Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H3₹1.5 Cr−₹4.3 L (2.84%)Accepted-AOC | ₹1.5 Cr−₹4.3 L (2.84%) | H3 | Accepted-AOC Awarded being lowest as per NIT |
| 2 | H1₹1.5 CrRejected-Finance | ₹1.5 Cr | H1 | Rejected-Finance Rejected being H1 bidder |
| 3 | H2₹1.5 Cr−₹1.5 L (1.00%)Rejected-Finance HOUSE NO 138 B HILL VIEW LANE NO 03 INDRA NAGAR SRINAGAR 190004 J K | SRINAGAR | JAMMU AND KASHMIR | 190004 | ₹1.5 Cr−₹1.5 L (1.00%) | H2 | Rejected-Finance Rejected being H2 bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical The unenlisted firm is not meeting the eligibility criteria wr to past experience of similar scope work and other parameters as listed in NIT at Para 8 (B). Hence , Not Recommended. |
| Sl No | Description | Qty | Unit | ALCO ENGINEERSPVT LTD H3 | m/s mohd saleem and co H1 | M/S Vivek Gupta and Co H2 |
|---|---|---|---|---|---|---|
| 1.00LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS | ||||||
| 2.00 | Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part -I brought forward from serial page No. 25 | 1 | Lump sum | 67,51,000 ₹67,51,000 | 71,50,000 ₹71,50,000 | 65,00,000 ₹65,00,000 Lowest |
| 3.00 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A'(Part-II Section-I) brought forward from serial page No. from 26 to 28 | 1 | Lump sum | 1,00,000 ₹1,00,000 | 54,820 ₹54,820 Lowest | 1,22,000 ₹1,22,000 |
| 4.00Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' (Part-II Section-II) | ||||||
| 4.01 | S&F LED smart Lamp, B22 type ,14 watt, complete all as specified and directed | 2 | Each | 200 ₹400 | 150 ₹300 Lowest | 300 ₹600 |
| 4.02 | Supply and Install of the electric water heater storage 25 Ltr capacity 5 Star rated of Stainless-Steel body vertical type glass lined of inner tank and heating element and having the wall mounting arrangement, thermostat, indicators and thermally insulated stainless steel tank of glass lined inside the tank and heating element, PTMT connection pipe of 15mm dia and mounting on wall with suitable size of anchor bolts with complete connection of water & testing and all as specified and directed.
Make Havells Puro Turbo DX/ Racold / Bajaj Calenta | 1 | Each | 14,000 ₹14,000 Lowest | 1,25,000 ₹1,25,000 | 20,000 ₹20,000 |
| 4.03 | Distribution board iron clad vertical DB double door with IP-43 protection and mechanical strength as IK-09 suitable for MCCB as incomer & MCB as outgoing 415V 3Phase 50Hz 4 Way complete with appropriate size of copper bus bar and neutral link complete with one MCCB TPN 4 Pole 415V 63 Amps rating, 16kA with adjustable thermal and adjustable magnetic release & as outgoing MCB SPN 40 amp - 02 Nos of the same make as of distribution board complete all as specified and directed | 1 | Each | 9,000 ₹9,000 Lowest | 10,000 ₹10,000 | 12,000 ₹12,000 |
| 4.04 | Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.25 metre deep below ground level ) with top edge of the plate not less than '1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as show in in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150 mm, 20mm bore Gl medium grade watering pipe, 15 mm bore light grade earth lead protection pipe up to main board, funnel with wire mesh, 40 mm thick RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including test on completion.
Note - The rate quoted include cost of min 7.5 metre earthing wire | 2 | Each Set | 6,500 ₹13,000 | 6,000 ₹12,000 | 5,000 ₹10,000 Lowest |
| 5.00 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 29. | 1 | Lumpsum | 20,000 ₹20,000 Lowest | 22,750 ₹22,750 | 25,000 ₹25,000 |
| 6.00 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' (Part-IV Section-I) brought forward from serial page No. 30. | 1 | Lumpsum | 1,10,000 ₹1,10,000 | 90,100 ₹90,100 Lowest | 1,00,000 ₹1,00,000 |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
8 Jul 2025, 6:00 pmClosed
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS, PIN 914133, C/O 56 APO
CWEK/TOKEN-131/874 EWS/2024-25 PROVN OF WATER SUPPLY SCHEME WSS AT PATHAHIRI GRN UNDER GE 874 EWS, JOB NO LXVII/02/AMWP/TREHGAM/2024-25
2025_MES_702677_2
CWEK/TOKEN-131/874 EWS/2024-25
Open Tender
Civil Works - Water Works
Lump-sum
270 days
GE 874 EWS
Class B and above and category a ii
7 documents required · 7 mandatory
₹1,000
GE 874 EWS
₹2.2 L
HQ 133 WORKS ENGRS
11 Sept 2025
13 Jun 2025
16 Jul 2025
13 Jun 2025
8 Jul 2025
25 Jun 2025
13 Jun 2025 - 16 Jun 2025
18 Jun 2025
Amount
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part -I brought forward from serial page No. 25
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A'(Part-II Section-I) brought forward from serial page No. from 26 to 28
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' (Part-II Section-II)
S&F LED smart Lamp, B22 type ,14 watt, complete all as specified and directed
Supply and Install of the electric water heater storage 25 Ltr capacity 5 Star rated of Stainless-Steel body vertical type glass lined of inner tank and heating element and having the wall mounting arrangement, thermostat, indicators and thermally insulated stainless steel tank of glass lined inside the tank and heating element, PTMT connection pipe of 15mm dia and mounting on wall with suitable size of anchor bolts with complete connection of water & testing and all as specified and directed. Make Havells Puro Turbo DX/ Racold / Bajaj Calenta
Distribution board iron clad vertical DB double door with IP-43 protection and mechanical strength as IK-09 suitable for MCCB as incomer & MCB as outgoing 415V 3Phase 50Hz 4 Way complete with appropriate size of copper bus bar and neutral link complete with one MCCB TPN 4 Pole 415V 63 Amps rating, 16kA with adjustable thermal and adjustable magnetic release & as outgoing MCB SPN 40 amp - 02 Nos of the same make as of distribution board complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.25 metre deep below ground level ) with top edge of the plate not less than '1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as show in in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150 mm, 20mm bore Gl medium grade watering pipe, 15 mm bore light grade earth lead protection pipe up to main board, funnel with wire mesh, 40 mm thick RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including test on completion. Note - The rate quoted include cost of min 7.5 metre earthing wire
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 29.
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' (Part-IV Section-I) brought forward from serial page No. 30.
Lump sum price worked out by the contractor for ROAD/PATH WORKS as listed in Schedule 'A' Part-V brought forward from serial page No.31
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule 'A' Part-VI brought forward from serial page No. 32.
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS listed in Schedule 'A' Part-VII brought forward from serial page No. 33 to 34
Lump sum price worked out by the contractor for EXTERNAL WATER WORKS as listed in Schedule 'A' (Part-VII Section-II)
M&L for Cutting of existing steel tubing for alteration or additions and insertion of Tee 40x40x25mm, union, socket all as specified and directed.
M&L for Cutting of existing steel tubing for alteration or additions and insertion of Tee 50x50x25mm, union, socket all as specified and directed.
M&L for Cutting of existing steel tubing for alteration or additions and insertion of Tee 25x25x20mm, union, socket all as specified and directed.
M&L for Cutting of existing steel tubing for alteration or additions and insertion of Tee 80x80x40mm, union, socket all as specified and directed.
M&L for Cutting of existing steel tubing for alteration or additions and insertion of Tee 80x80x50mm, union, socket all as specified and directed.
M&L for construction of valve pit of size 90 cmX90 cmX120 cm internal dimensions brick construction including all excavation and earth work in har/loose soil returning filling in disposal of surplus spoil to a distance not exceeding 50 m and depositing where directed PCC in foundation of the mix (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) brick masonry in cement mortor (1:4) rendering 12 mm thick in cement mortor (1:4) internally finished even and fair and pointing flush externally as the work proceeding in the same mortor mild steel 50x6 mm frame MS sheet cover of 3.15 mm thick with handle and locking arrangment painting all the exposed MS work with two coat of synthetic enamel paint of the make as approved all the MS embedded in PCC with two caots of black bituminous paint complete all as specified and shown on drawing.
Non-return valve heavy duty of size 80 mm bore, ISI Marked, flanged ends including suitable nut bolts, washers, packing sheet, etc complete with necessary arrangements for fixing complete all as specified and directed by Engr-in-Charge.
Non-return valve heavy duty of size 50 mm bore, ISI Marked, flanged ends including suitable nut bolts, washers, packing sheet, etc complete with necessary arrangements for fixing complete all as specified and directed by Engr-in-Charge.
Supply and fixing foot valve size 80 mm complete all as specified and directed.
Supply and fixing foot valve of size 50 mm complete all as specified and directed.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS listed in Schedule 'A' Part-VIII brought forward from serial page No. 35 to 37
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' (Part-VII Section-II)
M&L for HT lightening arrester metal oxide type (gapless) heavy duty single pole suitable for rated system volume of 12KV and working rated system voltage of 12 KV and working rated arrestor voltage of 9 KV with normal discharge current of 10 KV all as per IEC 99.4, effectively earthed all as specified and directed. Note: Test certificate for lightning arrestor shall be supplied without which no payment shall be admissible, all as specified.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level , connecting to the galvanised earth strip of size 32 mm X 6 mm by means of bolt, nuts, check nuts and washer of galvanised iron and galvanised iron and 32x6mm GI earth strip protected by provision of galvanised iron pipe medium grade, 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) type B-1 using 20mm graded crushed aggregates reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 40 x 40 x6 mm and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made to shape 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal test point phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No. 3 of SSR 2010 Part-I and connection to earth test point all as specified and testing on completion all as specified and directed . Note : The quoted rate of earthing shall be deemed to include the cost of 7.5 m long galvanised iron strip 32x6mm and protection pipe of 40mm bore medium grade any variation in length shall be adjusted through deviation order based on SSR rates adjusted with quoted rates
Supply, installation, testing and commissioning distribution transformer step down 11//0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% continuous rating of 30 KVA outdoor type confirming to IS 1180, EE level-II with and including the following: (a) Lifting lugs/ hooks for transformer and tank (b) Earthing terminal rating and diagram plate (c) Air release device (d) Oil filling inlet pipe with plug (e) Drain outlet pipe with brass gate valve with dummy plug (f) Conservator with level gauge (g) Silica gel breather (h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335 (j) Type of connection: Delta/Star (k) Type of cooling: ONAN (l) Vector Group: DYN 11 (m) Type of connecting arrangement: Cable termination boxes on both HT and LT side (n) Temperature rise over an ambient of 50 degree centigrade maximum (o) All necessary arrangements with devices for measuring the temperature of core, winding and oil (p) In addition to the above all standard fittings shall be provided as per IS norms
M&L for cable route indicator showing MES UG HT cable/ LT Cable and arrow of cable with arm made up of CI with suitable elliptical shape and fixed with MS rod 12mm dia 120 mm long and embedded in and including PCC 1:3:6 type C2 using 40 mm grade stone using C2 40 mm grade stone aggregate of size 30 x 30 x 30 mm in ground to be embedded not less than 60 cm depth complete all as specified and directed.
Supply, Installation, testing and commissioning of centrifugal pump set with bronze impeller having minimum discharge of 355 LPM at head 75 mtr coupled with suitable capacity of electric motor 415 volts 3 phase 50Hz having 2900 RPM Monoblock and having power capacity not less than 20 HP, fixed on MS channel 100mm duly grouted with suitable size of nuts and bolts in PCC foundation and starter as per manufacturers recommendation including material and labour for making electric connection with suitable size of three core stranded XLPE cable through laid in cable duct /trenches/pole from starter to electric motor of pumping set and necessary water supply connection for suction and delivery side of pump set with suitable size of medium grade GI pipe complete upto NRV all as specified and directed.
Supply, Installation, testing and commissioning of centrifugal pump set with bronze impeller having minimum discharge of 708 LPM at head 19 mtr coupled with suitable capacity of electric motor 415 volts 3 phase 50Hz having 2900 RPM Monoblock and Having power not less than 5 HP, fixed on MS channel 100mm duly grouted with suitable size of nuts and bolts in PCC foundation and starter as per manufacturers recommendation including material and labour for making electric connection with suitable size of three core stranded XLPE cable through laid in cable duct /trenches/pole from starter to electric motor of pumping set and necessary water supply connection for suction and delivery side of pump set with suitable size of medium grade GI pipe complete upto NRV all as specified and directed.(5HP)
Supply, Installation, testing and commissioning of centrifugal pump set with bronze impeller having minimum discharge of 190 LPM at head 20 mtr coupled with suitable capacity of electric motor 415 volts 3 phase 50Hz having 2900 RPM Monoblock and Having power not less than 2 HP, fixed on MS channel 100mm duly grouted with suitable size of nuts and bolts in PCC foundation and starter as per manufacturers recommendation including material and labour for making electric connection with suitable size of three core stranded XLPE cable through laid in cable duct /trenches/pole from starter to electric motor of pumping set and necessary water supply connection for suction and delivery side of pump set with suitable size of medium grade GI pipe complete upto NRV all as specified and directed.
Supply and installation of DOL starter for 2 HP motor at site including all electrical connection , complete all as specified and directed by engr-in-charge.
Supply, installation, testing and commissioning of silent diesel engine driven generating set developing BHP water cooled of capacity 40 KVA (32 KW), 415 volts, 0.8 power factor, mounted on common base frame coupled, 1500 RPM along with sound proof enclosure (acoustic enclosure) design for reducing the sound level to 75 dBA IS 10001/1002 part 10 as per approved CPCB-IV norms and as per GSR 371(E) dated 17.05.2002 with silencer pipe and silencer muffler covered with asbestos rope 25mm thick independently supported from engine to outside of pump house upto 1.00 mtr cold start kit, battery start with suitable size of standard cable for connection from DG set to panel board, DG Set shall be capable of operating in temperature range of (-) 20°C to (+) 35°C with and including the following :- (a) PRIME MOVER. Vertical diesel engine of suitable capacity having 56 HP water cooled (Radiator mounted) closed circuit as per BS-5514 or ISO-3046 direct injection type with turbo charger. The diesel engine shall be capable of running 24 hrs continuously with 10% over loading for one hour in every 12 hours. Engine shall be equipped with all standard fitting as per manufactures recommendations and mounted on common base platform through flexible coupling with following accessories:- Contd......./-
(i) RPM cum hour meter. (ii) Battery charging ammeter. (iii) Ignition key and starting with push button switch. (iv) Lubrication oil pressure gauge. (v) Mechanical Governor controlling. (vi) Toggled switch for idle running. (vii) Oil temp gauge. (viii) Safety control (Trip) for the following :- (aa) Low lubricating oil pressure. (ab) Over speed. (ix) Lub oil coolant heater to avoid freezing. (x) 12/24 volts (as per manufactures recommendation/design) starting equipment comprising of all followings : (aa) Battery charging alternator with inbuilt regulator 12 Volts and of Ah as recommended by manufacturer of DG set, battery -01 No, (make: Exide/Amaron or as recommended by manufacturer) Batery shall be maintenance free type. (ab) Self starter motor assy of suitable capacity. (ac) Battery leads (copper stranded cable) of suitable size with brass thimbles and terminals. (xi) Cold starting kit.
((B) ALTERNATOR : Alternator of capacity 40 KVA/32 KW, 415 volts, 50 C/S, 1500 RPM, 0.8 Power factor, self-excited, self-regulated, screen protected with slef excited field brush rotating fixed designed to be coupled with above engine through closed coupling. The Alternator shall be conform to IS 4700 of BS-5514, ISO-3046. (C) MANUAL CONTROL PANEL: The control panel will be fabricated out of 16 SWG MS sheet, panel, Detachable cable gland plates shall be provided. The panel shall be equipped as follows: - (i) Moulded case circuit breaker of suitable capacity - 01 No (ii) Aluminium busbars/copper cables of suitable capacity provided withterminals - 03 Nos (iii) Current Transformer of suitable ratios - 03 Nos (Set of three) (iv) Set of instrument MCBs -01 Set (v) Microprocessor based controller controlling various mechanical and electrical protection with display and indication of electrical and mechanical parameters:- (aa) display Parameters (i) Electrical Parameters: Phase voltage, line current, frequency, average voltage, average current, KW, KWH, KVA, KVAR, Power factor. Contd..
(ii) Mechanical Protections: Lube oil pressure, coolant temperature (for liquid cooled engines), cylinder head temperature (for air cooled engines), Engine speed, fuel status, engine run hours, Battery voltage. (ab) Protection: - (i) Electrical Protections: Under/Over voltage , under/over frequency, phase failure or phase erases, over current, over KW. (ii) Mechanical Protections: Under/Over speed, low lube oil pressure, high engine coolant temperature (for liquid cooled engines), Belt failure (for air cooled engines) low fuel level alarm. (D) OTHER FITTINGS: (i) Battery charger: - Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge the battery at all time wherever electric supply given to battery charger through control panel or electric power point. (ii) Inbuilt Fuel Tank: - Inbuilt fuel tank of suitable capacity for 12 hours running as per manufacturer recommendation fitted inside acoustic enclosure with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc.
Notes: - (a) DG set shall be supplied alongwith with original acoustic enclosure of the manufacturer's suitable for 40 KVA set as per CPCB-IV Norms. (b) Pre commissioning test of DG set shall be carried out by the rep of Accepting Officer within overall cost quoted. (c) Foundation of DG set shall be as per design of manufacturer and cost thereof shall be included in overall cost quoted. (d) Complete Dg set shall be included in overall cost quoted. Note:- Rate for item No 12.09 to 12.12 shall be quoted at item No 12.09
Supply and Fix onload change over switch 415 V in sheet metal enclosure 4 pole of capacity 125 Amp complete all as specified and directed by Engr in charge .
Supply and fixing of starter LT Panel Board, indoor type of suitable size as per relevant IS, mounted on angle iron legs of size 50x50x6mm imbedded in PCC 1:2:4 block type B-2 (using 40 mm graded aggregates) at pump house, floor mounting, dust and vermin proof, factory made (CPRI approved), fabricated out of 2 mm thick CRCA sheet suitable for 3 Phase, 415 Volt, 50HZ AC Supply, busbar chamber with aluminium busbar of suitable amp rating for 3 Phase and 4 wire system duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25 mm x 4mm at bottom inside panel board with two earth terminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in grey colour all as specified & directed, (i) MCCB TP neutral link 415 volt 50 Hz, AC 100 Amps 36 KA with adjustable thermal magnetic release for over load & short circuit protection - 01 No as Panel Incomer. (ii) MCCB TP neutral link 415 volt 50 Hz, AC 63 Amps 16 KA with adjustable thermal magnetic release for over load & short circuit protection - 04 Nos. (iii) MCB TP neutral link 415 volt 50 Hz, AC 63 Amps 16 KA with adjustable thermal magnetic release for over load & short circuit protection - 02 Nos.
Supply, Installation, testing and commissioning of Chlorine Dosing Systems of capacity 20 LPH consisting of the following equipment and services, with necessary PCC foundation of 30 cm height, length and width as required and Copper/ Bronze/ stainless steel equipment specification plate consisting of each of the following equipment specifications as well as operation directions.:- (a) Agitator system comprising of 0.5 HP motor and suitable mixer capable of agitating the Bleaching powder solution of upto 5% chlorine (15kg Bleaching powder per 100 litres water), with the mixer compatible with tank as given below and made of corrosion proof metallic components, with digital timer (with auto cutoff) display measuring time of agitation, timer settings, etc., all along with associated mechanical and electrical fittings and accessories. The agitator system will also have a system for filtering undissolved solids from the inlet to the dosing pumps, all as directed by engineer in charge. (b) Storage Tank and Agitator Tank made of Fibre Reinforced Plastic or material with equivalent toughness and strength with hot forge joined joints, of capacity 200 litres, with suitable mounts for agitator and suitable base to be joined with skids, with drain pipes, clearance pipes for sedimented undissolved solids, inlet water pipeline, etc., and lid of same material, as directed by engineer in charge.
(c) Dosing pump of capacity of 20 LPH, made of hard plastic/ corrosion proof metallic components, with digital panel and adjustment (in increments of 0.1 LPH) for varying LPH output, with memory setting, digital backlit display, autocleaning feature, deposition proof inner body, filter for undissolved solids at the inlet, appropriate pipeline for inlet and outlet, connection with water supply plumbing for outlet pipes, etc., all as directed and specified by engineer in charge (d) Control panel with sheet metal enclosure having sufficient size bus bars for one chlorine dosing system, mounted on skids as given below, having digital meters for measuring electrical parameters such as input voltage, Amperage and wattage, with necessary control knobs, on off switches, RCBO of suitable size for main inlet, MCBs of suitable sizes for each instrument (such as agitator, Dosing pump, etc,) fixed on the skid or laid with PCC foundation as directed, all water and dust resistant upto IP 65, all as directed by engineer in charge. (e) Skid of suitable size, made of corrosion proof metallic structure, heavy duty design, with wheels attached/ laid in PCC foundation (as directed), housing all above equipment, properly electrically insulated.
Lump sum price worked out by the contractor for SITE DEVELOPMENT & EARTHWORK as listed in Schedule 'A' Part-IX brought forward from serial page No.38 to 39
M/S Vivek Gupta and Co (BID ID -3342406)
ALCO ENGINEERSPVT LTD (BID ID -3342580)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .