Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Technically Qualified |
| 2 | Accepted-Technical | Accepted-Technical Technically Qualified |
| 3 | Accepted-Technical 24A RABINDRA SARANI KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | Accepted-Technical Technically Qualified |
Tender Value
Refer Docs
EMD Value
₹11,494
Closing Date
4 Nov 2026, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE KLESD PWD
Kolkata Lok BhavanElectrical Sub-Division 2, Larkin Lane, Kolkata-700062
Electrical installation work for installation of Air conditioning system other electrical renovation work at East Ball room of Lok Bhavan Kolkata.
2026_WBPWD_5081330_1
WBPWD/AE-KLESD/NIQ-46/2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
LOK BHAVAN KOLKATA
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,494
Yes
23 Nov 2026
28 Oct 2026
6 Nov 2026
28 Oct 2026
4 Nov 2026
28 Oct 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . [Make:Legrand/ L&T/ ABB /Siemens/Crabtree]
8 way (4 + 24), Double door [CPWD(DSR) /2.5.2] | 1 | No | - | - |
| 2 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,
making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. [Make:Legrand/ L&T/ABB/Siemens/Crabtree]
200 A,36KA,FPMCCB [CPWD(DSR) /2.2.15] | 1 | No | - | - |
| 3 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and
commissioning etc. as required. (Make: Legrand/Siemens/ Crabtree/L&T as approved by E.I.C) [CPWD(DSR) /2.10]
32Amp Triple pole and neutral [CPWD(DSR) /2.10.5] | 4 | Nos | - | - |
| 3.1 | 63 Amp TP MCB [PWD /D6:7] | 4 | Nos | - | - |
| 4 | Supplying and fixing 415V, 125 Amp TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.[ Make: L&T/ Havells/ Siemens/Standard] | 1 | No | - | - |
| 5 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with
connections, testing and commissioning etc. as required. [CPWD(DSR) /2.19] | 6 | No | - | - |
| 6 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size.(Make:-Gloster/Polycab/Havells/RR Kable)
(4 core 70 sqmm) | 124 | Mtr | - | - |
| 7 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) [CPWD(DSR) /10.7.2] | 84 | Mtr | - | - |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 35 sq. mm and upto 95 sq. mm [CPWD(DSR)/10.1.2] | 20 | Mtr | - | - |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Above 35 sq. mm and upto 95 sq. mm [CPWD(DSR)/10.5.2] | 20 | Mtr | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_5191506.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .