Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹18.6 L+₹2.6 L (16.0%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹19.0 L
EMD Value
₹37,960
Closing Date
5 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
COMPREHENSIVE MAINT, REPAIRS TO VARIOUS AC PLANTS AT MH JRC UNDER GE (EAST) JALANDHAR CANTT
2022_MES_556663_1
GE/JULL/ET-67/2022-23
Open Tender
Civil Works
Item Rate
335 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹37,960
Yes
24 Nov 2022
8 Oct 2022
12 Nov 2022
8 Oct 2022
5 Nov 2022
24 Oct 2022
Amount
Material and labour for de-scaling of condenser unit 50 TR AC central type with copper tubes by removing nuts & bolts, water connection and filling up of de-scaling acid HCL in condenser and manually cleaning of copper tubes with using Nylon brush of superior quality, iron rod for removing of complete scaling from tubes and water circulation through condenser including replacement of rubber gasket, nut & bolts and making necessary connections complete all as specified and as directed. (in OT AC Plant in MH)
Material and labour for servicing of Air handling unit 5000/8000 CFM of central AC plant by dismantling, assembling filters and testing for the following parts. (a) Inspect filters, removing and cleaning by using vaccum cleaner and refix same. (b) Clean cooling coil, fins by using caustic soda and water pressure method and applying Grease for all motors, check and adjust belt tension if required, check condition of blower shaft, scroll, impeller and bearings, check tightness of all electrical terminations, clean water line strainers, check proper balancing system , check for noise and vibration. (c) Check healthy operation of controls and safety devices.
Attending breakdown(except periodical maintenance) for any type AC plant, cold store, repair/replacement of unserviceable parts including carrying out minor repairs such as changing of small pieces of wires, tightening of loosen electric connections ,nuts, bolts screws, or switches, disconnecting and re-fixing of LT cables etc as required to make the system functional in any time by deploying sufficient technician alongwith with helper including necessary T & P complete all as specified and directed. Note: (a) Replacement of major items shall be measured and paid for separately under respective items. (b) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly. (c) Breakdown complaints will collected from complaint cell or by telephonically from duty staff/JE E/M/Engineer-in-Charge. (d) In case of failure on the part of contractor for attending any breakdown within 4 hours a penalty shall be imposed @ Rs.2000/- per complaints and recovered from his dues.
Dismantling overhauling testing and commissioning complete of reciprocating type compressor Capacity : 50 TR including suction and discharge line and other controls re-fixing in position after completion of over hauling at OT A/C plant including replacement of following parts:-
a) Worn out crank shaft assembly including filling material metalizing and grinding polishing to its original standard size at as directed by Engineer-in-charge.
b) Gasket set
c) Aluminium alloy connecting rod assembly
d) Valve plate assembly
e) Piston assembly
f) Valve reed suction
g) Valve reed discharge
h) Main bearing
j) Neo prine 'O' ring set
k) Oil pump assembly
Taking down the old discharge pressure sensor Supply and fix new discharge pressure sensor testing and commissioning 0-5 PSI 50 TR compressor
Taking down the old suction pressure sensor supply and fix new suction pressure sensor testing and commissioning 50 TR compressor
Taking down the old oil pressure sensor and supply and fix new oil pressure sensor testing and commissioning 50 TR compressor
MATERIAL AND LABOUR for disconnecting electric motor 10 HP and transporting to workshop, dismantling the same and taking out rotor assembly removing burnt winding coil of stator, cleaning the complete stator and rotor with carbon tetra chloride solution, rewinding the stator coil with super enameled copper conductor of proper size/gauge as per existing, inserting the new re-winded coils of stator duly varnishing and insulated with superior quality insulation material, replacement of old connection lead with superior quality PVC copper cable with stranded copper conductor from motor to connection plate, replacement of ball bearing, reassembling the motor, shifting to work site and connecting with the system, testing on full load complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 8.00 here-in-before but of 7.5 HP electric motor.
All as per srl item No 8.00 here-in-before but of 5 HP electric motor.
All as per srl item No 8.00 here-in-before but of 3 HP electric motor.
All as per srl item No 8.00 here-in-before but of 2 HP electric motor.
All as per srl item No 8.00 here-in-before but of 1 HP electric motor.
All as per srl item No 8.00 here-in-before but of 250 to 500 watt, single phase electric motor.
Dismantling the motor mono block pump set with motor any make 10 HP capacity servicing by cleaning lubricating and by replacing of ball bearing gland bolt, nut and washers, terminal connector, machining of shaft, gasket, gland rope, mounting bolts reassembling, re-fixing with bed and testing.
Replacement of gland rope suitable size of pump 10 HP all as directed.
Taking down blower with motor of any capacity, servicing by cleaning, lubricating, machining of shaft, replacement of ball bearing mounting bolts, reassembling and testing complete.
Taking down condenser fan motor of any capacity, servicing by cleaning, lubricating, machining of shaft, replacement of ball bearing mounting bolts, reassembling and testing complete.
Replacement of Fan blade of condenser fan motor of suitable size all as specified and directed.
Material and labour for check for any refrigerant leaks through flare joints, valve glands and complete refrigerant system with requires leak detector device like soap solution, halide torch or electronic leak detector and arresting leakages including necessary welding, bracing works binding with teflon tape as required at site and topping up the gas for required suction & discharge pressure for 50 TR central type AC Plant. Note : Refrigerant shall be measured and paid separately.
Material and labour for charging Nitrogen Gas in 50 TR capacity central AC plant maintaining pressure 350 Psi for checking of Gas leakage and removing water vapour choked in line, flushing out the complete system including gas leakage and detection with halide torch/ soap foam solution in system including gas welding flushing and making good the pipe line to make the system leak proof complete all as specified and as directed.
Material and labour for vaccumising the plant by using vaccum pump up to (-) 30 PSIG pressure and hold the same under vaccum pressure upto 24 hours including necessary welding and bracing if required complete all as specified and directed for 50 TR AC plant .
Supply and charging refrigerant Gas R-22 for AC plant of various capacities including maintaining proper pressure after filling of Gas complete all as specified or as directed by Engineer-in-Charge.
Supply and charging refrigerant Gas R-407 AC plant of various capacities including maintaining proper pressure after filling of Gas complete all as specified or as directed by Engineer-in-Charge.
Supply and charging refrigerant Gas R-410 AC plant of various capacities including maintaining proper pressure after filling of Gas complete all as specified or as directed by Engineer-in-Charge.
Supply and filling in fresh compressor oil N-68 for compressor of AC plant of various capacities to ensure the development of required oil pressure complete all as specified or as directed by Engineer-in-Charge. Note :- Compressor oil shall be supplied in company sealed containers only. Make :- Indian oil/ Bharat Petroleum/ Servo
Material and Labour for PVC insulated and sheathed, flexible wire with multi stranded copper conductor wire of size 3 core, 1.5 sqmm, ISI marked complete all as specified and directed.
Material and Labour for PVC insulated and sheathed, flexible wire with multi stranded copper conductor wire of size 3 core, 16 sqmm, ISI marked complete all as specified and directed.
Supply and fixing Digital Hygrometer with LCD Display with features of showing Time, Temperature and Humidity complete all as specified and directed.
Supply, install, testing and commissioning of Chiller control unit control unit with display board complete set suitable for 50 TR central type AC plant as per existing pattern and make it functional all as directed. Make : Softhard or equivalent as approved by GE.
Supply, install, testing and commissioning of Package type AC control unit with display board complete set suitable for 15/22 TR multiunit AC plant as per existing pattern and make it functional all as directed.
Supply and fixing in replacement limit switch Type-LSR with diecast cover with roller lever for AHU door.
Supply and fixing in replacement environment friendly, ultramodern, energy saving, surface mounted, decorative LED Bulk Head luminaire 10 W fixed on AHU including necessary connections to make it functional complete all as specified and directed. Make: Make: Havells/Crompton/Wipro/Luker.
Supply and fixing in replacement Wire netting as required size of galvanised steel wire 0.91mm dia fixed with tinned tacks of wire staples , size of mesh 12 mm complete all as specified and directed.
Replacement the mercury in glass industrial type thermometers adequately supported as per specifications complete all as specified and as directed.
Supply and fixing in replacement of discharge pressure gauge 4” dia, range 0 to 300 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york
Supply and fixing in replacement in replacement of suction pressure gauge 4” dia, range 0 to 150 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york
Supply and fixing in replacement in replacement of water pressure gauge 4” dia, range 0 to 100 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york
Supply and fixing in replacement of V- belt B-68 heavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Navyug/Dunlop
All as per srl item No 39.00 here-in-before but Size B-70
All as per srl item No 39.00 here-in-before but Size B-72.
All as per srl item No 39.00 here-in-before but Size B-94
Supply and fixing in replacement in replacement of V- belt A-31 heavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Navyug/Dunlop
All as per srl item No 43.00 here-in-before but Size A-32
All as per srl item No 43.00 here-in-before but Size A-34
All as per srl item No 43.00 here-in-before but Size A-36
Supply and fixing in replacement in replacement of thermostat expansion valve suitable for AC plant 50 tr capacity complete all as specified and directed. Make:- Sporlan/ Danfoss/ Renutrol or equivalent.
Supply and fixing in replacement Finned strip heater made of GP sheathing having terminals at one end and two holes for horizontal installation of capacity 3 KW in Air Conditioning plant installed at various locations complete all as specified or as directed. Make:- Daspass/Lazer/Usha
Servicing/repair of humidity control unit alongwith steam generator of central AC plant/Package type AC plant to make it functional including replacement of any spare required except heating element all as specified and directed.
Supply and fixing in replacement heating element of capacity 9x1 KW in steam generator of Air Conditioning plant installed at various locations complete all as specified or as directed. Make:- Daspass/Lazer/Usha
Supply and fixing Fine filter of size 610x300x50mm having dust filtration level 5 micron 95% efficiency as per existing type, make and size complete all as specified and as directed.
Supply and fixing Fine filter of size 610x610x50mm having dust filtration level 5 micron 95% efficiency as per existing type, make and size complete all as specified and as directed.
Supply and fixing Fine filter of size 450x510x50mm having dust filtration level 5 micron 95% efficiency as per existing type, make and size complete all as specified and as directed.
Supply and fixing Fine filter of size 420x510 x 50mm having dust filtration level 5 micron 95% efficiency as per existing type, make and size complete all as specified and as directed.
Supply and fixing Hepa filter of size 24"x24"x12" box type having dust filtration level 0.3 micron 95% efficiency as per existing type, make and size complete all as specified and as directed.
Servicing/Maintenance of packaged type AC of capacity 2x5.50/2x10TR TR such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Servicing/Maintenance of packaged type AC of capacity 2x15/3x15 TR/3x22 TR such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Preparation of old painted surfaces of AC plant central type of capacity 3x 50 TR including all motors, condensers, pumps, MS Pipes of various sizes, cooling tower and LT electric panel board installed at Heat stroke plant room painting with super enameled paint of approved quality with spray gun two coats over a coat of red oxide paint complete all as specified and as directed
Replacement of PVC honey comb fills (drift eliminators) suitable size of central type AC plant plant all as specified and directed.
Supply and fixing in replacement compressor factory reconditioned 7.5 TR performer, model 06 D / 018 for Voltas Packaged unit Model DUPA SH 1500 including gas charging and testing complete installed at ICU all as specified and as directed.
Supply and fixing in replacement connecting and testing of compressor scrolled sealed unit of capacity 5.5 TR performer, for Packaged AC plant/cold store including gas charging and testing complete all as specified and as directed. Make- DANFOSS/ KIRLOSKAR/TECUMSEH
Supply and fixing in replacement connecting and testing of compressor scrolled sealed unit of capacity 11 TR performer, for Packaged AC plant including gas charging and testing complete installed at Labour room all as specified and as directed. Make- DANFOSS/ KIRLOSKAR/TECUMSEH
Servicing of LT AC plant panel board of any size including connected AHU starter panels and wirings, cleaning of panel board internally and externally, tightening of all screws and nut & bolts, replacing of minor parts like screws, washers, lugs etc, checking of serviceability of all switch gears all as specified and as directed.
Material and labour for PVC insulated and unsheathed, flexible wire with multi stranded copper conductor wire of size single core, 6 sqmm, ISI marked complete all as specified and directed.
Supply and fixing Single phase preventer of male GIC/L&T or other equivalent approved make.
Replacement of electronic timer 240v, 50 Hz, 3-30 sec for star delta starter. Make L & Tor equivalent.
Supply and fixing in replacement of ON/OFF Push button with element complete all as directed.
Supply and fixing in replacement PCB in the existing Packed unit/ Cold room AC Plant including necessary control wiring as required. Model No - 22 TR PMN MPD Twin Make - Softhard Automation Pvt Ltd or in equivalent.
Supply and fixing in replacement PCB in the existing Packed unit/ Cold room AC Plant including necessary control wiring as required. Model No - 15 TR PMN MPD Twin. Make - Softhard Automation Pvt Ltd or in equivalent.
Supply and fixing in replacement Contactor MNX, 32 amp 3 pole complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing in replacement Contactor MNX, 45 amp 3 pole complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing in replacement Contactor MNX, 25 amp 3 pole complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing in replacement of indicator Neon lamp complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing in replacement of Ammeter analog type 0-200 Amp, 96x96mm CT Operated complete all as specified and as directed. Make- L&T/ Schiender/ Indotech
Supply and fixing in replacement of Ammeter analog type 0-100 Amp, 96x96mm complete all as specified and as directed. Make CTs 30/5. Make- L&T/ Schiender/ Indotech
Supply and fixing in replacement of Ammeter analog type 0-50 Amp, 96x96mm complete all as specified and as directed. Make CTs 30/5. Make- L&T/ Schiender/ Indotech
Supply and fixing in replacement of Voltmeter analog type 0-500 Amp, 96x96mm complete all as specified and as directed. Make- L&T/ Schiender/ Square
Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron earth strip of size 32x6 mm by means of bolts, nuts, washers and check nuts made out of galvanised iron upto test point and aluminium strip 32x6 mm from test point to equipment protected by GI pipe light grade 40 mm bore dia and connected to main control board all as shown in Electrical plate No 3 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoal dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed.
Material and labour for Earth continuity conductor or main earth lead fixed on wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to pole or any other indicated as required on ground for 25 x 4mm aluminium strip complete all as specified and as directed.
Supply and fixing in replacement ball bearing of size 6205 complete all as specified and directed. Make- SKF/NBC/TATA
Supply and fixing in replacement ball bearing of size 6306 complete all as specified and directed. Make- SKF/NBC/TATA
Supply and fixing in replacement ball bearing of size 6307 complete all as specified and directed. Make- SKF/NBC/TATA
Supply and fixing in replacement ball bearing of size 6308 complete all as specified and directed. Make- SKF/NBC/TATA
Supply and fixing in replacement toggle 5 Amp switch two way brass handle as per sample complete all as specified and directed.
Supply and fixing in replacement LP HP cut out M15 as per sample complete all as specified and directed. Make- Denfoss/indfoss
Supply and fixing in replacement compressor shaft oil seal of 50 TR complete all as specified and directed . Make-Voltas or equivalent.
Supply, installation, of GI construction Volume control Dampers, lever operated type as per specifications including required accessories complete all as specified and as directed.
Cutting of AC plant duct line of OT AC plant and making repair work all as specified and directed.
Supply , assembly and erection of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 26 Gauge.
Material and labour for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, 40MM thickness of insulation as specified
Servicing of cooling tower of capacity 100 TR plant by replacement of blocked/broken nozzles, Cooling tower fan and motor, cleaning descaling of complete fins including replacement of broken fin, cleaning water tray, valves, piping etc and testing complete all as per specified and directed.
Supply and fixing in replacement Main contactor Type 3TF 46 complete all as specified and directed Make - Siemens/BCH/L&T/Schneider.
Supply and fixing in replacement Main contactor Type 3TF 34 complete all as specified and directed Make - Siemens/BCH/L&T/Schneider.
Supply and fixing in replacement over load Relay 6 to 10 Amp complete all as specified and directed Make -Siemens/BCH/L&T/Schneider.
Supply, fixing, connecting, and testing condenser fan motor of outdoor air-cooled condensers of AC plant/cold store capacity 5.5 TR/7.5TR/11TR as per existing type and size including taking out of unserviceable motor complete all as per specified and directed.
Supply, fixing, connecting, and testing evaporator fan motor of cold store capacity 5.5TR/8.5 TR as per existing type and size including taking out of unserviceable motor complete all as per specified and directed.
Supply, fixing, connecting, and testing molecular drier cum strainer on line type of size 3/8" x 3/8" make Danfoss in AC plant capacity 5.5 TR make Blue star as per existing type and size including taking out of unserviceable drier complete all as per specified and directed.
Servicing/Maintenance of walk-in cooler of capacity 9000 ltr with PUF panel cabin such as checking Gas and gas leakage, cleaning of condensing coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motors, Cleaning and washing of complete indoor and outdoor unit and PUF cabin, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Servicing/Maintenance of Cold store of capacity 2x5.5 TR/8.5 TR such as checking Gas and gas leakage, cleaning of condensing coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Supply and fixing rolled mild steel work in joist, channel, angle, or tee sections, fixed independently, without connecting plates etc., cut to within 20mm of the length indicated, quality confirming to GDE Fe-410-S for cooling tower repair and pump mounting base complete all as specified and as directed.
Material and labour for servicing of rolling shutter of any size by cleaning of all moving parts and greasing to make smooth moving all as specified and directed.
Preparation of old painted surfaces of rolling shutter installed at E/M installation, painting with super enameled paint of approved quality with spray gun two coats over a coat of red oxide paint complete all as specified and as directed
Supply and fix first aid kit as per standard practice for E/M installation all as specified and directed.
MATERIAL AND LABOUR PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundations of feeder piller box/ LT panel upto 40 cm height from ground level including necessary form work, preparation of surfaces for concreting, sub-base and fair finish to exposed surfaces without using extra cement etc complete all as specified.
Cutting of MS pipe line of size 150mm/125mm and jointing new MS pipe including welding work aall as specified and directed.
Supply and fixing in replacement Flanged MS pipe heavy grade 150mm dia bore all as specified and directed.
Supply and fixing in replacement Strainer Y type conforming to IS, size 150 mm dia. complete.
Supply and fixing in replacement Flanged butterfly valve for MS pipe heavy grade 150mm dia bore all as specified and directed.
Supply and fixing in replacement Flanged butterfly valve for MS pipe heavy grade 100mm dia bore all as specified and directed.
Supply and fixing in replacement gun metal Gate valve for GI pipe 25mm dia bore both side female screwed all as specified and directed.
Supply and fixing in replacement gun metal Gate valve for GI pipe 15mm dia bore both side female screwed all as specified and directed.
Supply and fixing in replacement brass sprinkler head for GI pipe 15mm dia bore all as specified and directed.
Supply and fixing in replacement GI pipe Medium grade 15mm dia bore with all fittings bends, unions, tees, etc. all as specified and directed.
Supply and fixing in replacement GI pipe Medium grade 25mm dia bore with all fittings bends, unions, tees, etc. all as specified and directed.
Supply and fixing in replacement GI pipe Medium grade 20mm dia bore with all fittings bends, unions, tees, etc. all as specified and directed.
LOVELY AIRCON SYSTEMS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .