or any other foreign material from the bottom, cover and internal surfaces by scraping using wire brush draining out the water in the tank and washing internally by using bleaching powder and again draining out the water in the tank and applying single coat of lime washing on all tanks and marking the date of cleaning with white paint on black back ground complete all as specified and as directed.
All as per ser item No 01 here-in-before but exc 500 & n exc 1000 Ltrs capacity complete all as specified and as directed.
All as per ser item No 01 here-in- before exc 1000 & n exc 2000 Ltrs capacity complete all as specified and as directed..
S&F in-repair 15 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 142gm) complete all as specified and as directed. Make- PRAYAG/ POLYTUFF
All as per ser item No 04 here-in-before but for 20 mm dia (min weight 210gm) complete all as specified and as directed. Make- PRAYAG/ POLYTUFF
All as per ser item No 04 here-in-before but for 25 mm dia (min weight 455gm) complete all as specified and as directed. Make- PRAYAG/ POLYTUFF
Dismantling of old unserviceable PVC water storage tank 500 ltrs capacity and removing from site, complete all as specified and as directed.
All as per ser item No 07 here-in-before but 1000 Ltrs capacity complete all as specified and as directed.
All as per ser item No 07 here-in-before but 2000 Ltrs capacity complete all as specified and as directed.
S&F Rotational Moulded Polyethylene Water Storage Tank 500 Litre capacity (Cylindrical Vertical with Closed Top), 3 layered, hoisted and fixed in position, all as specified in MES Schedule Part-I, complete all as specified and as directed. Make- SINTEX/ POLYCON/ SUPREME
All as per ser item No 10 here-in-before but 1000 Ltrs capacity complete all as specified and as directed. Make- SINTEX/ POLYCON/ SUPREME
All as per ser item No 10 here-in-before but 2000 Ltrs capacity complete all as specified and as directed. Make- SINTEX/ POLYCON/ SUPREME
S&F in repair PVC water tank cover suitable for any capacity complete all as specified and as directed.
Taking down / out old unserviceable GI tubing upto 15mm bore (dia) including all fittings and fixture from floor/wall or trenches including cleaning and stacking for refixing / reuse and removal unusable materals from site of work complete all as directed.
All as per ser item No 14 above but 20 mm bore of pipe complete all as specified and as directed.
All as per ser item No 14 here-in-before but 25 mm bore of pipe complete all as specified and as directed.
S&F 15mm bore (dia) GI tubing 'medium grade' galvanised with all fittings fixed to wall, ceiling or laid in floors complete all as specified and as directed. Make- JINDAL/ TATA/ BANSAL
All as per ser item No 17 above but 20 mm bore of pipe complete all as specified and as directed. Make- JINDAL/ TATA/ BANSAL
All as per ser item No 17 here-in-before but 25 mm bore of pipe complete all as specified and as directed. Make- JINDAL/ TATA/ BANSAL
Refixing old Steel Tubing 15mm bore (dia) and Connections (Serviceable Pipes and Connections obtained from Sl No. 14 here-in-before) in new or old position (Walls, Ceiling, Floors, laid in trench) including cleaning both inner and outer surfaces of Pipes by using Wire Brush including provision of new GI Connections (as required ordered at Sites), complete all as specified and as directed.
All as per ser item No 20 here-in-before but 20 mm bore of pipe (Serviceable Pipes and Connections obtained from Sl No. 15 here-in-before), complete all as specified and as directed.
All as per ser item No 20 here-in-before but 25 mm bore of pipe (Serviceable Pipes and Connections obtained from Sl No. 16 here-in-before), complete all as specified and as directed.
Demolition of brick work or stone boulders masonry built in cement mortar including all quoins, arches, pillar etc. but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for brick work with Fly Ash bricks straight or curved on plan exceeding 6M mean radius in cement mortar (1:4) complete all as specified and as directed.
M&L for walling or random rubble uncoursed stone masonry, well bonded, bedded and solidly hearted and built in cement mortar 1:6 complete all as specified and as directed.
All as per ser item No 25 here-in-before but except stone complete all as specified and as directed.
Taking down cement plaster of any descriotion from brick,stone or concrete walls etc including racking out joints, hacking for keys scrubbing down with water etc complete all as specified and as directed.
M&L 15mm thick rendering in cement mortar 1:6 on fair face of brick work finished even and smooth without using extra cement complete all as specified and as directed.
M&L rendering 15 mm thick in cement mortar 1:4 on fair faces of brickwork or concrete surfaces and finishing even and smooth without using extra cement complete all as specified and as directed.
M&L preparing new plastered surfaces of wall of any description and applying three coats of white wash on walls complete all as specified and as directed.
M&L preparing new plastered surfaces of wall and applying two coats of colour wash over one coat of white wash on walls complete all as specified and as directed.
Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation etc.) or Insulation Board/Slab/Blankets of any thickness, etc. including Cover Fillets of any description, complete all as specified and as directed.
Demolition of Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed.
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), removing from the Sites and rubbish off the Premises, complete all as specified and as directed.
S&F GI Snap Grid of size 605x605mm Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. as per Specification and Drawing of MES Schedule Part-II, complete all as specified and as directed.
S&F of 10mm thick PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing, complete all as specified and as directed.
M&L for Screed Bed or Bedding Layer 20mm thick in Cement Mortar 1:6 for laying Floor Finishes/Tiles, complete all as specified and as directed.
M&L for Rendering or Bedding Layer 10mm thick in Cement Mortar 1:3 on Walls, etc. for fixing Tiles as Skirtings, Dados, etc, complete all as specified and as directed.
M&L for providing non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm, in floors etc set and jointed neat cement slurry and pointed in white or coloured cement to match complete all as specified as directed. Note - Screed bed will be measured to paid seperately.
M&L Glazed Ceramic Tiles 450x350x7mm thick in Vertical Surface i.e. Dado, Skirting, etc., Set and Jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, complete all as specified and as directed. NOTE : Screed Bed will be measured and paid separately under appropriate Item.
M&L for Granite (of any type) tiles 20mm thick machine cut, as in flooring, coocking platform, etc., bedded andjointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, complete all as specified and as directed. NOTE : Screed Bed will be measured and paid separately under appropriate Item.
Labour only for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and as directed.
M&L for Plain Cement Concrete 1:4:8, type D-2 (40mm graded aggregate), as in Sub-base of Floor, Path, Hardstanding, Steps, etc., laid in alternate bays, finishing Concrete Surfaces Even and Fair, complete all as specified and as directed.
M&L for Cutting chases not exc 10 cm girth on masonary brick wall for concealed water tubing or concealed conduit wiring, etc., and making good the disturbed surfaces by pointing in cement mortar 1:3, complete all as specified and as directed.
S&F in repair, Vitreous China Wash Hand Basin 550x 400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, a Pair of Cast Iron Brackets duly Painted/ Erecting Stand including Cutting and Pinning in Ends, Making Good disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed. Make:- Hindware/ Jaquar/ Prayag
S&F in repair Vitreous China cistern mounted single piece EWC with UF soft Close Slim seat cover and connecting accessories 370x 670x 720mm in size, White in colour, including connection to drain (or outgoing pipe) and to Flushing Pipe, Anti-syphonage Pipe, etc. and Making Good to Floor /distrubed surfaces, complete all as specified and as directed.. Make- Jaquar, Cat part No- LYS-WHT-38851S220UFSMN
Supply and fix in-repair of Brass Chromium Plated Towel Rack, 600mm long between flanges with bracket and fixed to Walls with Chromium plated Brass Screws, complete all as specified and as directed. Make:- Hindware/ Jaquar/ Prayag/ Somany
Supply and fix in-repair of Brass Chromium Plated Towel Ring, fixed to Walls with Chromium plated Brass Screws, complete all as specified and as directed. Make:- Hindware/ Jaquar/ Prayag/ Somany
S&F in-repair of fancy type brass chromium plated Health Faucet with 1.0 metre long braided hose, fixed to wall with necessary mounting arrangements, complete all as specified and as directed. Make- Jaquar(Cat part no- ALD-565)
S&F in-repair of Stainless steel Bucket with cockroach trap of size 6'x6', fixed in cement morter 1:3, complete all as specified and as directed. Make- ERA (Model-5219)
Supply and fix in-repair High neck Single lever Basin Mixer w/o popup waste mixer for mixing hot & cold water, 15mm bore (dia), Fancy type, brass chromium plated, screwed down, screwed for Iron Pipe or for Brass Ferrule and fixed, complete all as specified and as directed. Make- Jaquar, cat part no- FUS-29005NB
Supply and fix in-repair Angular Stop Valve 15mm bore (dia), Brass Chromium Plated, (Consealed Type), screwed down, high pressure, with Crutch or Butter-fly Handle, screwed both Ends for Iron Pipe or for Unions and fixed, complete all as specified and as directed. Make- Jaquar, cat part no- FUS-29053
S&F in-repair of PVC Connection Pipe 15mm size with PTMT Nuts of length 450mm, complete all as specified and as directed. Make- Prayag/ Polytuff
S&F in-repair of Flexible Waste Pipe 32 mm bore dia (bore) 115 Cm long for Wash Hand Basin, Sink, etc., complete all as specified and as directed. Make- Prayag/ Polytuff
Supplying and fixing in-repair of 16 mm bore (outer dia) CPVC pipes of SDR 11 with Plain CPVC SDR 11 fittings fixed to walls/ceiling or laying in floors complete all as specified. Make- Supreme/ Astral/ Ori-Plast/ Prince
Supplying and fixing in-repair of 20 mm bore (outer dia) CPVC pipes of SDR 11 with Plain CPVC SDR 11 fittings fixed to walls/ceiling or laying in floors complete all as specified. Make- Supreme/ Astral/ Ori-Plast/ Prince
S&F in repair Vitreous China cistern mounted single piece rimless EWC with UF soft Close Slim seat cover and connecting accessories 370x 665x 770mm in size, White in colour, including connection to drain (or outgoing pipe) and to Flushing Pipe, Anti-syphonage Pipe, etc. and Making Good to Floor /distrubed surfaces, complete all as specified and as directed.. Make- Jaquar, Cat part No- FSS-WHT-29853S300UFSMN
M/S TSHERING BHUTIA
GEETA CONSTRUCTION
BIMAL BHATTRAI
KWOK YING CHIU
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .