Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.7 LAccepted-AOC SP 52 MPPGCL COLONY BIRSINGHPUR DISTT UMARIA 484 552 M P | BIRSINGHPUR | UMARIA | MADHYA PRADESH | 484552 | L1 | Accepted-AOC Stood L1 |
| Sl No | Description | Qty | Unit | K K POWER CONSTRUCTION L1 |
|---|---|---|---|---|
| 1.00COAL CIRCUIT | ||||
| 1.01 | Complete Overhauling of Coal Mills | 10 | Nos. | 3,06,210 ₹30,62,100 Lowest |
| 1.02 | Complete Overhauling of Raw Coal Feeder including COC System | 10 | Nos. | 11,977 ₹1,19,770 Lowest |
| 1.03 | Replacement of Coal Feeder Chute | 9 | Nos. | 5,681.7 ₹51,135.3 Lowest |
| 1.04 | Complete Coal Burner Assembly Replacement | 1 | Nos. | 8,496 ₹8,496 Lowest |
| 1.05 | Repair & replacement of Guide pipes of Oil Burner/ Scanner | 4 | Nos. | 3,304 ₹13,216 Lowest |
| 1.06 | Replacement of Journal head Assembly with Grinding Roll | 3 | Nos. | 17,700 ₹53,100 Lowest |
| 1.07 | Repair, Patching, Hardfacing/Replacement of MDV | 4 | Nos. | 1,333.4 ₹5,333.6 Lowest |
| 1.08 | Fabrication of Journal Head Liner Support Assembly | 1 | Nos. | 2,360 ₹2,360 Lowest |
| 1.09 | Repair/ Replacement of Multi Port Outlet Assembly. | 2 | Nos. | 2,619.6 ₹5,239.2 Lowest |
Tender Value
₹69.2 L
EMD Value
₹1.4 L
Closing Date
12 Apr 2023, 3:30 pmClosed
SE (works)
O/o Addl CE (P and W) SSTPP, MPPGCL, Dongalia
Work contract of Preventive /Breakdown maintenance of Boiler Non Pressure Part of Unit- 1 AND 2, 2X600MW, SSTPP, MPPGCL, Dongalia
2022_MPPGC_239606_1
WT-1907
Open Tender
Miscellaneous Works
Item Rate
365 days
O/o Addl CE (P and W) SSTPP, MPPGCL, Dongalia
Please refer Tender documents.
17 documents required · 17 mandatory
₹2,000
Yes
₹1.4 L
Yes
11 Oct 2025
22 Feb 2023
17 Apr 2023
22 Feb 2023
12 Apr 2023
22 Feb 2023
COAL CIRCUIT
Complete Overhauling of Coal Mills
Complete Overhauling of Raw Coal Feeder including COC System
Replacement of Coal Feeder Chute
Complete Coal Burner Assembly Replacement
Repair & replacement of Guide pipes of Oil Burner/ Scanner
Replacement of Journal head Assembly with Grinding Roll
Repair, Patching, Hardfacing/Replacement of MDV
Fabrication of Journal Head Liner Support Assembly
Repair/ Replacement of Multi Port Outlet Assembly.
Replacement /Rotation of Pipe (Transition Piece) above MDV
Replacement/Reversal of Orifice or replacement of victaulic coupling in P.F.Pipe lines
Servicing/Rectification of Feeder Intet Gate, Jamming of Bunker Outlet Gate
Replacement of Worm Shaft Bearing
Replacement of Worm Shaft Oil Seal
Replacement of Main Vertical Shaft Oil Seals
Servicing of Mechanical Face Seal
Repair / Replacement of Air Port Assembly
Servicing of Rollar Journal Assembly
COC Shaft/Sprocket/Chain (Repair/Replacement)
Replacement of Bowl Hub Cover
Alignment of Mill Motor with Gear Box
Replacement of Geared Coupling or Bibby Coupling
Preparation of Quick Erect Scaffolding System (Cup lock System)
Replacement of ceramic lined coal pipe bends /Mill outlet Elbow(MOE)
Replacement of Journal Stop Bush Bolt/Spring Stud bearing(wear sleeve ) of journal compresson spring
Repairing of coal pipe/PF Bends//MOE/FIE
Replacement of straight P.F pipe with or without collar.
Painting of Coal Mill/Support Structure, Gearbox, Heat Exchanger etc.
Servicing of RCF Main drive gearbox
Removal and refixing of burner panel air seal plate with fasteners
Cleaning of Mill Gearbox Housing and coolers
Online Empty,cleaning of raw coal bunker
Replacement of Inner cone drum section
Servicing/Replacement of classifier assembly
Replacement/Repairing & Rotation of center feed pipe upper and lower
Servicing of Pinion Shaft assembly
Repairing and resetting of bottom insulation cover plate of coal mill reject chamber
Repairing/Replacement of diversion plate inside coal reject chamber
Replacement/Servicing of Labyrinth seal
FAN CIRCUIT
Servicing of ID Fan
Inspection & Servicing of RTL 10" Dodge Sleeve Bearing
Internal, Inspection and Cleaning of Fan
Alignment of ID Fan with motor
Maintenance of Seal Air Fans
Removal and Refixing of Impeller
Servicing of Fan bearing and Coupling Replacement
Alignment of Seal Air Fan with motor
Maintenance of FD/PA Fans
In-Situ Replacement of Grooved Ring/Seal (Actuator End)
Replacement of Grooved Ring/Seal (Driving End)
In-Situ Replacement of Counter Weight & Lever Assembly of Blade Bearing Assembly
Alignment of FD /PA fan with Motor
Repair of Steel Structures Welding of Steel Plate (6 to 20 mm)
Replacement of Bracing Pipes/Protective Angles Inside Duct
Replacement of Beams / Channels inside Ducts
ROTORY AIR PRE HEATER ASSEMBLY
MAINTENANCE OF SEALING SYSTEM OF AIR PREHEATERS
Leveling of Axial Sector Plate
Leveling of HE Radial Sector Plate
H.E.Radial Seals Repair/Replacement & Setting
In-Situ condition repair of Sector Plates
MAINTENANCE OF DRIVE SYSTEM AIR PRE HEATER
Overhauling of Drive Gearbox of Air pre heater
MAINTENANCE OF SOOT BLOWING SYSTEM AIR PRE HEATER
Servicing of Soot Blower Gearbox
Replacement of Lance Tubes & Protection Cover
ELECTROSTATIC PRECIPITATOR (ESP)
Internal Cleaning of ESP Fields & Hoppers
Alignment of Emitting frames
Replacement/Repairing of rapping hammers of CERM/EERM/GDRM
Replacement of Support insulators
Replacement of Support insulators
Repair/Replacement of GD screen
Repair of ESP manhole door
Repair of ESP hoppers without steel
MAINTENANCE OF DAMPERS AND GATES
Cleaning, Inspection & Seal Replacement of Dampers
Servicing of Dampers
Servicing of Guillotine Gates
Servicing of Actuator Gear Box Assembly
Replacement of Eroded /Damaged Damper
Fabrication & Replacement of Damper Seals
Repair /Servicing of Seal Blowers
IDLE CHARGE
Idle charges per month
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .