Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94,200Accepted-AOC NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹1.1 L+₹14,300 (15.2%)Rejected-Finance LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹1.2 L+₹30,505 (32.4%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical NOT AVAILABLE | - | Rejected-Technical No due to firm not having category as per NIT | |
| 5 | Rejected-Technical NOT AVAILABLE | - | Rejected-Technical No due to firm not having category as per NIT |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
16 Mar 2021, 6:00 pmClosed
GE (AF) Mohanbari
GE (AF) Mohanbari
PROVISION OF CHEMICAL EARTH PIT AT VARIOUS LOCATION AT AFS DINJAN UNDER GE (AF) MOHANBARI.
2021_MES_429680_1
NIT No . 8001/282/01/E8 OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
AFS Dinjan
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Mohanbari
₹5,000
Yes
31 Mar 2021
10 Mar 2021
18 Mar 2021
10 Mar 2021
16 Mar 2021
11 Mar 2021
Amount
Material and labour for Earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to copper earth lead strip of size 20 mm x 3 mm thick by means of brazing, bolts, nut, check nuts and washers made out of brass and connected to main switch board or main control board all as shown in electrical plate No 3 of SSR part 1 including three coats of white wash on plastered/PCC surface (Exposed surface) and pit number to be marked on a GI plate above 45 cm from GL as per color code followed in AF station including testing. complete all as specified and directed by Engineer-in-charge. Notes:- 1) The unit rate also including for excavation, earth work in any type of strata, PCC 1:3:6 mix, Type C1 pit, pre cast cover RCC (1:2:4) type B-1 cover slab of size 300 mm x 300 mm x 100 mm with 8 mm dia TMT bar @150 center to center both ways with one handle for lifting made out of 8mm dia mild steel bar 20 mm bore galvanised iron pipe 'medium grade' for watering, funnel, wire mesh and charcoal or coke of alternative layers of 15 cm and 40 mm bore galvanised iron pipe "light grade" for protection of earth lead connection. 2) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Material and labour for free Chemical earthing system complete with 02 (two) nos. copper rods, internal rod of 19 mm dia and external rod is hollow and having internal dia. 48 mm and each rod of length 3000 mm electrode buired at suitable distance apart directly in ground, to bore holes of 120 mm dia vertically to a depth not less than 3.6 m deep below ground level with top edge of earth electrode at a depth not less than 100 mm below normal ground level, including back filling of bore holes with advanced earth enhancing compound for artificial treatment to soil so as to achieve earth resistance below 01 ohms as specified in para 19.140 of SSR Part-I (2009) including three coats of white wash on plastered/PCC surface (Exposed surface), one coat of synthetic enamel paint of approved color on pit cover and pit number to be marked on a GI plate above 45 cm from GL as per color code followed in AF station including testing. complete all as specified and directed by Engineer-in-charge. Note : 1) The unit rate also including for excavation, earth work in any type of strata, PCC 1:3:6 mix, Type C1 pit, GI earth pit cover and GI plate for earth pit cover. 4) If the desired earth resistance is not achive during testing as per IS, the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable.
Supply and fixing for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20 mm x 3 mm thick, copper strip using porcelain clit/post insulators, complete all as specified and directed by Engineer-in-charge.
M/S A K BROTHERS
ANZ CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .