Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC | L1 | Accepted-AOC Awarded lowest bidder (L1) | |
| 2 | L2₹45.7 L+₹81,279.20 (1.81%)Rejected-AOC | L2 | Rejected-AOC Being Second lowest (L2) | |
| 3 | L3₹46.8 L+₹1.9 L (4.24%)Rejected-AOC | L3 | Rejected-AOC Being Third lowest (L3) | |
| 4 | L4₹47.8 L+₹2.9 L (6.51%)Rejected-AOC 00 00 BAIRIYA NEAR KALI MAA MANDIR BALLIA UTTAR PRADESH 277502 | BALLIA | UTTAR PRADESH | 277502 | L4 | Rejected-AOC Being Fourth lowest (L4) | |
| 5 | L5₹47.9 L+₹3.0 L (6.72%)Rejected-AOC 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L5 | Rejected-AOC Being Fifth lowest (L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
26 Dec 2019, 6:00 pmClosed
GERD PASHAN PUNE
GERD PASHAN PUNE
Repair to utility services including internal electrification at ganeshkhind Pune
2019_MES_302998_1
GERD/PSN/TOKEN/42 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
All as per tenderdocuments
8 documents required · 8 mandatory
₹500
Yes
GERD PASHAN PUNE
₹90,000
Yes
17 Feb 2020
2 Dec 2019
31 Dec 2019
3 Dec 2019
26 Dec 2019
20 Dec 2019
3 Dec 2019 - 16 Dec 2019
Amount
Taking down carefully Copper aluminium point wiring (light, Fan, Exhaust Fan, Bell, socket or power point) complete including fixture and fitting such as switches, sockets, power socket, bell, bell push, light fittings, regulator, bracket holder, boards and making good disturbed surfaces of wall and ceiling etc complete all as specified and directed.
Taking down carefully unserviceable sub main wiring including conduit/casing patti etc complete all as specified and directed.
Taking down unserviceable DBs any type / size carefully disconnecting and making good disturbed surfaces complete all as specified and directed.
Taking down unserviceable MCCB/ MCB SP/SPN/Isolator of any rating and size complete all as specified and directed.
Material and Labour for Point wiring complete with and including 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FRLS grade with and including multistranded copper conductor ISI marked drawn through in existing concealed / surface PVC/Steel conduit and accessories and existing mild steel pressed steel terminal box and replace laminated sheet 3mm thick for mounting of switches, socket regulator etc including 1.5 Sqmm FRLS PVC insulated unsheathed cable multistranded copper conductor and connecting to earth dolly for light, Fan, Plug and bell complete all as specified and directed. (a) One light point controlled by one 5 Amps one way switch.
(b) One light point controlled by two Two way switch
(c) One ceiling Fan, Exhaust Fan point controlled by one 5 Amps switch.
(d) One bell/buzzer point controlled by one bell push button on independent board.
(e) One 3 Pin 6 Amps socket point on the independent board.
(f) One 3 pin 6 Amp socket point on the same board with other switch.
All as per above item No-5 here in before but with and including 2.5 Sqmm FRLS PVC cable for 15 Amp switch socket out let point on independent board including 1.5 Sqmm FRLS PVC insulated unsheathed cable multistranded with and including copper conductor earthing continuity conductor complete all as specified and directed.
Material and labour for Point wiring complete with and including 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FRLS grade with and including multistranded copper conductor ISI marked drawn through and including PVC casing and caping fixed on surface wall/ceiling and including pressed steel terminal box, grouted in wall and the 3mm thick terminated sheet top cover for mounting of switches, sockets regulators etc including 1.5 Sqmm FRLS PVC insulated unsheathed cable multistranded with and including copper conductor and connecting to earth dolly for light, fan, plug and bell complete all as specified and directed. (a) One light point controlled by one 5 Amps one way switch.
(b) One light point controlled by two way switch
(c) One ceiling Fan, Exhaust Fan point controlled by one 5 Amps switch.
(d ) One bell/buzzer point controlled by one bell push button on independent board.
(e) One 3 Pin 6 Amps socket point on the independent board.
(f) One 3 pin 6 Amp socket point on the same board with and including other switch.
All as per above item No-12 here in before but with and including 4 Sqmm FRLS PVC cable for 15 Amp switch socket out let point on independent board including 2.5 Sqmm FRLS PVC insulated unsheathed cable multistranded with and including copper conductor earthing continuity conductor complete all as specified and directed.
Material and Labour for point wiring with and including FRLS PVC insulated sheathed copper conducter of size 1.5 Sqmm (nominal area) with and including multistranded copper conductor drawn through in PVC conduit including concealing conduit in wall/floors etc. medium grade of suitable size with and incluidng all fittings and accessories including cutting chases in wall for fixing rigid PVC conduit and MS galvanised shunk type box covered with and includng laminated PVC sheet fixed with and including brass screw of suitable size for housing/mounting of switches/sockets including 1.5 Sqmm FRLS PVC insulated sheathed multistandard copper conductor for one light /fan contineous earth wire connected to common earth dolly for one light/fan point control by one switch and making good the distributed surfacess completely matched and finished with existing surfacess including painting of walls etc complete all as specified and directed. (a) One light point controlled by one 6 Amps one way switch
(b) One ceiling Fan, Exhaust Fan point controlled by one 6 Amps switch.
(c) One bell/buzzer point controlled by one bell push button on independent.
(d) One light point controlled by 2 Nos ,6 amps Two way switch.
(e) One 3 pin socket out let 6 Amp point on independent board
(f) One 3 Pin socket out let 6 Amp point on the same board with and including other switch.
All as per above item No-19 here in before but with and including 4 Sqmm FRLS PVC cable for 16 Amps switch sockets out let point on independent board including 2.5 Sqmm FRLS PVC insulated unsheathed cable multistranded with and including copper conductor earthing continuity conductor complete all as specified and directed.
Material and Labour for Rigid non-metallic PVC conduit 25mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
Material and Labour for Rigid non-metallic PVC Junction box (1 to 4 way) complete all as specified and directed.
Material and Labour for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall complete all as specified and directed.
Supply and fix switch piano flush button type , singlepole one way 5 Amps complete all as specified and directed.
Supply and fix switch piano flush button type , single pole two way 5 Amps complete all as specified and directed.
Supply and fix Bell push flush type SP 5 Amps complete all as specified and directed.
Supply and fix switch socket combination out let 5 pin 6 Amps flush type complete all as specified and directed.
Supply and fix switch socket out let 2 in 1, 3 pin 5 and 16 Amps flush type Universal complete all as specified and directed.
Supply and fix ceiling rose ,3 phase ,PVC polycarbonate ,insulated body complete all as specified and directed.
Supply and fix stepped type elctronic fan regulator 240 V 50 HZ , 100Watts flush type suitable for 1200mm/1400mm sweep ceiling fan complete including connection and dismantling of unserviceable regulator complete all as specified and directed.
Supply and fix call bell (Ding Dong) 240 V, 50 Hz complete all as specified and directed.
Material and Labour for lamp holder pendant/angle type insulated body with and including back plate complete all as specified and directed.
Supply and fix in repair tube light batten 36w/40w on existing pole/wall with and including new batten for LED light fitting with and including polycarbonate housing and integrated electronic driver suitable for 18w/20 watts LED tube rod, with and including necessary braket,clamps ,including bolts, nuts and washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. Make-Havells Cat No LUMILINEBS20WLED840SPCWH Or equivalent make of PHILIPS/WIPRO/CG/Bajaj
Supply and fix in repair Tube light batten 36 W/40 W on existing pole/wall with and including new batten for LED light fitting with and including aluminium housing and integrated electronic driver suitable for 18W/20 watts LED tube rod, with and including necessary braket,clamps ,incl. bolts, nuts and washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. Make-Havells Cat No LUMILINEPLUSBS20WLED865SPCSS Or equivalent make of PHILIPS/WIPRO/CG/Bajaj
Supply and fix in repair Tube rod 36W/40 W on existing fittings on pole/wall with and including new LED tube light 20 watt ,double side connection suitable for installation in existing T8 with and including G13 lamp holder and integrated electronic driver etc complete all as specifed and directed by Engineer-in-charge. Make-Havells Cat No CRYSTAL1213T8DSTL20WLED865SGLASS Or equivalent make of PHILIPS/WIPRO/CG/Bajaj
Supply and fix in repair Tube rod 36 W/40 W on existing fittings on pole/wall with and including new LED tube light 20W /18 watt ,double side connection suitable for installation in existing T 5 fitting with G5 lamp holder and out side electronic driver etc complete all as specifed and directed by Engineer-in-charge. Make-Havells Cat NoTITANIASLEEK1149T5DSTL18WLED865SPC Or equivalent make of PHILIPS/WIPRO/CG/Bajaj
Supply and fix in repair surface mounting round downlight LED 12 watt luminarie complete fitting with and including all fixing arrangement complete all as specified and directed by Engr-in-Charge. Make- Havells Cat No-EDGEPRORDDLR12WLED840S Or equivalent make of PHILIPS/WIPRO/CG/Bajaj
Supply and fix in repair LED security light fitting 20 watt with and including pressure dia cast housing, prismatic, polycarbonate diffuser and IP65 protection including 0.6 meter long 20mm/25 mm (as per manufacturer standard) dia GI Pipe in 45 degree bend shape and necessary clamping devices required at site complete all as specified and directed by Engr-in-Charge. Make-Havells Cat No ENDURAPEARLSL20WLED757SASYTOPC Or equivalent make of PHILIPS/WIPRO/CG
Material and Labour in repair for Sub main wiring complete with and including 2 runs of 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade with and including multistranded copper conductor ISI marked drawn through existing concealed PVC/Steel conduit and including 1 run of 2.5 Sqmm FRLS PVC insulated unsheathed copper conducter with and including multistranded copper conductor as earth continuity complete all as specified and directed. Note : Two runs of copper conducter and one run of earth copper conducter shall be measured as one length.
Material and Labour in repair for Sub main wiring complete with and including 2 runs of 2.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade with and including multistranded copper conductor ISI marked drawn through PVC cassing and capping / PVC conduit accessories fixed on surface/wall celing etc including provision of 1 run of 1.5 Sqmm FRLS PVC insulated unsheathed cable with and including multistranded copper conductor as earth continuity complete all as specified and directed. Note : Two runs of copper conducter and 1 runs of earth copper conducter shall be measured as one length.
Material and Labour in repair for Sub main wiring complete with and including 2 runs of 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade with and including multistranded copper conductor ISI marked drawn through existing concealed PVC/Steel conduit and including 1 run of 4 Sqmm FRLS PVC insulated unsheathed copper conducter with and including multistranded copper conductor as earth continuity complete all as specified and directed. Note : Two runs of copper conducter and one run of earth copper conducter shall be measured as one length.
Material and Labour in repair Sub main wiring complete with and including 2 runs of 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade with and including multistranded copper conductor ISI marked drawn through and including PVC rigid conduit/casing capping and conduit accessories fixed on surface/wall celing etc including provision of 1 run of 4 Sqmm FRLS PVC insulated unsheathed cable with and including multistranded copper conductor as earth continuity complete all as specified and directed. Note : Two runs of copper conducter and one run of earth copper conducter shall be measured as one length.
Supply and fix in repair VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and metal door including connection with and including aluminium thimbles as required complete all as specified in Cat No-607913 of Legrand or equivalant of Havells,Standard,Indo Asian complete all as specified and directed.
Supply and fix in repair sheet metal enclosure MCB distribution board Single pole and neutral (SPN) 240 volts 4 way with and including IP-43 IK-09 protection with and including metal door complete with and including appropriate size bus bar and neutral link complete all as specified in Cat No-607710 of Legrand or equivalant of Havells,Standard,Indo Asian complete all as specified and directed.
Supply and fix in repair sheet metal enclosure MCB distribution board. Single pole and neutral (SPN) 240 volts 8 way with and including IP-43 IK-09 protection with and including metal door complete with and including appropriate size bus bar and neutral link,all as specified in Legrand Cat No-607711 of Legrand or equivalant of Havells,Standard,Indo Asian complete all as specified and directed.
Supply and fix in repair sheet metal enclosures DB's 2 way SPN 240 V IK-08 all as specified in Cat No-507790 of Legrand or equivalant of Havells,Standard,Indo Asian complete all as specified and directed.
Material and labour in repair for MCCB 4 pole, 415 volts,TMA type, 63 amps with breaking capacity 25KA and fixed on existing LT panel board including electrical connection as per site requirment complete all as specified and as directed.
Supply and fix MCB SPN 20-40 Amps 10 KA, 240 V connected through copper thimbles of suitable size complete all as directed and specified. Make: Legrand/ABB/Siemens/Merlin Gerin
Supply and fix MCB SP 3-32 Amps 10 KA, 240 V connected through copper thimbles of suitable size complete all as directed and specified. Make: Legrand/ABB/Siemens/Merlin Gerin
Material and labour in repair for Earthing complete with and including galvansied steel earth plate electrode 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below ground level earth plate connected with and including 4 mm dia GI wire as earthing lead by means of bolts, nuts, check nut and wahers of galavanised iron all as shown in Electrical plate No.3 of MES Sch part I and testing on completion. Including neccessary excavation and earth work, adequate common slat, charcoal dust and funnel PCC (1:3:6) type C-1 using 40mm graded crushed stone aggregate pit with pre-cast RCC (1:2:4) type B-1 cover using 20mm graded crushed stone aggregate, 40mm thick reinforced with 8 mm dia bars, MS bar 3 Nos both ways funnel with 20 mm dia GI grade watering pipe earthing lead with and including GI protection pipe light grade 15mm dia up to 7.5meter. from earth plate to equipment earth point complete all as specified and directed.
Taking down carefully after disconnecting electrical/water supply connections and transporting to the work shop for carry out the servicing / over hauling of the storage type electric water heater (Geysers) of storage capacity 25 liters / 50 litres of any make / type by cleaing the inner surface of the tank / heating element with and including chemical to remove the scaling / rust , replacement of defective spare parts and reassembling the same after replacing burnt out parts and refixing on its original position including testing complete all as specified and directed. Note :- Spare parts required to be replaced shall be measured and paid seperately as "supply only."
Supply only heating element of the following ratings as required at site including rubber washer/packing. complete all as specified and directed. Make : "RECOLD /THEETA / SWARNA or equivalent ISI marked :- (a) 1 KW/1.5 KW
Supply only base assembly complete i.e., "SIPHON SET" inlet, outlet, thermostat pockets with and including drain plugs and screws for fixing the element inclusive of clamps for holding the element with and including nuts and bolts complete all as specified and directed.
Supply only thermostat stem type suitable for geysers 25 liters / 50 litres. ISI marked complete all as specified and directed.
Supply only 15 mm dia chromium plated copper tube with and including two brass adopters 18" long and fixing in position for hot water/outlet connections complete all as specified and directed.
Supply only inner water tank of geyser 25 litre capacity to suit the exising geyser complete with and including nut bolts complete all as specified and directed.
Supply only outer tank of geyser 25 litre capacity to suit the exising geyser complete with and including all standerded accessories complete all as specified and directed.
Supply only siphon set by soldering/brazing including replacement of bolts/nuts/washers/rubber gaskets etc complete all as specified and directed.
Supply only indicator lamp rectangular / round type suitable for 25 litres / 50 litres geysers complete all as specified and directed.
Supply and fix in repair PVC connecting pieces with and including two brass adaptors 18" long and fixing in position for cold / Hot water / inlet connection complete all as specified and directed.
Supply and fix in repair stop cock brass ISI marked 15mm dia and connecting up in position complete all as specified and directed.
Supply and fix in repair Gun metal Non-Return valve 15mm dia complete all as specified and directed.
Supply and fix in repair pressure release valve 15mm dia complete all as specified and directed.
Material and labour for painting of storage type water heater any capacity (25 liters/50 litres) after preparation of surface and applying two coats of synthetic enamel paint, white externally complete all as specified and directed.
Taking down the defective ceiling fan of any sweep and make after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine and carry out the repairs and replacement of defective spare parts as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor and applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding excluding rewinding to improve the insulation value complete all as specified and directed. (b) Spare parts required to be replaced shall be measured and paid for seperately as "supply only".
Supply only ball bearings for exhaust/ceiling fan of any sweep complete all as specified and directed. Make : SKF/NBC/FAG
Supply only GUN METAL BUSH for exhaust / ceiling fan of any sweep complete all as specified and directed.
Supply only fan condenser of following sizes complete all as specified and directed :- (a) 2.5 mfd
(b) 4 to 6 mfd, Make : Asian / EPCOS
Supply only rubber reel, nut bolts, washer, split pin complete set by dismantling existing complete all as specified and directed.
Supply only Fan connector suitable for wire connection complete all as specified and directed.
Supply only ceiling fan down rod of MS pipe 15mm bore 1.2 Meter length inclding cutting/threading making tide for fixing providing check nuts wachers etc complete all as specified and directed.
Material and labour for Re-winding of ceiling fan any sweep with and including same guage supper enameled copper wire to maintain speed at load complete all as specified and directed.
Material and labour for Painting of ceiling fan any sweep taking down vide item No 93 by applying one coats of synthetic enamel paint after preparation of old surface complete all as specified and directed.
Taking down the repairable exhaust fan of 300 mm / 380 mm sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine and carry out the repairs as required and replacement of bearings/bushes and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the exhuast fan by thoroughly clelaning the bearing, shaft, stator, rotor and applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding excluding rewinding to improve the resistance value complete all as specified and directed. Note :- Bearing/bush required to be replaced shall be measured and paid seperately as "supply only".
Material and labour for Re-winding of exhaust fan 300 mm / 380 mm sweep, any make with and including same guage supper enameled copper wire to maintain speed at load complete all as specified and directed.
Material and labour for painting of exhaust fan 300mm / 380mm sweep, any make by applying one coats of synthetic enamel paint after preparation of old surface complete all as specified and directed
All as per above item No- 81 here in before but exhaust fan 450mm sweep. (a) Servicing/overhauling the exhaust fan by thoroughly cleaning the bearing, shaft, stator, rotor and applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding excluding rewinding to improve the insulation resistance value complete all as specified and directed.
Re-winding of exhaust fan 450 mm sweep, any make,with and including same guage supper enameled copper wire to maintain speed at load complete all as specified and directed.
Material and labour for painting of exhaust fan 450 mm sweep, any make by applying one coats of synthetic enamel paint after preparation of old surface complete complete all as specified and directed
Supply only ball bearings for exhaust/ceiling fan of any sweep complete all as specified and directed. Make : SKF/NBC/FAG
Supply only gun metal bush for exhaust / ceiling fan of any sweep complete all as specified and directed
Taking down the existing old unserviceable Geyser of any make and capacity and handed over to MES store, supply and fix new Geyser of capacity 25 litre vertical/ Horizontal type,5 star rated,ISI mark,Single phase,250v, 50 Hz inlcuding making Electrical / Water supply connection and additions / Alterations to Existing Brackets, testing complete all as specified and directed. Make:Havells/ V- Guard /Bajaj /C&G
Taking down the existing un-serviceable exhaust fan of any sweep including depositing to MES store and Supply and fixing new exhaust fan 300 mm sweep,single phase 230 volts, 50 Hz complete with and including new copper wire for connection complete all as specified and directed (Make: Havells Cat Ventilair DB or equivalent in USHA/ Bajaj/ Crompton/Greaves/khaitan)
Taking down the existing un-serviceable ceiling fan of any sweep deposited to MES store and Supply and fixing new ceiling fan 1200 mm sweep single phase 230 volts, 50 Hz 5 star rated with and including new copper connection wires complete all as specified and directed. Make : Cat ES 4 of Havells/ Bajaj/ Crompton/Greaves/Usha/Khaitan
Supply and fix in repair Flexible twin core copper wire 23/0.0076 complete all as specified and directed.
Dismanlting existing defective/ damaged lightening protection conductor from complete roof and down conductor fitted on wall complete all as specified and directed.
Supply and fix aluminium strip 25 x 3.15 mm with and including saddle and fixing screws etc for roof and down on wall up to ground up to test point complete all as specified and directed.
Supply and laid in ground galvanised iron strip of size 32 mm x 6 mm as earth continuty conductor complete all as specified and directed.
Supply and fix in repair test point terminal block made of gun metal or phosphoras bronze size 75mm x 75 mm x 25 mm drilled and screwed inc;uding 3 Nos 8 mm dia 25 mm long hax head screws complete all as specified and directed.
Supply and fix in repair air termination single pointed aluminium rod 12 mm dia 300 mm long complete all as specified and directed.
Material and labour in repair for Earthing complete with and including galvansied steel earth plate electrode 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below ground level earth plate connected with and including galavnised iron strip 25 mm x 4 mm as earthing lead by means of bolts, nuts, check nut and wahers of galavanised iron all as shown in Electrical plate No.3 of MES Sch part I and testing on completion. Including neccessary excavation and earth work, adequate common slat, charcoal dust and funnel PCC (1:3:6) type C-1 using 40mm graded crushed stone aggregate pit with pre-cast RCC (1:2:4) type B-1 cover using 20mm graded crushed stone aggregate, 40mm thick reinforced with 8 mm dia bars, MS bar 3 Nos both ways funnel with 20 mm dia GI grade watering pipe earthing lead with and including GI protection pipe light grade 30mm dia up to 7.5meter. from earth plate to equipment earth point complete all as specified and directed.
Material and labour in repair for PCC block of size 15 cm x 15 cm x 10 cm with and including PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregade for mounting of aluminium strip with and including porcelain insulator on roof top and necessary form work completed all as specified and directed.
Supply and fix in repair porcelain insulator for mounting of aluminium strip on roof top/ on wall for down conductor complete all as specified and directed
Material and labour for cleaning of water storage tank above / under ground sump by draining out complete water, scrapping the inner walls of tanks with wire brush / brooms, for removing the fungus, algae, soil, sludge mud etc complete including rewashing the inner walls of tank with fresh water to ensure complete cleaning including painting with one coat of water proof antifungal epoxy paint and writing on the outer walls of the tank with synthetic enamel paint the date of cleaned, due date of next cleaning and capacity of reservior complete all as specified and directed of following. Notes : (i) Expandable items such as wire brush, brooms cleaning and chemicals deemed to be included in the quoted rates. (a) Water storage tank/reservior of capacity 30000 Gallons to 50,000 Gallons for fresh water in Ganeshkhind pump House.
(b) Over head Tank of capacity 100000 Gallons.
Material and labour in repair for painting with one coat of synthetic enamel paint by using brush to motor and pump set including cleaning and preparing surface duly scraping old paint and writing SM/MES No.all as specified and directed by Engineer-in-charge for following:- (a) 40 to 75 HP motor
Material and labour in repair for painting of old painted surfaces of pipe 100 mm to 150 mm dia including prepration of surfaces and applying one coat of synthetic enamel paint complete all as specified and directed and required at site.
Material and labour for painting of old painted surfaces with one coat synthetic enamel paint by using brush to sulice valve and wheel of size 100 mm to 200 mm dia including cleaning with and including chemical agent and preparing surface duly scraping old paint complete all as specified and directed .
Material and labour for Overhauling the centrifugel pump set by dismantling the pump set,opening,cleaning,greasing including replacement of spare parts and reassembling after repairs including,metaling,grinding etc transpotation,reinstalling back to position and testing complete for the following capacites of pump sets complete all as specified and directed. Note:-Spares parts required to be replaced will be measured and paid depaterly under relevent items of the schedule 'A' as "supply only". (I) 30 HP to 75 HP Pump DSM 4 RR/DSM 4 RM/DB 65/20
Supply only following spares for 30 to 75 HP Pump DSM 4RR/DSM4 RM /DB 65/20, Pumps(Make:-Kirloskar pumps) complete all as specified and directed:- (a) Shaft sleeve
(b) Shaft sleeve nuts ( set of 4)
(c) Bearing cartridge DE/NDE
(d) Bearing cover DE/NDE (set of 2) Split gland coupling
(e) Bearing cap (set of 2)Wear Ring
(f) Bearing lock nut
(g) Throat bush (set of 2)
(h) Gland packing 10MMSQ
(j) DSM 100/36 set of Gaskets
(k) DSM 100/36 set of 'O' rings
Disconnecting the electrical and mechnical connection of burnt electrical motor from the site/location including transporting to and from to workshop, Rewinding of electrical motor by dismantling and removing the burnt out copper winding wire,cleaning the slots of stator with petrol and brushes,winding with and including polyster based super enameled copper wire of same guage original one with and including proper class of insulation including varnishing and heating the coil and remove the air bubbles complete,stator/roter after rewinding and replacement of rubber packages (measured seperately as supply only),reassembling all parts including reinstalling,connection to original position and testing on full load complete all as specified and directed by Engineer-in-charge for capacity of motor as per following:- Note :- Spare parts required to be replaced shall be measured and paid for seperately. (a) 30 HP three phase motor 415 V
(b) 75 HP three phase motor 415 V
Supply only rubber packing sheet 3 mm thick complete all as specified and directed.
Supply and fixing in repair roller ball bearing/Double ball bearing thrust ball bearing of pumps/motor of following catalouge Nos complete all as specified and directed. (a) 6309
Supply and fix in repair power contactors MNX 110 type with and including 2NO+2NC ,CP No.CS94137 complete all as specified and directed.
Supply and fix in repair unserviceable pressure guage range 0 to 14 Kg/cm2 with 100 mm dia with and including one stainless steel cock complete all as specified and directed.
Supply and fix in repair rubber bush for pin type coupling for any type of pump and motor complete all as specified and directed.
Supply and fix lead pig for repair of leaking joints complete all as specified and directed.
Supply and fix spun yarn for repair of leaking joints complete all as specified and directed.
Supply and fix lead wool for repair of leaking joints complete all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for taking out/laying for GI/CI pipes complete all as specified directed and getting out in:- (a) Soft/loose soil
(b) Hard/dense soil
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and directed by Engr-in-Charge
Removing excavated materials not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.
Material and labour for dismantling the old valve chamber and provision of brick massonary vave chamber of the following sizes(internal dimensions) including necessary excavation and earth work in any type of soil,PCC(1:4:8),type D2 using 40 mm graded crushed stone aggregate in foundation,brick massonary of wall thickness of 230 mm in10 mm thick cement mortar (1:6), rendering Cement mortar (1:6) internally and externally including to a depth of 15 cm below ground level,3 mm thick hinged MS iron cover as sprcified in IS-3950-1979 embeded in PCC with locking arrangment and painting with and including two coats of distinctive colour synthetic enamel paint over and including a coat of red oxide primer, PCC(1:2:4) type B1 using 20 mm graded crushed stone aggregade 50 mm thick coping including necessary form work and locking arrangment etc all for 150/200/250 mm dia valve complete all as specified and directed:- (a) 900x900x1200 mm
(b) 1200 mm x1200 mm x1200 mm
Taking down CI water mains including Burning out leaking lead joints in position and removing of old lead for the following sizes complete all as specified and directed by Engineer-in-charge :- (a) 80 mm dia bore of pipe
(b) 100 mm dia bore of pipe
(c) 150 mm dia bore of pipe
Material and labour for run lead joint for CI pipes/fittingscomplete with and including necessary jointing material such as pig lead and spun yarn,fire wood for jointing of pipes complete all as specified and directed by Engineer-in-charge for the following size pipes:- (a) 80 mm dia bore of pipe
(b) 100 mm dia bore of pipe
(c) 150 mm dia bore of pipe
Cutting existing steel tubing for alterations or additions of fillowing sizes complete all as specified and directed:- (a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
Screwing existing steel tubing for alterations or additions complete all as specified and directed :- (a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
Taking up or down steel tubing and connections and removal of unserviceable tubing as sch of credit.Complete all as specified and directed of follwing dia of pipe:- Note:- Excavation and earth work shall be measured and paid for seperately. (a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
(f) 80 mm bore
Supply laying and fixing GI tubing medium gradelaid in trenches complete with and including all accessories such as tees,union,bends,nipple,reducer etc all as required at site for branch connection Complete all as specified and directed of following dia of pipe :-Make:- Tata/Jindal/Zenith Note:- Excavation and earth work shall be measured and paid for seperately. (a) 15 mm bore
(b) 20 mm dia bore
(c) 25 mm dia bore
(d) 40 mm dia bore
(e) 50 mm dia bore
(f) 80 mm dia bore
Supply and fix in repair gun metal globe or stop/gate valve with and including iron wheel head screwed both ends for iron pipe including neceaasry accessories such as nipple,union for GI pipe of the following size. Complete all as specified and directed :- (a) 15 mm dia bore
(b) 20 mm dia bore
(c) 25 mm dia bore
(d) 40 mm dia bore
(e) 50 mm dia bore
Disconnecting/taking down unserviceable worn out CI sluice valve with SS Spindle and supply and fix new CI sluice valve in repair as required at site and complete all as directed by Engineer-in-charge of following sizes :- Make:- Leader/Kartar/Bir/L & T/Venus/Kirloskar (a) Sluice valve 100 mm dia bore
(b) Sluice valve 150 mm dia bore
(c) Sluice valve 200 mm dia bore
Supply and fix in repair Cast iron Air release valve with two air outlets,confirming to IS 14845 of size 80 mm dia bore and fixing up in Cast iron water supply mains of size 150 mm dia. Complete all as specified and directed. Make :- Leader/Kartar/Venus/L & T//Bir/Kirloskar
Supply and fix in repair Foot valve ball type heavy duty suitable for 150 mm dia pipe line including replacement of old unserviceable foot valve any type and make from suction pipe of pumpset all as per the direction of engineer in charge complete all as specified and directed. Make :- Bir/L & T/Venus/Kirloskar/Upadhyay
Material and labour for cutting of Roads / Plinth for removal / laying of pipe and making good the disturbed surfaces as per existing adjoining surfaces. Complete all as specified and directed. Note: PCC will be measured and paid separetely.
Material and labour for PCC 1:2:4 type B 1 using 20 mm graded crushed stone aggregate for making good road/foot path/hard standing/drain/ bldg plinth protection and foundation for motors, pumps and starters all as per site requirement. Complete all as specified and directed by Engr-in-Charge.
Disconnection of existing water storage tank of PVC/RCC tank at 3.0 meter height and above, removal of water if any from the tank and cleaning the bottom and internal periphery of the tank by using wire brushes to remove the Mud, Algae, fungus etc without damaging the water tank and finally rinsing the tank by using chlorine/bleaching powder/altoc GP or any other similler type of disinfectent chemical as directed by Engr-in-Charge and re-fixing in the position complete all as specified and directed at site for follwing :- Note : Date of cleaning shall be written after cleaning in DD/MM/YY formate with synthetic enamel paint after removing the earlier date if found exisitng (a) Capacity upto 500 Liters to 750 Liters
Supply and fix in repairs ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe and fixed for the following sizes at any height of building. Complete all as specified and directed. Make :- Bir/L & T/Venus/Kirloskar/Upadhyay (a) for 15mm dia bore
(b) for 20mm dia bore
(c) for 25mm dia bore
Material and labour for repair to water supply line (Fresh water) with mechanical joint, of CI/GI pipe line of size 25 mm/40 mm/50 mm/80 mm including taking out the leaked /puncture/cracked existing pipe , cutting of damaged portion of pipe through welding, making rough surfaces smooth and champhered by grinding and then connected through GI pipe jointing material adequate size complete as per site requirement Complete all as specified and directed. Note : Testing/commissioning the pipe line on full pressure after completing the job will be carried out and payment will made of this job if found sucess other wise the same will be not done against and no extra payment will be made on this account.
Supply and fix in repair CI/DI fitting for spigot socketed pipes such as Bends (any type, radius an angle) Tapers any tpe, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, `Y' junction, double branch, cross (all sockets or flanged ) collars, caps and plugs, Connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth Upto150 mm bore pipe including joints and jointing material Complete all as specified and directed. Note :- Exacavation and earth work shall be measured and paid for seperately.
Material and labour for routine maintenance consisting of normal repairs with periodical routine maintenance and testing of DG set of 75 KVA complete (i.e. Engine, Alternator etc) under GE (I) R&D Pashan including all consumables like cotton, waste cloth, kerosene oil etc. Maintenance will be carried out as and when ordered in writing by Engineer-in-Chagre, as maintenance the following Complete all as specified and directed :- (a) Change or top up engine oil. (b) Check clearance of suction and exhaust valves and adjust if required. (c ) Changing of oil filter, fuel filters, screen filters assy. (d) Changing of water filter element. (e) Topping up of coolent. (f) Change of Hydraulic governer oil. (g) Tightening of all nut bolts. (h) Greasing of all points. (j) Checking of any leaking in fuel and oil lines. (k) Cleaning of fuel tank by taking out the dirt and sludge, cleaning the tank thoroughly. (j) Replacement of battery terminal made of Brass with necessary brazing NOTE 1 : Labour charges for dismantling / taking down and replacement / refixing new parts as and when required is deemed to be included in unit rate quoted. NOTE 2 : Spare parts like oil filter, fuel filter, screen filter by pass filter,Engine oil, battery, terminals, coolant, hydraulic pipe, fan belt, etc will be measured and paid separately as supply only. (a)75 KVA DG Set at Pump house of Ganeshkhind Area
Supply of Engine oil 20W40 for DG set. Complete all as specified and directed. Make : castrol or equivalent make as approved by GE.
Supply only Prremix Ethylene Glycol coolent for Engine Radiator.Complete all as specified and directed. Make : castrol or equivalent make as approved by GE.
Supply only battery terminals made out of brass with nut bolts and washers and necessary brazing to cable complete all as specified and as directed
Supply only flexible braided high pressure hydraulic pressure pipe including both ends chromium plated connections check nuts and washers for fuel tank to FIP. Complete all as specified and directed.
Supply only by pass filter element with and including 'O' ring suitable for DG Sets of 75 KVA. Complete all as specified and directed.
Supply only fuel filter primery and secondary with and including 'O' ring for DG Sets of 75 KVA .Complete all as specified and directed.
Supply only oil filter with and including 'O' ring for DG Sets of any capacities complete all as specified and directed.
Supply only fan of required size belt for DG Set, of required size. Complete all as specified and directed. Make : Fenner / Dunlop.
Material and labour for painting of old painted surfaces with two coats of existing colour asian paint with mechanical pressure arrangement induding wiriting of MES/ SM NO on DG Set and alternator capacity 75 KVA including cleaning with and including chemical agent and preparing surface duly scraping old paint complete all as specified and directed by Engr-in-Charge.
Material and labour for cleaning of raditor,external cleaning by vaccum cleaner,petrol washing and taking out the carbon deposits from cooling fins and internal cleaning by using restor plus liquid and inhibitor corrosion of 75 KVA DG Set. Complete all as shown and directed by Engineer-in-charge.
Supply and fix in repair Led Acid Battery of 180 AH ,12 V DC for DG Set. Complete all as specified and directed of make: Exide
Supply and fix in repair LED aviation light on over head tank integral type comprising of aluminium housing with polycarbonate luminanaires including LED lamp comple including connection wire 2.5 sqmm copper wire two core 30 Running meter and MCB SP 3 Amp two pole with and including enclusure box complete all as specified and directed. (Make : Cat BGAV 302 LED of Bajaj or equivalent in Havell's/ Crompton/ Philips
Material and labour for dry crushed stone dust/ river sand filling in trenches to required width at bottom and top of cable cushioning including spreading leveling and consolidation complete all as specified and directed. Note : Punned thickness shall only be measured and paid.
Supply and lay in trenches reinforced precast concrete cable cover class HVV type 1 ,flat size 450 mm x 230 mm x 50mm for cable protection complete all as specified and directed by the Engr-in-Charge.
Material and labour in repair for GI tube medium grade 80mm diameter with and including all fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning in repair 22000 volts grade, 3 core 95 Sq mm HT XLPE shielded core type wrapped with and including galvanised steel strip armoured, PVC sheathed, heavy duty, electric cables, with and including multistranded aluminium conductor suitable for 22 KV, 3 Phase AC, 50Hz, ISI marked, laid in trenches/passing through pipe/duct/ road crossing or fixed on poles, walls with and including suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., complete all as specified and directed. Note: Excavation and earthwork, sand cushioning and cable covers will be measured and paid for separately.
Material and labour in repair for straight through joint,heat shrinkable,type,for HT OH AB cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,single core,95 to 120 sqmm,22 KV complete all as specified and directed by Engineer-in-charge.Make : M seal/ Denson
Material and labour in repair for outdoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 95 sqmm, 22 KV complete all as specified and directed by Engr-in-charge. Make : M seal/ Denson
Cutting the tree branches which touches the LT/HT OH lines and 2.5 meter away from centre line of HT/LT OH line span not exceeding 60 meters between poles and deposting the tree branches/leaves at 30 meter distance away from site complete all as specified and directed. Note : Any number of tree branches cut in one span will be measured as one length for payment purpose.
On load filteration of transformer oil by contineous circulation of transformer oil through mechanical filters to achive the desired dielectric strength of 35 KV for one minute at 4 mm gap complete all as specified and directed. Note: 1.Oil samples are to collected from top and bottom of oil tank and test results to be recorded for each sample before and after filteration.
Supply and topping up transformer oil of dielectric strength 50 KV at 4 mm gap in transformers of various capacities installed in various locations. complete all as specified and directed. Make of Transformer oil: Savitha/Castrol or equivalent as approved by GE. Notes : (a) New Transformer oil will be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer. (b) Transformer oil shall be supplied in sealed barrel with test result and test certificate.
Supply and fix in repair in repair breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15mm /20mm /25 mm dia with and including suitable reducers/connectors etc as per site requirement /capacity of transformer.complete all as specified and directed. Note : Rate quoted shall be deemed to include the cost of modification if any required to fix on existing MS Pipe.
Matrerial and labour for repair to gang operated air brake switch device upto 100 Amps,22 KV capacity including greasing/oiling of all moving contacts,replacement of nut bolts,washers of suitable sizes,unserviceable spares and jumper connections in all phases for smooth functioning of the devices complete all as specified and directed. Note : Unserviceable spares and jumper connections required to be replaced will be measured and paid separately as "Supply only"
Supply only the following items : (to be incorporated under item No : 229 above) Complete all as specified and directed :- (a) Male contact/moving contact with blade arcing hornof gang operated AB switch devices suitable for 22 KV
(b) Female contact /fix contact jaw arcing horn for gang operated AB switch devices.
(c) Tinned copper flexible jumper 200/200 Amps
(d) Post top Polymer insulators of gang operated AB switch devices.
(e) Middle post Polymer insulators of gang operated AB switch devices.
(f) Bottom post Polymer insulators of gang operated AB switch devices.
(g) MS jumper carrier.
(h) Back connector plate.
GI pipe, heavy grade 25 mm dia made to shape for gang operating from ground.
Material and labour for repairs to drop out fuse complete of upto 400 Amps,22 KV capacity including replacement of worn out nut bolts,washers,of suitable size /unserviceabele spares and jumper connections for smooth functioning of the devices complete all as specified and directed by Engr-in-charge. Note : Unserviceable spares like contacts/insulators will be measured and paid seprately as "Supply only"
Supply only the following items (to be incorporated under Item No 239 above). Complete all as specified and directed. a) Fix top contact/ contact for drop out fuse.
b) Fix lower contact for drop out fuse.
c) Post insulators of drop out fuse.
Supply install testing and commissioning in repair of 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete , GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts heavelly tinned to withstand weather Complete all as specified and directed.
Supply and fix in repair Polymer Pin type insulator of 22 KV including necessary hardware. Complete all as specified and directed.
Supply and fix in repair Polymer disc type insulator, ball and socket type, white brown or green suitable for 22KV including necessary hardware Complete all as specified and directed.
Supply and fix in repair defective lightining distribution surge arrestor, non linear type MCOV, 18 KV, 5 KA with and including all fittings bolts nuts and washers etc complete all as specified and directed.
Material and labour in repair for preperation of old painted steel surface of 6/4/2 pole structure HT/LT street light/HT steel tublar poles 8.5meter /9.0 meter /11meter /13 meter long above GL/coping including cross arms,channels,Flat iron,Clamps in LT/HT OH line by scraping with wire brush/ sand paper and applying one coat of aluminium paint including pole numbering all as specified and directed by Engr-in-charge for the following types:- b) HT 4 Pole structure 11 meter long
c) HT 2 Pole structure 11 meters long
d) HT pole 11 meter long
e) LT pole 8.5meter/9 meter long
Disconnecting the transformer outdoor type from HT/ LT system and opening carefully by draining out transformer oil upto HT/LT boxes for rectifying the leakage by replacing the unserviceable spare parts of capacity 50 KVA to 750 KVA transformer, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecting the HT/LT system after the leakages have been rectified and tested on available electric load Complete all as specified and directed. Note : Defective parts required to be replaced will be measured and paid separately as "Supply only" under respective items here in after.
Supply only LT bushings with and including brass studs of existing specification.
Supply only top cover gasket set.
Supply only HT bushing with and including stud 22 KV of existing specification.
Material and labour for preparation of old painted surfaces of transformer, removing rusted scale/oil and painting of transformer with one coat of synthetic enamel paint of approved make duly Marking/ Writting MES/SM No. Complete all as specified directed by Engr-in-charge for : (a) 160 KVA to 250 KVA capacity of transformer.
(b) 300 KVA to 500 KVA capacity of transformer.
Re-Stringing of HT/LT over head conductor and earth conductors, unwinding and visual testing of insulator, rewinding of ACSR and GI earth wire guard/ earth conductors rigidly with winding wire Complete all as specified and directed by Engr-in-charge
Dismantling and taking down LT/ HT OH line conductor and removing to store for safe custody or issue under schedule of credit complete all as specified and as directed.
Material and labour for disconnecting from existing main taking out from LT panal board for servicing and overhauling LT ACB of any make 800 Amp to 1600 Amp, 50Hz 415V AC Draw out type including taking out existing mechanism complete with servicing of operating machnism, triping mechanism and spring charging mechanism complete to make it funtioning smoothly and including replacement of unserviceable spares and fixing in its original postion with all connections and testing complete all as specified and directed. Note : Major spare parts required to be replaced shall be measured and paid for separetly under respective items of BOQ here in after, however cost of minor spares except mentioned here in below shall be deemed to be included in item rate.
Supply only Following spare parts suitable for LT ACB suitable for 800A-1600 A Capacity Frame No LH 800DM-1 Complete all as specified and directed:- (a) Main isolating contact (Male and Female) jaw type complete inclubing fixing accessories
(b) Shunt Trip coil/ Closing coil 415 VAC suitable for 800 amps ACB
(c) Under voltage tripping divicee (UVT) 415 volts
(d) Single phae CTS at rating 800/5A
Supply and fix in repair MCCB 4pole, 400 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable type with thermal -magnetic release type. Complete all as specified and directed.
Supply and fix in repair MCCB 4pole, 250 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable type with thermal -magnetic release type.Complete all as specified and directed.
Supply and fix in repair MCCB 4pole, 200 Amps, 25 KA, 415 volts, over load and short circuit protection, adjustable type with thermal -magnetic release type. Complete all as specified and directed.
Supply and fix in repair MCCB 4pole, 100 Amps, 25 KA, 415 volts, over load and short circuit protection, adjustable type with thermal -magnetic release type.Complete all as specified and directed.
Material and labour in repair for MCCB 4 pole, 415 volts with termal magnetic adjustable type, 63 amps with breaking capacity 16 KA and fixed on existing LT panel board including electrical connection as per site requirement complete all as specified and as directed. Note for item No. 264 & 268 :i) Minor addition alteration in panel required for fixing of above items are deemed to be included in the above quoted rates. ii) Make : Legrand/ L&T/C&S/Havells/Siemens.
Supply and fix in repairs Pin type, porcelain, vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia suitable for 1100 volts grade including taking out existing unserviceable insulator complete all as specified and as directed. Make :- JSI or equivalent ISI marked made as approved by GE.
Supply and fix insulator shackle type, porcelain, vitreous, white, brown or green insulator including galvanised and mild steel straps of size 31mm x 5mm, washers, insulator bolts, washers and nuts, size of insulator 100 mm height, 115 mm dia with and including 14 mm dia bolts for 1100 Volts grade including taking out existing insulators complete all as specified and as directed. Make : JSI or equivalent ISI marked made as approved by GE.
Material and labour in repair for aluminium conductor steel reinfoced for over head line, fix on pole bringing the sag with in limit, fixing to the insulator by means of necessary binding with and including 14 SWG aluminium wire complete all as specfied and directed.
Material and labour for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundations of stays and poles, copping of poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Supply and fix in repair LED street light /road way luminaries 45 watts of make Havells Cat ENDURAPEARLPLUSSL45WLED757SASYTOPC OR Equivalent in Bajaj, with and including pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed.
Supply and fix in repair LED street light /road way luminaries 60 watts of make Havells Cat ENDURAPEARLPLUSSL60WLED757SASYTOPC OR Equivalent in Bajaj,Havells or equivalent with and including pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed.
Supply and fix in repair LED street light /road way luminaries 90 watts of make Havells Cat ENDURAPEARLPLUSSL90WLED757SASYTOPC OR Equivalent in Bajaj, with and including pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed.
Supply and fix in repair LED flood light 100 watts of make Havells Cat JETAIRISFLS100WLED757ASYMLTG OR Equivalent in Bajaj, with and including pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed.
Material and labour in repair for Cross arms, bracings, supports, clamps and back plates fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size fixing to existing pole and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint including preparation of New steel surfaces as indicated or directed by Engineer-in-Charge Complete all as specified and directed.
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with and including hinged door and locking arrangement of size 140mm x140mm x100mm internal comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminal for loop in and loop out suitable for single phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25mm x 3mm MS flat iron complete all as specified and directed. Make : Sintex or equivalent as approved by GE.
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with and including hinged door and locking arrangement of size 300mm X 200mm X 105 mm (internal ) comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminal for loop in and loop out suitable for three phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25mm x3mm MS flat iron complete all as specified and directed. Make : Sintex or equivalent as approved by GE.
Supply and fix in repair Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with and including suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 8 kW single-Phase load .Contactor Rating: 40.Amps ( 2-pole ).MCB (single-pole) Rating:63.Amps (2 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (ENC Approved) Contactor: BCH/L&T/Schneider or equivalent MCB: Hager/Schneider/Legrand/L&T. Complete all as specified and directed. Make:SWADEEP – 02EC 8kW1P or equivalent as approved by GE.
Supply and fix in repair CT with ratio 10/5A , VA-10, Class-0.5S suitable for multiparty residential connection approved and tested by MSEDCL complete all as specified . Make :- Huphen Electromech/Schieneder/CG/AE/Siemens or equivalent make as approved by GE.
Supply and fix in repair PT with ratio 22KV/V3/110V/V3, VA-50, Class-0.5 suitable for multiparty residential connection approved and tested by MSEDCL complete all as specified. Make :- Huphen Electromech/Schieneder/CG/AE/Siemens or equivalent make as approved by GE.
MAYUR ELECTRIC SERVICES
Borole Electricals
Neha Enterprises
R. K. Industrial Fabricators
M/S - KRUPA ELECTRICALS
M/S - FRONTLINE ELECTRO SYNDICATE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .