Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.3 LAccepted-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹99.9 L+₹22.3 L (28.7%)Rejected-Finance | L2 | Rejected-Finance Other than lower bidder | |
| 3 | Rejected-Technical BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | - | Rejected-Technical Reject due to the work pertain to provn of fire detection system. But the firm is enlisted in c(vi) cagetory for repair and maintenance only | |
| 4 | Rejected-Technical | - | Rejected-Technical Reject due to the work pertain to provn of fire detection system. But the firm is enlisted in c(vi) cagetory for repair and maintenance only | |
| 5 | Rejected-Technical | - | Rejected-Technical Reject due to the work pertain to provn of fire detection system. But the firm is enlisted in c(vi) cagetory for repair and maintenance only |
| Sl No | Description | Qty | Unit | DARSHAN CONSTRUCTION Co. L2 | sapana enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | Supply, installing and Testing and commissioning of wired microprocessor based addressable fire defection and alarm type control panel with capacity of four Loop panel with capacity from 99 detectors & 99 modules up to 200 detectors and modules per each loop,complete with all acessories and battery back up for 48 Hrs in stand by mode and 60 Minutes in alarm condition. Each loop shall support analog/addressable devices maximum capacity and have TCP/IP facility and Qwerty key pad for programming and including relay module, Control Module, Zone Module, Fault Isolator, power supply module addon modules. The panel shall be as per tech specification UL listed RS 232 communication port and RS 422 card in all respect and all as specified and directed.
i) The fire alarm system accessories such as smoke sensor, beam sensor, MCP, Isolator, repeater panel etc shall be of same make and shall be compatible to communicate with control panel.
ii) Layout diagram of Fire alarm system shall be submited by contractor for approval of accepting officer, and execution work shall only commence after approval of layout diagram and contractor is bound to execute work as per approved without any financial effect.
iii) On installation of the system, entire system shall be tested in presence of user rep and rep of accepting officer.
iv) Contractor shall provide display board duly indicating the location of sensor and its specified address.
v) Contractor shall provide layout diagram of eintire system in site plan/lay out plan indicating each component along with fire alarm cable connected to control panel.
(vi) Contractor shall make layout diagram of bldg and site plan, site measurement rquired shall be responsibility of contractor and any data required with respect to site for preparation of layout diagram shall be collected by contractor from site/bldg's. | 5 | Each | 3,15,000 ₹15,75,000 | 2,30,000 ₹11,50,000 Lowest |
| 2.00 | Supply and fix adressable smoke Detectors Complying with and type certified to EN-45 type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360 including addressing the detector shall be polarity insensitive & smart addressable type, mechanical dip switch or rotary addressing not allowed operating temp trasient-100 C to 850 C. The detector should have dual polling 360 degree view able LED with 4 class approved response mode and addressing shall be duly marked on sensor all as specified and directed by Engr-In-Charge. | 256 | Each | 3,250 ₹8,32,000 | 2,700 ₹6,91,200 Lowest |
| 3.00 | Supply , fixing and testing Addressable sounder hooter cum strobe 120Db all as specified and directed By Engr-In-Charge. | 14 | Each | 6,500 ₹91,000 | 5,200 ₹72,800 Lowest |
| 4.00 | Supply, install, testing and comissioning of adressable break glass manual call point including sunken boxes, with built in monitor module will all acessories and signal indicator complete as per tech specification and shall be UL listed complete. | 27 | Each | 4,985 ₹1,34,595 | 4,100 ₹1,10,700 Lowest |
| 5.00 | S&F Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB 1000 mtrs range with starter and all connected items all as specified. | 4 | Each | 35,000 ₹1,40,000 | 11,000 ₹44,000 Lowest |
| 6.00 | Supply, laying, electrical connecting and testing FRLS 4 core 1.5 sqmm (red Colour) armoured multi stranded copper conductor heavy duty underground cable 1100V saddled in wall/ceiling, truss, trench or laid in DWC pipe etc for fire alarm system all as specified and directed by engineer-in-charge | 9,950 | RM | 180 ₹17,91,000 | 167 ₹16,61,650 Lowest |
| 7.00 | Supply , fixing and testing adressable Beam Master detector Transreceiver type, including control module, power supply module 24V, 10 Amp DC, monitor module, relay module for converting conventional device into addressable device complete all as specified and directed.
Note
(i) The quoted rate is deemed to be inclusive of any additional accessories modules to make the detector functional in all respect. | 34 | Each Set | 46,000 ₹15,64,000 | 24,500 ₹8,33,000 Lowest |
| 8.00 | Sypply and fix electric motor siren (Fixed at any height/Locationas directed)conforming to IS 1941 suitable for 3 phase 415 Volts supply with motor not exeeding 3.75 KW and able to deliver 143 DB level. Siren shall have automatic equipment for producing a warbling note and including starter unit, relay module, foundation, GI Bracket made out of angle iron 50x50x6mm for mounting of siren and including G I cover /shade of thickness 2mm sheet with frame/stand for protection of the motor from rain etc complete all as specified and directed. | 3 | Each | 75,400 ₹2,26,200 | 23,000 ₹69,000 Lowest |
| 9.00 | Supply and fix sheet metal enclosure surface mounted MCB DB single door TPN 4 way 415 V, suitable for fixing one 40 A 4 pole MCB including S&F of one TPN 40 A MCB C Curve and connecting to wiring/ Cable including copper Lugs complete all as specified and directed by Engr-In-charge. | 3 | Each | 5,000 ₹15,000 | 4,200 ₹12,600 Lowest |
| 10.00 | Supply and laying of copper conductor armoured cable of size 4sqmm 4 core along wall/ pole/ into pipe/ in trench/ along truss etc at any height including saddling, electric connection and testing, the cable shall be PVC Innersheathed, armoured , PVC outer sheathning 1100V grade as per IS7098 (Pt1) of 1988 complete all as specified and directed. | 200 | RM | 400 ₹80,000 | 293 ₹58,600 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
23 Jun 2025, 6:00 pmClosed
COL SP SINGH
CWE AF MILITARY ENGINEERS SERVICE LOHEGAON, PUNE-411032
PROVN OF FIRE DETECTION SYSTEM AND ALLIED WORKS AT LSW HANGER AT 9BRD
2025_MES_707859_1
81958/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF LOHEGAON
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
GE AF LOHEGAON
₹1.8 L
Yes
17 Nov 2025
13 May 2025
30 Jun 2025
13 May 2025
23 Jun 2025
10 Jun 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .