| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST AND RESONABLE | |
| 2 | L2₹22.9 L+₹1.9 L (9.16%)Rejected-Finance | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹23.7 L+₹2.8 L (13.2%)Rejected-Finance CHALIHA GAON PO CHALIHA DISTT JORHAT ASSAM PIN 785004 | JORHAT | ASSAM | 785004 | L3 | Rejected-Finance not being lowet |
Tender Value
Refer Docs
EMD Value
₹39,000
Closing Date
28 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GARRISON ENGINEER JORHAT, MES, JORHAT-785005
CERTAIN REVENUE WORKS AND MINOR WORKS AT LICUBARI UNDER GE JORHAT
2021_MES_490029_2
8037/E8
Open Tender
Civil Works
Item Rate
120 days
GE JORHAT
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE JORHAT
₹39,000
Yes
5 Mar 2022
11 Feb 2022
1 Mar 2022
11 Feb 2022
28 Feb 2022
16 Feb 2022
11 Feb 2022 - 14 Feb 2022
90 days
Amount
NOTES :(i)The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Material and labour for 75 mm thick plain cement concrete M-10(Nominal Mix) using 20 mm graded stone aggregate as in plinth protection, finished even and smooth without using extra cement complete all as specified and as directed.
Material & Labour of 18mm thick granite ( of any type) work ( table rubbed and polished in pillars and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust admixture of pigment to match with shade of granite over 15mm thick screed bed layer in CM (1:4) including taking down existing one complete all as specified and as directed.
Material and labour for pre-polished chequered Cement Concrete tiles of 25 mm minimum thick, size of (square/ rectangular) area of each tile exceeding 0.09 Sqm but not exceeding 0.16 Sqm double layer machine pressed set ( as per IS 1237-2012), jointed and pointed in neat cement slurry in floors and cut & polished in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Material and labour for preparation of old steel surface and applying two coats of synthetic enamel paint in camoflage pattern (glossy finish) with spray machine over a coat of red oxide primer on old steel and iron surfaces complete all as specified and as directed..
Material and labour for preparation of new surfaces and and applying 2 coats of cement based paint over a coat of alkali based primer complete all as specified and directed.
Precast Reinforced Cement Concete jalli type M-15(Nominal Mix) B-0 using 12.5mm graded stone aggregate, set in Cement Mortar (1:4), 25 mm thick, including all moulding but excluding frame.
Precast Reinforced Cement Concete railing baluster M-25(Nominal Mix) using 20 mm graded stone aggregate,
Material and labour for old Brick work with bricks class designation 75, old size, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
Rendering 15 mm in Cement Mortar 1:6 on fair faces of brick work or concrete surfaces finished even smooth without using extra cement to the plastered surface complete all as specified and as directed.
Material and labour for Rendering 15mm thick plaster in Cement Mortar (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement, with water proofing treatment. Note:- Water proofing compound shall be measure and paid separately
Supply only integral liquid water proofing compound complete all as specified and directed.
Material and labour for Preparation of new surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre of required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 1.5 mm thick cement base wall putty complete all as specified and directed.
Material and labour for preparation of new surfaces and and applying 2 coats of cement based paint over a coat of alkali based primer complete all as specified and directed.
Reinforced Cement Concrete M-20 (Nominal mix) using 20 mm graded stone aggregate as in slab complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete.
Use and waste of formwork to soffits of suspended slabs such as roof slab, floor slabs, landings not exceeding 200 mm thick (horizontal or sloping) for rough finished surfaces of concrete.
Material and labour for High strength steel TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally and binding with and including mild steel (annealed) wire not less than 0.90 mm dia
Material and labour for TMT Bars 8nmm dia and over cut to length bent to shape required inculding cranking bending spirally hooping for columns etc and binding with MS wire ennealed less than 0.9mm dia or securing with clip complete all as specified and directed.
Material, labour and fixed of power coated aluminium snap grid frame work for false ceiling, size of grid 605 x 605 mm, including aluminium main/closs tee of size 35mm x 23mm x 1.5 mm ( minimum) aluminum BULBED TEES section and aluminium angle of 25mm X25mm X1.5mm thick, sutiable type GI wire hanging arrangement with adjuster all as specified in clause no 10.38 in SSR part-I and including 6 mm thick high pressure steam cured non asbestos fibre cement designer board as per IS 14862 with applying of two coats of acrylic distemper over a coat of primer including taking dwon existing false ceiling system complete all as specified and directed. Make (i) ALUMINUM SNAP GRID:- HINDALCO/ INDALCO/ JINDAL (ii) Non Asbestos Fibre Cement Board as per IS 14862:-ARMSTRONG/ SAINT GOBAIN (GYPROC)/EVEREST / VISAKA Industries Ltd
Material and labour for75 mm thick plain cement concrete 7.5 (Nominal Mix) using 40 mm graded stone aggregate as in sub base floor complete all as specified and as directed.
Material & Labour Glazed ceramic tiles 400x300x7 mm(Coloured) on vertical surfaces such as skirting, dados and riser to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete over 10mm thick screed bed vertical layer in CM (1:4)all as specified and as directed.
Material & Labour Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tile exceeding 0.18 Sqm and not exceeding 0.36Sqm , in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed layer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and as directed.
Material & Labour of vitrified ceramic tiles,double charged dark coloured shade, 10 mm thick of square/rectangular area of each tile exceeding 0.36 Sqm but not exceeding 0.42 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over 15mm thick screed bed layer in CM (1:4)complete all as specified and as directed.
Supply and fixing Powder Coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Supply and fixing of aluminium sliding window with powder coating (minimum thickness of powder coating 50 micron) including following components / specifications complete all as specified and as directed. (i) Two leaf glazed sliding shutter and one leaf gauged (fly proofing) sliding shutter. (ii) Opening of windows exceeding 0.90 Sqm but not exceeding 1.50 Sqm (iii) Thickness and weight per metre length of aluminium frame and section of shutter all as shown on drawing. (iv) All vertical/ horizontal joints shall be of extruded aluminium section so as to avoid any play between jointed members. (v) All other accessories such as jointing cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, etc. (vi) Rest all as specified in drawing no CESZ/2015/TD/007 Sheet no 1R/5, 2R/5, 3R/5, 4R/5 & 5R/5.
Supply and fixing of sheet glass 5 mm thick ordinary quality fixed to aluminum door & window in squares in each pane of required size complete all as specified and as directed.
Material and labour for solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing on vertical PVC fillet frame all as per specified on page no 162 of SSR Part-II complete all as specified and directed.
Material and labour for 5mm thick PVC sheet fillet frame of width 35mm for wall paneling and fixing on to wall to make PVC Frame all as per specified on page no 162 of SSR Part-II complete all as specified and directed.
Material and labour for Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
Material and labour for Mild steel mortice lock vertical type, 4 lever, size 100 mm complete all as specified and directed.
Material and labour for Veneered particle board exterior grade, solid core, general purposes type, with face veneers of type 'BB', prelaminated both side with decorative choice lamination fixed with screws to timber frame work complete all as specified and directed.
Material and labour for concealed point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, FRLSH through and including 20 mm PVC conduit & its accessories, cadmium screws fixed in concealed surface of wall/ceiling/false ceiling and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable FRLSH as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick laminated sheet for housing complete switch for the following Note :- Cutting chases and making good in walls shall be deemed to be included in the unit rate. One light/fan/bell point controlled by one way switch
One 3 pin socket outlet 5 amps on the same board with other switches
One 3 pin socket outlet 5 amps on the independent board
Material and labour for concealed point wiring complete with 4.00 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, FRLSH through and including 20 mm PVC conduit & its accessories, cadmium screws fixed in concealed surface of wall/ceiling/false ceiling and including 4.00 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable FRLSH as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick laminated sheet for housing 3 pin socket outlet 15 Amp independent:- Note :- Cutting chases and making good in walls shall be deemed to be included in the unit rate.
Supply and fixing of switch socket outlet 3 pin 6 Amps 230 volts flush type complete all as specified and as directed.
Supply and fixing of switch piano flush single pole one way 5 amps complete all as specified and as directed.
Supply and fixing switch socket outlet multipurpose 3 pin 15 Amps /5 Amps controlled by one switch complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 65x50mm three terminals complete all as specified and as directed.
Supply , Fixing & testing of Recessed/Surface LED ceiling light fitting 36 Watt of 600mm x 600 mm with LED lamp’s & driver and made of Metallic CRCA powder coated body with UV stabilized polycarbonate cover or toughen glass cover & high power LED’s as light source with LED fitting system lumen not less than 100% Lumen per watt and electronic driver with efficiency > 85% with inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD <10%, PF shall be > 0.95, colour temperature 5700±300 K), Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than three years. The fitting shall be tested LM 79 & 80 and test certificate shall be submitted from original manufacture including connection complete all as specified and directeddirected. Make : Model NoLCTLRP 24 FOCDL of Crompton Greaves or equivalent model of make list as given in PS as approved by GE.
Supply and fixing of sheet metal enclosure for MCBs to be used singal pole & nutral double door 12 Way 200 Amps rated busbar and including fixed with 25mm x 6 mm mild steel clamp of suitable length and including taking out old DB complete all as specified and as directed.
Supply and fixing of MCB SP of rating 6 to 32 Amps 240 V complete all as specified and as directed.
Supply and fixing MCB DP 40 to 63 amps 415 volts 10KA breaking capacity all as specified and as directed.
Supply and fixing of sub main wiring with two single core 6.0sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC conduit and accessories accessories including one single core 6.0sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
Material and labour for lamp holder insulated body with back plate for batten fittings with 10 Watt LED lamps complete all as directed
Earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connetced with earthing wire 4.0mm dia as earthing lead by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 5 of MES Schedule Part-I complete including testing on completion. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Supply and Fixing wall mounting fan 400 mm sweep, 2000 rpm, heavy duty PP blade,fixed on wall including necessary connecting PVC insulated flexible cable complete all as specified. Make Havells/ BAJAJ/ CROMPTON GREAVES/ ORIENT/ ALMONARD as approved by GE.
Supply, installation, testing and commissioning hi wall split units indoor/ outdoor type air conditioner electrical driven, single phase of capacity 2.00 TR with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter including electrical connection complete all as specified and as directed. Note :-(a) The quoted rate shall be deemed to include taking down existing AC, deposite to MES store old one, lifting, shifting, positioning at site of all the equipment, fittings, topping up of refrigerant, units installation, vibration isolators, and ancillary material as per manufacturer’s instruction. (b) Cordless remote control unit, drain pipe upto 4 m shall deemed to be included in the quoted rate. Make:- Carrier/Daikin/Hitachi /Bluestar/Voltas / Godrej/LG
Supply and fixing of Metal distribution box with clad plug and socket and including SPN-MCB control 2 pin & earth plug with socket , 20 A, 240 Volts universal type complete with one MCB 20 A SPN 240 volt complete all as specified and as directed. Make :- Cat No 5078 14 of Legrand or equivalent model of make list as given in PS as approved by GE.
Supply and installing voltage stabilizer having following features i.e. high power efficiency, intelligent time delay system, (3 mts +/-20 sec, ITDS) inrush current capability etc., for automatic operation single phase naturally air cooled indoor type and designed for input variation between 130 volts to 290 volts with out put voltage stabilized at 230 volts with accuracy of +/- 2.5% and of capacity 4 Amps complete all as specified and as directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core complete all as spd and directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out as in soft/loose soil.
Excavation in trenches not exceeding 1.50 m wide and exceeding 1.50 m and not exceeding 3.0 m in depth for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point.
Class designation 75 bricks, old size, flat, common clay laid in trenches across the trench as cable protection
Plain Cement Concrete M-7.5(Nominal Mix) using 40 mm graded stone aggregate as in foundation filling and mass concrete
Plain Cement Concrete M-10(Nominal Mix) using 20 mm graded stone aggregate as in coping, bed plates, wheel guard & other similar work etc. including weathering, slightly rounded or chamfered angles and throating and necessary form work complete
Sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified. Note :- Thickness of sand cushioning shall be the thickness after punning down.
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant and including high power LED's as light source with 110 Lumen per watt and electronic driver with efficiency > 95% including thermal management in multiple optics complete all as specified and as directed. Make:- Model No- LPTO-40-CDL of Crompton Greave / BGCL 40W LED WH of BAJAJ / LGTP06X040XC of Jaquaror equivalent model of make list as given in PS as approved by GE. Notes : (i) Warranty of complete LED luminaries fitting shall not less than four years and Life expectancy of LED's minimum 50,000 burning hrs,. (ii)The contractor shall be submitted the LM-79 third party NABL accredited lab test report and LM-80 test certificate and LED has to be stractured in the same sequence.
LED ballard light fitting 9 Watt, made of die cast aluminum wing shaped powder coated housing with UV stabilized opal acrylic cover including driver( >80% efficiency level & THD< 10%) , power factor shall be >0.95 and fixed on PCC/birck pillar with MS nut& bolt and including connecting up with suitable size of copper conductor cable from junction box complete all as specified and directed . Model No- LBLSN-10-CDL of Crompton Greave or equivalent model of make list as given in PS.
Supply and fixing in repair LED flood of 70Watt with LED lamp's & driver and made of pressure die-cast aluminium housing, heat resistant, IP 65/IP 66 road way luminaries with UV stabilized polycarbonate cover or toughen glass cover, & high power LED's as light source with 110 Lumen per watt and electronic driver with efficiency > 95% including thermal management in multiple optics complete all as specified and as directed Make:- Model No- LFL-70-CDL/60-M of Crompton Greave /BJFL 80W LED I of BAJAJ / LFLDSLM070XC of Jaquar or equivalent model of make list as given in PS .
Supply and fixing of MCB SP of rating 6 to 32 Amps 240 V complete all as specified and as directed.
Supply and fixing MCB DP 40 to 63 amps 415 volts 10KA breaking capacity.
Supply & fixing of transparent street light junction box of size 155 mm x 210mm x 92 mm made of high quality polycarbonate I IP-65 (Dust and power jet Proof according to IEC 60529) , shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II ) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper bus bar 25 x 5 mm -04 strip, one no MCB DP 6 Amps with locking arrangement suitable up to, 50 Sqmm cable etc complete all as specified and directed Make: HENSEL Cat No DK 1616G or equivalent model of BCH/LEGRAND/ SINTEX
LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 16 Sqmm x 4 Core
AJOY DUTTA CHOWDHURY AND CO
RAJIB GOSWAMI ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .